Expression of Interest for electrical items required for the annual maintenance of the office, which are not included in the Electrical Schedule of Rates.
DMA/2026-27/EL/WORK_INDENT59283
DMA/2026-27/EL/WORK_INDENT59283
Open
Electrical
Electronic Documents, First(One Cover)
DMA City Corporation Mysuru
2 documents required · 2 mandatory
₹500
8 Jun 2026
8 Jun 2026
11 Jun 2026
Expression of Interest for "electrical items required for the annual maintenance of the office, which are not included in the Electrical Schedule of Rates".
1 Opeartion and Maintanance of light source High Pressure 250 Watts Metal halide flood light luminary includes supply and replacement of all components / materials such as lamps , chokes, ballasts, starters, condesners, ignitors, side holders, etc. in completer manner including cost of labour and material as directed by the engineer in charge Each 1
2 Opeartion and Maintanance of High Pressure 400 Watts Metal halide flood light luminary includes supply and replacement of all components / materials such as lamps , chokes, ballasts, starters, condesners, ignitors, side holders, etc. in completer manner including cost of labour and material as directed by the engineer in charge Each 1
3 Operation and Maintenance of Exhaust fan including rewinding of exhaust fan of all size with brackets blades etc, in completer manner including cost of labour and material as directed by the engineer in charge Each 1
4 Operation and maintenance of AC One TR/Two TR/ Three TR including repair of sealed compressor/air cooled condenser, repair and replacement of ,motor capacitor and start run capacitors, relay and over load protector internal unit refilling of coolant etc, in complete manner including cost of labour and material as directed by the engineer in charge Each 1
5 Operation and Maintenance of Central control unit having powers up to 60 microphone units and supports up to 250 units. Also supports 2 language channels. Two analog audio inputs for external sources such as wireless microphones, and 8 analog audio outputs for connection to videoconferencing system, A/V recording equipment, supplemental sound reinforcement system, or wireless language distribution system.Fully digital audio transmission of floor plus 31 interpretation channels and 8 conference microphone audio channels in a single digital bus cable structure using shielded CAT5e cables in complete Manner including periodic Service, As Directed by the Engineer In-Charge including cost of Labour and material. Each 1
6 Operation and Maintenance of Power Supply for Central Control Unit (CCU) models and adheres to energy-efficient power standards in complete Manner including periodic Service, As Directed by the Engineer In-Charge including cost of Labour and material Each 1
7 Operation and Maintenance of two-channel recorder/player for network applications should have SD card recorder/players for virtually any installation. Extensive I/O including balanced, unbalanced and DANTE interconnectivity are joined by a microphone preamp with phantom power and ducking. Audio may be recorded to SD Card or USB stick and uploaded automatically to your desired FTP server. In addition, recording and playback can be controlled via SNTP, network control, the optional RC-SS150 remote control or the free iOS/Android app in complete Manner including periodic Service, As Directed by the Engineer In-Charge including cost of Labour and material Each 1
8 Operation and Maintenance of 2 ways ACTIVE top unit for PA, should have Compact 2-way FOH system, Multi-functional and lightweight, Suitable for mobile, portable use, Fixed installation, Mirror monitor configuration, Compatible with Powerdrive accessories, Tiltable flange in complete Manner including periodic Service, As Directed by the Engineer In-Charge including cost of Labour and material Each 1
9 Operation and Maintenance of Digital Processor, Highend A/D and D/A converters, 2 Inputs / 6 Outputs; Matrix routing, Crossover, EQ, Delay, Phase, Noise gate and Limiter Functions on Each Output, Crossover slope: 12dB, 18dB, 24dB, 48dB per octave, Crossover types: Linkwitz-Riley, Bessel and Butterworth Filters, 6 bands EQ through output stage. EQ types: parametric, low shelf, high shelf, Up 7ms maximum delay time for output delay, step 21ms, Full parameters for limiter: attack, release, threshold and hold time, Full parameters for noise gate: attack, release and threshold, Polarity reverse control on each output, 16 user memories, friendly user interface, Programmable by rear panel, USB, XLR Audio Connections, Balanced Inputs and Outputs, 220 characters LCD with backlight and Switch Power Supply: 90250V.in complete Manner including periodic Service, As Directed by the Engineer In-Charge including cost of Labour and material Each 1
10 Operation and Maintenance of power conditioner with highest level of surge & spike protection available. Noise Filtration LiFT offers AC power filtering to ensure clean power for unequaled audio & video clarity.Front panel USB Charger to charge most media devices or power a USB lamp. Voltmeter / Ammeter Large digital voltmeter / ammeter, with discrete dimmer button, displays line votlage and true RMS current draw. Isolated Banks Isolated outlet banks minimize inter-component interference and noise contamination. 16 AMP Rating 16 Amp rating featuring a high inrush magnetic circuit breaker for added protection. 11 Total Outlets (10 rear panel outlets and one front panel convenience outlet). BNC Lamp Connector Rear panel BNC connector powers any standard gooseneck lamp for rear rack illumination in complete Manner including periodic Service, As Directed by the Engineer In-Charge including cost of Labour and material Each 1
11 Periodic Checking and testing of Distilled water for existing UPS batteries Ltr 1
12 Periodic Checking and replacement of Air/ fuel/oil filter of the existing Diesel Genarator set as per the standard maintenance schedule. Each 1
13 Operation and Maintenance of Upto 200 KVA Diesel-Generator set (Fuel tank, stator motor, batteries, control panel, accoustic enclosures) and its engine systems(Air, lube, fuel system), consumables like Air filter, engine oil, batteries servicing, AMF panel, etc including periodic cleaning of DG Set enclsoures from dust in complete manner - as per the direction of Engineer-in-charge of the work - SHOULD HAVE VALID ELECTRICAL LICENSES Job 1
14 Operation and Maintenance of Furnace main door with Main door lifting mechanism by manual & motor operating system, Counter weight, Ash removing door & Ash tray, Ash removing tools, Sprockets, chain, Gearbox, Motor & other accessories and 3 stage foldable trolley with periodic maintenance by lubrication and cleaning in complete manner -- as per the direction of Engineer-in-charge of the work Job 1
15 Operation and Maintenance of Refractory bricks of standard temperature with standing capacity upto 1200 Deg Celsius including periodic maintenance by properly checking for any cracks/vents & sealing/replacing them in complete manner -- as per the direction of Engineer-in-charge of the work Job 1
16 Operation and Maintenance of Burning Machinaries control panel consisting of Advanced Motor operating contactors relay, indicating lamps, push buttons, current transformer, Voltmeter, Ammeter, Temperature controller, safety equipments & switches, isolators near equipment, MCCB, non-corrosive heat resistant control & power cables including periodic maintenance and repair/replacement under faulty conditions in complete manner -- as per the direction of Engineer-in-charge of the work Job 1
17 Operation and Maintenance of Fresh air blower consisting of 1 HP blower, connecting duct controlled by butterfly valves from blower to furnace for fresh air flow to inside furnace with periodic maintenance by lubricating & cleaning and repair/rewinding/replacement under faulty conditions in complete manner -- as per the direction of Engineer-in-charge of the work Job 1
18 Operation and Maintenance of SS water scrubber unit with vertical venture arrangement & water circulating system with periodic maintenance including regular draining of water & cleaning the unit in complete manner -- as per the direction of Engineer-in-charge of the work Job 1
19 Operation and Maintenance of 7.5 HP 3 Phase motor Exhaust blower with belt driven blower fan, shaft & bearing, inlet & outlet pipe with periodic maintenance by lubricating & cleaning and repair/rewinding/replacement under faulty conditions in complete manner -- as per the direction of Engineer-in-charge of the work Job 1
20 Operation and Maintenance of Electrical accessories in the crematorium building consisting of LED lights, Ceiling fan, Exhaust fan, Switches, Sockets, Fan Regulators, MCBs and MCCBs, LED indicators, APFC components, capacitors & other allied accessories in the main control panel with periodic maintenance including regular cleaning of the panel from dust. Earthing Pit shall be watered regularly to keep resistivity under standard conditions during dry days. Transformer yard should be periodically cleaned for removal of unwanted weeds, etc. Crematorium builing & premises shall be cleaned everyday using cleaning agents and shall be kept in proper hygienic condition in complete manner -- as per the direction of Engineer-in-charge of the work Job 1
21 Operation and Maintenance of Heating coils made of Nichrome wire 80/20 of gauge 8, Vertically mountable Coils each of 3.5 kW capacity housed in ceramic insulation 316 grade Stainless steel by properly controlling them to recommended temperature vide Cotrol panel -- as per the direction of Engineer-in-charge of the work Job 1
22 comprehensive lump-sum scrap value for the old released UPS batteries ranging from 80 Ah to 150 Ah, incorporating all costs including recovery value of lead and plastic casing, collection from the designated location, safe transportation to an authorized recycling facility, and environmentally compliant disposal in accordance with Hazardous Waste Management Rules, with the quoted amount representing the net value payable to the client after deducting all contractor expenses such as labor, logistics, fuel, administrative charges, and disposal fees, and the contractor must provide a valid disposal certificate and recycling documentation upon completion, ensuring no acid leakage or environmental contamination during handling, Each 1
Expression of Interest for "electrical items required for the annual maintenance of the office, which are not included in the Electrical Schedule of Rates".
1 Opeartion and Maintanance of light source High Pressure 250 Watts Metal halide flood light luminary includes supply and replacement of all components / materials such as lamps , chokes, ballasts, starters, condesners, ignitors, side holders, etc. in completer manner including cost of labour and material as directed by the engineer in charge Each 1
2 Opeartion and Maintanance of High Pressure 400 Watts Metal halide flood light luminary includes supply and replacement of all components / materials such as lamps , chokes, ballasts, starters, condesners, ignitors, side holders, etc. in completer manner including cost of labour and material as directed by the engineer in charge Each 1
3 Operation and Maintenance of Exhaust fan including rewinding of exhaust fan of all size with brackets blades etc, in completer manner including cost of labour and material as directed by the engineer in charge Each 1
4 Operation and maintenance of AC One TR/Two TR/ Three TR including repair of sealed compressor/air cooled condenser, repair and replacement of ,motor capacitor and start run capacitors, relay and over load protector internal unit refilling of coolant etc, in complete manner including cost of labour and material as directed by the engineer in charge Each 1
5 Operation and Maintenance of Central control unit having powers up to 60 microphone units and supports up to 250 units. Also supports 2 language channels. Two analog audio inputs for external sources such as wireless microphones, and 8 analog audio outputs for connection to videoconferencing system, A/V recording equipment, supplemental sound reinforcement system, or wireless language distribution system.Fully digital audio transmission of floor plus 31 interpretation channels and 8 conference microphone audio channels in a single digital bus cable structure using shielded CAT5e cables in complete Manner including periodic Service, As Directed by the Engineer In-Charge including cost of Labour and material. Each 1
6 Operation and Maintenance of Power Supply for Central Control Unit (CCU) models and adheres to energy-efficient power standards in complete Manner including periodic Service, As Directed by the Engineer In-Charge including cost of Labour and material Each 1
7 Operation and Maintenance of two-channel recorder/player for network applications should have SD card recorder/players for virtually any installation. Extensive I/O including balanced, unbalanced and DANTE interconnectivity are joined by a microphone preamp with phantom power and ducking. Audio may be recorded to SD Card or USB stick and uploaded automatically to your desired FTP server. In addition, recording and playback can be controlled via SNTP, network control, the optional RC-SS150 remote control or the free iOS/Android app in complete Manner including periodic Service, As Directed by the Engineer In-Charge including cost of Labour and material Each 1
8 Operation and Maintenance of 2 ways ACTIVE top unit for PA, should have Compact 2-way FOH system, Multi-functional and lightweight, Suitable for mobile, portable use, Fixed installation, Mirror monitor configuration, Compatible with Powerdrive accessories, Tiltable flange in complete Manner including periodic Service, As Directed by the Engineer In-Charge including cost of Labour and material Each 1
9 Operation and Maintenance of Digital Processor, Highend A/D and D/A converters, 2 Inputs / 6 Outputs; Matrix routing, Crossover, EQ, Delay, Phase, Noise gate and Limiter Functions on Each Output, Crossover slope: 12dB, 18dB, 24dB, 48dB per octave, Crossover types: Linkwitz-Riley, Bessel and Butterworth Filters, 6 bands EQ through output stage. EQ types: parametric, low shelf, high shelf, Up 7ms maximum delay time for output delay, step 21ms, Full parameters for limiter: attack, release, threshold and hold time, Full parameters for noise gate: attack, release and threshold, Polarity reverse control on each output, 16 user memories, friendly user interface, Programmable by rear panel, USB, XLR Audio Connections, Balanced Inputs and Outputs, 220 characters LCD with backlight and Switch Power Supply: 90250V.in complete Manner including periodic Service, As Directed by the Engineer In-Charge including cost of Labour and material Each 1
10 Operation and Maintenance of power conditioner with highest level of surge & spike protection available. Noise Filtration LiFT offers AC power filtering to ensure clean power for unequaled audio & video clarity.Front panel USB Charger to charge most media devices or power a USB lamp. Voltmeter / Ammeter Large digital voltmeter / ammeter, with discrete dimmer button, displays line votlage and true RMS current draw. Isolated Banks Isolated outlet banks minimize inter-component interference and noise contamination. 16 AMP Rating 16 Amp rating featuring a high inrush magnetic circuit breaker for added protection. 11 Total Outlets (10 rear panel outlets and one front panel convenience outlet). BNC Lamp Connector Rear panel BNC connector powers any standard gooseneck lamp for rear rack illumination in complete Manner including periodic Service, As Directed by the Engineer In-Charge including cost of Labour and material Each 1
11 Periodic Checking and testing of Distilled water for existing UPS batteries Ltr 1
12 Periodic Checking and replacement of Air/ fuel/oil filter of the existing Diesel Genarator set as per the standard maintenance schedule. Each 1
13 Operation and Maintenance of Upto 200 KVA Diesel-Generator set (Fuel tank, stator motor, batteries, control panel, accoustic enclosures) and its engine systems(Air, lube, fuel system), consumables like Air filter, engine oil, batteries servicing, AMF panel, etc including periodic cleaning of DG Set enclsoures from dust in complete manner - as per the direction of Engineer-in-charge of the work - SHOULD HAVE VALID ELECTRICAL LICENSES Job 1
14 Operation and Maintenance of Furnace main door with Main door lifting mechanism by manual & motor operating system, Counter weight, Ash removing door & Ash tray, Ash removing tools, Sprockets, chain, Gearbox, Motor & other accessories and 3 stage foldable trolley with periodic maintenance by lubrication and cleaning in complete manner -- as per the direction of Engineer-in-charge of the work Job 1
15 Operation and Maintenance of Refractory bricks of standard temperature with standing capacity upto 1200 Deg Celsius including periodic maintenance by properly checking for any cracks/vents & sealing/replacing them in complete manner -- as per the direction of Engineer-in-charge of the work Job 1
16 Operation and Maintenance of Burning Machinaries control panel consisting of Advanced Motor operating contactors relay, indicating lamps, push buttons, current transformer, Voltmeter, Ammeter, Temperature controller, safety equipments & switches, isolators near equipment, MCCB, non-corrosive heat resistant control & power cables including periodic maintenance and repair/replacement under faulty conditions in complete manner -- as per the direction of Engineer-in-charge of the work Job 1
17 Operation and Maintenance of Fresh air blower consisting of 1 HP blower, connecting duct controlled by butterfly valves from blower to furnace for fresh air flow to inside furnace with periodic maintenance by lubricating & cleaning and repair/rewinding/replacement under faulty conditions in complete manner -- as per the direction of Engineer-in-charge of the work Job 1
18 Operation and Maintenance of SS water scrubber unit with vertical venture arrangement & water circulating system with periodic maintenance including regular draining of water & cleaning the unit in complete manner -- as per the direction of Engineer-in-charge of the work Job 1
19 Operation and Maintenance of 7.5 HP 3 Phase motor Exhaust blower with belt driven blower fan, shaft & bearing, inlet & outlet pipe with periodic maintenance by lubricating & cleaning and repair/rewinding/replacement under faulty conditions in complete manner -- as per the direction of Engineer-in-charge of the work Job 1
20 Operation and Maintenance of Electrical accessories in the crematorium building consisting of LED lights, Ceiling fan, Exhaust fan, Switches, Sockets, Fan Regulators, MCBs and MCCBs, LED indicators, APFC components, capacitors & other allied accessories in the main control panel with periodic maintenance including regular cleaning of the panel from dust. Earthing Pit shall be watered regularly to keep resistivity under standard conditions during dry days. Transformer yard should be periodically cleaned for removal of unwanted weeds, etc. Crematorium builing & premises shall be cleaned everyday using cleaning agents and shall be kept in proper hygienic condition in complete manner -- as per the direction of Engineer-in-charge of the work Job 1
21 Operation and Maintenance of Heating coils made of Nichrome wire 80/20 of gauge 8, Vertically mountable Coils each of 3.5 kW capacity housed in ceramic insulation 316 grade Stainless steel by properly controlling them to recommended temperature vide Cotrol panel -- as per the direction of Engineer-in-charge of the work Job 1
22 comprehensive lump-sum scrap value for the old released UPS batteries ranging from 80 Ah to 150 Ah, incorporating all costs including recovery value of lead and plastic casing, collection from the designated location, safe transportation to an authorized recycling facility, and environmentally compliant disposal in accordance with Hazardous Waste Management Rules, with the quoted amount representing the net value payable to the client after deducting all contractor expenses such as labor, logistics, fuel, administrative charges, and disposal fees, and the contractor must provide a valid disposal certificate and recycling documentation upon completion, ensuring no acid leakage or environmental contamination during handling, Each 1
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
EOI GRAVY YARD.xlsx
Tender Document • 0.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .