Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.5 CrAccepted-AOC KARTHIK BHAWAN GANDHI BASTI SILPUKHURI GUWAHATI | KAMRUP METRO | ASSAM | 781001 | ₹1.5 Cr | 1 | Accepted-AOC Financially lowest evaluated responsive bidder |
| 2 | 2₹1.5 CrSame as 1Rejected-AOC | ₹1.5 CrSame as 1 | 2 | Rejected-AOC Financially lowest evaluated responsive bidder |
| 3 | 3₹1.5 Cr+₹0.01 (<0.01%)Rejected-AOC RAIDONGIA GAON P O KAMARBONDHA ALI P S GOLAGHAT GOLAGHAT PIN 785625 | GOLAGHAT | ASSAM | 785625 | ₹1.5 Cr+₹0.01 (<0.01%) | 3 | Rejected-AOC Financially second lowest evaluated responsive bidder |
| 4 | Not Admitted-Fee/PreQual/Technical VILL ROUMARI WARD NO 1 P O P S ABHAYAPURI DIST BONGAIGAON ASSAM | BONGAIGAON | ASSAM | - | - | Not Admitted-Fee/PreQual/Technical Others-HARD COPY OF BID NOT SUBMITTED |
Tender Value
₹1.7 Cr
EMD Value
₹3.4 L
Closing Date
6 Jul 2023, 2:00 pmClosed
DIRECTOR OF PHYSICAL PLANT,AAU,KHANAPARA
DIRECTOR OF PHYSICAL PLANT,AAU,KHANAPARA
CIVIL WORKS INCLUDING WATER SUPPLY AND ELECTRICAL WORKS
2023_AAU_31235_1
AAU/DPK/2023-24/1460-63 Dtd.12.03.2023
Open Tender
Civil Works
Item Rate
365 days
KVK, MANGALDOI
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,500
Yes
₹3.4 L
DIRECTOR OF PHYSICAL PLANT,AAU,KHANAPARA
9 Oct 2023
15 Jun 2023
6 Jul 2023
15 Jun 2023
6 Jul 2023
15 Jun 2023
15 Jun 2023 - 30 Jun 2023
30 Jun 2023
Amount
Earth work in excavation by mechanical (Hydraulic excavation)/ manual means over areas 2.6.1: all kinds if soil
Brick on edge flooring with bricks of class designation 7.5…
Providing and laying in position cement concrete specified grade excluding the cost of centering and shuttering…
Steel reinforcement for RCC work including staighteninng cutting bending…
Centering and shuttering including strutting propping etc and removal of 5.9.1: Foundation, footing bases..
Suspended floors, roofs, handing, balconies…
Coloumn, pillars, piers…
Lintel, beams, plint beams, girders…
Providing and laying in position specified grade of reinforced cement concrete 5.1.2:1:1.5:3
Reinforced cement concrete work in beams suspended floor roof having slop….
Brick work with common burnt clay brick of class designation….6.1.1:1:4
Half brick masonry with common burnt clay FPS class of designation.. 1:4
Providing and laying vitrified floor tles in different sizes, shape thickness…
Providing and fixing 1st quality ceramic glazed wall tiles…
Providing and laying rectified glazed ceramic floor tiles…
Providing and fixing stone slab with table, rubbed edges rounded and polished of size 75x50cm deep..
15mm thick cement plaster on rough side of single or half brick walls of mix.. 13.5.1:1:4
Providing wood work in frame of doors, windows clerestory windows… 9.1.2…
Providing and fixing paneldor paneled and glazed shutter for door, windows and clerestory windows..
Providing and fixing MS grills of required pattern in frame of windows..
Providing and fixing aluminium work for doors, windows ventilators and partition with extrneled built up standard..
Providing and fixing glazed in aluminium door, windows, ventilators shutters and partition..
Supplying and filling plinth with sand under floors including watering ramming consolidating and dressing complete..
Prviding and applying plaster of paries putty of 2mm thickness over plastered..
Wall painting with acrylic emulsion paint of appvd. Brand manufacturer..
Applying priming coats with primmer of approved brand and maufacturer..
finishing with Deluxe multi surface paint system for interior and exterior using 13.48.2:Painting wood work.
Finishing wall witharcylic smooth exterior paint of required shade 13.46.1: New work
Providing and fixing aluminium tower bolts ISI marked anodised..
Provding and fixing aluminium handles..
Providing and fixing stainless steel railing made of hollow tubes..
Diwting and injection chemical emulsion for post construction antitermite treatment.
Making plinth protection 50mm thick of cement concrete…
WATER SUPPLY WORKS:Providing and fixing white vitrious china pedestal type water closet (Europen type) with seat andlid.. 17.3.1: WC pan with ISI marked
Providing and fixing wash basin with CI brackets 15mm dia CP brass single hole basin mixer pf approved quality… white…
Providing and fixing white vitrious china flat back hall stall urinals of size 580x380x350mm white PVC flusing cistern… 17.5.1
Providing and fixing stainless steel AISI 304(18/8) kitchen sink as per…17.10.1
Providing and fixing CP brass 32mm size bottle trap of approved quality..
Providing and fixing white vitrious china squatting plate urinal ..
Providing and fixing PVC waste pipe for sink or wash basin including all fittings complete. 17.28.2:Flexible pipe, 17.28.2.2:40mm dia..
Providing and fixing 600x450mm leveled edge mirror of superior glass..
Providing and fixing toilet papers holder.. 17.34.1: CP brass..
Providing and fixing PTMT soap container..
Providing and fixing PTMT towel rail complete… 17.73.1: 450 long towel rail.
Providing and fixing PTMT shllf 440mm long..
Providing and fixing PTMT 15mm urinal spreader of sizes..
Providing and fixing PTMT urinal cock..
Providing and fixing CPVC pipes having thermal stability for hot and cold water.. 18.7.6:50mm dia..
18.7.1:15mm dia…
18.7.3: 25mm dia..
Providing and fixing brass bib cock of approved quality.. 18.15.1:15mm..
Providing and fixing brass stop cock of approved quality 18.16.1:15mm..
Providing and fixing GM gate valve with CI wheel.. 18.17.4: 50mm dia..
Providing and fixing GM non return valve of approved quality… 18.19.4:50mm nominal bore..
18.19.1:25mm nominal bore.
Construction masonry chamber of size 60x60x75 cm inside in brick work in cement morter 1:4.. 18.33.1:With common burnt clay FPS bricks..
Providing and fixing PTMT pillar cock of approved quality and colour..
Providing and fixing PTMT granting of approved quality..
Providing and placing on terrace (at all floor level) polyethylene water storage tank IS:12701 marked with cover and suitable loacking arrangement…
Construction brick masonry circular manhole 1.52mm internal dis at Bottom and 0..56m dia at top in cement morter 1:4… inside cement plaster 12mm thick with cement morter.. 19.13.1.1:With common burnt clay FPS (non-modular)
DEEP TUBEWELL:Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level.All types of soil 300 mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges,fittings & accessories, all complete, for all depths, as per direction200 mm nominal size dia having minimum wall thickness 5.40 mm
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge.200 mm nominal size dia
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air approved laboratory, i/c disinfection of tubewell, all complete, including compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:200 mm diaProviding and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.200 mm clamp
Providing and fixing Bail plug/ Bottom plug of required dia to thebottom of pipe assembly of tubewell as per IS:2800 (part I).200 mm dia
Water Supply WorkProviding and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etcExternal work 50 mm dia nominal bore
40 mm dia nominal bore
25 mm dia nominal bore
20 mm dia nominal bore
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50 mm nominal dia Pipes
Providing and fixing gun metal non- return valve of approved quality (screwed end) :80 mm nominal boreHorizontal
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore
20 mm nominal bore
40 mm nominal bore
50 mm nominal bore
ELECTRICAL:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group A
Group B
Group C
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch
2 way 5/6 amps switch
15/16 amp switch
3 pin 5/6 amp socket outlet
6 pin 15/16 amp socket outlet
Telephone socket outlet
TV antenna socket outlet
Bell push
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm)
4 Module (125mmX75mm)
6 Module (200mmX75mm)
8 Module (125mmX125mm)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Erection of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS lamps per fitting, complete with all accessories including connection etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
510 mm sweep
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door
6 way (4 + 18), Double door
8 way (4 + 24), Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Single pole and neutral
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
Supplying of light fittings complete with all standard accessories as required. LED Bulb: KOLORS brand 9watt model no: 2204BU09 (CW)
LED Bulb: KOLORS brand 0.5 watt model no: 2204BU00 (YW)NANO LED NIGHT LAMP
LED batten: KOLORS brand 20 watt model no: 2402BA20 (WW) KARIS LED BATTEN LIGHT
9 watt KARIS SURFACE LED PANEL LIGHT ROUND, Model no: 2403PL09S (WW)
12 watt KARIS SURFACE LED PANEL LIGHT ROUND, Model no: 2403PL12R (WW)
Supplying of approved make ceiling fan of double ball bearing of the following sizes with resistance type regulator and its all accessories suitable for operation on 230V single phase, 50 Hz, AC supply complete as required. 1200mm sweep (USHA/GEC/ CROMPTON/ BAJAJ/HAVELLS)
Exhaust Fan of the following sizes and its all accessories suitable for operation on 230V single phase, 50 Hz, AC supply complete as required. 380 mm sweep (HAVELLS/CROMPTON/ BAJAJ)
Supplying installation, testing commissioning of telephone tag block or similar specification of other approved makes. of the following sizes 10 Pair
Supplying installation, testing & commissioning of RJ 45 Single Module Socket or similar specification of other approved makes. of the following sizes
Supplying with installation, testing & commissioning of Hi-wall 5 star rating non ducted split type Air Conditioner of the following capacity 2 ton capacity
Supplying with fitting & fixing Voltage Stabilizer of the following specification complete including making necessary connection 4.00 KVA Automatic input 90-280 V Output 200-240 V
Supplying and fitting fixing of electric storage water heater [Geyser] of AOS-Jaquar make) including necessary connection etc. as required complete and as directed by the Department. 6 Litre Capacity
10 Litre Capacity
5 HP single Phase Centrifugal monoblock pump set (Crompton Greaves/ Aquatic/ CRI/ V-Guard make) 2900 rpm with DOL Starter ( Crompton Greaves/ Control & Switch Gear/ BCH/ L& T / Siemens make) .
Supplying fitting and fixing including necessary connection as approved by the Deptt.)of Starter ( Crompton Greaves/ Control & Switch Gear/ BCH/ L& T / Siemens make) of following type and capacity as specified and directed by the Department. ( Crompton Greaves/ Control & Switch Gear/ BCH/ L& T / Siemens make) D.O.L Starter ( Crompton Greaves/ Control & Switch Gear/ BCH/ L& T / Siemens make)0.5 TO 10 HP, 0.72 TO 20 A.
Supplying including installation, testing and commissioning of Solar Street light as per following specification 20 Ah Li-Ion inbuilt battery 75 Wp Mehar/IB Solar panel 18 W LED Light with lense MS pole with GI coated in 06.00 mtr
Supplying installation testing and commissioning of 11/0.433KV Sub-Station equipments comprising H.T. Panel,Transformer, HT Cable, Bus trunking from Transformer to LT Panel, LT Panel, Automatic power factor corrector panel, Essential Panel i/c Earthing, inter connecting power cables in sub- station, safety equipments.
MS Clarion Projects
Kaustav Saikia
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .