| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.5 LAccepted-AOC NEAR AVON PUBLIC SCHOOL DABHANW POST DANDI NAINI PRAYAGRAJ 211008 | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211008 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹29.1 L+₹2.0 L (7.52%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹41.2 L+₹14.1 L (52.1%)Rejected-Finance 44 NEAR DURGA MANDIR TRIPURI TOABA TRIPURI TOWN PATIALA 147004 PB | PATIALA | PUNJAB | 147004 | L3 | Rejected-Finance Other than L1 |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
10 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST PRAYAGRAJ
GE WEST PRAYAGRAJ PIN-211001
REPAIR /MAINTENANCE OF ALL TYPE SUMMER / WINTER APPLIANCES ETC AT COD CHHEOKI UNDER GE WEST PRAYAGRAJ.
2024_MES_662914_2
8744/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
NEW CANTT PRAYAGRAJ
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE WEST PRAYAGRAJ
₹1 L
Yes
24 Jan 2025
19 Sept 2024
17 Oct 2024
19 Sept 2024
10 Oct 2024
26 Sept 2024
Amount
CEILING FAN, EXHAUST FAN
M&L for rewinding of stator complete with super enameled copper winding wire of existing gauge/ weight of copper coil, quick varnishing, oiling, greasing insulating materials including replacement of worn out parts like u/s cotter pin, nut, screw, check nuts and bolts as required incl. cleaning of body, and testing of the following size of fans of any make complete all as specified and directed. Note - (i) Fans to be collected by the contractor at their own arrangement from AGE E/M store for repair/rewinding and to be deposited at same place after making serviceable duly tested. (ii) Additional spare parts as required to make the serviceable of same will be measured and paid separately as supply only under respective item here in below:-
Ceiling fan of 1200 mm sweep
Ceiling fan of 1400 mm sweep
Exhaust fan of 230 mm sweep
Exhaust fan of 300 mm sweep
Exhaust fan of 380 mm sweep
Exhaust fan of 450 mm sweep
Wall fan/cabin/Pedestal of 400 mm sweep
Industrial wall fan of 480/ 600 mm sweep
Supply only following spare parts for Ceiling / Exhaust fan : -
Ball bearing of ceiling/exhaust fan of any size of exactly similar as existing in fan complete all as specified and directed. (Make-NBC/SKF)
U' shape shackle clamp assembly made out of MS flat iron incl checknut, bolts, screws, washer, split pin, lock nut, rubber reel etc. suitable to the down rod pipe and connecting complete all as specified and directed.
Capacitor 2.5 Mfd, 440 Volt AC complete all as specified and directed. Make - Asian/Usha/Epcos of siemens /Havells or as approved by GE
Capacitor 3.15 Mfd, 440 Volt AC complete all as specified and directed. Make - Asian/Usha/Epcos of siemens /Havells or as approved by GE
PVC insulated, sheathed flexible copper conductor cable in three core of size 23/0.0076 from connector to the ceiling rose complete all as specified and directed.
Capacitor clip as per existing complete all as specified and directed.
Canopy for ceiling fan suitable for any sweep/make as required incl. screw complete all as specified and directed.
M&L for Spray painting of stained/rusted/corroded Ceiling fan/Exhaust fan complete body with one coats of synthetic enamel white/smoke gray paint incl writing of MES No over one coat of primer all as specified and directed.
S&F in replacement of MS louvers shutters on wall suitable for following size of sweep exhaust fan including suitable size of nut, bolts & washer complete all as specified and directed.
300 mm sweep exhaust fan
450 mm sweep exhaust fan
M & L for servicing of ceiling fans at site, oiling, greasing and checking of fan hook for damage spilt pin, nut bolt, rubber reels and down rod including proving new split pin and replacement of damage nut bolt and down rod complete all as specified and directed. Note: (i) Down rod measured and paid separately under relevant items
S&F in replacement Mild steel 'Medium grade' 15mm dia pipe down rod of required length with making split, holes, cut etc at both end of pipe as required for hanging of ceiling fan including painting of rod with two coats of synthetic enamel white paint over one coat of primer along with U' shape shackle clamp assembly made out of MS flat iron incl checknut, bolts, screws, washer, split pin, lock nut, rubber reel complete all as specified and directed.
S&F in repair fan hook suitable for 40 mm dia pipe, made out of MS flat iron size 50x6 mm including suitable size of nut, bolt & washer complete all as specified and directed.
AC WINDOW/SPLIT TYPE
Repair/maint of window type AC/split AC any capacity of any make by cleaning and servicing of serviceable parts replacement of wiring kit, knobs & unserviceable parts replacement of air filter made of jute and reassembling the serviceable spare parts etc and testing for smooth functioning and re installation at site or deposit in MES store yard after repair. [Notes : (a) Spare parts shall be measured and paid separately as supply only under respective items. (b) Replacement of nuts, bolts and washers deemed to be included in unit rate. (c) Minor repair of chassis by brazing/welding work deemed to be included in unit rate.]
Removing burnt/defective sealed compressor unit of any make from any type of air conditioner window type 1.5 ton capacity by cutting of suction and discharge lines unscrewing the foundation nuts, bolts etc, supply amd fixing of new sealed compressor unit of suitable make as existing by connecting suction and discharge lines with gas welding/brazing work and tightening foundation nuts & bolts etc all as directed. Make: Emersion/ LG/ Haier
All as per item No. 9 above but for 1.5 ton Split type Air conditioner [Notes : (a) Capillary, drier, copper tubing etc are inclusive in unit rate. (b) New compressors will be purchased from authorised dealer only. (c) Unserviceable compressor either cut open or sealed unit have to be replaced by new one
All as per item No. 10 above but for air conditioner window / split type 2 ton capacity
Repair to Air conditioner window type/Split type 1/1.5/2 ton capacity by testing the leakage in system by filling of Nitrogen gas upto 300 PSIG and repairing of leaking spot/joints with gas welding work, cleaning and flushing out the complete system with gas, supply and replacing of drier/filter, making the complete system leak proof, vacuuming the system and charging of gas as existing and testing etc complete all as specified & directed (Note : Drier capillary and copper tubing are inclusive in unit rate)
S&F in replacement of blower Motor 1/5 or 1/6 HP 230V AC, 50 Hz suitable for Air conditioner window type 1.5 ton capacity blower motor complete all as directed and specified
S&F in replacement of blower Motor 0.2/0.25 HP for Air conditioner split type 1.5 ton/2 ton complete and as directed and specified (Make - GE/Crompton/Polar)
M & L for repair to blower Motor 1/6 HP to 0.25 HP with super enamelled copper wire of existing size suitable for Air conditioner window type / split type complete all as specified and directed
M& L for repair to PCB circuit in air conditioner split type all as specified & directed.
S&F in replacement of power contactor 240V AC, 50 Hz 16 - 25 Amps range (ISI marked) as approved complete all as specified and directed.
Supply and fixed in replacement of power contactor 415V AC, 50 Hz 15 Amps (Make - L&T Type MK-I/BCH or as approved)
M&L for painting of chassis/body of AC with one coat of synthetic enamel paint by spray painting of approved make including preparation of surface and one coat of aluminium paint to outer cover.
Supply only following spare parts for window type AC capacity 1.5/2 ton : -
Capacitor 4 mfd
Running capacitor 36 mfd AC
Starter capacitor 80/100 mfd
Relay any make and type as approved
Over load protector
Thermostat
Cooling coil
Filter pad made of Jute
Condensers coil
Wiring kit
Front Panel of window AC any make of 1.5/2TR
Blower
M&L for Stands for Discharge unit of Split type AC/ Desert cooler stand etc. as per requirement and directed by Engr -in-charge
S&F in replacement indoor unit of AC 1.5 ton capacity split type of approved make as directed (Note-Old unit to be deposited in MES store yard)
S&F in replacement of wireless remote control unit for split / window type air conditioner as per existing model complete all as specified & directed. Make:- Carrier (duracool)/ Carrier ( X power gold)/ LG/ Voltas
WATER COOLER
Dismantling of electric connection and water connection of water cooler & opening the condensor fan motor blade, electrical accessories and spare parts of system carefully servicing of serviceable parts, replacement of U/S parts, oiling of fan motor etc reassembling all spare parts incl rewiring of internal connection of water cooler, testing and commissioning complete all as specified. (Note : Worn out or unserviceable spare parts to be replaced & shall be measured and paid separately as supply only under respective item.)
Removing burnt/defective sealed compressor unit of any make from water cooler cap 40 Ltrs/hr by cutting of suction and discharge lines and unscrewing the foundation nuts & bolts etc, supply and fixing new sealed compressor unit Make as existing or equivalent in kirloskar or Tecumseh by tightening the foundation nuts and bolts and connecting suction and dischrage line with gas welding work etc complete. [Note:- (i) Cost of transportation shall be deemed to be included in the quoted rates. GI fitting damaged while taking out/fixing back water coolers shall be replaced by the contractor at his own cost. (ii) New compressor shall be purchased from authorised dealer only. (iii) Capillary, drier, filter strainer are inclusive in unit rate. (iv) Old compressor either cut open or sealed have to replaced with new one.]
All as per item No 27 above but water cooler Cap 60 Ltrs/hr
All as per item No 27 above but water cooler cap 150 Ltrs/hr.
M&L for replacement of Rubber hose pipe of 20mm bore with clips for outlet tray of water cooler of length 1.5 Mtr long approx. complete all as specified & directed
M&L for replacement of PVC sheet rubber bedding and lock of top cover of water cooler by screwing/welding MS sheet of top cover complete all as specified & directed
M&L for replacement of PVC connection rigid type 18” long 15mm bore, with adopter at both ends complete all as specified & directed.
M&L for making the system leak proof and charging of gas Freon 12/22 as required in water cooler of capacity 40/60 Ltr including replacement of drier and capacity tube and testing on load complete all as specified & directed.
All as per item No. 33 above but of capacity 120/150 ltrs.
M&L for scraping old painted surface of water cooler any capacity and painting with two coats of synthetic enameled paint including writing SM/MES No with black paint with minimum 25 mm size of letters complete all as specified & directed.
M&L for replacement of old condenser fins with new, forced air-cooled including necessary brazing work for water cooler of any capacity including testing for leakage complete all as specified & directed.
S&F in replacement of condenser fan motor of cap 1/35 HP with fan blade complete all as specified & directed.
M & L for winding of condenser fan motor of cap upto 1/8 HP with super enamelled copper wire of existing size including replacement of bush and fan blade incl painting complete all as specified & directed.
S&F in replacement of push cock/lift cock brass chromium plated 15 mm bore complete all as specified & directed..
M&L for replacement of flexible PVC pipe of following sizes for the drainage of waste water of water coolers or concealing the copper tubing of split AC and condensed moisture of air conditions complete all as specified & directed.
40 mm dia flexible PVC pipe
50 mm dia flexible PVC pipe
60 mm dia flexible PVC pipe
Detection and rectification of leakage of storage tank of water cooler by brazing soldering/welding as required at site or work shop testing for leak proof complete all as specified & directed. [Note : (a) Nipple adoptor if required deemed to be included in unit rate. (b) Push cock, float valve etc if required will be measured and paid separately. (c) Changing of rubber/plastic packing is incl in unit rate]
Taking out the drain tray with PVC pipe of water cooler, electroplating (chromium plating) of drain tray after repair by denting/painting and including replacement of new PVC pipe of suitable size and length and refixing back all as directed.
Supply only following spare parts for water cooler : -
Starting capacitor 60/80 mfd
Running capacitor 10 mfd
Thermostat
Relay over load kit
Relay
Over load protector 1022
Wiring kit
Strainer/filter drum type/pen type
Door gasket
Float valve 1/2" including assembly brass made.
VOLTAGE STABILIZER
M&L for opening unserviceable automatic voltage stabilizer capacity of the following capacity for repair, detection of fault and its repair cleaning of serviceable parts, replacement/repair of unserviceable or worn out parts soldering of terminal connection and testing after repair, painting with one coat of synthetic enamel paint externally all as specified including sign writing "AGE E/M New Cantt" all as directed any make:-[Note: (a) Replacement of new parts/worn out parts in lieu of unserviceable/worn out parts shall be measured and paid separately as supply only under respective item.(b) The flexible 3 core cable, 40/.0076, 23/.0076, 70/.0076 to be provided at least 1.5 RM is included in unit rate.]
Capacity 5 KVA / 4 KVA
Capacity 3 KVA
Supply only the following spare parts suitable for automatic voltage stabilizer of any make and capacity :-
Volt meter (0-300 volts)
Control relay
IC controlled circuit for 5KVA/4 KVA
IC controlled circuit for 3 KVA
Control transformer
Low/high voltage cut off and TDR system
Main transformer for 5 KVA/4 KVA
Main transformer 3 KVA
3 pin plug top 16 amp make Anchor
M&L for rewinding of boost/buck transformer of the following capacity stabilizer with copper wire of existing gauge and same number of turn with best quality insulating material including testing complete and refixing back electrically and mechanically complete all as specified & directed.
Capacity 5 KVA / 4 KVA
Capacity 3 KVA
S&F in replacement of 5 KVA stabilizer 230 volts Single phase (Note-Old to be deposited in MES store yard). (Make : Blue star/Vinitec/Brentford/Automatic Electric)
WINETR APPLIANCES
Taking down existing geyser any capacity/ type after suitable disconnecting all electrical and water supply connection, removing geyser to E/M store, opening and dismantling the complete geyser, cleaning all serviceable parts completely including descaling the geyser, for replacing the defective/worn out parts, reassembling the geyser, testing for proper functioning, transporting to & refixing in original location i.e. in the same in position, reconnecting the geyser with electric supply and water supply line and testing complete all as specified and directed. Note :- (i) Parts/spares required for replacement shall be measured and paid separately as supply only under respective item. (ii) Unit rate quoted shall be deemed to include minor items i.e. nut bolts, screws, lugs etc .
S&F in repair Heating element Square, threaded/ screwed type 1500 watt ISI marked complete all as specified and directed. Make Theeta/ Bajaj/ Hot top/Daspass or equivalent as approved.
S&F in repair Heating element cup type 1500 watt (ISI marked) complete all as specified and directed. Make - Bajaj/ Dass Pass/ Threeta or equivalent approved.
S&F in repair Heating element threaded/screwed type 2000 watt (ISI marked) suitable marked complete all as specified and directed. Make - Bajaj/Theeta/Hot top/ Daspass or equivalent as approved.
S&F in repair Heating element cup type 3000 watt (ISI marked) complete all as specified and directed. Make - Bajaj/Theeta/Hot top/ Daspass or equivalent as approved.
S&F in repair Thermostat suitable for geyser range 20 degree to 80 degree (ISI marked) complete all as specified and directed. Make-Thermoking/TTE,Elcon/ Expo/ Antriksh or equivalent approved.
S&F in repair PVC connection cotton braided heavy duty with brass union/coupling of length 450 mm with rubber washer suitable for 15 mm pipe complete all as specified and directed. .
S&F in repair Hot water outlet connection made of chromium plated flexible tubing for 15 mm bore pipe complete all as specified and directed.
S&F in repair Indicator lamp assembly with bulb with long lead suitable for geysers round or square type as sample kept in GE’s office complete all as specified and directed. .
S&F in repair PVC insulated flexible wire three core 2.5 sqmm copper conductor heavy duty complete all as specified and directed. .
S&F in repair Apperture plate assembly suitable for 25 ltrs geysers complete all as specified and directed.
S&F in repair Apperture plate assembly suitable for 50 ltrs geysers complete all as specified and directed.
S&F in repair Inner S.S. tank made out of 0.8mm(min.) for 25 ltrs geyser complete all as specified and directed.
S&F in repair Inner S.S. tank made out of 0.8mm(min.) for 50 ltrs geyser complete all as specified and directed.
S&F in repair Outer body with red, green indicator and bottom cover as per existing size & shape of capacity 25 ltrs geyser complete all as specified and directed.
S&F in repair 3 pin 15 amp plug top complete all as specified and directed. Make Anchor or equivalent as approved
M&L for painting of geysers after scraping, cleaning and preparing surface for painting and painting with two coats of white enameled paint of approved make and sign writing MES No etc of the following capacity geyser complete all as specified and directed
25 ltr capacity geyser
50 ltr capacity geyser
Repair of leakage of inner tank 25/50 ltr capacity geyser by brazing/soldering, testing including cutting of nut, bolt as required with gas welding cutter and providing new nut, bolts, washers etc complete all as specified and directed.
S&F in repairs Chromium plated brass stop cock 15 mm bore, screwed down, high pressure with crutch or butterfly handle complete all as specified and directed.
S&F in repairs MCB DP 32 amp, 230 volt, AC , 10 KA with indication & enclosure complete all as specified and directed.
S&F in repairs mild steel foundation nuts, bolts & washers heavy duty for fixing of geyser including grouting in wall complete all as specified and directed. .
M&L for Non return valve vertical type screwed for both ends with 15mm bore GI pipe. Complete all as specified and as directed.
S&F in repair fusible plug steel nut complete all as specified and directed.
S&F in repair Timmer suitable for Hevalls geyser (ISI marked) complete all as specified and directed.
Taking down carefully point wiring of any type complete for light, fan socket or power point with fittings & fixtures such as ceiling rose, electric fittings, holders, switches, sockets, regulators, wooden batten, surface conduit/casing caping/conceal etc. removing materials including accessories for taking credit and making good disturbed surface to match the existing complete all as specified & directed.
M&L for point wiring with FRLS PVC insulated unsheathed stranded copper conductor cable 1.5 Sqmm (nominal area) 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly drawn in and including non metallic PVC rigid, medium grade concealed conduit with all fixing accessories of 20mm dia, using new MS sunk terminal boxes of thickness not less 1.2mm, new 3mm thick laminated sheet cover with brass screw and cup washers with all accessories and making good to disturbed conceal surfaces complete all as specified and directed for the following :- Note:(a) Colour code of wire shall be strictly followed , Red for Phase , Black for neutral and green for earth wire (b) The unit rate quoted is deemed to be inclusive of cost of cutting chases in wall for providing concealed conduit and making good to match with existing finish/surface.
One light/fan/bell point controlled by one switch
One point for socket outlet 5 amps on independent board
One point for socket outlet 5 amp same board
One 3 pin socket outlet 15 amps, independent, with cables 2.5 sq. mm size on independent board.
S&F in repair ceiling rose surface type bakelite 65x50mm three terminal complete all as specified and directed.
S&F switch piano flush type, 5 amps, 230V AC,single pole, one way complete all as specified & directed.
S&F socket out let multipurpose suitable for 5 pin, 5 amp flush type complete all as specified & directed.
S&F in replacement of sheet metal enclosure single pole and neutral enclosure with a two pin and earth plug and socket along with one MCB, single pole of current rating 20 amps, C series 240 volts AC complete all as specified & directed.
S&F switch socket combination flush type 16 amps, single pole, one way ,230 volt complete all as specified & directed.
Taking down carefully sub main wiring of any nos of wire and size with earth wire on wooden batten/surface conduit/casing caping complete with its all accessories complete all as specified & directed.
M&L for concealed submain wiring using FRLS PVC insulated, unsheathed stranded copper conductor cable two single core of size 4.0 Sqmm of voltage rating upto and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 20 mm dia with all fittings and accessories along with one run of PVC insulated unsheathed stranded copper conductor of size 4 Sqmm as earth continuity conductor & making good to disturbed surface with CM 1:4 and colour wash complete all as specified & directed. Note:- (i) Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one length. (ii) The cost for cutting, chases required shall deemed to be included in the quoted unit rate.
M&L for concealed submain wiring using FRLS PVC insulated, unsheathed stranded copper conductor cable two single core of size 6.0 Sqmm of voltage rating upto and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 20 mm dia with all fittings and accessories along with one run of PVC insulated unsheathed stranded copper conductor of size 6.0 Sqmm as earth continuity conductor making good to disturbed surface with CM 1:4 and colour wash complete all as specified & directed. Note:- (i) Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one length. (ii) The cost for cutting, chases required shall deemed to be included in the quoted unit rate.
M&L for concealed submain wiring using FRLS PVC insulated, unsheathed stranded copper conductor cable two single core of size 10 Sqmm of voltage rating upto and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 20 mm dia with all fittings and accessories along with one run of PVC insulated unsheathed stranded copper conductor of size 10 Sqmm as earth continuity conductor making good to disturbed surface with CM 1:4 and colour wash complete all as specified & directed. Note:- (i) Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one length. (ii) The cost for cutting, chases required shall deemed to be included in the quoted unit rate.
S&F sheet metal enclosure for MCB's 240 volt 4 way single pole and neutral with 200 amps rated busbar double door on wall with and including suitable flat iron clamps duly grouted/ fixed flush in the wall complete all as specified and directed.
S&F sheet metal enclosure for MCB's 240 volt 8 way single pole and neutral with 200 amps rated bus bar, double door on wall with and including suitable flat iron clamps duly grouted/ fixed flush in the wall complete all as specified and directed.
S&F MCB single pole & Neutral, 32 amps rating, 240 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed.
S&F MCB single pole, 6 to 32 amps rating, 240 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed.
M &L for Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25M deep below normal ground level) with top edge of the plate not less than 1.5m below normal GL. Connected to galvanized earth lead wire 4mm dia by means of nut, bolt, check nut and washers including necessary excavation and earth work in soft/loose soil, GI protection pipe light grade 15mm bore for protecting the GI wire mesh funnel alternate layer of charcoal dust, and salt PCC pit 1:3:6 type C1 using 20mm graded stone aggregate and 50mm thick RCC 1:2:4 type BO using 20mm graded stone aggregate cover reinforced with 8 mm dia MS TMT bars 80mm C/C both ways complete all as specified and shown in Electrical plate No.3 SSR part-1 and connected to the earth point and testing complete all as specified and directed.
M & L for earthing with Galvanised steel earth plate 600 mm x 600 mm x 6.00mm thick buried directly in ground vertically in pit of depth not less than 2.25 mtr below normal ground level with top edge of the earth plate not less than 2.25 mtr below normal ground level connected to continuous (without joint) GI strip 32 mm x 6 mm as earthing lead by means of bolts, nuts, check nuts and washers of brass including gun metal or phosphorous bronze test point of size 75 x75 x 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screw all as specified including excavation and earth work and disposal of surplus soil including 40 mm bore GI tubing light grade and necessary fitting for protection of GI strip including laying of charcoal, dust and common salt PCC (1:2:4) type B-I (using 20 mm graded crushed stone aggregate) earth pit with 40 mm x 40 mm x 6mm mild steel angle iron frame ,40 mm thick pre- cast RCC cover (1:2:4) type B-1 ( using 20 mm graded crushed stone aggregate ) reinforced with 8mm diaTMT bar @ 75mm c/c both way with mild steel handle 12 mm dia round bar ,15 mm thick plastering in cement mortar (1:4) internally and upto 150mm below ground level externally, funnel with wire mesh 20mm dia medium grade GI pipe for watering complete all as shown on electrical plate No.3 of SSR Part- 1(2009) and connected in earth test including testing complete including disconnecting the old unused earthing complete all specified and directed. NOTE :- (i) The rates quoted shall also deemed to include the cost of Earth test point and earth strip and protection pipe upto 7.5 metre beyond the earth plates electrode and the earth resistance of the whole system shall be as near as possible to 0 but shall not in any case exceed one ohm. (ii) Any joints in earth lead from earth electrode to test point shall not be allowed / permitted.
DESERT COOLER
Opening of the Desert Cooler of any capacity and make, dismantling of complete items and its repair cleaning of serviceable parts, replacement of unserviceable or worn out parts, opening of Fan motor from their brackets, scraping out of old paint of complete body (internally & externally) of Desert Coolers making good, smooth surface and applying spray painting with one coat of synthetic enamel paint for external surfaces/ internal surface replacement of wooden wool pad - 3 Nos and fixing of Fan Motor and Pump, replacement of internal wiring and rotary switch with pump and Fan motor connection and testing after repair complete. Note: (i) Overhauling/Oiling of fan motor, Vertical pump replacement of Nuts, bolts washers/elbow, if required shall be deemed to be included in unit quoted rate. (ii) Cost of replacement of grass pad deemed to be included in quoted rate.(iii) Capacity of desert Cooler upto 2500 to 6000 cum/hrs.(i) Worn out or unserviceable spare parts to be replaced shall be measured and paid separately as supply only under respective item.(ii) Replacement of wool pad- 3 Nos. deemed to be included in quoted rate.(iii) Minor repair of chassis of brazing/welding work deemed to be included in unit rate.(iv) Provide PVC Sheathed cable of 23/.0076 up to 1.5 meter in replacement if required will be deemed included in the unit rate.
Supply only fan motor of 1/6 HP to 1/10 HP 230V AC electric of same capacity and same
Supply only Blade for kit Fan.
Supply only MS Bracket for kit Fan Motor
Supply only Submersible Pump set suitable for desert coolers of fractional H.P. Make : CG/Bajaj/Havells/Vansal or Summer cool/ Zolta (Khaitan).
Supply only Rotory Switch
Supply only Front Directional Grill
Supply only PVC pipe 10 mm dia flexible
Supply only Side panel made out of PGI Sheet 1 mm thick of size not less than 0.5 m width and 0.7m height complete.
Supply only Storage tank made out of PGI Sheet 1 mm thick of size not less than 0.7 m X 0.7M and height 0.2m complete.
Schedule of Credit (MINUS) Rs. 160698.00 B/F from Serial Page No. [Note : Details of items for schedule of credit is given on Srl Page No. ] This amount shall be automatically deducted to arrive at tendered sum
PITAMBARI TRADERS (BID ID -3135274)
Mohinder Pal and Sons (BID ID -3130106)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .