Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹61.7 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹66.3 L+₹4.6 L (7.52%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹66.6 L+₹4.9 L (7.97%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | Rejected-Technical | - | Rejected-Technical Rejected due to not uploaded scanned copy of DD as per Contractor letter No Nil dt 02 Sep 2025 |
| Sl No | Description | Qty | Unit | M/S TAHAA BUILDERS L3 | M/S MATOO INFRASTRUCTURES PVT. LTD. L2 | IR Infrastructure L1 |
|---|---|---|---|---|---|---|
| 1.00Notes :- (i) Please refer Schedule 'A' Notes given on serial page Nos 14 to 25 of CA. | ||||||
| 2.00LUMPSUM / OTHER PRE-PRICED PROVISIONAL SCHEDULE OF WORKS | ||||||
| 2.01 | Lumpsum price worked out by the contractor for BUILDINGS WORKS (DESIGN AND BUILD) as listed in Schedule 'A' Part-I brought forward from Serial Page No. 26(R) of CA. | 1 | Lumpsum | 43,15,000 ₹43,15,000 | 43,72,000 ₹43,72,000 | 42,00,000 ₹42,00,000 Lowest |
| 2.02 | Lumpsum price worked out by the contractor for INTERNAL ELECTRIFICATION WORK as listed in Schedule 'A' Part-II (Section-I) brought forward from Serial Page Nos 27(R) to 31(R) of CA. | 1 | Lumpsum | 2,60,000 ₹2,60,000 | 2,39,000 ₹2,39,000 | 1,20,000 ₹1,20,000 Lowest |
| 2.03 | Lumpsum price worked out by the contractor for INTERNAL WATER SUPPLY WORK as listed in Schedule 'A' Part-III brought forward from Serial Page Nos 32(R) of CA. | 1 | Lumpsum | 40,000 ₹40,000 | 30,000 ₹30,000 | 10,000 ₹10,000 Lowest |
| 2.04 | Lumpsum price worked out by the contractor for PROTECTIVE WORK as listed in Schedule 'A' Part-IV brought forward from Serial Page Nos 33 & 34 of CA. | 1 | Lumpsum | 7,90,000 ₹7,90,000 | 7,55,000 ₹7,55,000 | 6,00,000 ₹6,00,000 Lowest |
| 2.05 | Lumpsum price worked out by the contractor for ROAD AND PATH WORK as listed in Schedule 'A' Part-V brought forward from Serial Page Nos 35 of CA. | 1 | Lumpsum | 80,000 ₹80,000 | 75,000 ₹75,000 | 70,000 ₹70,000 Lowest |
| 2.06 | Lumpsum price worked out by the contractor for EXTERNAL WATER SUPPLY WORK as listed in Schedule 'A' Part-VI (Section-I) brought forward from Serial Page No. 36(R) of CA. | 1 | Lumpsum | 1,65,000 ₹1,65,000 Lowest | 1,70,000 ₹1,70,000 | 1,70,000 ₹1,70,000 |
| 2.07 | Lumpsum price worked out by the contractor for EXTERNAL ELECTRIC SUPPLY WORK as listed in Schedule 'A' Part-VII (Section-I) brought forward from Serial Page Nos 37(R) to 39(R) of CA. | 1 | Lumpsum | 3,45,000 ₹3,45,000 | 3,40,000 ₹3,40,000 | 3,00,000 ₹3,00,000 Lowest |
| 2.08 | Lumpsum price worked out by the contractor for SEWAGE DISPOSAL WORK as listed in Schedule 'A' Part-VIII brought forward from Serial Page Nos 40, 41(R) to 42(R) of CA. | 1 | Lumpsum | 2,10,000 ₹2,10,000 | 1,90,000 ₹1,90,000 Lowest | 2,00,000 ₹2,00,000 |
Tender Value
₹60.9 L
EMD Value
₹1.2 L
Closing Date
2 Sept 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Cdr, HQ 134 Wks Engrs
HQ 134 WE C/o 56 APO PIN-914134
Provn of 2 x double story guard post with guard room at nagdandi area Guard post no 10 C and D Nagdandi at Khundru under GE 861 EWS
2025_MES_721124_1
134 WE-34(T)/2025-26
Open Tender
Civil Works
Lump-sum
300 days
GE 861 EWS
As per Tender Documents
8 documents required · 8 mandatory
₹1,000
GE 861 EWS
₹1.2 L
25 Sept 2025
18 Jul 2025
4 Sept 2025
18 Jul 2025
2 Sept 2025
14 Aug 2025
18 Jul 2025 - 25 Jul 2025
Amount
Notes :- (i) Please refer Schedule 'A' Notes given on serial page Nos 14 to 25 of CA.
Lumpsum price worked out by the contractor for BUILDINGS WORKS (DESIGN AND BUILD) as listed in Schedule 'A' Part-I brought forward from Serial Page No. 26(R) of CA.
Lumpsum price worked out by the contractor for INTERNAL ELECTRIFICATION WORK as listed in Schedule 'A' Part-II (Section-I) brought forward from Serial Page Nos 27(R) to 31(R) of CA.
Lumpsum price worked out by the contractor for INTERNAL WATER SUPPLY WORK as listed in Schedule 'A' Part-III brought forward from Serial Page Nos 32(R) of CA.
Lumpsum price worked out by the contractor for PROTECTIVE WORK as listed in Schedule 'A' Part-IV brought forward from Serial Page Nos 33 & 34 of CA.
Lumpsum price worked out by the contractor for ROAD AND PATH WORK as listed in Schedule 'A' Part-V brought forward from Serial Page Nos 35 of CA.
Lumpsum price worked out by the contractor for EXTERNAL WATER SUPPLY WORK as listed in Schedule 'A' Part-VI (Section-I) brought forward from Serial Page No. 36(R) of CA.
Lumpsum price worked out by the contractor for EXTERNAL ELECTRIC SUPPLY WORK as listed in Schedule 'A' Part-VII (Section-I) brought forward from Serial Page Nos 37(R) to 39(R) of CA.
Lumpsum price worked out by the contractor for SEWAGE DISPOSAL WORK as listed in Schedule 'A' Part-VIII brought forward from Serial Page Nos 40, 41(R) to 42(R) of CA.
Lumpsum price worked out by the contractor for SITE CLEARANCE, EXCAVATION & EARTHWORK as listed in Schedule 'A' Part-IX brought forward from Serial Page No. 43 of CA.
Schedule 'A' Part-II (Section-II) Internal Electrification Work
S&F security light brackets with 1.50 mtrs long 40mm dia light grade galvanised iron pipe with 30°bend including flat iron clamps, nuts, bolts and washers to brace the same properly duly painted with two coats of silver coloured synthetic enamel paint over one coat of red oxide primer and making good to disturbed surfaces to match with existing, complete all as specified and directed
S&F LED 9 watt pin type bulb complete all as specified and directed.
Material and labour earthing complete with galvanised steel earth plate electrode 60x60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron and 20mm GI pipe for earth lead protection and 40mm GI pipe for watering etc all as shown in electrical plate No 03 of SSR Part-I, connected to earthing test point including necessary earth work, 1:3:6 C1 PCC chamber, 1:2:4 B-1 PCC cover with 8mm dia steel bars at 100 mm C/C suitable size of GI pipe for earth lead protection and watering, water funnel etc, complete all as specified and directed including testing on completion.
Schedule 'A' Part-VI (Section-II) External Water Supply Work
Boring of road manually for laying 100/ 50/ 40 mm dia GI pipe including making good the disturbed surface complete all as specified and directed.
M&L cutting existing CI/ GI pipe line of 20mm to 80mm dia and inserting tee and tapping new connection with all accessories complete all as specified and directed
Schedule 'A' Part-VII (Section-II) External Electric Supply Work
S&F outdoor type SMC junction box of size 170x170x105mm one piece moulded SMC door hinged fixed base with hinged right or left side and fixed to the foundation pole with suitable fixing arrangement bus bar with single electrolytic aluminium for both phase and neutral supported on FRP insulator and cut out complete fixed on the pole with suitable inlet and outlet, provision for cable connection, MCB SP 6 Amps rating ‘B’ curve for controlling the pole light, including necessary connection complete all as specified and directed.
Supply & fixing cable PVC insulated flexible copper conductor of size 1.5Sqmm 3 core cut to pieces all as required, drawn into conduit/ pipe fixed to wall or pole complete all as specified and directed
M/S MATOO INFRASTRUCTURES PVT. LTD. (BID ID -3414555)
M/S TAHAA BUILDERS (BID ID -3414527)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .