| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.5 LAccepted-AOC 2 10 PANCHANANTALA ROAD KOLKATA 700 041 | KOLKATA | WEST BENGAL | 700041 | L1 | Accepted-AOC Being lowest bidder and reasonable | |
| 2 | L2₹52.5 L+₹2.7 L (5.33%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹52.9 L+₹3.0 L (5.99%)Rejected-Finance 8 28 BIJOYGARH P O JADAVPUR KOLKATA 700 032 | KOLKATA | WEST BENGAL | 700032 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹53.5 L+₹3.6 L (7.27%)Rejected-Finance G C ROAD ABDUL LATIF ROAD PO TITAGARH P S RAHARA KOLKATA 700 119 | 24 PARAGANAS NORTH | WEST BENGAL | 700119 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹53.7 L+₹3.8 L (7.72%)Rejected-Finance 7 11 1 BROJONATH LAHIRI BISHNUPUR SOUTH 24 PGS WEST BENGAL 743503 | 24 PARAGANAS SOUTH | WEST BENGAL | 743503 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹45.4 L
EMD Value
₹90,800
Closing Date
28 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
SPL REPAIR TO BLDG NO O-1/G AND GARAGES NEAR IFA BLDG ALONGWITH CONNECTED SERVICES FORT WILLIAM UNDER GE (FW) KOLKATA
2023_MES_579278_1
8980/FW/E8
Open Tender
Civil Works
Item Rate
180 days
GE(FW) Kolkata
Ref tender documents
7 documents required · 7 mandatory
₹500
GE(FW) Kolkata
₹90,800
16 Mar 2023
6 Feb 2023
1 Mar 2023
6 Feb 2023
28 Feb 2023
21 Feb 2023
Amount
SCHEDULE 'A' PART-I (B/R WORKS) Surface excavation not exceeding 30 cm deep and averaging 24cm deep and getting out in soft/loose soil complete all as specified and as directed.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm , watering , and removing surplus soil to a distance n exc. 50m and making good surface in soft/loose soil.
Excavation in trenches n exc 1.50 m wide and n exc 1.50m depth for foundation etc or for shafts, wells, cess pits, manholes, pier holes etc not exc 10 Sqm on plan and not exc. 1.50 Metre in depth and getting out as in soft/loose Soil, complete all as Specified and as directed.
M&L for Hardcore of broken stone of gauge n.exc 63mm deposited spread and levelled in layers n.exc 15cm thick watered and rammed to a true surface all as specified
Removing excavated materials not exc 50 m and depositing where directed at a level not exc 1.50 m above the starting point complete all as Specified and as directed.
Returning filling in incl spreading , levelling , watering and well ramming in layers not exc 25 cm as in soft/ loose Soil, complete all as Specified and as directed.
Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches, pillars etc complete all as specified and directed.
Dismantling of floor, hearth or wall tiling incl cement mortar bedding (but not backing) removing tiles from site and rubbish off the premises complete all as specified and directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed.
Demolition of plain cement concrete over roof of buildings including screed bed and roof treatment and removal of rubbish complete all as specified and directed.
Taking down cement plaster on brick or concrete surfaces incl racking out joints, hacking for key, scrubbing down with water etc. all as specified and directed.
Taking down chowkhats or frames with shutters (w/o taking off shutters from the frames) area exceeding 1.5 Sqm and not exceeding 4 Sqm each and removing from the site complete all as specified and directed.
Taking down shutters of any description area exceeding 1.00 sqm and not exceeding 2.00 Sqm each and removing from the site complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping, clean and washing down with water to remove dust etc., all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting any gauge or any thickness in roof covering including stacking serviceable materials of re-use and removing unserviceable materials complete all as specified and directed.
M & L for brick work using old size fly-ash bricks straight or curved on plan exec 6 metre mean radius, built in cement mortar 1:6 complete all as specified and directed.
M & L for brick work using old size fly-ash bricks straight or curved on plan to any radius in half brick wall, built in cement mortar 1:4 complete all as specified and directed.
M&L for dubbing out cement plaster (1:4), average 10 mm thick on irregular faces of walls (when specially ordered in writing) complete all as a specified and as directed
M&L for rendering 15 mm thick built in cement mortar (1:4) on fair faces of brick work or concrete surfaces finished even & smooth (without using extra cement) and mixed with water proofing smart care damp block compound 2K of Make: Asian paint as per manufacturer's instructions including necessary scaffolding in any position, complete all as specified and directed.
M & L for 15 mm thick plastering in two layers, 10 mm + 5 mm in cement mortar 1:4, top layer of 5 mm thickness mixed with with water proofing compound (@ 200 ml per bag of cement or as per manufacturer's instructions) on brick/stone walls or concrete surfaces finished even and fair (upto any height) for external surfaces complete all as specified and directed. Note : Water Proofing compound shall be measured and paid separetly as "Supply only".
M&L for rendering 5mm thick on ceiling surfaces in cement mortar 1:3 and finished even and smooth without using extra cement, with and including necessary scaffolding, complete all as specified and directed.
Supply only liquid water proofing compound all as specified and as directed.
M&L for cement concrete (1:2:4) type B1, using 20 mm graded stone aggregate, as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating and necessary formwork complete all as specified and directed.
M&L for Second class hardwood plain solid straight chowkats and frames wrought, framed rebated on the solid rounded or chamfered put together with glue pinned at joints all as specified.
S&F 35mm thick Factory made 2nd class hard wood glazed & skeleton shutters, open rebated and prepared to receive glass, gauge etc.(with sash bars) edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass/gauge etc, size of members of shutters as specified in SSR Part-I section 8, clause 8.20(a) complete all as specified and directed.
S & F PVC solid door frame of size 50 x 47 mm made out of 5 mm thick prelaminated single side PVC sheet reinforced with MS square tube complete all as specified and as directed.
M&L for Factory made solid PVC moulded door shutter, 28 to 30 m thick(stiles) with 2,4 or 6 raised panel design with 2 mm thick moulded PVC sheet on the front face & 2 mm plain colour PVC sheet on back face with particle board core complete all as specified and directed.
M&L for Providing and fixing factory made single extruded WPC (Wood Polymer composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer- In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)
Supplying and installing uPVC- Sliding windows/doors made out of lead free green profiles having a worldwide presence with a GREENLINE mark having two tracks and two sashes (shutters) with frame dimension of 58mm x 49mm and sash dimension of 61mm x 47mm x 37mm with corners fusion welded, fully reinforced with Galvanized steel of 1.2 mm.The physical properties of the profiles like Vicat softening temperature, density, tensile strength, hardness, weatherability, impact strength and Modulus of Elasticity should be tested in accordance with ASTM/DIN-ISO standards and the thermal conductivity as per IS standards.The profile manufacturer should be a certified member of IGBC and should have extrusion facility in India and the windows to be assembled and installed by an authorised fabrication partner . Application of Silicon sealant from Inside / Outside with Make: Dowcorning / GE or equivalent. The profiles should be of an international brand having factories in multiple countries and having a warranty of 20 years. The profiles should conform to BSI Quality Management System ISO 9001-2015 and Environmental Management System ISO 14001-2015 and also scaffolding as required for fixing, complete all as specified and directed. Make: Kommerling or equivalent other approved makes as specified in particular specifications
Supplying and installing rectangular uPVC louver windows fixed and exhaust made out of lead free green profiles having a worldwide presence with a GREENLINE mark with frame dimension of 58mm x 36mm for window with aluminium powder coated frame work and glass blades for louvers and corners fusion welded, fully reinforced with Galvanized steel of 1.2 mm.The physical properties of the profiles like Vicat softening temperature, density, tensile strength, hardness, weatherability, impact strength and Modulus of Elasticity should be tested in accordance with ASTM/DIN-ISO standards and the thermal conductivity as per IS standards.The profile manufacturer should be a certified member of IGBC and should have extrusion facility in India and the windows to be assembled and installed by an authorised fabrication partner . Application of Silicon sealant from Inside / Outside with Make: Dowcorning / GE or equivalent. The profiles should be of an international brand having factories in multiple countries and having a warranty of 20 years. The profiles should conform to BSI Quality Management System ISO 9001-2015 and Environmental Management System ISO 14001-2015 and also scaffolding as required for fixing, complete all as specified and directed. Make: Kommerling or equivalent other approved makes as specified in particular specifications
Supply & fixing 100 mm stainless steel butt hinges (medium weight) cold rolled complete all as specified and directed.
S&F 200 mm long aluminium anodised barrel tower bolts extruded section, ISI marked complete all as specified and directed.
S&F 300mm long aluminium anodised sliding bolt with hasp, staple (bolt type) and fixing clips or sheets cast of extruded section and fixing bolts and sliding bolts of extruded section ISI marked complete all as specified and directed.
S&F 150 mm long aluminium anodised handles (cast type) ISI marked complete all as specified and directed.
S&F Floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring (overall length of cover plate 150mm) complete all as specified and directed.
S&F stainless steel wire cloth of 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed.
S&F 3 mm thick plain sheet glass ordinary quality and glazing with oil putty or wooden beads in square n.exc 0.50 Sqm in each pane complete all as specified and directed.
S&F 5 mm thick toughned glass as in hinged doors, partitions, windows, automatic doors and similar works including cutting to shape, drilling holes required, complete all as specified and directed.
S&F steel rolling shutter without ball bearing as specified including top cover, anchoring rod, hasp and staple and shop coat of primer, erected in position as indicated complete gear operated type, with bevel gear box and crank handle, thickness of lath 1.25 mm, as in repairs complete all as specified and directed.
Supply and fix ball bearing for rolling shutter, all as directed.
M&L for plain cement concrete (1:5:10) type E2 using 40 mm graded aggregates in foundation filling and mass concrete complete all as specified and directed.
M & L PCC 1:2:4 type B 2 (using 40 mm graded aggregate) as in foundation filling and mass concrete complete.
M&L cement concete, type B1, 1:1.5:3 (using 20 mm graded stone aggregate) for mass concreting complete all as specified and directed.
M&L for providing precast cement concrete (1:2:4) type B1 using 20 mm graded aggregates set in cement mortar 1:4 as in landings, cover slabs (for manhole etc.) chullah hoods, chajjas, water troughs, shelves and similar articles with plain faces complete all as specified and directed.
M&L for 50 mm thick plain cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as in sub base of floors etc, finished evan and fair complete all as specified and directed.
M&L for 25 mm thick plain cement concrete (1:2:4) type B-1 (using 12.50mm graded stone aggregate) as in sub base of floors etc, finished evan and fair complete all as specified and directed.
M&L cement concrete type C2 (1:3:6) using 40 mm graded stone aggregate, 75 mm thick as in plinth protection, laid in alternate bays, finished even and smooth without using extra cement, complete all as specified and directed.
M&L for machine cut kota stone slab flooring 18-20 mm thick, laid over and including 20mm thick screed bed in cement mortar (1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and directed.
M&L for laying and fixing Kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar laid over 10 mm thick rendering in cement mortar 1:4 and jointed etc complete all as specified and directed.
S&F non-skid ceramic coloured tiles (square/ rectangular), 7 to 8 mm thick, area of each tile exceeding 0.18 Sqm but not exceeding 0.36 Sqm, as per approved design, set and jointed in neat cement slurry in floors and pointed in white or coloured cement to match the shade of tiles, laid over and including screed bed 15mm thick in cement mortar 1:4 complete all as specified and directed.
All as per item No.53.00 above, but in skirting on vertical surfaces over and including rendering 10 mm thick in cement mortar 1:3 complete all as specified and directed.
S&F non-skid ceramic coloured tiles (square/ rectangular), 7 to 8 mm thick, area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, as per approved design, set and jointed in neat cement slurry in floors and pointed in white or coloured cement to match the shade of tiles, laid over and including screed bed 15mm thick in cement mortar 1:4 complete all as specified and directed.
S&F glazed coloured ceramic tiles in vertical surface, as per approved design, size 300 X 450 X 7 mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles, laid over and incl 10mm thick screed bed in cement mortar 1:3 complete all as specified and directed.
M&L for heavy duty coloured ceramic floor / paving tiles of size 300 x300x 10 mm thick in floor etc set and jointed in near cement slurry and pointed in white or coloured cement to match the shade complete including 20 mm thick screed bed in cement mortar 1:6 complete all as specified and directed of Make : Johnson model Endura or equivalent model in other approved makes.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3, including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm) including making drainage opening wherever required complete all as specified.
M&L for Rolled mild steel sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Gde Fe-410-W (Gde-E 250) quality-B complete all as specified and directed. (NOTE: Quoted rates shall be deemed to include for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete)
S&F 0.50 mm thick TCT (total coated thickness) pre-coloured galvalume sheets with minimum base metal thickness of 0.45 mm, single skin high rib/multi rib profile galvalume sheeting having 1000-1020 mm width and 28-30 mm high crest @ maximum 250-255 mm pitch (centre) with sheets manufactured out of 0.50 mm this TCT (total coated thickness) high tensile galvalume sheets having tensile strength 550 MPA with 18-20 micron top coat over 5 micron primer and 8-10 micron alkyld backer zinc aluminium alloy AZ-150, sheets having a dip metallic zinc (43.5%0 aluminium (55%) & silicon (1.5%) with total mass coating of 150 gms/sqm on both sides, having wide pans with minimum 3 small stiffening ribs for effective water shedding and special male/female ends with full return legs on laps for purlin support and fixed as per existing profile of roof complete all as specified and directed.
S&F 0.56 mm thick plain aluminium sheeting alloy 31000 H4, as in ridges, hips, valley gutter, drip and straight flashing, complete all as specified and directed. .
M&L Preparing new Surfaces of walls and applying Three coats of white wash complete all as specified and as directed.
M&L Preparing of old treated Surfaces of walls and applying Three coats of white wash complete all as specified and as directed.
M&L Preparing new Surfaces of ceilings and applying Three coats of white wash complete all as specified and as directed.
M&L for preparation of new plastered of wall surfaces and applying two coats of acrylic distemper finished with rollers over a coat of alkali resistant primer applied over 3 mm thick wall care putty complete all as specified and directed.
M&L for preparation of new plastered of Ceiling surfaces and applying two coats of acrylic distemper finished with rollers over a coat of alkali resistant primer applied over 3 mm thick wall care putty complete all as specified and directed.
M&L for complete removal of existing treatment on walls and applying two coats of acrylic distemper finished with rollers over a coat of alkali resistant primer applied over 1.0 mm thick wall putty complete all as specified and directed.
All as per item No.67 above, but on Ceilings
M&L for complete removal of existing treatement of walls and applying Two coats of plastic emulsion paint with rollers over a coat of primer and 2mm thick wall care putty, complete all as specified and directed.
M&L for preparation of new surfaces of walls and soffit of chajja, roof slab etc., by cleaning, brooming, rubbing and scrapping as required using broom, emery paper, putty blade/scraper as applicable to make the surface free from protrutions, loose particles, dust etc including necessary safety & protective measures such as safety belt, headgear etc, finishing the surface with 2 mm thick exterior wall putty (in two layers) for smooth finish and finishing with two coats of weather proof exterior emulsion paint over a coat of suitable exterior primer of approved make using airless spray technology capable of operating single spray gun with hose of adequate length and necessary scaffolding for upto 4 storey building height complete all as specified and directed.
M&L for preparation of old painted wooden surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of primer after complete removal of old paint by paint removers or burning off by blow lamps and cleaning with scrapers, any number of coats, complete all as specified and as directed.
M&L for preparation of new steel and iron surfaces of any description, exc 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of primer, complete all as specified and directed.
M&L for preparation of new steel and iron surfaces of any description, n.exc 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of primer, complete all as specified and directed.
M&L for preparation of old painted steel & iron surfaces of any description over 10 cm width or girth and applying one coat of aluminium paint, complete all as specified and as directed.
M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking bending spirally for lintels and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, all as specified.
M&L mild steel work in tubular trusses including special shaped washers etc complete using ERW or induction butt welded tubes conforming to IS-1161:2014 grade St-240 complete all as specified and directed. (NOTE: Quoted rates shall be deemed to include for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete)
S&F Mild steel wind ties for roof including securing bolts, posts including cutting tops to shape as directed, drilling holes, notching for wire, etc flat iron fillets including all necessary drilling, bolting or rivetting etc and similar work conforming to Fe 290 Gde E-165.
S&F rolled mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment confirming to FE-410-W (Gde E-250) complete all as specified and directed.
M&L Bands, straps, supports or stays for rainwater, ventilating, pipes, including bolts, if required hooks (stays ) heavy for large gates hook and pintle hinges large hasps and staples, chains hand made sliding bolts, clamps, hold fasts, plain angle cleats for securing purlins to wood trusses or rafters knee piece inserts two way and three way straps plate washers and similar small articles conforming to fe-290 Gde E-165 complete all as specified and directed.
M&L for Mild steel framed works such as grills, gratings etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings, framework of water tanks and similar works conforming to Fe-290 Gde E-165 complete all as specified and directed.
M&L in repair for Expanded metal, cut to length, bent to shape required and tying with and including anealed mild steel wire not less than 0.9 mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members, weight n exc 4 Kg per sqm complete all as specified and directed .
Removal of existing water proof treatment of any description from roof surface including cement plaster/screed bed carefully from the surfaces, roughening concrete surfaces and cleaning the roof surfaces by brushing, sweeping and scrubbing down with water and removal of debris complete all as specified and as directed.
M&L for brushing neat cement slurry with 2.75 Kg of cement per Sqm on roof complete all as specified and directed.
M&L for Providing Cement Concrete, 25 mm thick, type B-0, 1:2:4 (using 12.50 mm graded Stone aggregate), as in roof padding mixed with water proofing compound and the concrete surfaces is to be finished even and fair (without using extra cement) complete all as directed by Engineer - in - charge. (NOTE: WPC Shall be measured & paid separately)
M&L 10 mm thick screed bed in cement mortar 1:3 over roof mixed with water proofing compound as per manufacturer's instruction complete all as specified and directed. (NOTE: WPC will be measured and paid separately)
M&L for water proofing treatment on existing cleaned RCC roof with the following specifications and manufacturer's instruction complete all as specified and directed :- (i) Preparing and cleaning of fully dried surfaces as per IS 3067-1966. (ii) Applying bitumen primer conforming to IS:3384-1968 over the cleaned base @ 1.2 litre per sqm. (iii) Providing a layer of 3 mm thick APP modified pre-fabricated five layer, weight not less than 3.6 kg/sqm, black finished reinforced with non-woven polyster matt membrane with butane torch application. Overlap shall be minimum 100 mm on the transverse direction and 75 mm on longitudinal direction. (iv) Applying two coats of bitumen based UV reflective paint with aluminium finish @ 0.20 litre per sqm over APP membrane.
Supply only liquid Water Proofing Compound, conforming to IS and as approved, complete all as specified.
S&F in repair 15mm bore galvanised steel tubing (medium grade) with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed.
S&F in repair 20mm bore galvanised steel tubing (medium grade) with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed.
S&F in repair 25mm bore galvanised steel tubing (medium grade) with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed.
S&F in repair Gun metal gate or globe valve, with iron wheel head, screwed both ends for iron pipe and fixed for 20 mm bore pipe complete all as specified and directed.
S&F in repair Gun metal gate or globe valve, with iron wheel head, screwed both ends for iron pipe and fixed for 25 mm bore pipe complete all as specified and directed.
Supply, hoisting and fixing rotational moulded polyethylene water storage tank (cylindrical vertical type with closed top) of capacity 1000 Litres, multi-layered (ISI marked), with GI tank nipple & cover, hoisted and fixed in position all as specified in SSR Part-I incl dismantling of existing unsv tank complete all as specified and directed.
S&F in repair 20 mm bore Ball brass valves, high pressure, with HDPE float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. (MAKE : PRAYAG, Cat No. B-152 or equivalent model in JEXON / POLYTUF / SHAKTI)
M&L for cutting holes in brick wall exceeding half brick but not exc one brick thick walls for inserting hold fasts for mild steel grills and making good dismantled portion in cement concrete 1:2:4 type B1 (using 20 mm graded aggregates) including necessary formwork and making good surfaces as per existing finishes complete all as specified and directed.
Forming jambs etc to openings, including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, in cement mortar 1:4 complete all as specified and directed.
making good under cills or over arches, lintels and bressumers including all pinning when necessary, in cement mortar 1:4 complete all as specified and directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) 150 mm set in cement mortar, including breaking and removal of bedding and hunching, complete all as specified and as directed.
Supply and laying 150 mm bore reinforced concrete pipe of Class NP-3, laid and jointed with jute & cement mortar 1:2, complete with collars all specified and as directed.
M&L concrete bed to drain pipe including packing under and haunching against the side of drain pipe after laid and tested in PCC 1:3:6 type C2 for 150 mm bore pipes, complete all as specified and directed.
Cutting into existing manholes for connecting new drains, making good to pipes and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate), finished smooth and reforming benching for 150 mm bore pipe as required and as directed by the Engineer-in-Charge.
Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches of 100 mm internal dia complete all as specified and as directed.
S&F Cast iron (sand cast) soil, waste and vent pipes 100 mm bore of any length with or without ears with cement joints all as specified laid in trenches or in floors complete all as specified and directed.
All as per item No 103 here in before, but 100mm bore fixed to wall
S&F 100mm bore CI bend (any radius), diminishing pieces or tapers (larger bore measured), complete all as specified and directed.
S&F 100mm bore CI bend (any radius), diminishing pieces or tapers (larger bore measured) fitted with ovel access door, complete all as specified and directed.
S&F 100mm bore CI branch pieces double (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches, complete all as specified and directed.
S&F 100mm bore CI Sanitary connection socket to fit WC outlet, , complete all as specified and directed.
M&L for 100 mm dia cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete type B1(1:2:4) complete all as specified and directed.
S&F in repair Vitreous China Wash Hand Basin 550x400mm in size, White (Flat Back or Angle Back Type) with 32mm dia Brass Chromium Plated Waste Fitting, making good disturbed Surfaces in Cement Mortar 1:3 complete all as specified and directed. (MAKE : CERA, Cat No: S2040119 / HINDWARE, Cat No. 10100 / PRAYAG, Cat No: 4645 / ASIAN PAINTS, Cat No: PN-03-X) (NOTE: Waste coupling and Waste pipe shall be measured and paid seperately)
S&F in repair vitreous China Squatting pan ‘Orissa’ pattern, size 580 X 440 mm, white, with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, etc and including making good to floor, complete all as specified and directed. (MAKE : CERA, Cat No: S3010109 / HINDWARE, Cat No. 20042 / PRAYAG, Cat No: 4054 / ASIAN PAINTS, Cat No: WM-32-X)
S&F in repair 10 ltrs capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and incl with flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern complete all as specified and directed. (MAKE : PARRYWARE, Model : Slim line Economy / HINDWARE, Model : Sleek Plus / CERA, Model : Corona / PRAYAG, Model: SMART /ESSCO, Cat No: WHE-WHT-183NL)
S&F Vitreous china, white, urinal, full stall type, flat back with grating and union for discharge pipe (excl flush pipe, flushing cistern and waste pipe) incl providing and fixed plugs, bedding urinal against wall in cement mortar 1:2 and securing urinal to plugs with and incl 60mm long brass screws, pointing around urinal back in cement; fixing flushing cistern with brackets, flush pipe, grating and union for discharge pipe complete all as specified and directed. (Make of Urinal : Parryware, Model : Aquaseal N/ CERA, Model: CARYS / HINDWARE, Model: CORTO)
S&F in repair PTMT shelf, 450 mm long complete all as specified and directed. (Make : PRAYAG, Cat No : 191 or equivalent make as approved by GE).
S&F in repair 32 mm bore PVC corrugated waste pipe, 800 mm long for wash hand basins complete all as specified and directed. (Make: PRAYAG, Cat No: 327 or equivalent make as spproved by GE)
S&F in repair 32 mm bore PVC collapsible waste pipe, 800 mm long complete all as specified and directed. (Make: PRAYAG, Cat No: 3272 or equivalent make as spproved by GE)
S&F in repairs brass chromium plated grating of size 102mm dia with waste holes, complete all as specified and directed. (Make : PRAYAG, Cat No: FT-04 or equivalent make as approved by GE)
S&F in repair Chromium plated brass Angular stop cock, fancy type, concealed type with wall flange fixed to 15 mm bore iron pipe complete all as specified and directed. (Make : JAQUAR, Cat No: KUP-35053PM / PARRYWARE, Cat No: T3097A1 / CERA, Cat No: F1005201 / PRAYAG, Cat No: 9410 / HINDWARE, Cat No: 320006 )
S&F Tubular towel rail (normal range), 20mm dia, 600 mm long between flanges including brass chromium plated, complete all as specified and directed. (MAKE : Essco, Cat No : AEC-1111 / PRAYAG, CaT No: BA-40 / ESS ESS, Cat No : AC-701 / SOMANY, Model: ETHER)
S&F in repair Chromium plated brass Bib cock with wall flange, fancy type, long body, fixed to 15 mm bore of Iron pipe complete all as specified and directed. (Make : Essco, Cat No: SQT-512KN / Ess Ess, Cat No: T-105A / PRAYAG, Cat No: 7209 /SOMANY, Model: ETHER)
S&F in repair 15mm bore Chromium plated brass Pillar tap, fancy type. with areator, fixed to wash hand basin, complete all as specified and directed. (Make : Essco, Cat No: SQT-507KN / ESS ESS, Cat No: T-101 / PRAYAG, Cat No: 7202 / SOMANY, Model: ETHER)
S&F in repair 15mm bore push button auto closing concealed urinal flush valve with wall flange, fancy type chromium plated, complete all as specified and directed.
Chipping of unsound /weak concrete materials including cover plaster from RCC structural member i.e. slabs, beams, columns, lintel, chajja, fins, facia etc. of 50 mm average thickness (Any storey/ height of building/ structure) including tapering all edges, making square shoulders of cavities by air or sand blasting etc and cleaning of exposed concrete surface and reinforcement bars, lightly picking materials by air blasting or sand blasting including removal of foreign materials, loose concrete/aggregate etc and disposal of all debris out side of MOD land and complete all as specified and as directed. (NOTE: Measurement shall be considered for the surface area of RCC member)
M&L for applying chloride free rust removing chemical on rusting steel reinforcement bar as per manufacturer's specification and removing all rust from steel reinforcement bar by wire brush & sand/emery paper (after 24 hours of application of rust remover) and cleaning the area thoroughly by water with the help of pressure jet and allowing it to dry and making the reinforcement bar totally rust free (for any storey/ height of building/ structure) complete all as specified and as directed. (Make of Rust removing chemical :- Reebaklens RR of FOSROC or equivalent product other makes specified in tender) (NOTE: Surface area of cleaned steel reinforcement shall be measured for payment)
M&L for introducing new mild steel TMT reinforcement bars for structural connection in RCC beams, columns, lintel and slabs (for any storey/ height of building/ structure) including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm and up to 200mm including power drilling, fixing the reinforcement in position using epoxy, cleaning of loose dust by blowing air, sealing with epoxy cartridges, plastic nozzles etc as per manufacturer's instructions etc all as specified and directed. (Make of epoxy chemical :- Lockfix E75 of FOSROC / Hilti HY 150 or equivalent product other makes specified in tender) (NOTE: Reinforcement bars shall be paid separately)
M&L for preparation of old existing corroded and new introduced reinforcement surface (at any storey/ height of building/ structure) by brush and application of two component epoxy based zinc rich primer, of minimum specific gravity 1.75, adhesive bond strength with steel as 1.50N/mm2, as a protective coating to steel reinforcement bars in concrete with total zinc content in dry film >90% by volume and DFT per coat >50 microns complete all as specified and directed. (Make- Nitozinc primer of FOSROC or equivalent product in other makes specified in tender) (NOTE: Surface area of steel reinforcement shall be measured for payment)
M&L for applying a coat of epoxy bonding agent on existing concrete surfaces, with mixed density 1.48 Kg/litre and adhesive bond strength>2.50 MPs, mixed and applied as per manufacturer's specifications complete all as specified and directed. (Make- Nitobond EP of FOSROC or equivalent product in other makes specified in tender) (NOTE: Measurement shall be considered for the surface area of RCC member.
M&L for applying shrinkage controlled, polymer modified, fibre reinforced cementitious repair mortar, as per manufacturers instructions to get a compressive strength of 35 MPA after 28 days, finishing surfaces even and smooth complete all as specified and directed. (Make- Rendroc SP 40 of FOSROC or equivalent product in other makes specified in tender) (NOTE: Measurement shall be considered for the surface area of RCC member.
GENERAL NOTES FOR ITEM NO.124 TO 129 :- (i) The work shall be got executed through authorised applicator of the chemical manufacturers. Necessary documents to this effect shall be obtained from manufacturer and submitted to the Engineer-in-Charge. (ii) Contractor shall provide additional manpower, resources, preparatory work etc. required for execution of the work as required by the authorised applicator. Quoted rates are deemed to be inclusive of the above aspects. No extra claim shall be admissible during execution of work on this account.
SCHEDULE 'A' PART-II (ELECTRIFICATION WORKS) Taking down copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc for reuse or removing from site and making good disturbed surface of walls, floors etc. complete all as specified and directed.
Taking down of Old MCB DB any type any size including MCCB/RCCB/MCBs and disconnecting the serviceable MCBs and keeping in safe custody for reuse at site or removal from site complete all as specified and directed.
Taking down of old Submain wiring any type including batten/ conduit/ casing at any indicated situation complete all as specified and directed.
M&L for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC conduit complete with all fittings and accessories (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLSH PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly,. Complete all as specified and directed. for one light point / bell point/ceiling fan/exhaust fan point controlled by one way switch. (NOTE :- (i) Where tube light fitting is to be fitted/suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Point wiring shall be measured from switch board/DB to outlets only. Main circuit wire of the switch board/DB shall be measured and paid separately as sub main wiring of required size depending upon the load of that switch board. (iii) Quoted rate shall be exclusive of the cost of terminal box and laminate cover which shall be measured separately.
All as per item No 91 here-in-before, but for one 5 pin 5/6 amp socket out let point in the same switch board of light points (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
All as per item No 91 here-in-before, but for one 5 pin 5/6 amps multi socket outlet point in independent board (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
All as per item No 91 here in before, but using 2.5 sqmm PVC insulated unsheathed multi strand copper cable (1100 V) FRLSH for line conductor and 1.5 Sqmm PVC insulated unsheathed multi strand FRLSH copper cable (1100 Volts) for earth continuity wire for one 15/16 amp multi socket out let independent (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
S&F Modular Switch 1 way, 6 Amps, 1 module complete all as specified and directed.
S&F Modular Switch 1 way, 16 Amps, 1 module complete all as specified and directed.
S&F Modular Socket 6 Amps, 2/3 pin combined, 2 module complete all as specified and directed.
S&F Modular Socket 6/16 Amps, 2/3 pin combined, 2 module complete all as specified and directed.
S&F Modular Blank plate 1 module, complete all as specified and directed.
S&F Modular Bell push 6A, 1 module, complete all as specified and directed.
S&F Modular Fan step regulator, 120 watt, 2 module complete all as specified and directed.
S&F Modular White cover plate with frame 3 module complete all as specified and directed.
S&F Modular White cover plate with frame 4 module complete all as specified and directed.
S&F Modular White cover plate with frame 6 module complete all as specified and directed.
S&F Modular White cover plate with frame 8 module complete all as specified and directed.
S&F Modular White cover plate with frame 12 module complete all as specified and directed.
S&F Modular type Metal Flush box 3 module complete all as specified and directed.
S&F Modular type Metal Flush box 4 module complete all as specified and directed.
S&F Modular type Metal Flush box 6 module complete all as specified and directed.
S&F Modular type Metal Flush box 8 module complete all as specified and directed.
S&F Modular type Metal Flush box 12 module complete all as specified and directed.
S&F ceiling rose surface, polycarbonate/Bakelite, three terminals complete all as specified and directed.
S&F lamp holder with back plate suitable for batten/pendant fittings or to be mounted on walls, complete all as specified and directed
M&L for sub main wiring with two run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 Sqmm alongwith one run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 Sqmm as earth continuity conductor drawn through and including PVC conduit of suitable size, surface type incl taking down existing wiring complete all as specified and directed. (NOTE : Three runs of single core 4.0 Sqmm cable & one run of PVC conduit shall be measured as one unit)
Supply and Hanging, ceiling fan, with brushless DC motor, 1200 mm sweep without remote, down rod, canopy, fan blades and accessories, BEE 5 Star rated and connecting up including provision of PVC insulated, sheathed round flexible wire with multi stranded copper conductor of size 1.0 Sq mm, 3 core, 1100 Volts grade, from ceiling rose/ connector to fan including dismantling existing fan complete all as specified and directed. (MAKE : USHA, Model: TECHNOAIR / CROMPTON GREAVES, Model : ENERGION HS / ORIENT, Model: ECOTECH or equivalent model in BAJAJ / HAVELLS) NOTE: Old fan shall be deposited by contractor in MES store yard
S&F surface mounted LED luminaire, 1 X 20 Watt in aluminium housing, operating voltage 180-270 V, with acrylic/polycarbonate diffuser & integrated constant current electronic driver complete with all other accessories internally prewired and including connecting up with three core flexible copper wire of suitable size complete all as specified and directed. complying with the following specifications:- (a) minimum efficacy 110 lumen/watt (b) CRI not less than 80, (c) THD < 20% (c) having in built short circuit and surge protection (d) colour temperature not less than 5700 degree K (e) life not less than 25000 hours of operation
S&F in repairs LED Street Light/Bldg Security light fitting, 30 Watt, 240 Volts, in pressure die cast aluminium housing with lens and toughened glass cover with integrated constant current electronic driver, having ingress protection of IP 66 and impact resistace of IK 07 complete all as specified and directed and complying with the following specifications:-. (a) minimum efficacy 105 lumen/watt (b) CRI not less than 70, (c) THD < 10% (c) having in built short circuit and surge protection upto 4 kV (d) colour temperature not less than 5700 degree K (e) life not less than 50,000 hours of operation (f) Power factor > 0.95 (NOTES: (1) List of approved makes has been provided in particular specifications. Contractor shall ensure that luminaire provided comply with the aforesaid specifications. No claim shall be entertained during currency of work.. (2) Quoted rate is deemed to be inclusive of dismantling of existing bracket. (3) Wire for electric connection of new fitting and new GI pipe bracket shall be measured & paid separately.
Supply and Fix, Double Door, Sheet Metal Enclosure for DBs (Premium range), for mounting of MCB for 240 Volts, TPN 4 way, with 200 Amps rated copper bus bar, complete all as specified and directed. (MAKE : L&T / LEGRAND /ABB / SCHNEIDER / C&S /PANASONIC/ HAGER)
Supply and Fix, Double Door, Sheet Metal Enclosure for DBs (Premium range), for mounting of MCB for 240 Volts, SPN 8 way, with 100 Amps rated copper bus bar, complete all as specified and directed. (MAKE : L&T / LEGRAND /ABB / SCHNEIDER / C&S / PANASONIC / HAGER)
Supply and Fix, Double Door, Sheet Metal Enclosure for DBs (Premium range), for mounting of MCB for 240 Volts, SPN 4 way, with 100 Amps rated copper bus bar, complete all as specified and directed. (MAKE : L&T / LEGRAND /ABB / SCHNEIDER / C&S / PANASONIC / HAGER)
Note for Item No 161 to 163:- (1) Incoming MCB and outgoing MCBs shall be measured and paid separately as "Supply Only". (2) Quoted rate is deemed to be inclusive of blanking plate for slots remaining blank after fixing of MCBs. (3) DB & MCB shall be of the same manufacturer.
S&F MCB (premium range), 'C' series, TPN, 415 volts, 63 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / C&S / PANASONIC / HAGER)
S&F MCB (premium quality), 'C' series, SPN, 32 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / C&S / PANASONIC / HAGER)
S&F MCB (Premium Quality), 'C' series, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / C&S / PANASONIC / HAGER)
S&F exhaust fan 300 mm sweep, 900 RPM, heavy duty, AC Single Phase 230/240 volts, metal body, louvers complete with all accessories and connecting up with and including twin core twisted flexible copper conductor cable of size 1.5 sqmm (nominal area) from ceiling rose to fan complete all as spcified and directed. (MAKE : HAVELLS, Model: Turbojet SP / CROMPTON, Model: EXHD300-6-1 / USHA, Model: Turbo Heavy Duty or equivalent model in BAJAJ / ORIENT) NOTE: Old fan, if any taken down, shall be deposited by contractor in MES storeyard.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized steel earth wire 4 mm dia (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
Taking out unserviceable LT panel board/Feeder Piller box (of any size) and Supply, install, commissioning and testing of outdoor type LT panel board, cubical type, sloping canopy top roof, dust and vermin proof, made out of 3.15 mm thick CRCA sheet of size 1000 mm x 1000 mm x 500 mm, fabricated in CPRI approved factory with front and back openable door (with locking arrangement) and making compartment for each ACB/MCCB/change over switch separately, duly powder coated over a coat of red oxide zinc chrome primer inclusive of four numbers aluminium bus bar of 500 Amps capacity (of adequate length), for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper lugs and copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland),and two numbers Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with MS angle iron of size 50x50x6 mm complete with legs not more than 450mm long including grouting with PCC 1:2:4 type B1 complete all as directed by the Engr-in-Charge including supply and fixing of the following accessories :-
MCCB, 4 pole, 36 KA, thermal magnetic release, 320 Amps, Ics=100% of Icu, 415 Volts AC - 01 No (Make: L&T, Cat No: CM94103OOQ1OG / HAGER, Cat No: HMJ321DR / SCHNEIDER, Cat No: LV540318/ LEGRAND, Cat No: 6676 62/ ABB, Cat No: 1SDA116386R1 / C&S Cat No.CSE3N400ATM4P-*)
MCCB, 4 pole, 25 KA, thermal magnetic release, 125 Amps, Ics=100% of Icu, 415 Volts AC - 04 Nos (Make: L&T, Cat No: CM90642OOLO / HAGER, Cat No: HHS126DR / SCHNEIDER, Cat No: LV516312 / LEGRAND, Cat No: 6697 19 / ABB, Cat No: 1SDA116249R1 / C&S Cat No. CSE1M125ATM4P-*)
MCB, 10 kA, 'C' Curve, SPN, 63 Amps - 02 Nos
MCB, 10 kA, 'C' Curve, SP, 6 Amps - 01 Nos
LED indicating Lamp with holder for main supply & standby supply indicating RYB (Set of three) - 01 Set
CT's ratio 500/5A - 01 Set (Set of 03)
Note:-(i) All incoming and out going cables, duly thimble along with suitable size of brass cable glands, to be connected to accessories. (ii) All ACB, MCCB & Changeover to be connected internally with suitable size of aluminium strip. (iii) All requisite accessories including spreader terminals shall be provided alongwith MCCBs and cost of the same shall be deemed to be inclusive in the quoted rates.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized iron strip 25 X 4 mm (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing and dismantling of existing unsv earthing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
DILIP CONSTRUCTION
DEB AND COMPANY
M/S L.R.ENTERPRISES
SK CONSTRUCTION SYNDICATE & ENGG CO
SEN ELECTRIC WORKS
NUPUR CONSTRUCTION
KWALITY CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .