| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹33.8 L+₹2.6 L (8.28%)Rejected-Finance 1001 63 SHALIMAR GARDEN ISMAILGANJ NEAR INDIRA NAGAR SECTOR 08 CROSSING LUCKNOW 226016 | LUCKNOW | UTTAR PRADESH | 226016 | L2 | Rejected-Finance being high bid value rejected | |
| 3 | L3₹34.7 L+₹3.5 L (11.1%)Rejected-Finance 1 28 NORTH STREET SOUTH VILAYANARAYANAM NANGUNERI TALUK TIRUNELVELI DIST 627 118 | TIRUNELVELI | TIRUNELVELI | TAMIL NADU | 627118 | L3 | Rejected-Finance being high bid value rejected |
Tender Value
Refer Docs
Closing Date
21 Apr 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Tirunelveli
GE TIRUNELVELI INS KATTABOMMAN NAVAL BASE POST VIJAYANARAYANAM TIRUNELVELI
GE/TVL/8200
2022_MES_509977_2
GE/TVL/8200
Open Tender
Miscellaneous Works
Item Rate
330 days
Ramnad
As per NIT/ Tender documents
8 documents required · 8 mandatory
₹500
GE Tirunelveli
Yes
13 Jun 2022
1 Apr 2022
23 Apr 2022
1 Apr 2022
21 Apr 2022
7 Apr 2022
1 Apr 2022 - 4 Apr 2022
60 days
Amount
SCHEDULE 'A' PART-I [ A/C PLANT WORKS]
Comprehensive Maintainance of Central AC Plant by OEM/ Authorised dealer of OEM (BLUESTAR) including preventive maintainance services and attending all call breakdowns.Checking, maintaining and ensuring smooth function of the Air conditioning system equipments without any abnormalities in noise, temperature,pressures and current drawn by the motors and carrying out rectification/repair/replacement of defective parts. The key inclusion in the contract are maintaince and repair/replacement of following components in Air conditioning sysytem:- (a) Compressor (b) Refrigerant Gas (c) AHU Motors repairing/rewinding (d) AHU Belt (e) Condenser and Chiller pump repair/rewinding work (f) All the electrical components in the Bluestar control panel (g) Expansion valves and liquid line driers.
Material and labour for descaling of condensor unit 26 TR (6 Nos) by circulating dilute hydrochloric acid solution and cleaning the tubes with wire brush by removing the side cover till the tubes are thoroughly cleaned and re-circulating the fresh water after fixing the side cover with necessary gasket and bolt and nuts complete all as directed.
Supply and replacement of FRP coated forced type Cooling Tower 250 USGPM capacity suitable for 2 x 26 TR capacity central AC Plant including replacement of cold water basin, cooling tower structure, fills, drift eliminators, cooling tower fan, water distribution piping, fan deck & fan cylinder, cooling tower louvers, gear box/ drive shafts & mechanical equipment support, valves, nozzles and ensuring CT fan position for perfect balancing and proper rotation after replacement and testing for satifactory entering water temperature in the condensor unit including taking down old unserviceable unit complete all as directed. Note:- Cost of the following shall be included in the quoted rate:- (a) Founation/platform with suitable size for cooling tower at location specified as per recommendation by OEM. (b) The quoted rate shall be included for minor spares i.e pressure gauge, temperature gauge, float valve, over flow system, drain pipe & valve as per site requirement and no any extra cost shall be paid for any addl items rquired for completion of job and testing and commissioning of the complete cooling tower. (c) Loading, unloading and shifting of cooling tower. (d) Testing and commissioning of cooling tower complete as per site requirement.
Supply and lay 40mm (outer dia) 3 layers PP-R polypropylene random copolymer) pipes SDR 7.4 and SDR 11 UV stablised and antimicrobial fusion welded having thermal stability for hot and cold water supply including all PP-R plain and brass threaded polypropylene random fittings laid in trench complete all as specified and directed.
Supply and lay 32mm (outer dia) 3 layers PP-R polypropylene random copolymer) pipes SDR 7.4 and SDR 11 UV stablised and antimicrobial fusion welded having thermal stability for hot and cold water supply including all PP-R plain and brass threaded polypropylene random fittings laid in trench complete all as specified and directed.
Supply and lay 32mm (outer dia) 3 layers PP-R polypropylene random copolymer) pipes SDR 7.4 and SDR 11 UV stablised and antimicrobial welded having thermal stability for hot and cold water supply including all PP-R plain and brass threaded polypropylene random fittings fixed complete to walls, ceiling or in floors etc. complete all as specified and directed.
M&L for making connection of PP-R distributiion branch with GI main of the 25mm to 50mm bore pipes sizes by providing and fixing tee including cutting and making joint etc complete all as specified and directed.
Supply and fix 40mm ( outer dia) PP-R Gate Valves (brass insert) complete all as specified and directed.
Supply and fix 32 mm ( outer dia) PP-R Gate Valves (brass insert) complete all as specified and directed.
Material and labour for comprehensive mainatainance of Humidifier system including necessary electrical connections during the entire AMC period complete all as directed.
Material and labour for pressure gauge 4" dial, 0-21 kgs rating complete all as directed.
Supply and fix Three phase direct online starter ,suitable for 1 HP - 5 HP Pump/motor including necessary electrical connections and taking down old unserviceable complete all as directed.
Supply and fix Three phase Star delta starter , suitable for 10 HP -15 HP Pump/motor. including necessary electrical connections and taking down old unserviceable complete all as directed.
M & L for Air filter for AHU including connecting accesssories all as applicable complete all as specified and as directed by the Engineer-in-Charge
SCHEDULE 'A' PART-II [ E/M WORKS]
Excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth; for laying pipes and getting out in any type of soil, complete all as specified
Returning, filling in incl spreading leveling, watering and well ramming in layers n.exc.25cm thick complete all specified and as directed.
Removing excavated material to a distance n.exc 50 M and depositing where directed at a level n.exc 1.5 M above the starting point complete all specified and as directed.
M & L for spreading of approved riddled earth obtained from trenches for cable cushioning on top and bottom of cable as specified.for cable protection complete all as specified and directed. (Note: Only punned thickness of riddled earth shall be measured)
Supply and lay bricks in trenches , common burnt clay building bricks, subclass `B’ designation 75, old size ,with width equal to the length of the brick; complete all as specified and directed.
Cutting existing bituminous road and excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth by cutting existing bituminous road not exc 10 sq. m on plan and not exc 1.5m in depth and getting out in any type of soil, complete all as specified
Demolition of cement concrete in ground floor & paving n. exc 15 cm thick (below or above GL) unreinforced complete all as specified and directed.
M & L for 100 mm thick cement concrete 1:2:4 type B-1, using 20mm graded aggregate for making good the disturbed road surface after laying of pipe line over returned filled and compacted earth surface to match with existing road level complete all as specified and as directed.
S&F in replacement Phase indicator lamp assembly LED type (Set of three R,Y,B) complete with indicator lamp including making connections with 2.5 Sq mm copper conductor PVC insulated and PVC sheathed single core cable complete all as specified and as directed by Engineer-in-charge.
Supply and lay LT under ground cable 1100 volts grade Cross linked Polyethylene (XLPE) insulated PVC Sheathed Cables: armoured multistranded heavy duty electric cable with aluminium conductor 3.5 Core 70 Sqmm laid in trenches/ duct / walls including cable gland on both termination where necessary including laying, connecting to various switches in panel board, testing and commissioning etc including taking out existing unserviceable cables complete all as directed & as specified and as directed by Engineer-in-charge.
Description all as per item No 26 but 3.5 core 95 Sqmm size complete all specified and as directed.
Description all as per item No 26 but 3.5 core 120 Sqmm size complete all specified and as directed.
Description all as per item No 26 but 3.5 core 150 Sqmm size complete all specified and as directed.
Earthing complete with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal GL and connected to galvanized earth strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in Electrical Plate No.3 connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessry test on completion including taking down of old all as specified and as directed. Note :1. The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 20 mm dia watering pipe, wire mesh, 40mm dia medium grade GI protection pipe for earth lead etc., complete. 2. Earthing strip upto 7.5 metre length shall be deemed to be included in quoted unit rate beyond 7.5 metre, the same shall be measured and paid separately.
Supply and lay earth continuity conductor or main earting lead fixed to wall on batten or recess or burried in ground or drawn in conduit / conduit pipe or fixed to poles or any other indicted situation for loop earthing etc of galvanised steel earth strip of size 32 X 6mm including taking down old unserviceable earth strip complete for taking into credit complete all as specified and as directed by the Engineer-in-Charge
Earthing complete with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal GL and connected to galvanized earth Lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in Electrical Plate No.3 connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessry test on including taking down of old completion all as specified and as directed. Note :1. The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 20 mm dia watering pipe, wire mesh, 40mm dia medium grade GI protection pipe for earth lead etc., complete. 2. Earthing lead/G.I.Earth wire upto 7.5 metre length shall be deemed to be included in quoted unit rate beyond 7.5 metre, the same shall be measured and paid separately.
Supply and lay earth continuity conductor or main earting lead fixed to wall on batten or recess or burried in ground or drawn in conduit / conduit pipe or fixed to poles or any other indicted situation for loop earthing etc of galvanised steel earth wire 4mm dia including taking down old unserviceable GI earth wire complete all as specified and as directed.
Supply and fix in repair MCCB four pole 415 volts 50 Hz , 63 amps, with rupturing capacity 16 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed by the Engineer-in-Charge .
Supply and fix in repair MCCB four pole 415 volts 50 Hz , 100 amps, with rupturing capacity 25 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed by the Engineer-in-Charge .
Supply and fix in repair MCCB four pole 415 volts 50 Hz , 125 amps, with rupturing capacity 25 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix in repair MCCB four pole 415 volts 50 Hz , 160 Amps, with rupturing capacity 25 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix in repair MCCB four pole 415 volts 50 Hz , 200 Amps, with rupturing capacity 25 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix in repair MCCB four pole 415 volts 50 Hz , 250 Amps, with rupturing capacity 25 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed by the Engineer-in-Charge .
Servicing & overhauling of Air Circuit Breaker (ACB) of any capacity by taking out from existing LT panel, cleaning all parts internally and externally, checking of the proper tension of the springs mechanical mechanism, tightening of connection of moving, fixing contact, floating contacts, servicing of motor & charging system incl replacement of faulty parts/spares and re-fixing it on its original position and testing complete all as directed.
M & L for repair/overhauling of old LT panel board of any size/type incl cleaning with compressed air, tightening of all electric connections to bus bar & switchgears, re-fixing of door (front & backside) with proper fixing & replacement of butt hinges/ Lock with key, replacement of bus bar ,replacement of wornout lugs, nut, bolts, proper connection to main earth lead, glands to be provided/replaced as required at cable entries, fixing of door front & back side with proper locking arrangement, repair to PCC foundation as required at site and spray painting with powder coated paint with smoke grey paint in outer/inner side of panel after cleaning and preparing surface complete all as directed. Note : Aluminium Bar shall be measured and paid under respective item.
Dismantling & taking out defective LT PVC/XLPE cable from trenches including excavation and earth work, cutting and removing defective parts and supply and fixing straight through joint heat shrink kit complete including jointing material and making connection of LT cables for the following sizes :- Note :- Excavation, returning filling in removing, sand cushioning, brick etc shall be measured and paid separately under respective items of work.
(a) 3/ 3.5/ 4 core 10 to 16 sqmm
(b ) 3/ 3.5/ 4 core 25 to 50 sqmm
(c ) 3 /3.5/ 4 core 70 to 150 sqmm
(d ) 3 /3.5/ 4 core 185 sqmm
Supply and fix in repair ON Load Change over switch 415V 4 pole 200 Amps in sheet metal enclosures with cabe gland, auxillary switch and spreader links as applicable to to frame size including taking down old unserviceable ON Load Change over switch for taking into credit complete all specified and as directed.
Supply and fix in repair ON Load Change over switch 415V 4 pole 250 Amps in sheet metal enclosures with cabe gland, auxillary switch and spreader links as applicable to to frame size including taking down old unserviceable ON Load Change over switch for taking into credit complete all specified and as directed.
Supply and fix in repair ON Load Change over switch 415V 4 pole 200 Amps in open execution suitable for fixing in LT Panel with cabe gland, auxillary switch and spreader links as applicable to to frame size including taking down old unserviceable ON Load Change over switch for taking into credit complete all specified and as directed.
Supply and fix in repair ON Load Change over switch 415V 4 pole 250 Amps in open execution suitable for fixing in LT Panel with cabe gland, auxillary switch and spreader links as applicable to to frame size including taking down old unserviceable ON Load Change over switch for taking into credit complete all specified and as directed.
M&L for Writing letters (Block.Roman, Italic or Indian) with thick paint ,stand out boldly and solidly without showing signs of brush marks, if necessary, repainted until the desired result is obtained , not exc 30 cm height and painting with contrasting colour in the background of letter complete as directed. NOTE:Colour of paint shall be decided by the Engg-in-charge.
Taking down old unserviceable old damaged GI pipe and Supply and fix new GI pipe light grade of size 50mm dia for protection of UG cable on walls/under floors/road crossings/in trenches including taking down old unserviceable earthing GI pipe for taking into credit complete all as specified and as directed by the Engineer-in-Charge complete.
Taking down old unserviceable old damaged GI pipe and Supply and fix new GI pipe light grade of size 80mm dia for protection of UG cable on walls/under floors/road crossings/in trenches including taking down old unserviceable earthing GI pipe for taking into credit complete all as specified and as directed by the Engineer-in-Charge complete.
Supply and fix danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size, , complete all as specified and as directed by the Engineer-in-Charge.
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and as directed by the Engineer-in-Charge.
Laying only for LT under ground cable 1100 volts grade PVC /XLPE sheathed armoured multistranded heavy duty electric cable with aluminium conductor laid in trenches/ duct / walls including cable gland on both termination where necessary including laying, connecting to various switches in panel board, testing and commissioning etc including taking out existing unserviceable cables of following sizes complete all as directed & as specified:-
(a) 4 core 35 Sqmm
(b) 4 core 50 sqmm Note for Item No. 54 :- LT UG cable for Item No. 54.01 to 54.02 shall be issued under Schedule 'B' under free for fixing/laying only.
Supply and fix copper lugs heavy duty suitable for XLPE LT cables of following size complete all as specified and directed :-
(a) Size 25 sq.mm
(b) Size 35 sq.mm
(c) Size 50 sq.mm
(d) Size 70 sq.mm
(e) Size 95 sq.mm
(f) Size 120 sq.mm
(g) Size 150 sq.mm
(h) Size 185 sq.mm
Dismantling & taking out HT/LT burnt cable ends of any size from transformer/LT panel/LT feeder pillar box/trenches any type/size, for repair/making suitable for reconnection to cable, providing lugs to burnt end of cables, preparing fresh terminals and reconnection, fixing the removed portion of cable with transformer/in trenches/along pole/ panel/feeder pillar box, including excavation of loop & refilling complete using old bricks and sand returning filling the excavated soil complete all as specified and directed.
M & L for cable route indicator 150mm dia 3mm thick made out of cast aluminum duly marked with size and type of cable fixed on 40x40x6mm angle iron support embedded in PCC 1;2:4 type B1 using 20 mm graded (300x300x400mm size) and painted with 2 coats of anticorrosive paint over a coat of red oxide primer all as specified and as directed.
RK ENTERPRISES
sri manikandan enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .