Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.5 CrAccepted-AOC 161 VPO RAJLU GARHI GANAUR 131101 | SONIPAT | HARYANA | 131101 | ₹2.5 Cr | 1 | Accepted-AOC Work alloted |
| 2 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Others-Work Experience not attached in your Bid |
Tender Value
₹2.3 Cr
EMD Value
₹4.7 L
Closing Date
8 Aug 2024, 12:00 pmClosed
SATISH KUMAR KUMAR
Fatehabad PHED
Banmandori Const of RCC NP2 Pipe Channel Construction 2 No. Suction and Scour Wells 2 No. RCC High Level Tank 3 No RCC Filter beds 2 No Clear Water Tank Repair renovation of 2 No SS Tank Repair Raising of Boundary Wall
2024_HRY_396531_1
20248A22A064 63B3 427F 856C 751927C17A0B584PUH
Open Tender
Civil Works
Works
450 days
BANMANDORE
2 documents required · 2 mandatory
₹15,000
Yes
₹4.7 L
Yes
14 Oct 2024
2 Aug 2024
8 Aug 2024
2 Aug 2024
8 Aug 2024
2 Aug 2024
Amount
N.S. Item
Construction of 1 no. PLC based water purification plant of 0.50 MLD capacity including Const. of inlet box , inlet channel, vaccume chlorination gasses type system ,alum dozing flash mixing clri-floculator, filter box, over head reservoir for back wash including pump sets and electric control panel, waste water tank, altrasonic flow meter in inlet channel and 250 mm full bore electromeganitic flow meter in outlet pipeline including pumping sets, and electric control panel complete in all respect ( as per approved DNIT)
The Electrical HT Substation shall be provided to accommodate HT Components comprising Metering Kiosk, HT Panel, Indoor Transformers with foundation and around the platform safety fencing wire 1.52 mtr height and Power Control Centers. Exhaust Fans and Safety Equipment’s including Sand Buckets, Fire Extinguishers and Fire Alarms etc. complete as per specifications The scope of work shall cover but not restricted to the following ? Supplying, Laying, Fixing and jointing of suitable size Aluminum Conductor XLPE Cables from GO switch to Metering Panel to 11 KV VCB Panel and from there to primary of Suitable rating Step down Transformers at site ? Supplying and Installation of one suitable rating VCB Panel suitable for fault level of 350 MVA at 11 KV with necessary controls and protections. ? Supplying and Installation of 1 (1W) suitable rating 11 KV/ 433 V Step down Power Transformers, outdoor Type. ? PVC Insulated PVC Sheathed Aluminum Conductor 1.1 KV grade Armoured Cables of suitable cross section for connection between secondary of Transformer and the Incomer of Main Electrical Panel and from starter feeders in Main Panel to the respective Local Control Panels in respective Pump Houses and from their to Junction Boxes for all prime movers. ? Automatic Power Factor correction Panel with suitable relays and capacitors banks, with cable connections with the Main Electrical Panel. Necessary arrangement for firefighting will also be included in the scope of work. ? Batteries and Battery Charger,Earthling and lightening protection as per Indian Electricity Rules and Standards shall be provided. ? HT connection approved as per Indian Electricity Rules and Standards shall be provided and all expensive own cost by agency.
Supply erection, testing of light fitting including wire in the pump chamber with material upto 10 points including switch, button, plug, pvc conduit pipe and copper wire etc. as per approved specification.
Supplying erection, testing of ISI marked copper wire for motors with under ground system in PVC and flexible pipes copper wire complete in all respects with accessories like thimble etc. complete in respects. 6 SQM
Supplying erection, testing of ISI marked copper wire for motors with under ground system in PVC and flexible pipes copper wire 10 SQM complete in all respects with accessories like thimble etc. complete in respects 10 Sqm mm
Lowering of sub-soil water level upto bottom of the foundation concrete of the Structures by providing well point system on both side of the trench including cost of 100 mm dia boring. Providing and installing pipes 100 mm dia for the bore developing for a successful bore, providing and installation of pumping machinery, suction/delivery pipes, disposal of water 20 mtr away from bore point including cost of repair maintenance, running cost machinery, and diesel oil charges, consumable items, pay of the operational staff, and dismantling of the pumping machinery, and filling the bores with sand after use and reinstallation the same to the next site for repeating of the above process of well point system, if required complete construction/testing of the structures. under dry condition Nothing extra will be paid for any difficulties met with during execution/construction, This, item is only payable for after Completion of Structures and notihing shall be payable if the water table is lowered and construction work is delayed or not done due to any reason what so far.
Providing and Installing of Horizontal Centrifugal Pumping set of 500LPM with 12Mtr. Head driven with electric Motor Complete in all respect.
Operation and Maintenance for complete scope of work covered under this contract as well as existing structures of water works and existing distribution system of this water supply scheme (Banmandori), complete in all respect, as per O and M schedule for a period of 5 year after successful completion of 12 month`s defect liability period and 3 Months trial run complete in all respect as per approved NIT. The amount will be charged to the A/Mtc. estimate. Operaion and Maintenance during Defect liability period (operation only)
Operation and Maintenance during 1st year after defect liability period
Operation and Maintenance during 2nd year
Operation and Maintenance during 3rd year
Operation and Maintenance during 4th year
Operation and Maintenance during 5th year
Less Credit for old brick and brick bats taking 60% bricks (SS tank Bricks 32097 Nos + RCC Pipe channel =12564 Nos. + FB = 22515 + HLT 8435 Nos.
Less Credit for old brick and brick bats taking 40% bricks bats (SS tank 44.580 + RCC Pipe channel = 17.45 Cum, FB 31.27 and HLT 11.72 cum
Less Credit for Old material (CWT 28x20x8') Less Taking 70% bricks bats (22.636 x 70 /100 = 15.85)
Less Credit for Old material, (CWT 28x20x8') Less Taking 30% bricks (22.636 x 30 /100 x 480 = 3260)
Less Credit for Old material. RCC Pipe 250mm dia 1372 Mtr. and pannel board 2 Nos.
Less Credit Old Valve Pumping machinery credit sluice valve
Less Credit for Old material.. credit CW pump 1800 LPM x 40 Mtr H
Less credit steel scraping CWT 493.65 + 93.87 Kg
Less credit for Old Pumping Machinery and others less CW pump 1800 LPM x 45 mtr H
Less Credit of Old Material...., CWT 28x20x8' = Less Credit for CI Sluice Valve = 4 Nos.
Less Credit Old Valve.. Pipe line head work = 16 Nos. + 12 Nos.
Providing and laying D/F CI pipes for Pumping machinery
Less Credit for CI special Pipe line head work = 380 Kg + CI special 200 + 370 Kg
Less Credit of Old Steel Scrap Pump chamber 28 x 13' credit for old scrap
LESS CREDIT OF OLD MATERIAL PC 28x13 5095 No+ SST 23117 Nos.
LESS CREDIT BRICK BATS 40% PC 28x13=7.80 Cum +
less old pumping machinery of R.W. pump 800 LPM x 12 mtr head
Bidder Name
Amount
RAJKUMAR (GSTN-06BMEPK8901M1ZS) BID ID -1135595
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .