Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.6 LAccepted-AOC 329 COD COLONY KOYLA NAGAR PO KIDWAI NAGAR KANPUR 208011 | KANPUR | KANPUR | UTTAR PRADESH | 208011 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹28.6 L+₹1.3 L (4.65%)Rejected-Finance 74 103 DHANKUTTI KANPUR 208001 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208001 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹33.8 L+₹6.5 L (23.7%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹34.7 L+₹7.4 L (27.0%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN L1 |
Tender Value
Refer Docs
EMD Value
₹97,500
Closing Date
27 May 2021, 6:00 pmClosed
GE I KANPUR
GE I KANPUR Cariappa Road Kanpur cant 208004
REPAIR REPLACEMENT OF EXTERNAL WATER SUPPLY DISTRIBUTION LINE AND REPAIR TO DG SET AND OTHER MISC WORKS AT COD UNDER GE I KANPUR
2021_MES_437947_1
GE(I)/KAN/T-11 OF 2021-22
Open Tender
Civil Works - Water Works
Item Rate
270 days
Kanpur Cantt
Class D category a ii
7 documents required · 7 mandatory
₹500
GE I KANPUR
₹97,500
Yes
9 Jun 2021
23 Apr 2021
29 May 2021
23 Apr 2021
27 May 2021
10 May 2021
Amount
Excavation in trenches not exceeding 1.5 Mtr wide and n. exceeding 1.5 mtr depth in soft / loose soil and getting out for removing / laying of pipe lines complete all as specified.
Returning and filling incl spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick all as specified.
Removing of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified.
M&L for drilling hole at a depth up to 1.5 mtr below the normal ground level of suitable size to insert upto150 mm dia pipe across the road in horizontal position complete all as directed by the Engr-in-Charge.
M&L for cutting of road depth up to 1.5 mtr below the normal ground level of suitable size to lay pipe upto 150 mm dia pipe across the road in horizontal position incl making good all disturbed surfaces of road to match with existing surfaces by premix road material/PCC complete all as directed by the Engr-in-Charge.
Disconnecting,dismantling and taking up or down old/u/s/cracked GI tubing with fittings including cleaning for refixing or removal from the site of the following sizes:- Note: Excavation and earth work will be measured and paid separately under relevant items.
(a) 15mm dia
(b) 20mm dia
(c) 25mm dia
(d) 40mm dia
(e) 50mm dia
(e) 80mm dia
Refixing/relaying of old steel tubing and connections jointing and testing in new or old position incl new fittings such as required at site laid in trenches or on walls/ceiling/floors etc and making good the disturbed surface to match with existing surface as (PCC work in 1:2:4 using 20 mm graded stone aggregate/ plastering in CM 1:4 and applying finishing coat of existing treatment) complete all as specified and as directed of the following sizes :-
(a) 15 mm dia (obtained from item no 6.01)
(b) 20 mm dia (obtained from item no 6.02)
(c) 25 mm dia (obtained from item no 6.03)
(d) 40 mm dia (obtained from item no 6.04)
(e) 50 mm dia (obtained from item no 6.05)
(f) 80 mm dia (obtained from item no 6.06)
Supply & Laying, jointing and leakage testing GI tubing medium grade with all fittings such as bend, tee, elbow, union, reducer etc, laid in trenches/floor/walls and making good the disturbed surface to match with existing surface as (PCC work in 1:2:4 using 20 mm graded stone aggregate/ plastering in CM 1:4 and applying finishing coat of existing treatment) complete all as specified and as directed at site of the following sizes :- Make: Tata/Jindal/Prakash Surya as approved by GE(I). Notes :(i) The laying and jointing of pipes are required to be carried out in short / long streches catering to specific requirements of a purticular quarter or a group of blocks. (ii) Excavation & earth work shall be measured & paid seperately.
(a) 15 mm dia
(b) 20 mm dia
(c) 25 mm dia
(d) 40 mm dia
(e) 50 mm dia
(f) 80 mm dia
Disconnecting,Dismantling and Taking down of old us CI/DI/GI/Cemented Pipe pipe line incl all fittings of the following sizes:-
(a) 100 mm bore
(b ) 150 mm bore
(c) 200 mm bore
Relaying, jointing and testing old but serviceable CI/DI pipe line in new or old position incl new fittings such as required at site laid in trenches or on floors/Road/path etc and making good the disturbed surface to match with existing surface as (PCC work in 1:2:4 using 20 mm graded stone aggregate complete all as specified and as directed of the following sizes :-
(a) 100 mm bore
(b ) 150 mm bore
(c) 200 mm bore
Supply, laying, testing and commissioning Ductile Iron pipes, including Rubber gasket joints, Class K-7 in any length laid in trenches complete all as specified and directed of following sizes. Make: Electrosteel/ Jindal/Lanco/Jai balajee as approved by GE(I)
(a) 100 mm bore
(b ) 150 mm bore
(c ) 200 mm bore
S&F in replacement of cast iron double flanged sluice valve of following sizes bore class PN 1.0 confirming to IS 14846/2000 with with high tensile stainless steel spindle with CI wheel, Gun Metal Nuts/rings 'I' bolt, ISI marked including replacement of rubber packing complete all as specified and directed. Make : Kirloskar/Upadhyay as approved by GE(I).
(a) 80mm dia
(b) 100mm dia
(c) 150mm dia
(c) 200mm dia
S&F in replacement of cast iron double flanged sluice valve of 150mm dia class PN 1.6 confirming to IS 14846/2000 with high tensile stainless steel spindle with CI wheel, Gun Metal Nuts/rings 'I' bolt, ISI marked including replacement of rubber packing complete all as specified and directed. Make : Kirloskar/Upadhyay as approved by GE(I).
M & L for boring on existing CI pipe upto 200 mm dia for branch connections upto 50mm dia by fixing of MS clamp 50x4mm cut to length and bent to shape, drilled and welded with GI socket of suitable size incl rubber packing, nut, bolt etc and testing and making good all disturbed surfaces complete all as specified and direted.
Repair to GI pipe lines of size 15mm to 25 mm bore dia and repair to leaked joints of pipe line complete including replacement of old GI fitting i.e union,nipple & sockets etc including excvation and taking up & down GI pipe required cutting & threading refixing in position in trenches and making good all disturbed surfaces of wall/ floor/ road/ path to match with existing specification all as specified and as directed. Note: Excavation and earthwork shall be measured and paid separately under respective items
Repair to GI pipe lines of size 40mm to 80 mm bore bore dia and repair to leaked joints of pipe line complete including replacement of old GI fitting i.e union,nipple & sockets etc including excvation and taking up & down GI pipe required cutting & threading refixing in position in trenches and making good all disturbed surfaces of wall/ floor/ road/ path to match with existing specification all as specified and as directed. Note: Excavation and earthwork shall be measured and paid separately under respective items
Cutting existing CI/DI water main 150mm bore pipe in position for making branch connection and CI/DI pipeline (Insertion of CI/DI tees bends of different size on connection pieces or for insertion of sluice valve) including excavation & earth work. Note : Fittings such as tees, bends, collars & reducers etc incl in this item and only run lead joints, CI/DI fittings & sluice valve shall be measured and paid separately and making good all disturbed surfaces of wall/ floor/ road/ path to match with existing specification all as specified and as directed.
All as per srl No 17 but of size 100 mm bore pipe.
All as per srl No 17 but of size 80mm bore pipe.
M & L for lead joint for cast iron water mains / fittings and finishing complete with spun yarn all as directed of the following sizes :-
(a) 80 mm dia
(b) 100mm dia
(c) 150mm dia
M&L for Cast iron/ductile iron special fittings for spigot and socketed pipes such as bends (any type, radius and angle) socket tapers any type, (straight, bend, increasing, decreasing or double socket etc) Tee pieces, single branch, Y junction, double branch, cross (all sockets or socket and spigot) collers, caps and plugs for upto 150 mm bore pipes complete all as specified and directed.
S & F 20 mm dia stop valve, gun metal iron, screwed down, high pressure with crutch or butterfly handle, screwed for iron pipe or for ferrule ISI marked including dismantling the old U/S existing valve complete .
S & F in replacement of 150 mm bore non return valve both end flanged suitable for cast iron pipe including all fittings washer, nuts & bolt etc complete all as specified and directed. Make: Zoloto/Leader/Upadhyay/kirloskar as approved by GE(I).
M & L for opening up of leaking sluice valve and repacking of stuffing box & replacement of gland packing, nuts, bolts & washers etc complete all as specified of the following sizes :-
(a) 80mm dia
(b) 100mm dia
(c) 150mm dia
Supply & Fixed Gun metal Gate valve with iron wheel head conforming to IS : 778/ 1984, Class-1, Screwed both end as per IS: 554 Parallel, ISI marked including taking out the worn out/ old gate valve any typecomplete all as specified and directed suitable for following bore of pipes :- Make: Apar/Upadhyay/kirloskar as approved by GE(I).
(a) 25mm dia
(b) 40mm dia
(c ) 50mm dia
M&L joints with rubber gaskets for CI flanged pipe including necessary nut bolts and washers etc for pipe 80 mm bore all as specified.
All as per srl item 26 but of size 100mm bore.
All as per srl item 26 but of size 150mm bore.
S&F replacement stainless steel spindle with checknut suitable for sluice valve of size 80mm bore including replacment of gland packing all as directed.
All as per srl item 29 but of size 100mm bore.
All as per srl item 29 but of size 150mm bore.
Cutting and removing unwanted grass and wild growth including bushes and shrubs from the roots at water supply installations including removing and even finish the entire area complete all as specified and directed at site by Engineer in charge.
Supply only Calcium based high strenght granular chlorination chemical having 65 % to 70 % active chlorine, whitish, free flowing, decomposes clear in water solution , free of foriegn matter , the chlorination chemical should contain appropriate quantities of dispersants, corossion inhibitors to prevent incrustation scaling in distribution systems, mercury and other heavy meatl conteminents in chlorination chemical must be Below Detectable Limit (BDL) Make- PURI CHLOR of M/S Sree Rayalseema Hi-Strength Hypo Ltd or any other make as per E in C approved list. Note: Contractor shall submit Puchase voucher and test certificate from manufacturer/authorised distributor for each lot of material.
Material and Labour in repair for brick masonry valve pit chamber of size 600mm x 600mm x 950 mm (internal) complete with PCC (1:3:6) type C-2 for foundation, brick work in Cement Mortar (1:6), 15 mm thick plastering in Cement Mortar (1:4) (internally) including 6.0 mm thick MS plate covering and angle iron frame of 40mm x 40mm x 6.0 mm including coping, 100 mm thick, PCC flooring in 1:2:4 type B-1 and two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces with locking arrangement including excavation, returning filling removal of soil complete all as specified and directed.
Material and Labour in repair for brick masonry valve pit chamber of size 950mm x 950mm x 950 mm (internal) complete with PCC (1:3:6) type C-2 for foundation, brick work in Cement Mortar (1:6), 15 mm thick plastering in Cement Mortar (1:4) (internally) including 6.0 mm thick MS plate covering and angle iron frame of 40mm x 40mm x 6.0 mm including coping, 100 mm thick, PCC flooring in 1:2:4 type B-1 and two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces with locking arrangement including excavation, returning filling removal of soil complete all as specified and directed.
S & F in replacement of fully automatic star delta starter, suitable for 40/50 HP submersible motor, 3 phase 440 volt complete with over load protection with adjustable relay range, electronic timer relay and single phasing preventor incl suitable size 40X4 mm angle iron frame grouted on wall for proper mounting arrangement all as specified. Make : SEIMENS / BCH / L & T
S&F in replacement of Epoxy type cable jointing kit complete with all the jointing material, ferrule, for 1100 volts flat submersible copper conductor cable 16/10 Sqmm 3 core complete all as specified and directed. Make: M Seal/Reychem/Birla 3 M
S&F rubber gasket (packing) suitable for 80 to 150 mm flange complete all as specified and directed
Supply & Fix in replacement MS nut bolts with spring washer of any size complete all as specified and directed
Supply & Fix in replacement Steel wire rope stranded 12 mm dia for hanging of submersible pump set complete all as specified and directed
M&L for replacement of MS angle iron/channel support for motor/pump including nut bolts etc including two coat of synthetic enamel paint and making good all disturbed surfaces with PCC 1:2:4 type B-1 using 20 mm graded stone aggregate complete all as specified and directed by Engineer in charge.
S&F phase sequencer cum pump protection system 415/440 volts, 50 Hz internal working voltage 12/14 volt suitable for up to 50 HP, if incoming phase sequence is changes, single phase prevention system and adjustable low and high voltage protection system to protect the machinery, mounting on bracket made out 40x3 mm angle iron frame all control wiring cable connections as directed by Engr-in-Charge. Make : KA Switchgear or Equivalent.
Cleaning/removal of grass/bushes/plants/mud etc all around/inside the valve pit chamber up to size 1200mm x 1200mm x 950mm complete all as spd and directed all as specified and directed.
M & L for repairing micro processor based water level indicator system in between over head tank sensor to main water level indicator LED display unit showing indication at pump house by replacing the circuit board and other accessories complete all as specified and directed.
M & L for repairing leakages of CI pipes with spigot and socket ends, including de-watering of pipe lines and trenches, burning out joints to recover lead and making new lead joint with retrieved material and any additional quantity of lead required as per site requirement incl all other materials such as spun yarn, fire wood incl excavation ,earth work (upto 1.5 mtr depth) by manual /JCB machine as required at site etc and making good the disturbed surface to match with existing surface as (PCC work in 1:2:4 using 20 mm graded stone aggregate) complete all as specified and as directed for the following sizes :-
(a) 80mm dia
(b) 100mm dia
(c) 150mm dia
M& L for repairing the leakage of lead joints for CI pipe incl bailing out the line water after burning out the existing lead from joints and using extra lead and spun yarn as required and directed for pipe lines 80 mm dia bore.
All as per item no 46 above but 100 mm dia bore
All as per item no 46 above but 150 mm dia bore
All as per item no 46 above but 200 mm dia bore. Note: for item 46 to 49: Excavation and earthwork if any shall be measured and paid separately under respective items.
Taking up/down pipe line including excavation, returning filling and removal of excavated soil near existing pipe line of size 80 mm bore in break down maint of rising main line/distribution line. Providing any type of special tools & plants such as JCB & material (such as detachable joints/leak repair clamp suitable for CI/DI fittings, coller/short pieces of pipes or any other fittings as required to minimize the breakdown time and rectification of the problem as soon as possible. Rectification work must be start within two hours of intimation to contractor. Any delay in rectification may be penalized as deemed fit.
All as per item no 50 above but 100 mm dia bore
All as per item no 50 above but 150 mm dia bore
All as per item no 50 above but 200 mm dia bore. Note: for item 50 to 53: Excavation and earthwork if any shall be measured and paid separately under respective items.
M&L for repairing the leakage of flange end joints for MS/CI pipe by doing welding incl replacement of rubber gasket, nut, bolt and washers etc bailing out pipe line water as required and directed for the sizes 150mm bore.
All as per item no 54 above but 200mm bore.
Taking out defective submersible pump set and motor of capacity 20 to 40 HP from bore well with and incl taking out column pipes of any bore & length alongwith submersible cable, steel wire rope etc and relowering the pump set after carrying out necessary repairs/ replacement of defective parts complete all as specified and directed. Notes: (i) Rewinding of submersible motor will be measured & paid separately under respective item of Schedule ‘A’. (ii) Cost of all necessary T&P required at site & transportation shall deemed to be included in the unit rate quoted by the contractor.
M&L for rewinding of submersible motors 20 to 40 HP, AC, 3 phase, 440 Volts with superior quality & super enameled PVC insulated copper submersible winding wire of identical gauge and specification of the existing short circuited winding wires with all necessary insulating materials including cleaning of stator and slots and applying a coat of water proof epoxy paint to the exterior surfaces of motor and testing on load complete all as specified.
Dismantling submerisble pump straigtening and polishing of pump shaft, making threading and key way, turning surfacing polishing to impellers, CI bowl complete including replacement of worn out parts as per requirement including testing all as speciifed and directed by Engineer in charge of rating 20 to 40 HP 3 phase. Note: The cost of transportation from pumphouse/yard to workshop and workshop to pumphouse/yard shall deemed to be included in item rate quoted by Contractor. Spare p[arts shall be measured and separately under respective items.
Supply only Motor bush of Gun metal upper and lower for 20 to 40 HP capacity (Set of three)
Supply only Rotor bearing sleeves upper and lower for 20 to 40 HP capacity (Set of two)
Supply only Motor coupler sleeve with key suitable for submersible pump sets for 20 to 40 HP capacity.
Supply only Sand guard for submersible pump sets for 20 to 40 HP capacity.
Supply only thrust bearing assembly for submersible pump sets for 20 to 40 HP capacity.
S&F in replacement of electric cable for submersible pump set, flat 10 sqmm 3 core stranded copper conductor PVC sheathed cable all as specified and directed
Supply only impeller with key and distance bushes for 20 to 40 HP capacity pump complete all as specified and directed.
Supply only pump shaft of stainless steel suitable for 20 to 40 HP capacity pump complete all as specified and directed.
Supply only NRV suitable for 20 to 40 HP capacity pump complete all as specified and directed.
Supply only bearing bush suitable for 20 to 40 HP capacity pump complete all as specified and directed.
Supply only bowl assembly suitable for 20 to 40 HP capacity pump complete all as specified and directed.
Supply only distance sleeves suitable for 20 to 40 HP capacity pump complete all as specified and directed.
Disconnecting electrically dismantaling and taking out to workshop for rewinding of electric driven centrifugal motor 20 HP capacity AC, 3 phase, 440 volt with superior quality insulated copper winding wire of identical gauge and specification of the existing short circuited winding wires with all necessary insulating materials & applying one coat of water proof epoxy paint to the exteriors of motor and refixing at site including rubber coupling , cleaning of slots and testing complete all as specified and directed. Note: The cost of transportation from pumphouse/yard to workshop and workshop to pumphouse/yard shall deemed to be included in item rate quoted by Contractor.
Disconnecting electrically dismantaling and taking out to workshop for rewinding of electric driven centrifugal motor 150/175 HP capacity AC, 3 phase, 440 volt with superior quality insulated copper winding wire of identical gauge and specification of the existing short circuited winding wires with all necessary insulating materials & applying one coat of water proof epoxy paint to the exteriors of motor and refixing at site including rubber coupling , cleaning of slots and testing complete all as specified and directed. Note: The cost of transportation from pumphouse/yard to workshop and workshop to pumphouse/yard shall deemed to be included in item rate quoted by Contractor.
Disconnecting electrically dismantaling and taking out to electric driven centrifugal pump/Jockey pump and repair from workshop straightening & polishing of pump shaft making threading and key way, greasing, turning surfacing polishing to impellers, CI bowl complete including replacement of all wornout parts and coupling and refixing connecting and making alignment with motor at site as per requirement complete including testing on completion and all as directed of rating 15 KW 3 phase. Note: The cost of transportation from pumphouse/yard to workshop and workshop to pumphouse/ yard shall deemed to be included in item rate quoted by Contractor.
Disconnecting electrically dismantaling and taking out to electric driven centrifugal pump/Jockey pump and repair from workshop straightening & polishing of pump shaft making threading and key way, greasing, turning surfacing polishing to impellers, CI bowl complete including replacement of all wornout parts and coupling and refixing connecting and making alignment with motor at site as per requirement complete including testing on completion and all as directed of rating 110/130 KW 3 phase. Note: The cost of transportation from pumphouse/yard to workshop and workshop to pumphouse/ yard shall deemed to be included in item rate quoted by Contractor.
Reapir/servicing to complete DG set any make/model 75 to 380 KVA water coolent diesel engine by taking out dismantling segreagation of all parts and reassembling after duly repair/replacement of following new part fixing including all type machine work such as turning reaming etc washing cleaning greasing , wires replacement of engine oil, gaskets, flexible coupling & all type nuts bolts washers & other minor parts as required at site and testing on completion at site. Note: Any other accesories found unserviceable that shall be replaced & paid under respective items of the Schedule.
S&F in replacement of Lub oil filter element for 75 to 380 KVA DG set as per sample all as specified
S&F in replacement of Fuel filter element for 75 to 380 KVA DG set as per sample all as specified
S&F in replacement of dry type air cleaner for 75 to 380 KVA DG set as per sample all as specified
S&F in replacement of V-belt of fan for 75 to 380 KVA DG set as per sample all as specified
S&F in replacement of bye pass filter for 75 to 380 KVA DG set as per sample all as specified
S&F in replacement of starting relay for 75 to 380 KVA DG set as per sample all as specified
S&F in replacement of Electronic governer Assy for 75 to 380 KVA DG set as per sample all as specified
M&L for repalcement of complete wiring (copper multistrand cable) of DG set any capacity as directed at site including thimble screw and sleaves etc.
S&F for replacement of gauge lub oil pressure of DG set cap 75 to 380 KVA as per sample all as spfd.
S&F in replacement of hose pipe for of DG set cap 75 to 380 KVA as per sample all as spfd.
S&F in replacement of radiator hose pipe of DG set cap 75 to 380 KVA as per sample all as spfd.
S&F in replacement injector assy of DG set cap 75 to 380 KVA as per sample as spfd.
S&F in replacement of Clamp hose rediator of DG set as per sample all as spfd
S&F in replacement of water body of DG set 75 to 380 KVA as per sample all as spfd.
S&F in replcement of turbo charging kit assembly of DG set 75 to 380 KVA as per sample as spfd.
S&F replacement of self starter 12/24 volt for Dg set 75 to 380 KVA as per sample all as spfd.
S&F in replacemnt of AVR (Anti Voltage Regulator) for DG set of capacity 75 to 380 KVA KVA as per sample all as spfd.
S&F in replacement of rectifier assy comprising of 230/24/12/V step down transformer heavy duty copper wound and 24/ 12 V DC full wave rectifier unit as per sample for DG set 75 to 380 KVA as site rquirement.
Repair of PT (Pressure time) fuel pump by dismantling and segration all parts, replacement of new parts such as filter screen shut down valve, valve elbow, pulsation clamp, idle adjusting screw, high speed spring governer plug etc in replacement of existing U/S parts re-assembling the pump after repair/ replacement of parts, calibration for DG set of capacity 75 to 380 KVA & testing on completion.
Repair to rediator assy cleaning washing throughly, descaling and M&L for replacement of rubber size pad and MS Nut & bolts including brazing / repair of cooling tubes with dismantling and segregation upper and lower chamber (tank) including and reassembling complte incl nut, bolt, washer & spring any type of DG set capacity 63/75/380 KVA.
Cleaning decarbonishing complete and spray painting to complete DG set canopy outside of capacity 75 to 380 KVA icluding writing SM No Srl No Make capacity & date of installation as per sample all as directed.
Disconnecting, dismantling & repair to dynamo with segregation of all parts supply and fix in replacement of armature field, coil carbon bush and bearing etc reassembling complete & testing on completion.
M&L for replacement of coolant for DG set of make : Castrol/ Indian Oiler equivalent.
M&L for replacement of Engine oil 20 W 40 complete all as spfd make : Castrol/ Indian oiler equivalent.
Supply and fix in replacement engine Hrs run meter digital type suitable to match with existing system of DG set all as spfd.
S & F in replacement lead acid battery 12 volts 180 AH heavy duty maint free complete including initial charging complete all as specified and directed. Make: Amron/Exide/ Microtek.
Repair/ overhauling of self starter 12/24 Volts of any make/capacity including replacement of minor items such as carbon bushes, nuts, bolts, etc as per site requirement complete all as specified and directed. Note: All additional spares as required for smooth functioning of self starter will be measured and paid seprately under respective item of schedule 'A'.
S&F in microprocessor digital typr DG set controller of DG set of capacity 75 KVA to 380 KVA (Make of DG set Greaves cotton) including connect all control wiring & programming all the parameter related to DG set at site complete.
S&F in replacement of automatic battery charger AC input 230+10% V output DC for 12/24 volt battery current 10-15 Amp for 2 Nos battery at a time with digital ammeter & Voltmeter .
S&F in replacement battery terminal bolt type suitable for any type of battery
S&F for battery lead of PVC insulated copper conductor, single core 25 Sqmm, multistranded cable with suitable terminals at both ends of length as per site requirement complete all as specified and directed.
M&L for winding of armature winding and field winding with super enammeled copper wire of appropriate gauge including varnishing of insulating material and heating up , testing etc complete for DG set of capacity 75 to 380 KVA including taking down old burnt windings.
M&L for replacement flame proof asbestos rope of specified dia wrapped around the exhaust pipe complete all as spacified and directed.
M&L for top up distilled battery water for maint of batteries complete all as spacified and directed.
S&F in replacement of starting switch of DG set upto cap 63/75/380 KVA as per sample all as specified and directed
Reapir/servicing to complete DG set any make/model 62.5/125 KVA water coolent diesel engine by taking out dismantling segreagation of all parts and reassembling after duly repair/replacement of following new part fixing including all type machine work such as turning reaming etc washing cleaning greasing , wires replacement of engine oil, gaskets, flexible coupling & all type nuts bolts washers & other minor parts as required at site and testing on completion at site. Note: Any other accesories found unserviceable that shall be replaced & paid under respective items of the Schedule.
Reapir/servicing to complete DG set any make/model 15 KVA water coolent diesel engine by taking out dismantling segreagation of all parts and reassembling after duly repair/replacement of following new part fixing including all type machine work such as turning reaming etc washing cleaning greasing , wires replacement of engine oil, gaskets, flexible coupling & all type nuts bolts washers & other minor parts as required at site and testing on completion at site. Note: Any other accesories found unserviceable that shall be replaced & paid under respective items of the Schedule.
S&F in replacement of Lub oil filter element for 62.5/125 KVA DG set as per sample all as specified
S&F in replacement of Lub oil filter element for 15 KVA DG set as per sample all as specified
S&F in replacement of Fuel filter element for 62.5/125 KVA DG set as per sample all as specified
S&F in replacement of Fuel filter element for 15 KVA DG set as per sample all as specified
S&F in replacement of dry type air cleaner for 62.5/125 KVA DG set as per sample all as specified
S&F in replacement of dry type air cleaner for 15 KVA DG set as per sample all as specified
S&F in replacement of V-belt of fan for 15 to 125 KVA DG set as per sample all as specified
S&F in replacement of bye pass filter for 62.5/125 KVA DG set as per sample all as specified
S&F in replacement of bye pass filter for 15 KVA DG set as per sample all as specified
S&F in replacement of Electronic governer Assy for 62.5/125 KVA DG set as per sample all as specified
S&F in replacement of Electronic governer Assy for 15 KVA DG set as per sample all as specified
S&F in replacement of starting switch for 62.5/125 KVA DG set as per sample all as specified
S&F in replacement of starting switch for 15 KVA DG set as per sample all as specified
M&L for repalcement of complete wiring (copper multistrand cable) of DG set of capacity 15/62.5/125 KVA as directed at site including thimble screw and sleaves etc.
S&F for replacement of gauge lub oil pressure of DG set cap 15/62.5/125 KVA as per sample all as spfd.
S&F in replacement of hose pipe for of DG set cap 15/62.5/125 KVA as per sample all as spfd.
S&F in replacement of radiator hose pipe of DG set cap 15/62.5/125 KVA as per sample all as spfd.
S&F in replacement injector assy of DG set cap 62.5/125 KVA as per sample as spfd.
S&F in replacement injector assy of DG set cap 15 KVA as per sample as spfd.
S&F in replacement of Clamp hose rediator of DG set 15/62.5/125 KVA as per sample all as spfd
Supply only distance sleeves suitable for 20 to 30 HP capacity pump complete all as specified and directed.
S&F in replacement of water body of DG set 62.5/125 KVA as per sample all as spfd.
S&F in replacement of water body of DG set 15 KVA as per sample all as spfd.
S&F in replcement of turbo charging kit assembly of DG set 62.5/125 KVA as per sample as spfd.
S&F in replcement of turbo charging kit assembly of DG set 15 KVA as per sample as spfd.
S&F replacement of self starter 12/24 volt for Dg set 15/125 KVA as per sample all as spfd.
S&F in replacement of AVR (Anti Voltage Regulator) for DG set of capacity 62.5/ 125 KVA as per sample all as spfd.
S&F in replacement of AVR (Anti Voltage Regulator) for DG set of capacity 15 KVA as per sample all as spfd.
S&F in replacement of rectifier assy comprising of 230/24/12/V step down transformer heavy duty copper wound and 24/ 12 V DC full wave rectifier unit as per sample for DG set 15/62.5/125 KVA as site rquirement.
Repair of PT (Pressure time) fuel pump by dismantling and segration all parts, replacement of new parts such as filter screen shut down valve, valve elbow, pulsation clamp, idle adjusting screw, high speed spring governer plug etc in replacement of existing U/S parts re-assembling the pump after repair/ replacement of parts, calibration for DG set of capacity 15 to 125 KVA & testing on completion.
Repair to rediator assy cleaning washing throughly, descaling and M&L for replacement of rubber size pad and MS Nut & bolts including brazing / repair of cooling tubes with dismantling and segregation upper and lower chamber (tank) including and reassembling complte incl nut, bolt, washer & spring any type of DG set capacity 15 to 125 KVA.
Cleaning decarbonishing complete and spray painting to complete DG set canopy outside of capacity 15 to 125 KVA icluding writing SM No Srl No Make capacity & date of installation as per sample all as directed.
Disconnecting, dismantling & repair to dynamo with segregation of all parts supply and fix in replacement of armature field, coil carbon bush and bearing etc reassembling of capacity 15 to 125 KVA DG Set complete & testing on completion.
S&F in microprocessor digital type DG set controller of DG set of capacity 15 to 125 KVA (Make of DG set Greaves cotton) including connect all control wiring & programming all the parameter related to DG set at site complete.
Repair to battery 12 volts 180 AH in replacement of battery cells consisting of -ve plates +ve plates and separators including making terminal block of cell connections and cell cover filling of electrolyte complete all as specified and directed.
M&L for winding of armature winding and field winding with super enammeled copper wire of appropriate gauge including varnishing of insulating material and heating up , testing etc complete for DG set of capacity 15 to 125 KVA including taking down old burnt windings.
M&L for taking up and lowering of column pipe bowl assembly submersible pump set with motor with cable steel rope and connecting in existing position after stage wise extension re-development of borewell/ tube well not less more than 400mm bore by means of DTH method with suitable pressure to any depth below the ground level in any kind of rock/ soil upto 400mtr deep by air compressure up to 310 Cfm including disposal of surplus set to a distance not exc 50 mtr away to obtain sand free cear discharge or improve the yield of borewell tube well and testing complete for required yield of water by running a compressure min 36 Hrs at VRG pump house including testing of yeid by means of using necessary T&P all type of transportation i.e DTH plant, air compressure, alongwith necessary tools and plant and other equipments to the site of work and supply & pouring of Pea Gravels around the casing pipe ( if required) all as spfd and directed.
Supply only MS column pipe heavy Duty of size 150 mm nominal dia in standard length of 3.0 mtr, heavy duty duly threaded welded with MS Flange of 12 mm thick on both end with supporting ribs (4 Nos.) including jointing & with new rubber or fiber board gasket with all nuts, bolts and washer set complete all as specified and directed of Make : Jindal/TATA.
S&F in replacement of electric cable for submersible pump set, flat 16 sqmm 3 core stranded copper conductor PVC sheathed cable all as specified and directed
Supply and laying (In replacement) M S pipe ERW steel 80mm dia heavy duty including welding work and specials as per IS-3589 (1981) and thickness 4.8 mm duly painted with two coats of synthetic enamel paint over a coat of Zinc chromate primer complete all as specified and directed.
Supply and fix (In replacement) fire Hydrant landing valve type ,A, (Single head out let) of 63 mm dia of size confirming to IS 5290 complete all as specified and directed by Engineer in charge. Make : Omax or equivalent as approved by GE(I).
S & F in replacement of rubber mat 1x2 mtr 19mm thick laid down in front of LT panel/ bus bar complete ISI marked.
S & F pressure guage 4" dial 0-21 Kgs rating with cutting of pipe line and including all accessories all as spfd and directed,
M & L for RRL type hose pipe of 63mm dia and of 15meter length each, conforming to IS:636 complete with male and female coupling conforming to IS:903 complete all as specified.
M & L for painting fire hydrants hose boxes as per existing sizes complete including cleaning, scraping of old rusted surface paint inside and outside of panel surface with two coats of synthetic enamel paint and writing of SRL No as per existing size complete all as specified and directed
S & F in replecement of broken glass of fire hydrant panel with glass size 80cm x 14cm x 5mm thick end covered type including rubber beading for finish of glass as per sample all as spfd and directed.
S & F in replecement of hose box made out of 2mm thick sheet size 100cm x 45cm x 60cm with a provision two fix MS flanged pipe for hanging of hose pipe, MS line to accommodadate hose pipe, with front double window size 27cm x 90cm, with glasses size 80 x 14cm each with rubber beading with locking arrangements, painted red color and numbered with white paint and opening the valves should be outside and inside the box only hose pipe safely all as specified and directed by Engr-in-Charge. complete make Newage / ISI marked. Note: Hose box should be fitted in PCC / Brick foundation of 65cm x 50cm x 15cm size.
M & L in replacement of branch pipe gun metal 63mm instantaneous inlet, made threaded outlet, 15mm bore nozzle long all as specified.
M & L in replacement of branch pipe gun metal 63mm instantaneous inlet, made threaded outlet, 15mm bore nozzle long all as specified.
S&F of rubber gasket (packing) suitable for 80 to 150mm dia flange all as specified.
S&F in replacement of MS nut bolts with spring washers of any size all as specified.
S&F in replacement of steel wire rope stranded 12 mm dia for hanging of submersible pump set.
Disconnecting electrically, dismantling and taking down booster pump and motor at fire fighting installation COD inside and supply, installation, commissioning and testing of boaster pumping set of capacity 50 cubic meter/hr, suction and discharge 100/100 mm single stage with electric motor driven not less than 15 KW/20 HP, 3 Phase, 415 V, 50 Hz 2935 RPM, 50MWC head, of suitable capacity coupled on existing single base channel MS frame, including coupling, pump of discharge capacity 50m3/hr at 50MWC head with all accessories of make Kirloskar/KSB/Crompton complete all as specified and as directed
Disconnecting electrically, dismantling and taking down booster pump and motor and supply, fixing, testing of submersible pump set of discharge capacity 20000GPH/Hr @78 Mtr head inside the bore well comprising of bronze impellars in CI casing with stainless steel shaft, leaded bronze bearing/ bushes stainless steel shaft, sleeve complete all as per IS 8034 of 1989 complete with submersible motor AC 3 Phase, 50Hz, 380 to 440 volt, 30KW & 40 HP of current rating 58.5 with stainless steel tubing as per IS 9283 of 1974 etc all as specified and directed of KSB model No BPHA 384 type 5J or euivalntymake of Kirloskar/ Crompton.
Himanshu Construction and Suppliers
G S SANDHU & CO.
M/S PASHUPATI TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .