Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹57.3 L+₹1.1 L (1.87%)Rejected-Finance | L2 | Rejected-Finance L2 FOR REJECTED | |
| 3 | L3₹61.7 L+₹5.5 L (9.74%)Rejected-Finance | L3 | Rejected-Finance L3 FOR REJECTED | |
| 4 | L4₹61.7 L+₹5.5 L (9.80%)Rejected-Finance | L4 | Rejected-Finance L4 FOR REJECTED |
Tender Value
Refer Docs
EMD Value
₹1.1 L
Closing Date
29 Jun 2021, 6:00 pmClosed
HQ COMMANDER WORKS ENGINEER SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
A NO CWE SGNR 95 of 2020-21 SPECIAL REPAIRS TO BUILDING NO P-52 (OR MARRIED ACCOMMODATION) AT MILITARY STATION ABOHAR( 4TH CALL)
2021_MES_428155_4
CA NO. CWE SGNR - 95 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
GE ABOHAR
CLASS-C
CATEGORY-a(i)
10 documents required · 10 mandatory
₹1,000
Yes
₹1.1 L
Yes
20 Jul 2021
8 Jun 2021
1 Jul 2021
8 Jun 2021
29 Jun 2021
15 Jun 2021
Amount
Demolition of cement concrete (un-reinforced) in floors / pavings, (below or above ground level) and of any description and in any position not otherwise complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (reinforced) in roof , floors (other than ground floor ), beams, staircase, landing,chajjas and similar suspepnded work complete all as specified and directed by Engineer-in-Charge.
Demolition of mud in roofs any thickness incl plastering and leeping complete all as specified and directed by Engineer-in-Charge.
Dismantling of brick tiles or terracing tiles in roofs single layer complete all as specified and directed by Engineer-in-Charge.
M & L for 50mm thick cement concrete type C2 1:3:6 (40mm graded aggregate) as in plinth protection , surface finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Cutting holes into or through brick walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 Type B-0 as required (superficial area n. exc 150 sq cm) complete all as specified and directed by Engineer-in-Charge.
M & L mild steel TMT bars 10mm dia or over cut to length bent to shape required including cranking, hooking ends and binding with MS wire (annealed) not less than 0.90mm dia all as in column, beam etc complete all as specified and directed by Engineer-in-Charge.
All as per item Srl No 7 but for 5 mm dia and over up to and including 8 mm dia as in stirrups complete all as specified and directed by Engineer-in-Charge.
Reinforced cement concrete M-25 Design mix, type using 20mm graded stone aggregate as in as in foundations, footings, foundation beams, plinth beams; bases for columns, etc. and mass concrete complete all as specified and directed by Engineer-in-Charge.
Reinforced cement concrete M-25 Design mix, type using 20mm graded stone aggregate as in Columns, pillars, piers, posts & struts etc. all as specified and directed . (form work & reinforcement measured separately) complete all as specified and directed by Engineer-in-Charge.
Reinforced cement concrete M-25 Design mix, type using 20mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5 metre span all as specified and directed. (form work & reinforcement measured separately) complete all as specified and directed by Engineer-in-Charge.
Reinforced cement concrete M-25 Design mix, type using 20mm graded stone aggregate in slab supported on walls,beams and columns in floors,roofs,landings,balconiies,deck slabs and in shelves and the like all as specified and directed. (form work & reinforcement measured separately) complete all as specified and directed by Engineer-in-Charge.
M&L for Form work to sides of concrete fdns, footings bases of columns and plinth beams and similar works rough finished surfaces of concrete complete.
M&L for Formwork to soffits of suspended slabs, such as roof slabs, floor slabs landing and similar work not exceeding 200mm thick (Horizontal & sloping) fair finished surfaces (Note- Steel props to be use)complete all as specified and directed by Engineer-in-Charge.
M&L for From work to edges of concrete flates treads breaks in floors, window cill concrete railing, opening in convert valley floor and roof exc 5 but n.exc 10 cm wide and sides RCC/PCC band in walls complete all as specified and directed by Engineer-in-Charge.
M&L for Formwork to sides of pillars, posts, struts, piers columns & stanchions : rough finished surface of concrete :- Flat.
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed by Engineer-in-Charge.
S & F in repair stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed by Engineer-in-Charge.
Dismantling of brick work built in cement mortar complete all as specified and directed by Engineer-in-Charge.
M&L for Brick work using fly ash bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
All as above but except bricks complete all as specified and directed by Engineer-in-Charge.
M & L for brick work in half brick thick wall using fly ash bricks straight or curved on plan to any radius built in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge.
Dismantling of floor hearth or wall tiling including cement mortar bedding ( but not backing) and rubbish off the permices complete all as specified and directed by Engineer-in-Charge.
Roughening surface of old concrete floor by picking sweeping clean and washing down with water to remove dust etc complete all as specified and directed by Engineer-in-Charge.
M & L for glazed ceramic coloured tiles 7mm thick 300 x 450mm size in vertical surface set and jointed in neat cement slurry and pointed in white cement paste pigmented to the shade over 10mm thick cement sand screed (1:3) complete all as specified and directed by Engineer-in-Charge.
M & L for non skid ceramic coloured joint free tiles with matt finish, 7 to 8 mm thick ( square/ rectangular ) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in paste pigmented to tile shade over and including 15mm thick cement and sand screed (1:6) complete all as specified and directed by Engineer - in - Charge.
Ditto all as above but as in skirting over 10 mm thick rendering in CM (1:4) as in backing coat complete all as specified and directed by Engineer-in-Charge.
M & L Machine cut kota stone slab flooring 20 - 25 mm thick over cement screed base laid over and including 15mm thick screed bed in cement mortar 1:6 set and jointed with grey cement slurry mixed with pigment to match of the slab including rubbing and polishing complete all as specified and directed by Engineer-in-Charge.
M & L Machine cut kota stone slab 20 - 25 mm thick in riser of steps,skirting,dado and pillar over cement screed base laid over and including 10mm thick screed bed in cement mortar 1:4 set and jointed with grey cement slurry mixed with pigment to match of the slab including rubbing and polishing complete all as specified and directed by Engineer-in-Charge.
M&L Granite 20mm thick(of any type) works (table rubbed and polished) in step, window cills, cooking platforms and the like in cement mortar (1:4), 20 mm thick including pointing in white cement (1:2) using marble dust with admixture of pigments to match complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats or frames with shutters (with out taking off shutters from the frame) not exceeding 1.50 Sqm each all as specified .
Taking down chowkhats or frames with shutters without taking off shutters from the frame exceeding 1.5 Sqm but not exceeding 4 Sqm each and complete all as specified and directed by Engineer-in-Charge.
Taking down shutters refixing in same opening but area exceeding 1.00 Sqm and not exceeding 2.0 Sqm all as specified.
Taking down shutters but area exceeding 1.00 Sqm and not exceeding 2.0 Sqm complete all as specified and directed by Engineer-in-Charge.
S&F "fiberways" brand fiber glass reinforced plastic (FRP) Door frame of three legged of cross section 90x45 mm size single nrebate of 32mmx15mm to receive shutter of 30mm thickness. The laminate door frame moulded with two resistant grade unsatratedpolyster plain and chapped mat d or frame laminate shall be 2mm thick and shall be filled with subbish wooden block in all two three legs . the frame shall be covered with fibre glass from all side. MS stay shall be provided at the bottem to steady the frame Make- "Fiber ways, Rajshree, sintex, polycon, AS per sample MAP PHASE -II complete all as specified and directed by Engineer-in-Charge.
S&F "fiberways" brand 30mm thick glass fiber reinforced plastic (FRP) panelled door shutter of required colour are approver brand and manufacture made with fire resistance grade unsatratedpolyster plain moulded to 3mm thick fiber laminate for foming hollow ralliuded styles with wooden frame and suitable blocks of sessoned wood inside at required place for fixing of fiber-cast monolithitically with 5mm thick FRB laminated for panels and conforming to IS-4858-2000 Make- "Fiber ways, Rajshree, sintex, polycon, AS per sample MAP PHASE -II complete all as specified and directed by Engineer-in-Charge.
S & F PVC butt hinges, medium weight 100 mm size fixed with steel screw complete all as specified as directed by Engineer-in-Charge.
S & F tower bolt 150 mm of PTMT all as specified complete all as specified and directed by Engineer-in-Charge.
S & F door handle D type 150 mm of PTMT all as specified complete all as specified and directed by Engineer-in-Charge.
S & F Factory made 35mm thick IInd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; size of members of shutters as specified in SSR Part – I, Section – 8, clause 8.20 (a) ; supplied and fitted to chowkats all as specified complete all as specified and directed by Engineer-in-Charge.
S & F Factory made Plain framed, panelled shutter IInd class hardwood rail and style 35 mm thickness (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed by Engineer-in-Charge.
S & F pressed steel door frames with one or more rebates including necessary fixing lugs hinges lock strike plate etc size of frame 105X60mm complete all as specified and directed by Engineer-in-Charge.
S & F pressed steel door frames size of 125X60mm with one or more rebates including necessary fixing lugs hinges lock strike plate etc complete all as specified and directed by Engineer-in-Charge.
M&L Cement concrete 1:3:6 type C-1 for filling of pressed steel fram and hold fast blocks etc complete all as specified and directed by Engineer-in-Charge.
S & F mild steel tower bolts, stove enamelled black, with bright bolt and fixed, length of bolt 200mm long complete all as specified and directed by Engineer-in-Charge.
S & F aluminium bow handle 150 mm long complete all as specified and directed by Engineer-in-Charge.
S & F mild steel sliding door, bolts, plate type, stove enamelled black with bright bolt not less than 12mm bore, length of bolt 250mm complete all as specified and directed by Engineer-in-Charge.
S & F mild steel 300mm ordinary rat rail rod pattern spring inluding roller and roller plate complete all as specified .
S & F small fittings such as door stops and like, including all necessary labours articles not exceeding 200 Cucm each of 2nd class hard wood complete all as specified and directed by Engineer-in-Charge.
S&F hasp & staple safety type mild steel with hinges pins incl bolt to hinge plate fixed with screw 125mm complete all as specified and directed by Engineer-in-Charge.
S&F peg set of stainless steel solid body of 125mm to 175 mm having 6 Nos hooks fixed with brass chromium plated screws complete in complete all as specified and directed by Engineer-in-Charge.
S& F in repairs curtain rod of aluminium alloy of 25 mm dia with fixing brackets,stops,rollers etc. all as specified and complete all as specified and directed by Engineer-in-Charge.
M & L providing two coats of synthetic enamel paint over new surface and a coat of red oxide primer on steel surfaces including preparation of surface of any description not exceeding 10 cm width or girth complete all as specified and directed by Engineer-in-Charge.
Dismantling wrought iron or mild steel work of any description complete all as specified and directed by Engineer-in-Charge.
S & F structural steel work rolled mild steel joist, channel,angle,or Tee sections, fixed independently conforming to Fe 410-W complete all as specified and directed by Engineer-in-Charge.
S & F exc 12 mm dia & n. exc 20 mm dia of neck mild steel bolts purpose made with hesagonal or square head one and end and screwed to other, or screwed to both ends each screwed end to be fitted with washers and one hexagonal or square nut exc 30 cm long complete all as specified and directed by Engineer-in-Charge.
M&L plates (plain or chequered) channels , square cut or notched (ordinary and counter sunk) forming holes , without any attachment Fe-415 -W (Gde -e -250) quality -B complete all as specified complete all as specified and directed by Engineer-in-Charge.
S & F framed work such as grills, cooler stand ,grating, etc., with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work or water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed by Engineer-in-Charge.
S&F sink with drainage bord made of Stainless Steel 1mm thick kitchen with plug washer and waste including bedding in cement mortar to dwarf wall including fixing contilever brackets connecting union to pipe over all size 915x460 mm bowl of size 410 x 330 x 160 mm fixed in repair complete all as specified and directed by Engineer-in-Charge.
Dismantaling boarding, any discription fixed in any position with nails complete all as specified and directed by Engineer-in-Charge.
M & L for prelaminated particle board exterior grade 19mm in repair kichen cabinate as specified by Engr-in-charge
S & F tower bolt 100 mm of PTMT all as specified complete all as specified and directed by Engineer-in-Charge.
S & F door handl D type 100 mm of PTMT complete all as specified and directed by Engineer-in-Charge.
S & F Continuous (piano) hinges, mild steel, bright finish or electrogalvanised all as specified.
S&F 'Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed complete all as specified and directed by Engineer-in-Charge.
M&L for water proofing treatment for RCC sunken slab(not exceeding 45cm depth of sunken) as specified below and as directed by Eng in charge.- (a) 15mm plaster in cm 1:3 with WPC on raised vertical surface (b) cleaning the surface with wire bruse/coir brush, removing lose material like dust particals, dirt etc. (c) Creating fillet covering of 50x50 mm with polymer modified mortar on the junction of slab and walls (d) Apply frist coat of two component modified polymer coating on the horizontal and vertical surface (e) provision of glass fiber mesh of 2x2 mm immediately on above coating (f) Apply second coat of two component modified polymer coating after 72 hrs (g) laying concrete 1:4:8 over the coating as per requirement (h) joining the sanitery pipes with the waterproofing tape having bridging ability of more then 1.5mm (j) filling the gap between the wall opening and sanitery pipe with non shrink cementatious grout (k) Complete the treatment to be carried out by authorised applicatir of waterproofing manufacturer. Make:- Dr. Fixit/ Fosroc/BASF/STP . Note: (i) the treatment shall be carried out as per the manufacturer instruction complete all as specified and directed by Engineer-in-Charge. (ii) The plan area of floor shall be considerd for payment. (iii) Cost of WPC @ 3% by wt of cement is included in the unit rate of item.
Providing 100mm cement concrete Type E-2, 1:5:10 (40 mm graded stone aggregate as in foundation, filling and mass concrete) complete all as specified and directed by Engineer-in-Charge.
S&F Stainless steel plate rack of size 750mm x 600mm, made out of 1mm thick stainless steel of sheet of 1st quality complete all as specified and directed by Engineer -in -charge.
S & F repair vitreous china squatting pan Orrisa pattern size 580mm x 440mm white with integral foot rest with CI ‘P’ or ‘S’ trap and fixing in lime concrete (1 lime, 2 sand and 5 aggregate), 150mm thick all round and finished just below level of rim of pan to receive the floor finishing complete all as specified and directed by Engineer-in-Charge.
S & F in repairs PVC 10 ltrs syphonic action type flushing cistern, low level with inlet, ball valve, float and handle including brackets, flush pipe of PVC 32mm bore and connection to WC pan complete all as specified .
S & F in repairs vitrous china oval wash hand basin white of size 550X400 mm including brackets 300mm long PVC connection with brass nuts, 40mm dia waste coupling including cutting for and pinning in end of brackets or erecting stand etc coloured top bowl type screwed shank fly nut flange end including cutting for and pinning in granite slab of hole including 32 mm dia chromium plated waste coupling and bottle trap all as specified .(MAKE- Hindwareor equivalent in Parryware) complete all as specified and directed by Engineer-in-Charge.
S&F in repair 15mm bore bib taps,chromium plated, fancy type, cast copper alloy with crutch or butterfly handle , screwed down, secrewed for iron pipe or for brass ferrule complete all as specified and directed by Engr-in- charge.
S & F in repairs 15mm bore stop cock one way chromium plated, high pressure, with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed complete all as specified and directed by Engineer-in-Charge.
S&F in repair brass chromium plated central hole basin mixer with regular spout,popup waste system and 450mm long braided hoses with connection and nuts complete all as specified and directed by Engr-in-charge.Make Ess cat part No-C- 211A complete all as specified and directed by Engineer-in-Charge.
S & F in repairs 15mm bore stop valve, cast copper alloy fancy type chromium plated with long shank and cup ( concealed type ) screwed down, high pressure, with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed complete all as specified and directed by Engineer-in-Charge.
S&F Sink mixer with swinging spout(wall mounted model)Chromium plated brass with connection and nut complete all as specified and directed by Engr-in-charge.
S&F brass chromium plated wall mixer for mixing hot& cold water screwed down for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.
S & F in repair PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed by Engineer-in-Charge.
S&F PVC bathroom cabinet mirror 450 x 350 mm complete all as specified and directed by Engr-in-charge.
S&F Swivel shower of PTMT any colour with shower arm 15 mm size 195 mm long with bend of 45 degree with flange of any colour for fixing with 15mm pipe. (Minimum weight 40gms)complete all as specified and directed by Engineer-in-Charge.
S&F Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) complete all as specified and directed by Engineer-in-Charge.
S & F in repair soap dish vitreous china white approximately size 160 x160x 90 mm and fixed with as chromium plated brass screws complete all as specified and directed by Engineer -in -charge.
S&F in repair Brass chromium plated Tubular towel rail 20mm dia, D type, 60cm long between flanges complete all as specified and directed by Engineer-in-Charge.
S&F for PVC corner shelf with bracket complete all as specified and directed by Engr-in- charge.
Taking down steel tubing 15mm bore and connections complete all as specified and directed by Engineer-in-Charge.
Fixing only tubes any grade 15mm bore to walls and ceiling or in floors etc including provision of new fittings as required (Serviceable galvanised tubes retrieved from respective items shall be laid under these items) complete all as specified and directed by Engineer-in-Charge..
S & F 15mm bore medium grade tube galvanised with all fittings and fixed complete concealed including groove cutting for concealing to walls & ceiling or laid in floor complete all as specified and directed by Engineer-in-Charge.
Taking down steel tubing 20mm bore and connections complete all as specified and directed by Engineer-in-Charge.
Fixing only tubes any grade 20mm bore to walls and ceiling or in floors etc including provision of new fittings as required (Serviceable galvanised tubes retrieved from respective items shall be laid under these items) complete all as specified and directed by Engineer-in-Charge.
S & F 20mm bore medium grade tube galvanised with all fittings and fixed complete concealed including groove cutting for concealing to walls & ceiling or laid in floor complete all as specified and directed by Engineer-in-Charge.
Dismantling water tanks of 500 ltrs and removing to store complete all as specified and directed by Engineer-in-Charge.
S & F rotational moulded polythene three layered white coloured water storage tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I of capacity 500 Litres all as specified and directed by Engineer - in - Charge .
M&L Ball brass valves 20mm, high pressure, with polythene float and fly nut complete, screwed for iron pipe complete all as specified and directed by Engineer-in-Charge.
S & F in 15mm bore gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.
S & F in 20mm bore gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed all as specified .
Taking down CI/AC/PVC soil waste and vent pipe any radius including all fittings complete all as specified and directed by Engineer-in-Charge.
S & F in repairs PVC socketed SWR pipe with rubber ring joints 110mm dia fixed to wall complete all as specified and directed by Engineer-in-Charge.
S & F in repairs PVC socketed SWR pipe with rubber ring joints 75mm dia fixed to wall complete all as specified and directed by Engineer-in-Charge.
S&F cast iron waste and vent pipe in any length with or without ear with cement joints laid in trenches or in floor 100mm dia complete all as specified and directed by Engineer-in-Charge.
All as per ser item No 103 but for 75mm bore complete all as specified and directed by Engineer-in-Charge.
S&F for 110mm bore PVC (SWR) bends any radious provided with access door complete all as specified and directed by Engineer-in-Charge.
S&F for 75mm bore PVC (SWR) bends any radious provided with access door complete all as specified and directed by Engineer-in-Charge.
S&F for 75 mm bore PVC (SWR) multi floor trap with grating including jointing with solvent cement complete all as specified and directed by Engineer-in-Charge.
S & F Grating doom 125 mm dia with waste hole of PTMT ( Min wt 40 gm )
Taking down cement plaster/dado on brick wall including racking out joints, hacking for keys scrubbing down with water complete all as specified and directed by Engineer-in-Charge.
M & L rendering 15mm thick on fair faces or other than fair faces of brick work in CM 1:6 finished even & smooth without using extra cement all as specified .
M & L rendering 15mm thick on fair faces of brick work in CM 1:4 finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Providing & applying Rising damp proof coating system with single component ready to use damp-proof coating Roff Hydamp: 1.SURFACE PREPARATION:Thoroughly brush and clean all laitance,loose particles such as dirt,grease,mortar droppings,release agents,efflorescence,bird droppings etc. all large voids or hollow portions must be removed and replastered.Non-moving cracks having width upto 5 mm must be filled with polymer based crack filler complete all as specified and directed by Engineer-in-Charge. 2.APPLICATION: Apply the first coat of Hydamp with paintbrush directly on the prepared surfaces.Allow to dry for a minimum 2-3 hrs.Apply one part of Roff Hydamp and 2 parts of OPC white cement and make the putty,apply putty on the entire surface area.Allow it to dry for atleast 3-4 hours.Apply the final coat of Roff Hydamp on the entire surface complete all as specified and directed by Engineer-in-Charge.
M&L three coat of white wash on ceiling including necessary preparation complete all as specified and directed by Engineer-in-Charge.
M&L three coat of white wash on wall including necessary preparation complete all as specified and directed by Engineer-in-Charge.
M&L for prepartion of newly plastered wall surfaces and applying two coat of oil bound distemper over 3 mm thick wall care putty over one coat clearcolle primer including all as specified and directed by Engr-in-charge.
M&L for Complete removal of old plastered wall surfaces and applying two coat of oil bound distemper over 3 mm thick wall care putty over one coat clearcolle primer including all as specified and directed by Engr-in-charge.
M&L for preparation of two coat of cement base paint over a coat of alkali resistant prilmer on newly plastered complete all as specified and directed by Engr-in-charge.
M&L for Complete removal of old plastered wall surfaces and applying two coat of cement base paint over a coat of alkali resistant prilmer complete all as specified and directed by Engr-in-charge.
M&L for preperation of old wooden surface and applying one coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer-in-Charge.
M & L providing two coats of synthetic enamel paint over new wooden surface including preparation of surface with primer complete all as specified and directed by Engineer-in-Charge.
M & L providing two coats of synthetic enamel paint over new surface and a coat of red oxide primer on steel surfaces including preparation of surface of any description not exceeding 10 cm width or girth complete all as specified and directed by Engineer-in-Charge.
S&F in repair powder coated aluminium sliding window three track with frame & two glass shutters using 4 mm thick glass tinted modi guard and ond shutter with stainless steel wire gauge wire cloth 0.31 mm nominal dia of wire and width of aperture 1.61mm using aluminium powder coated section aluminium cleat, PVC track, bearing, handle lock rubber beading etc complete fittings as approved. Note :- Size of aluminum section shall be under – (i) Three track top and vertical –jindal main-2010 section No 20621 or equivalent as approved by GE. (ii) Three track bottom-Jindal main-2010 section No 20620 or equivalent as approved by GE. (iii) Shutter vertical section-Jindal main-2010 section 20604 or equivalent as approved by GE. (iv) Shutter top and bottom –Jindal main – 2010 section 20604 or equivalent as approved by GE. (v) Shutter vertical middle (interlock) – Jindal main – 2010 section 20605 or equivalent as approved by GE.
S&F for powder quoted Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified.
S&F powder quoted aluminum window and ventilator shutter side hung type without sash, aluminium sections weighing glazing clips, rubber packing anodised aluminium snap beading screws, anodised aluminium fittings such as peg stays 150 mm long (1 no) hinges type B-21 100 mm long (2 no) suitable handle (1 no) complete all as specified as directed by Engineer-in-Charge.
S&F aluminum anodised grill diamond shape 100mm x100mm aperture of 6mm dia round bars including necessary joining cleats, clips anodised aluminium snap beading screws complete all as specified as directed by Engineer-in-Charge.
M & L Washed stone grit plaster on exterior walls in two layers under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per sqm, top layer 15 mm cement plaster 1:1/2:2 (1 cement : ½ coarse sand : 2 stone chipping 10 mm normal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to be expose the stone chippings complete all as specified (Payment for providing grooves shall be made separately).
Forming groove of uniform size 15 mm wide and 15 mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden batterns, nailed to the under layer including removal of wooden batterns, repair to the edges of panels and finishing the groove complete as per specification and direction of the Engineer-in-Charge
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc, laid bedded and pointed in any mortar complete all as specified and directed by Engineer-in-Charge.
Hard core of broken bricks of gauge not exceeding 63mm, deposited,spread and leveled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge.
M&L PCC 75 mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate)as in sub base complete all as specified and directed by Engineer-in-Charge.
M&L for Machine pressed precast concrete coloured interlocking paver block any shape and size conforming to IS 15658-2006 of 80 mm thickness M-40 Grade over 25 mm thick layer of fine sand complete all as specified and directed by Engineer-in-Charge.
M&L for contineous brick edging with burnt clay brick work with sub class ‘B’ with width equal to width of brick laid dry on end vertically complete all as specified and directed by Engineer-in-Charge.
S&F Floor door stopper of aluminum allow body and tongue, 150mm overall length, anodised, with hard drawn steel spring, fixed in floorcomplete all as specified and directed by Engineer-in-Charge.
Excavation trenches n exc 1.50 wide and n exc 1.50 m depth for foundation etc in any type of soil complete all as specified and directed by Engineer-in-Charge.
Returning filling in including spreading leveling, watering and well ramming in layers n exc 25 mm thick soil.
Removing excavated material n exc 250 m and deposited where directed at a level not exc 1.50 m above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L Providing cement concrete Type D-2, 1:4:8 (40 mm graded stone aggregate as in foundation, filling and mass concrete) complete all as specified and directed by Engineer-in-Charge.
S&F cast iron bend ( any radius) dimenshing pieces or tappers ( large bore measured) 100mm bore complete all as specified and directed by Engineer-in-Charge.
All as per item ser No 133 but for 75 mm bore complete all as specified and directed by Engineer-in-Charge.
S&F cast iron floor trap 75mm dia incl jointing to waste pipe fixed in cement concrete type B-1 1:2:4) 75mm dia fixed in repaircomplete all as specified and directed by Engineer-in-Charge.
S & F steel work in rectanguler/square trusses incl special shaped washer etc complete using ERW or incl butt welded tubes confirming to relevant IS code with one coat of zink chrome primer incl preparation of surface complete all as specified and directed by Engineer-in-Charge.
S&F 50mm thick PUF panel made of Puf insulation in core having density 40+2 Kg/Cum sandwiched betweeen two numbers of polyster coated galvalume steel sheet.these sheets shall be made out of 0.50mm thick (TCT) High tensile steel having min yield strength of 550 Mpa confirm to AZ 150 of AS-1397 wityh hot dip metalic coating of 55% ZN alloy having total coating mass of minimum 150 gms/sqm inclusive of bothside. the material shall be coated with polyster coating paint system of 20 micron over primer of 5 micron (exposed side) & alkyd back coat of 5 micron over primer coat of 5 microns.the material shall be supplied as per drawing (approved by GE),colour and as per instruction complete all as specified and directed by Engineer-in-charge.
S&F Anodised aluminium snap grid frame work for false ceiling Size of Grid 605 x605 mm with 6mm dia GI wire hanger ( upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size 60 mm long Complete all as specified and directed by Engr-in -Charge.
S&F, 8 mm thick exposed metal frame celing with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600mmx600mm grid all as per manufacturer's instructions. finish, fixed to aluminium/ CGI frame work with hold down clips in false ceiling complete all as specified and directed by Engineer-in-Charge.
M& L for Pre painted gavalume zinc coating GI based plain steel sheet 0.50mm thick for ridge ,hip,vally gutter ,drips of an colour having tensile strength of 550 Mpa as in wall,fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
M& L for Pre painted gavalume zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof coverings/cladding to wall,fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
Shotcreting 25MM thick in RCC columns, beams and slabs etc in layers with approved design mix (minimum cement content of 350 Kg/Cum on M-25) concrete having the specified minimum characterristic compressive strength (with ordinary protland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria) including the cost of certering and shuttering at edges and corners etc as directed by Engineer-in-Charge including Chipping of unsound /weak concrete material 25 mm average thickness from slabs,beams, columns etc with manual chisel and /or by standred power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes and thoroughly washing with water and allowing it to dry etc. including removal of rust by applying approved rust removal chemical & the coating with Dr Fixit epoxy zinc primer@ 6sqm/ltr at DFT of 100microns as per specifications and disposal of debries for all lead and lifts all complete as per direction of Engineer-in-Charge.
S&F Hard drawn steel wire fabric not exc 4Kg/Sqm cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcemnt all as specified & directed by Engineer-in-Charge.
M & L 5mm thick rendering in Cement Mortar 1:3 on fair faces of brick work or concrete surfaces of ceiling finished even and smooth without using extra cement complete all as specified and directed by Engineer - in - Charge .
M& L PCC 1:2:4 type B1, using 20 mm graded agg.as in bed blocks ,coping, hold fast blocks etc.
Excavation in trenches , n exc 1.5m wide and n exc 1.5m in depth , for foundation , etc or for shaft, well, cesspits , manholes , pier hole etc n exc 1.5 m in depth and getting out complete all as specified and directed by Engineer-in-Charge.
Returning , filling in including, spreading , levelling , watering and well reamming in layers not exc complete all as specified and directed by Engineer-in-Charge.
Removing excavated material n exc 50m and depositing where as directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
Sand filling under flooors or in foundation including and consolidation as as specified and directed at site complete all as specified and directed by Engineer-in-Charge.
M & L brick sub class 'B' locally available best quality laid in trenches above sand consolidted forcable protection complete all as specified and directed by Engineer-in-Charge.
Supplying, laying, jointing and testing XLPE PVC insulated heavy duty multi stranded armoured and PVC sheathed LT cable 1100 volts grade with aluminium conductor cross sectional area 25 sqmm 4 core conforming to IS- 1554 laid in trenches/ ducts/ along poles/ through pipes including provision of cable glands to both ends of connection point complete all as specified & directed by Engineer-in- charge. Note: Excavation & earth work shall be measured & paid separately under appropriate item of this Schedule complete all as specified and directed by Engineer-in-Charge.
Taking down carefully copper /aluminium point wiring (light ,fan ,socket or power) complete incl fixture and fitting such as Switches, ceiling roses, pandents, regulators,sockets, light fitting etc removing materials to store for keeping in safe custody for taking credit(credit for above items shuold be made as per conditions separately) and making good distrubed surface of wall ,floors etc.complete all as specified and directed by Engineer-in-Charge.
M & L point wiring with PVC FRLS insulated (Concealed) unsheathed multistranded copper conductor drawn in and incl of size 1.5 Sqmm, 1100V grade in concealed PVC regid conduit, including provn of of 1.2 mm thich pressed steel sunken terminal boxes 60mm deep,suitable lenthand painted with red oxide primer for mounting switches, sockets, fan regulators covered with and including 3mm thick bakelite plastic laminated sheet top cover fixed flush with wall using brass screws & cup washers including 1.5Sqmm PVC insulated stranded copper conductor as earth continuity wire and connected to common earth dolly with copper lugs inserted in including MS boards complete heavy duty for housing switches, sockets, regulators, bell push etc, complete all as directed for the One light/Bell/fan point controlled by one way switch 5 Amp complete all as specified and directed by Engineer-in-Charge.
M&L One light/Bell/fan point controlled by one two way switch 5 Amp complete all as specified and directed by Engineer-in-Charge.
M&Lone 3 pin socket outlet, 5 Amps on the same board with other switches, with cables 1.5 sq mm size complete.
M&L one 3 pin socket outlet, 5 Amps on independent board with other switches, with cables 1.5 sq mm size complete all as specified and directed by Engineer-in-Charge.
All per item srl no 155 here before but for with cable of 2.5 sq mm for 15 amps Socket Independent board with other switches complete all as specified and directed by Engineer-in-Charge.
All as per item Set No155 here in before but for 15 amps socket outlet with 4 Sqmm Copper incl 4.0 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed by Engineer-in-Charge.
M & L point wiring with PVC FRLS insulated unsheathed multistranded copper conductor of size 1.5 Sqmm, 1100V grade in Existing concealed conduit, and one run PVC FRLS insulated unsheathed copper conductor of size 1.5 Sqmm as earth continuity wire and connected to common earth dolly with copper including provn of of 1.2 mm thick pressed steel sunken terminal boxes 60mm deep suitable lenth and painted with red oxide primer in place of unserviceable shunken box complete for housing switches, , regulators, bell push etc, complete all as directed for the One light / fan point controlled by one way piano switch 5 Amp complete all as specified and directed by Engineer-in-Charge.
S & F One socket point 5 Amp on an independent board. complete all as specified and directed by Engineer-in-Charge.
S & F One socket point 5 Amp on same board complete all as specified and directed by Engineer-in-Charge.
S & F point wiring controlled by two, two way switch complete all as specified and directed by Engineer-in-Charge.
S & F Ditto but with cable of 2.5 sq mm for 15 amps Socket Independent board with other switches complete all as specified and directed by Engineer-in-Charge.
S & F switch piano ,flush type single pole, one way 5 amp, 2way 5 Amp,/bell push complete all as specified and directed by Engineer-in-Charge.
S & F switch piano ,flush type single pole, one way 6/15 Amps 5 pin complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of socket outlet 2 in 1, 3 pin 5 Amps complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of socket outlet 2 in 1, 3 pin 5 Amps and 15 Amps complete all as specified and directed by Engineer-in-Charge.
M & L for celling rose 3 pin/pvc/ polycarbonate isolated body complete all as specified and complete all as specified and directed by Engineer-in-Charge.
M&L for LED tube light fitting of LED T5 tube lights (6500K) environomental freiendly energy efficient of 18/20 Watt LED including electric connection with PVC copper flexible twin core cable, 1.0 sqmm from ceiling rose to light fitting complete all as specified and directed by Engr-In-charge. Make:Syska SSK-SQ2001 20W or equvalent of Havells/Crompton Greaves/ Philips/Wipro/Polycab as recommended by Engr-Incharge and approved by GE.
Supply and fix in replacement of stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as reqd complete all as specified and directed by Engineer-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to galvanised iron of 4 sqmm SWG earht wire fixed by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 40mm dia upto 3m height above ground level and water pipe 20mm dia GI medium grade with socket and plug 30 cm above ground level including earthwork, PCC chamber in PCC (1:3:6) type C-2 using 40mm stone aggregate, cast iron cover, wire meah etc all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete and all as specified and direcrted by Engr-in-charge Notes :- (i) 20 mm dia GI pipe for watering to be provided with a socket and plug and should be 30 cms above ground level. (ii) GI strip upto DBs earth connection is included in this item. (iii) GI pipe 40 mm dia protection pipe shall be provided upto Ground level complete all as specified and directed by Engineer-in-Charge.
S & F in sheet metal enclosures for DBs double door type when MCBs to be used single pole & nuteral 8 ways s all as specified and directed by Engg-in-Charge.
S&F MCB SPN 63 Amps, 240 Volts complete all as specified and directed by Engineer-in-Charge.
S&F MCB SP 6 to 40 Amps, 240 Volts complete all as specified and directed by Engineer-in-Charge.
M&L for submain wiring comprising single core ,2 Runs of 10 sqmm nominal cross sectional area multimultistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. PVC conduits and conduit fittings not less than 25 mm dia complete, including provision of 1 x 10 sqmm nominal cross sectional area multimultistranded copper conductor cable PVC insulated unsheathed 1100 Volts grade as earth wire and using color code as per IS and specified and making good all disturbed work to match the existing complete incl taking down old UNSV sub main complete all as specified and directed by Engineer-in-Charge. ( Note :- Extra length of cables/ wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly)
Description all as per item No 30 here in before but ,2 Runs of 6 sqmm nominal cross section and including provision of 1 x 6 sqmm nominal cross sectional area for earth wire complete all as specified and directed by Engineer-in-Charge.
Description all as per item No 30 here in before but ,2 Runs of 4 sqmm nominal cross section and including provision of 1X4.0 sqmm nominal cross sectional area for earth wire complete all as specified and directed by Engineer-in-Charge.
M & L cutting chases, pinning in, making god to facings where reuired and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc ; and cutting chases for concealed water tubing or concealed wiring etc, and making good, cutting not exc 10 cm girth in brick walls complete all as specified and directed by Engineer-in-Charge.
S & F LED street light luminaitres 20/25 watts with IP66 complete with pressure dia cast aluminium housing with GI pipe bracket made out of 25 mm dia medium grade pipe (60 cm long) bend to shape including fixing arrangement to wall with MS flat 25x3mm-2 Nos by nut, bolts and washers including electric connection with PVC copper flexible twin core cable 1.0 sqmm from ceiling rose to light fitting complete all as specified and directed by Engr-In-charge. Make:Syska max glow series SSK-ST25W-MG or equvalent of Havells/Crompton Greaves/ Philips/Wipro/Polycab as recommended by Engr-Incharge and approved by GE.
Supply and fix LT Main control board of CRCA sheet metal board made out of 2.0mm thick and painting with 2 coats with synthetic enemel paint over a coat of red oxide primer including copper bus bar and fixed on/inside wall for fixing arrangement of existing electronic meter incl internal connection with suitable size of copper conductor wire, and accessories, locking arrangement with opening handle (size not less than of box 100cmx80cmx25cm and adequate depth for the following equipments,internal wiring and termination of external cables, lugs and glands and conduit as required) including Taking down existing Old Unserviceable main control board comprising of following complete all as specified and directed by Engineer-in-Charge.:- (a) Incoming :- MCCB 100 Amps, 4 Pole,415 Amps, 25 KA-01 No (b) copper Bus bar 200 Amps for phase and neutral and earth bar , (c) Out going MCB SPN 63 Amps - 4 Nos (d) Taking down Electric meter from existing distribution board and Re-fixing only existing electronic meter single phase 15 to 40 Amps, 240 Volts on new distribution panel- 04 Nos
S & F GI tube light grade galvanised of size 50 mm with all fitting and fixed to wall and celling or laid in floors for cable protection complete all as specdied and directed by Engineer-in- Charge.
S&F call bell ding-dong type, AC 230 Volts single pole complete all as specified and directed by Engineer-in-Charge.
Taking down/ dismantling complete ceiling fan of size 1200/1400 mm sweep down rod with its canopies, shackle, condenser housing with its rubber bushes, split pins, unscrewing the body parts of ceiling fan, taking out starter, rotor winding ball bearing, gun metal bush etc. complete to carry out the following repairs :- (a) Removing of burnt out fan winding and re-winding of motor with suitable size of copper enamelled wire, varnishing, heating as per manufactures design and directed and re-assembling complete ceiling fan fixing only old/new spare parts (i.e.) rubber bush of shackle and condenser housing, condenser, gun metal bushes, ball bearing, twin twisted copper cable, etc complete all as specified and directed by Engineer-in-charge. (Note :- Ball bearing and Gun metal bush are measured and paid separately as supply only rates and fixing charges for spare parts shall deemed to be included in Schedule 'A' of Item No 31 & 32).
S&F for Condenser 2/2.5 MFD. (Make : Universal (metal body) complete all as specified and directed by Engineer-in-Charge.
S&F for Condenser 3.15/4 MFD. (Make : Universal (metal body) complete all as specified and directed by Engineer-in-Charge.
S&F for rubber bush for shackle with bolt, nut and lock pin suitable for ceiling fan 1200mm/1400mm sweep complete all as specified and directed by Engineer-in-Charge.
Supply only ball bearing number of 6201/6202/6203/6204 as required. (Make : SKF/NBC) complete all as specified and directed by Engineer-in-Charge.
Supply only gun metal bush as required complete all as specified and directed by Engineer-in-Charge.
Taking down/dismantling complete Ceiling/exhaust fans of any size for spray painting with two coat of synthetic enamel paint of approved colour including filling cavities with filler on coat after cleaning all dust etc. including re-assembling the same and testing after writing of MES NO on completion complete all as specified and directed by Engineer-in-Charge.
Taking down/ dismantling of defective/rusted storage type hot water Geyser of 50/35/25 Ltr capacity from different locations by disconnecting inlet/outlet connections and taking out unserviceable parts by unscrewing bolts and nuts, de-scaling/cleaning inner shell, servicing etc. Checking defects, re-assembling and re-installing the Geyser in position, connection and testing complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Plug and socket type DB (Functional Unit) 20 Amps capacity with provision of single pole 20 amps MCB, plug top and earth plug, grouted flush to walls complete all as specified and directed by Engineer-in-Charge.
M&L for painting of Geyser complete in site by scraping/removing old spray paint with brush/emery paper and spray painting with two coat of synthetic enamel paint of white colour and marking MES number with synthetic enamel paint of black colour in good and proper size all as directed by Engineer-in-Charge.
S&F batton holder insulated body with back plate inluding 12 watts LED lamp complete all as specified and directed by Engineer-in-Charge.
S & F GI tube light grade galvanised of size 40 mm with all fitting and fixed to wall and celling or laid in floors for cable protection complete all as specdied and directed by Engineer-in- Charge.
S & F BLDC (brushless direct current) Motor Ceiling fan 1200 mm sweep 5 star rating , single phase 240 volts, power consumption 26 Watt to 32 Watt on turbo mode with remote control, 220 CUM/Min. single phase, 50Hz. 240 volts warranty 2 years on product complete and accessories. Make: Atomberg Gorilla/Havells Efficiencia Neo/Crompton/ White or equivalent of CG/Luminous/Orient complete all as pecified and directed by Engr-in-charge
Geyser storage type, electric driven of capacity 25 Ltrs 5 star rating incl grouting of bolts with nut of suitable size including cement work complete all as specified and directed by Engineer-in-Charge.
S&F Exhaust fan (Heavy duty) 300 mm sweep 230/240 volts single phase with self closing louvers GI off mode protection against birds etc and provision of cutting of walls suitabully for fixing exhaust fan and necessary plastering and making good the disturbed surface to match with existing ccomplete all as specified and directed by Engineer-in-Charge.
M&L for LED Batten with LED tube light integrated LED channel of capacity 10 Watt white colour complete all as specified and directed by Engr-In-charge. Make: Bajaj BCLSB 10WH or equvalent of complete all as specified and directed by Engineer-in-Charge.
S&F for PVC flexible pipes 15mm dia (heavy duty) both end socketed 450mm long for hot/cold water complete all as specified and directed by Engineer-in-Charge.
S&F for copper (CP) hot water pipe for Geyser, connection with check nut and washer complete all as specified and directed by Engineer-in-Charge.
M&L for PCC preparation including cutting up to 45 cm width and depth of the road/hard standing and making good disturbed surfaces by using PCC type C2(1:3:6) by using 40mm graded stone aggregate for the fixing the pipe/laying cables complete all as directed by the Engr. in Charge.
Supply and fixing MCCB TPN/TP 100 Amps 415 Volts of braking capacity 36 KA of 3 pole confirming to (Adjustable Thermal and Magnetic Release Setting with short circuit settings) complete taking down old unserviceable one and making necessary connections including all provisions for fixing in panel compartments as existing using necessary links of suitable metals and cleaning the terminals with CTC solutions complete all as specified and directed by Engineer-in-Charge.
All as per Ser Item Srl No 204 here-in-before but for 63 Amps with braking capacity 36 KA complete all as specified and directed by Engineer-in-Charge.
M&L for Boring hole across the Road/plinth/hardstanding/path/drain/pavement etc., suitable for inserting HDPE/GI pipe of upto 100mm dia bore pipe for 0.4 mpa working pressure for cable passing without damaging existing Raod/path/hardstanding/floor by trenchless technology or manual using necessary equipment complete all as specified and directed. ---------------------------------------------------------------------------------------------- Note : A sum of Rs. 1,88,408.00 will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 42 (Schedule of Credit) of Tender document
RANDHIR AND COMPANY
GOODWILL CONSTRUCTIONS
M/s GURFATEH BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .