Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.5 LAccepted-AOC LANE NO 5 HNO 560 SHAM VIHAR TALAB TILLO JAMMU | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹19.4 L+₹89,355 (4.83%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹19.8 L+₹1.4 L (7.30%)Rejected-Finance NEAR SURAJ ICE FACTORY TALAB TILLO JAMMU | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹19.9 L+₹1.4 L (7.73%)Rejected-Finance | L4 | Rejected-Finance Being L4 |
Tender Value
₹19.5 L
EMD Value
₹39,000
Closing Date
21 Nov 2022, 2:00 pmClosed
Executive Engineer
Executive Engineer University of Jammu
Construction of extension of existing department of Education at New Campus Electrical work
2022_UDJK_195635_1
enit 670 dated 02-11-2022
Open Tender
Electrical Works
Item Rate
30 days
University of Jammu
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
Executive Engineer University of Jammu
₹39,000
27 Jan 2025
11 Nov 2022
23 Nov 2022
11 Nov 2022
21 Nov 2022
11 Nov 2022
Amount
Wiring for light point/fan point/ceiling fan point/exhaust fan point/call bell point with 1.5 Sq. mm FRLS PVC insulated, copper conductor cable in surface/recessed medium class PVC conduit, with piano type switch, phenolic, laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq mm. FRLS PVC insulated copper conductor single core cable etc. as required. (Wire Make ISI Marked Havells/Anchor /HPL /KEI/Polycab) (Conduit Make - ISI Marked Anchor/High Power /AKG) Group ‘C’
Wiring for circuit/sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. (Wire Make ISI Marked Havells/Anchor/HPL/KEI/polycab) 2 x 1.5 + 1 x 1.5 Sqmm
-----------do-------------- 2 x 2.5 + 1 x 2.5 Sqmm
-----------do-------------- 2 x 6 + 1 x 6 Sqmm
-----------do--------------- 4 x 6 + 2 x 6 Sqmm
------------do--------------- 4 x 10 + 2 x 10 Sqmm
Supplying and fixing of following sizes of medium class PVC conduit along with the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required- ISI Marked Anchor/High Power /AKG) 25 mm dia
Supplying and fixing 5 amp to 32 amps rating, 240/415 volts, 10 KA C curve miniature circuit breaker of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make Havells /Anchor/ C&S/HPL) Single pole
Supply and Fixing following ratings,four pole,415 volts,isolator in the existing MCB DB Complete with connections,testing and commissioning etc. as reqd (Make Havells/Anchor/C&S/HPL) 63 Amp rating
Earthing with Copper earth plate 600mm x 600mm x 3mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/coke and salt as required.
Providing and fixing 4mm dia copper wire on surface or in recess for loop earthing as required.
Supply and fixing of metal Box of following size on the surface/recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 100mm x 100mm x 60mm deep
------------do-------------- 200mm x 125mm x 60mm deep
Supply & fixing 15/16 amp piano type switch on the existing switch box or cover including connection as required. (Make: Anchor/Havells /HPL/Great White/Sanchi major)
Supply & fixing 6 pin 15/16 amp socket outlet on the existing switch box or cover including connection as required (Make: Havells/ HPL/ Anchor/Great White/Sanchi major)
Supply & fixing 5/6 amp piano type switch on the existing switch box or cover including connection as required (Make :Havells/ HPL / Anchor /Great White Sanchi major)
Supply & fixing 3 pin 5/6 amp socket outlet on the existing switch box or cover including connection as required(Make: Havells/ HPL / Anchor /Sanchi major/Great white)
Supplying and fixing following ways and poles, plain/horizontal sheet steel MCB Distribution Board on surface/in recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections including powder painted earthing etc. as required (But without MCB/RCCB/Isolators. Havells/Anchor /I.A /HPL 8 way (4 + 24), Double door
Supply & fixing piano type Telephone socket outlet on the existing Switch Box or cover including connection as required (Make Havells/HPL/Anchor)
Supplying & drawing 2 pair (0.50)sq mm FR PVC insulated annealed copper conductor un armoured telephone cables in the existing surface/recessed steel or PVC Conduit as required (Make ISI Marked Havells/Anchor/ KEI/HPL)
Supply & fixing two module stepped type electronic fan regulator on the existing modular plate/switch box including connections but excluding modular plate etc. as required. (Make Havells/ HPL / Anchor /SSK/ C&S/Great White/Sanchi Major)
Supplying and fixing brass batten/Angle holder including connection etc. as required. (Make Havells/ HPL / Anchor / C&S/Great White/ Sanchi Major)
Providing and fixing following rating and breaking capacity MCCB with Thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Make Anchor /Havells /HPL/I.A) 630A, 50 KA, FPMCCB
------------do-------------- 400A, 35KA, TPMCCB
-------------do-------------- 200A, 25KA, TPMCCB
--------------do-------------- 150A, 16 KA, TPMCCB
--------------do-------------- 100A, 16 KA, TPMCCB
Laying of one number PVC insulated and PVC sheathed/XLPE power cable 1.1 KV grade of following size cables direct in ground including excavation and filling the trench etc. as required,but excluding sand cushioning and protective covering. Upto 35 Sqmm
------------do---------------- Above 95 upto 185 Sqmm
Earthing with G.I earth pipe 4.5 mtr. Long 40mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangements and watering pipe etc. as required.
Providing and fixing of lightning conductor finial, made of 25mm dia 300mm long, G.I tube, having single prong at top, with 85mm dia 6mm thick G.I. base plate including holes etc. compete as required.
Providing and fixing G.I. tape 20mmx3mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run)
Providing and fixing G.I tape 20mmx3mm thick on parapet or surface of wall for lightning conductor complete as required (For vertical run).
P/F M.V danger plate of (200x150) mm made of mild steel at least 2mm thick and vitreous enameled white on both side and with inscription in single red colour on front side as reqd.
Supply/Installation testing and commissioning of following type of surface /recessed mounted Indoor Linear/square or round downlighter/wall bracket/bulk head, environmental friendly energy efficient LED Light fittings complete. Make (Halonix/ Havells/ Syska/Bajaj/Greatwhite/ Philips/Crompt-on/compact) 4 feet 18 to 22 watt, 230 volts LED batten type tube light fitting complete.
-------d----- 2 feet 09 to 12 watt, 230 volts LED batten type tube light fitting complete.
-----------do-------- 18 To 22 Watt LED recessed / Surface mounting down, 6500 K, 240 Volts as per cat: GARNET Slim Panel Light square/ Round 900 to 1200mm dimension complete.
-----------do---------- Wall Brackets fittings as per Cat. No HLWB-01-B22 Suitable for 15-20 watt LED Bulb including the cost of Bulb.
-----------do------------ Bulk Head as per cat HLBH-02-10-CW suitable for 10-15 watt LED Bulb including the cost of Bulb.
Supply/installation, testing and commisioning of the following type of outdoor LED type bollard light/ floodlight /Street lights/post light luminaries complete with all accessories. Make (Bajaj/Legrand /Surya /Havells/ C&S/ compact) 45 to 60 watt,230 volts IP 66/ IP 65
Design, manufacture, testing at works & supply, installation, testing & commissioning cubicle panel floor mounted (on base frame) totally enclosed and extensible type . The general construction shall comprise to IS 8623-93. The design shall include all provisions for safety of operating and maintenance personal. IP 42 for indoor and IP54 for outdoor, shall be compartmentalized type having space and arrangements for I/C. cable/bus ducting/incoming switch gears, bus couplers, insulated and properly supported compartmentalized switch gear, outgoing compartmentalized switch gear, bus bar support and terminations, interconnection between bus bars & switch gear with auxiliary bus bars/insulated conductors/strips etc. The panel shall be fabricated out of CRCA not less than 2.00 mm thick for the load bearing members and 1.6mm for doors of L.T Panels. The frame work may be Agle Iron/Channel/Bolted type construction should be arrangement for I/C/O/G. Cable termination with 2 Each. 20x5mm cu. Strip fixed all around the panel connected to 2 Each. earth bars cu-strips connected to incoming earth conductor. (Make Electric Field/ Bharti Engineers/Gupta & Friends/ Gaytri) MAIN OUTDOOR /BUILDING CONTROL PANEL OUTDOOR TYPE a. INCOMING Space for 1 No. 630 Amp TPN Al. Bus bar of equal cross section for Main Power connection to Main MCCB. Space for 1 No. 630 Amp 4 pole MCCB of 50KA Space for 1 no. 3-phasedigital type energy meter. b. INDICATING PANEL The indicating panel of the incomer shall be provided with the following: i. Ammeter of required range with ASS, CT's. ii.Voltmeter of required range with VSS. c. OUTGOING Space for 1 No. 600 Amp TPN Al. Bus bar of equal cross section for power load/light load connection to the new and the existing building. Dimension = 4’ x 3’ x 1’6”
----------do------------ MAIN NORMAL CUM EMRENGECY PANEL (Compartmental Type) a. INCOMING Space for 1 No. 315/400,4 pole Amp main MCCB Space for 1 No. 200 Amp 4 pole change over switch b. INDICATING PANEL The indicating panel of the incomer shall be provided with the following: i. Ammeter of required range with ASS, CT's. ii.Voltmeter of required range with VSS. c. BUS BAR Space for 1 No. 400 Amp TPN Al. bus bar of equal cross section for power load with provision/space for 06 nos 40 amp double pole isolator for AC system. Space for 1 No. 300 Amp TPN Bus bar of equal cross section for light load. d. OUTGOING Space for minimum 02 No. and 100 Amp 4 pole MCCB for power and light load of 1st floor. Dimension = 5’x 4’ x 1’-6”
-----------do---- SUB PANEL FOR POWER LOAD a. INCOMING Space for 1 No. 200,4 pole Amp main MCCB b. INDICATING PANEL The indicating panel of the incomer shall be provided with the following: i. Ammeter of required range with ASS, CT's. ii.Voltmeter of required range with VSS. c. BUS BAR Space for 1 No. 200 Amp TPN Al. bus bar of equal cross section for power load with provision/space for 06 nos 40 amp double pole isolator for AC system. d. OUTGOING Space for minimum 02 No. 100 Amp 4 pole MCCB for power load of 2nd floor. Dimension = 3’x 3’ x 1’-6”
------------do--------- SUB PANEL FOR LIGHT LOAD a. INCOMING Space for 1 No. 150,4 pole Amp main MCCB b. INDICATING PANEL The indicating panel of the incomer shall be provided with the following: i. Ammeter of required range with ASS, CT's. ii.Voltmeter of required range with VSS. c. BUS BAR Space for 1 No. 200 Amp TPN Bus bar of equal cross section for light load. d. OUTGOING Space for minimum 03No. and 100 Amp 4 pole MCCB for power and light load of 2nd floor. Dimension = 3’x 3’ x 1’-6”
Supply, testing and commissioning of PVC sheathed Aluminum conductor 1100 volts graded PVC AA Armoured/unarmoured XLPE Cable including end termination, crimping, cost of thimbles, nuts bolts, glands, connection, testing and commissioning complete job. (Make: Havells / General/Polycab / Gloster) 2 core 16 sq mm armoured cable
-----------do--------------- 3 ½ core 35 sq mm armoured cable
Supply, installation, testing, commissioning of 1200 mm sweep ceiling fans complete with blades BEE 3 to 5 star rated energy efficient. (Make: Havells /Anchor/Bajaj /Compact)
Supply, installation, testing, commissioning of heavy duty 300 mm sweep BEE 3 to 5 star rated energy efficient exhaust fan. Make: ( Anchor/Havells/Bajaj/Crompton)
Supply & installation of CAT 6 2 module toll less information outlets complying fully or exceeding with category 6 connecting hardware specifications for all pair combinations upto 250 MHz. Outlets shall use lead frame technology, non PCB pyramid type complete as required. (Make Legrand/Delton/Havells/HPL/Anchor)
Supply and installation of Singlex Face Plates along with clearly printed labels and holders complete as required (Make Legrand /Havells / Anchor/D Link /HPL)
Supply and installation of CAT 6 pair 23 AWG UTP Networking System Cable with cross member pair separator complete as required (Make Legrand /Havells / Anchor/D Link /HPL)
Providing/fixing 40 amp rating , 230 volts SPN MCB in the existing MCB DB or enclose complete with connection testing and commissing complete Job. (Havells/Anchor/HPL make)
S/F of 20mm dia G.I pipe for flood light bracket including bending to shape, (40x3)mm flat iron clamp and wiring with 1.5 sqmm PVC insulated wire complete wire complete as reqd.
P/laying of 100 mm dia heavy duty PVC pipe in ground including digging the pit and refilling complete job. (Prince/Supreme/Astral/Uniplas)
Supply and fixing of onload I-O-II Four pole with advanced neutral change over switch. (Make Legrand/ I.A/Havells /Siemen/HPL) 200 Amp 4Pole,415 volts
durgaengineers & co
Harjeet Singh
Northern Power Infra LLP
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .