Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.2 LAccepted-AOC | L1 | Accepted-AOC ACCEPT | |
| 2 | L2₹18.3 L+₹4.1 L (29.2%)Rejected-AOC | L2 | Rejected-AOC REJECT | |
| 3 | L3₹18.6 L+₹4.4 L (31.0%)Rejected-AOC A 04 ADGNJ CHANDAN NAGAR OPP IOCL PETROL PUMP RAMPUR ROAD BAREILLY U P 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | L3 | Rejected-AOC REJECT |
Tender Value
₹14.2 L
EMD Value
₹14,200
Closing Date
3 Nov 2023, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE EWC
Bareilly
Replacement of damage 33 KV underground in distt. Shahjahanpur
2023_MVVNL_854818_1
18/EWC(B)/2023-24
Open Tender
Electrical Works
Item Rate
90 days
Shahjahanpur
As per tender form
3 documents required · 3 mandatory
₹3,540
SE EWC
₹14,200
3 Apr 2024
21 Oct 2023
3 Nov 2023
21 Oct 2023
3 Nov 2023
21 Oct 2023
Amount
(A) REPLACEMENT OF DAMAGE 33 KV U/G CABLE RAILWAY CROSSING NEAR MARGHAT from 33/11 KV S/S BAHADURGANJ
Carriage of following line materials for 33 KV line from any Store Centre of Bareilly zone, Bareilly to site of work including measuring, weighing, loading, unloading at both ends and proper stacking at safe site.
33 KV 3X300mm2 XLPE Cable
33 KV 3X300mm2 XLPE Cable jointing kit O/D
ST pole 11 Mtr. Long
M.S. Earthing rod
M.S angle 65x65x6mm, 2700mm
Top channel 125x65x6mm 3200mm
11 KV disc insulator B&S type 70 KN
Disc fitting Dog/Racoon 70 KN
Complete Stay set complete
Erection of the following supports including cutting, making holes, fixing of all types of accessories digging of pits complete in all respect, as per RESSPO drawing. All types of clamps, stone pad, nut, bolt washers would be provided by the contractor.
End type double pole structure on S.T. Pole 11mtr long complete with bracing.
Erection/fixing for stay set with stay wire and clamp as per RESSPO drawing including binding, clamping, tightening, and nozzeling etc. complete in all respect including its grouting in ratio 1:4:8 of cement, sand and brick ballast and sand before back filling of the pits as per RESSPO schedule all clamps, nuts & bolts, cement, brick, concrete etc would be provided by contractor.
Concreting of supports in 1:4:8 ratio and plinthing of supports upto 300mm above ground level by using cement ,brick ballast and sand in ratio 1:4:8 as per RESSPO drawing with watering/curing properly upto proper setting of plinthing.All matrial would be provided by the contractor.
Earthing of each S.T Poles of the line is to be done by inserting the MS earth rod (1800x20mm) into soil by hammering and properly fastning with GI wire to each support by nut & bolt. Earthing rod must be 0.15Mtr.above from the plinth of the support. All type nut & bolt would be given by the contractor.
Painting of following supports with one coat of red oxide primer and two coats of aluminum white paint of ISI mark and top danger portion of each support must be painted by providing two coat of Post Office Red Paint (1.5mtr upper portion of support.) Paint and material would be given by contractor to complete the job.
End type double pole structure on S.T. Pole 11mtr long complete with bracing.
Making of triangular bridge by using MS electrode, GI strip 50x6mm and GI Pipe 40 mm dia with providing of well type pipe earthing upto 15 Mtr. depth below ground level including welding etc. by boaring process at double pole of railway crossing and newly erected structure including cost of GI pipe of size 40 mm dia 15 mtr. long of ISI mar(all the required material will be supllied by the contractor).
Cable laying by drill method single circuit in HDPE Pipe including fixing of cable route marker with difference of 50 mtr. at time of cable laying with complete engraved details of 33 KV Line and depth of 33 KV cable.
Fixing of danger board on each location and G.I barbed wire including proper clamping and providing anti climbing device by using including supply of the above items.
Hoisting of 33 KV 3X300 Sq. mm. XLPE cable on double pole with GI pipe of size 6" dia 3 M long including its jumpering complete with clamps, nuts and bolts.
Fixing of 33 KV O/D Cable Jointing Kit
caraige of reciev back material from site to store centre spn
(B) REPACEMENT OF DAMAGE 33 KV U/G CABLE NEAR TILHAR SUB-STATION CROSSING OF 33 KV LINE KHUDAGANJ RURAL LINE OF LENGTH 185 MTR SINGLE CKT.
Carriage of following line materials for 33 KV line from any Store Centre of Bareilly zone, Bareilly to site of work including measuring, weighing, loading, unloading at both ends and proper stacking at safe site.
33 KV 3X300mm2 XLPE Cable
33 KV 3X300mm2 XLPE Cable jointing kit O/D
Laying of single circuit 33 KV 3X300 Sq. mm XLPE cable in normal soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand, 1st class bricks, stone slab. Inter axial spacing between the two cable should be in between 0.25 m to 0.40m including fixing of cable route marker with difference of 50 mtr. at time of cable laying with complete engraved details of 33 KV Line and depth of 33 KV cable. (All the material required for laying will be supplied by the contractor except 33 KV XLPE cable)
Hoisting of 33 KV 3X300 Sq. mm. XLPE cable on double pole with GI pipe of size 6" dia 3 M long including its jumpering complete with clamps, nuts and bolts.
Fixing of 33 KV O/D Cable Jointing Kit
(C) REPLACEMENT OF DAMAGE 33 KV U/G CABLE NEAR VILLAGE JINAURI OF 33 KV LINE KHUDAGANJ RURAL LENGTH 90 M. DOUBLE CKT
Carriage of following line materials for 33 KV line from any Store Centre of Bareilly zone, Bareilly to site of work including measuring, weighing, loading, unloading at both ends and proper stacking at safe site.
33 KV 3X300mm2 XLPE Cable
33 KV 3X300mm2 XLPE Cable jointing kit O/D
Laying of double circuit 33 KV 3X300 Sq. mm XLPE cable in normal soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand, 1st class bricks, stone slab. Inter axial spacing between the two cable should be in between 0.25 m to 0.40m including fixing of cable route marker with difference of 50 mtr. at time of cable laying with complete engraved details of 33 KV Line and depth of 33 KV cable. (All the material required for laying will be supplied by the contractor except 33 KV XLPE cable)
Hoisting of 33 KV 3X300 Sq. mm. XLPE cable on double pole with GI pipe of size 6" dia 3 M long including its jumpering complete with clamps, nuts and bolts.
Fixing of 33 KV O/D Cable Jointing Kit
(D) REPLACEMENT OF 33 KV U/G CABLE NEAR 132 KV SUB-STATION POWAYAN SWITCH YARD TO POWAYAN ROAD OF 33KV LINE POWAYAN RURAL SECOND OF LENGTH 220 MTR.SINGLE CKT.
Carriage of following line materials for 33 KV line from any Store Centre of Bareilly zone, Bareilly to site of work including measuring, weighing, loading, unloading at both ends and proper stacking at safe site.
33 KV 3X300mm2 XLPE Cable
ST pole 11 Mtr. long SP-55
M.S angle lron 65x65x6mm, 4300mm
Top channel 125x65x6mm 3200mm
11 KV Disc Insulator B &S. Type 7000 Kg
Disc Fittings Dog/Racoon 7000 Kg
Complete Stay (GI stay rod 20x1800mm, stay wire 7/8 SWG 10 kg, stay clamp, bolt, nut & washer
Stay insulator
Earthing of pole by MS earthing rod of 20x2500mm. And 6 SWG earthing wire etc.
33 KV 3X300mm2 XLPE Cable jointing kit O/D
Erection of the following supports including cutting, making holes, fixing of all types of accessories digging of pits complete in all respect, as per RESSPO drawing. All types of clamps, stone pad, nut, bolt washers would be provided by the contractor.
End type double pole structure on S.T. Pole 11mtr long complete with bracing.
Erection/fixing for stay set with stay wire and clamp as per RESSPO drawing including binding, clamping, tightening, and nozzeling etc. complete in all respect including its grouting in ratio 1:4:8 of cement, sand and brick ballast and sand before back filling of the pits as per RESSPO schedule all clamps, nuts & bolts, cement, brick, concrete etc would be provided by contractor.
Concreting of supports in 1:4:8 ratio and plinthing of supports upto 300mm above ground level by using cement ,brick ballast and sand in ratio 1:4:8 as per RESSPO drawing with watering/curing properly upto proper setting of plinthing.All matrial would be provided by the contractor.
Earthing of each S.T Poles of the line is to be done by inserting the MS earth rod (1800x20mm) into soil by hammering and properly fastning with GI wire to each support by nut & bolt. Earthing rod must be 0.15Mtr.above from the plinth of the support. All type nut & bolt would be given by the contractor.
Painting of following supports with one coat of red oxide primer and two coats of aluminum white paint of ISI mark and top danger portion of each support must be painted by providing two coat of Post Office Red Paint (1.5mtr upper portion of support.) Paint and material would be given by contractor to complete the job.
End type double pole structure on S.T. Pole 11mtr long complete with bracing.
Laying of single circuit 33 KV 3X300 Sq. mm XLPE cable in normal soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand, 1st class bricks, stone slab. Inter axial spacing between the two cable should be in between 0.25 m to 0.40m including fixing of cable route marker with difference of 50 mtr. at time of cable laying with complete engraved details of 33 KV Line and depth of 33 KV cable. (All the material required for laying will be supplied by the contractor except 33 KV XLPE cable)
Fixing of danger board on each location and G.I barbed wire including proper clamping and providing anti climbing device by using including supply of the above items.
Hoisting of 33 KV 3X300 Sq. mm. XLPE cable on double pole with GI pipe of size 6" dia 3 M long including its jumpering complete with clamps, nuts and bolts.
Fixing of 33 KV O/D Cable Jointing Kit
M/S SUPER ENGINEERING TRADERS
BHARAT ELECTRICAL TRADERS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .