Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹90.5 LAccepted-AOC FLAT NO 151 BLOCK NO 1 DIAMOND SQUARE CGHS LTD PLOT NO 13A SECTOR 6 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹93.7 L+₹66,741.90 (0.72%)Rejected-Finance 126 NARANG COLONY JANAK PURI NEW DELHI 110058 | NEW DELHI | NEW DELHI | DELHI | 110058 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹1.0 Cr+₹10.5 L (11.3%)Rejected-Finance POCKET A 2 310 SECTOR 08 ROHINI NEW DELHI 110085 | NEW DELHI | NORTH WEST DELHI | DELHI | 110085 | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹1.1 Cr+₹19.3 L (20.8%)Rejected-Finance TP 117 2ND FLOOR MAURYA ENCLAVE PITAMPURA DELHI 110034 | DELHI | DELHI | DELHI | 110034 | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹1.2 Cr+₹28.0 L (30.1%)Rejected-Finance RZ 55 1ST FLOOR MOHAN NAGAR PANKHA ROAD NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L5 | Rejected-Finance Not being lowest |
| Sl No | Description | Qty | Unit | M/s. Kansal Construction Co. L3 | GLIBS CONSTRUCTION L4 | Ashish Sehgal and Co. L5 | Atish Builders LLP L2 | BRIJ MOHAN LAL AND CO. L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out any type of soil complete all as specified and directed. | 123.29 | Cum | 300 ₹36,987 | 250 ₹30,822.5 | 150 ₹18,493.5 | 200 ₹24,658 | 100 ₹12,329 Lowest |
| 2.00 | Material & Labour for excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/disintegrated rock complete all as specified and directed. | 661 | Cum | 200 ₹1,32,200 | 400 ₹2,64,400 | 1,000 ₹6,61,000 | 400 ₹2,64,400 | 100 ₹66,100 Lowest |
| 3.00 | Returning, filling in any type of soil including spreading, watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed. | 69.93 | Cum | 50 ₹3,496.5 | 100 ₹6,993 | 100 ₹6,993 | 30 ₹2,097.9 Lowest | 100 ₹6,993 |
| 4.00 | Returning, filling in soft/disintegrated rock including spreading, watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed. | 559 | Cum | 100 ₹55,900 | 100 ₹55,900 | 100 ₹55,900 | 30 ₹16,770 Lowest | 100 ₹55,900 |
| 5.00 | Removal of excavated (soil) and bldg material (stone/cement mortar/concrete/etc) for a distance exc 5KM but n.exc 10KM and depositing outside the defence premises on desecration of Contractor, complete all as specified and directed. | 232.83 | Cum | 240 ₹55,879.2 | 500 ₹1,16,415 | 200 ₹46,566 Lowest | 250 ₹58,207.5 | 400 ₹93,132 |
| 6.00 | Removing excavated material n exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. | 32 | Cum | 240 ₹7,680 | 100 ₹3,200 Lowest | 200 ₹6,400 | 150 ₹4,800 | 100 ₹3,200 Lowest |
| 7.00 | Removal of excavated (soft/disintegrated rock) for a distance exc 5KM but n.exc 10KM and depositing outside the defence premises on descretion of Contractor complete all as specified and directed. | 102 | Cum | 240 ₹24,480 | 500 ₹51,000 | 200 ₹20,400 Lowest | 540 ₹55,080 | 400 ₹40,800 |
| 8.00 | Taking down cement or cement lime plaster on brick walls including racking out joints hacking for key scrubbing down with water etc complete all as specified and directed. | 2,407 | Sqm | 10 ₹24,070 | 10 ₹24,070 | 10 ₹24,070 | 5 ₹12,035 Lowest | 20 ₹48,140 |
| 9.00 | Material & Labour for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth with out using extra cement upto four storey complete all as specified and directed. | 1,634 | Sqm | 170 ₹2,77,780 | 200 ₹3,26,800 | 200 ₹3,26,800 | 180 ₹2,94,120 | 150 ₹2,45,100 Lowest |
| 10.00 | Material & Labour for rendering 10mm thick in CM 1:6 on other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement up to four storey height bldg complete all as specified and directed. | 694 | Sqm | 170 ₹1,17,980 | 200 ₹1,38,800 | 180 ₹1,24,920 | 175 ₹1,21,450 | 150 ₹1,04,100 Lowest |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
21 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Palam
CWE (AF) Palam, Delhi Cantt-10
IMPROVEMENT TO CERTAIN BUILDINGS OF OFFICERS MESS AND SNCOS MESS AT SUBROTO PARK UNDER GE (AF) SUBROTO PARK, DELHI CANTT-10
2025_MES_713927_1
CWE/PM/SP-05/2025-26
Open Tender
Civil Works
Item Rate
330 days
Subroto Park
Please refer Tender documents.
10 documents required · 10 mandatory
₹1,000
GE (AF) Subroto Park
₹2.2 L
29 Aug 2025
12 Jun 2025
28 Jul 2025
12 Jun 2025
21 Jul 2025
7 Jul 2025
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out any type of soil complete all as specified and directed.
Material & Labour for excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/disintegrated rock complete all as specified and directed.
Returning, filling in any type of soil including spreading, watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed.
Returning, filling in soft/disintegrated rock including spreading, watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed.
Removal of excavated (soil) and bldg material (stone/cement mortar/concrete/etc) for a distance exc 5KM but n.exc 10KM and depositing outside the defence premises on desecration of Contractor, complete all as specified and directed.
Removing excavated material n exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
Removal of excavated (soft/disintegrated rock) for a distance exc 5KM but n.exc 10KM and depositing outside the defence premises on descretion of Contractor complete all as specified and directed.
Taking down cement or cement lime plaster on brick walls including racking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
Material & Labour for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished even and smooth with out using extra cement upto four storey complete all as specified and directed.
Material & Labour for rendering 10mm thick in CM 1:6 on other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement up to four storey height bldg complete all as specified and directed.
Material & Labour for rendering 5mm thick in CM 1:3 on ceiling surfaces finished even and smooth without using extra cement complete all as specified and directed.
Demolition of brick work or stone/boulder masonry built in cement mortar complete all as specified and directed.
Material & Labour for brick work with subclass 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
Material & Labour for complete removal of existing treatment on external & internal wall surfaces (old plastered surfaces) complete all as specified and directed.
Material & Labour for Providing and applying (1 to 2) mm thick wall care putty on wall plastered surface/concrete surface and prepare the surface even and smooth complete all as specified and directed.
Material & Labour for preparation of new surfaces of walls, and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces upto four storey bldgs complete all as specified and directed.
Material & Labour for preparation of new surfaces of walls, and applying two coats of distemper oil emulsion over a coat of alkali resistant primer on wall surface complete all as specified and directed.
Material & Labour for preparation of new plastered surfaces and applying two coats of plastic paint over a coat of primer on wall surfaces complete all as specified and directed.
Material & Labour for preparation of new plastered or unplastered surface and applying three coats of white wash on wall complete and all as specified and directed.
Material & Labour for preparation of new plastered or unplastered surface and applying three coats of white wash on ceiling complete and all as specified and directed.
Material & Labour for preparation of old plastered surface and applying two coats of white wash on ceiling surfaces complete all as specified and directed.
Dismantling loose concrete cover of RCC column, beams, slabs, chajjas and the like as directed, roughening and cleaning concrete surface with steel wire brushes, washed with water and allowed to dry, incl derusting of steel reinforcement, providing fabric mild steel wire mesh 75x75x2 mm dia as reinforcement to concrete. after placing the additional reinforcement all concrete surface shall thoroughly scrubbed with brushes, washed with water and allowed to dry. To this surface apply chemical polycrete admixture at the rate not less than 2% by weight of cement and providing minimum 30 mm thick (average thickness) guniting mix (using 1 part of ordinary portland cement 53 Grade and 2 parts of ghaggar sand mixed with adhesive/admixture at the rate as directed) with a pressure of 2 to 2.5 kg per sqcm by guniting machine and surfaces finished even and fair, incl necefssary padding ,shuttering /form work 15 mm thick plaster in CM (1:4) and removing the debris outside MD land complete all as specified and directed. Note:- Quoted rates shall deemed to be inclusive of all form work and scafolding or other any special handy T&P required to make up proper shape and size of columns/ Pillars, beam and wall partition etc.
Demolition of reinforced cement concrete of roofs, floors, beams, staircases, landing, chajjas, slab, Parapet wall and similar suspended work (reinforcement cut as required to facilitate demolition) complete all as specified and directed.
Material & Labour for Formwork flat rough finished surfaces to chullah hoods, chajjas, counter slab, troughs and similar items including edge complete all as specified and directed.
Supply & Fixing for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia upto four storey complete all as specified and directed.
Material & Labour for Reinforced cement concrete (nominal mix) 1:2:4, type B-1 using (20mm graded aggregate) in slabs supported on walls, beams and column in floors, roofs, landings, balconies, canopies, deck slabs and in chajjas/ shelves and the like complete all as specified and directed.
Demolition and complete removal of existing roof treatment with mud phuska including bedding layer in cement mortar/plastering/leeping (whether full thickness removed or only a part thereof) complete all as specified and directed.
Material & Labour for cement concrete type B0 1:2:4 using 12.5mm graded aggregate in roof kerbs or mud stops, padding, rounded or chamfered on edges without using extra cement complete all as specified and directed.
Material & Labour for plaster 10 mm thick in cement mortar 1:4 on fair faces of brick or concrete surfaces finished even and smooth with integral water proofing compound as per manufacturers instructions complete all as specified and directed. Note : WPC shall be paid and measured separately under relevant item
Supply only liquid water proofing compound complete all as specified and directed.
Material & Labour for preparation of plastered/concrete surfaces of roof and applying the under mentioned course of roof treatment complete all as specified and directed.- (a) Surface shall be thoroughly wire brushed, cleaned, washed, dried up properly and apply evenly a bituminous primer coat conforming to IS @0.4 ltr /Sqm over concrete/ plastered roof surface. (b) Applying evenly a bonding coat of bitumen 85/25 grade @1.20 kg/ sqm. (c) Laying of 3mm thick APP membrane sheet (min weight 3 Kg/Sqm) consisting of a core of 160 gms/Sqm polyester non woven fabric mat protected on both sides with a high quality polymeric asphaltic mix again protected with thermo fusible HMHDPE FILM on dried primed surface by torch application method. APP membrane will normally be laid in length at right angle to the direction of slope. The over lap shall be minimum 100mm on longitudinal direction and 150mm on the transverse direction including cuttings, grooves etc. (d) Membrane bonded completely to the substrate & the overlaps are then scaled/fused by flame. Note:- This treatment shall be done by the approved authorized applicators and guarantee of treatment shall be minimum 10 years complete all as specified and directed.
Material & Labour for two coat of water proofing aluminium paint finish including preparation of newly or previously untreated surfaces of any description, over 10cm width or girth, not otherwise described complete all as specified and directed.
Demolition to stone slab and granite laid bedded and pointed in any mortar of any description or thickness in floors/pavings/cladding etc and removing the debris outside the MOD land complete all as specified and directed.
Material & Labour for 18-20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and including providing edge moulding complete all as specified and directed.
Material & Labour for Pre polished Machine cut kota stone flooring 20-22mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab, and including 15 mm Screed bed or bedding layer of CM 1:4 complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for, complete all as specified and directed.
Material & Labour for 75mm thick PCC 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in floors without using extra cement, complete all as specified and directed.
Material & Labour for 50 mm thick PCC 1:3:6 type C2 as in Plinth Protection using 40 mm stone aggregate including making joints and filling with sand bitumen mastic as per complete all as specified and directed.
Material & Labour for sand filling for sand cushioning for laying of interlocking paver blocks under floors/path including watering and consolidation as required complete all as specified and directed.
Material & Labour for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment including dismantling of old damage paver blocks complete all as specified and directed..
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Material & Labour for Vitrified Ceramic tiles 10mm thick light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 15mm thick screed bed in cement mortar (1:4) complete all as specified and directed.
All as per serial item No 42 but on vertical surface such as skirting, including Rendering/backing 10mm thick in CM 1:4 on brick wall surfaces, other than fair faces of brick work finished even and fair to receive tiles, complete all as specified and directed.
Material & Labour for Glazed ceramic coloured tiles in vertical surface 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including backing/rendering 10 mm thick in cm 1:4 complete all as specified and directed.
Material & Labour for Non-skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement mortar (1:4) complete all as specified and directed.
Material & Labour for Rubber moulded chequered tile glossy finished (Size 30cm x 30cm x 25mm) thick, machine pressed; set jointed and pointed in neat cement slurry in floors, with grey cement and color pigment and cut and polished laid over including 15 mm Screed bed or bedding layer of CM 1:4, complete all as specified and directed.
Taking down Chowkats or frames with shutters (without taking off shutters from the frame) area exc 1.5 sqm and not n.exc 4.0 sqm each complete all as specified and directed.
Supply & Fixing aluminium powder coated any colour (minimum thickness of powder coating 50 micron) frame (sliding and shutter type) for doors, windows, partition, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
Supply & Fixing for powder coated aluminium doors (sliding), (thickness of powder coating not less than 50 micron) aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, anodised aluminium snap beading screws etc. complete all as specified and directed
Supply & Fixing 12mm thick particle board prelaminated on both sides as in panel of door shutters partition wall, work stations including beading etc.omplete all as specified and directed
Supply & Fixing for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows and other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) and 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
Supply & Fixing for Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately) complete all as specified and directed.
Supply & Fixing for 100mm long butt hinges medium weight, mild steel, and fixed complete all as specified and directed.
Supply & Fixing for 125mm long aluminium anodised, barrel tower bolts of ex-truded section and fixed complete all as specified and directed.
Supply & Fixing for 125mm long Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
Supply & Fixing Aluminium (extruded section body) Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Material & Labour for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening confirming Fe-290 (Gde E- 165) and fixing complete all as specified and directed. .
Material & Labour for 1.00mm thick mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed
Supply & Fixing for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; drain cover grating, framed balusters; walk ways; railings; cooler stand, framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed.
Supply & Fixing for Mild Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161- 1979 grade St.-240. complete all as specified and directed.
Material & Labour for Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide/ zinc primer upto four storey height building chromate complete all as specified and directed.
Dismantling plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
Material & Labour for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 MPa as in roof covering/cladding to wall, fixed with selftapping screws, complete all as specified and directed.
Material & Labour for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 MPa as in ridge/roof covering/cladding to wall, fixed with selftapping screws, complete all as specified and directed.
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed.
Supply & Fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595 x 595 mm of approved texture, design and patterns with semi perforated 12mm thick micro regular edged GRG false ceiling tiles having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600x 600mm ,suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions by GE.
Supply and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed.
Material & Labour for cutting out decayed brickwork and refacing with new bricks (1 course of headers to 3 courses of stretchers) and making good with cement mortar 1:4 complete all as specified and directed.
Material & Labour for providing precast cement concrete louvers and jalies made out of cement concrete type B0 1:2:4 (12.5mm graded aggregate) set in cement mortar (1:4) 25 mm thick (measured solid) including all moulding complete all as specified and directed.
Material & Labour for preparing new surfaces on walls plastered or unplastered and applying two coats of cements base paint over a coat of cement primer complete all as specified and directed.
Dismantling existing water tank and removing from site and Supply & Fixing for Rotational moulded PVC water storage tanks of 1000 Ltr capacity, cylindrical vertical with closed top hoisted as per IS and fixed in position including necessary fittings complete all as specified and directed.
Supply & Fixing for 20 mm dia Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
Supply & Fixing for PVC (SWR) pipes 110mm single socketed, in any length with solvent cement joints fixed to walls/laid in floors including stack clamps of stainless steel with bolts & nuts etc and also including taking down old rain water pipes with fittings, complete all as specified and directed.
Supply & Fixing for PVC (SWR) pipes 75mm single socketed, in any length with solvent cement joints fixed to walls/laid in floors including stack clamps of stainless steel with bolts & nuts etc and also including taking down old rain water pipes with fittings, complete all as specified and directed.
Supply & Fixing for PVC SWR bends 110mm bore complete all as specified and directed.
Supply & Fixing for PVC SWR bends 75m bore complete all as specified and directed.
Supply & Fixing 20mm bore medium grade galvanised steel water tubing ISI marked with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed.
Supply & Fixing 15mm bore medium grade galvanised steel water tubing ISI marked with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed.
Supply & Fixing in repair sinks made of stainless steel 1mm thick kitchen with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm, bowl size 410mm x 330mm x 160mm complete all as specified and directed.
Supply & Fixing in repairs Wash basins, Vitreous China (flat back or angle back type) any size, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe complete all as specified and directed.
Supply & Fixing in repair PVC SWR floor trap with grating including jointing with solvent cement 75 mm dia complete all as specified and directed.
Supply & Fixing in repair for Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm half stall type white (minimum), with grating and union for discharge pipe complete all as specified and directed
Material & Labour for Vitreous china urinal partition white of size 310x700 mm complete as specified as directed
Supply & Fixing in repairs CP Towel rail 450mm long fixed with and including chromium plated brass screws and wooden/plastic cleats complete all as specified
Supply & Fixing in repair for vitreous china wash down water closet pan, white (pedestal pattern), including plastic water closet seat, black/white, closed pattern with recessed bottom and cover and mild steel chromium plated or aluminised hinging device, excluding fixing bolts, flushing cistern and flush pipe complete all as specified and directed.
Supply & Fixing in repair 10 ltr capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets Flush pipe of polyethylene of low or high density or PVC 32 mm dia, for low level cistern complete all as specified and directed.
Supply & Fixing in repair 15mm dia PVC Connection 600mm long with nuts complete all as specified and directed.
Supply & Fixing in repair for health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed.
Supply & Fixing in repairs 15 mm bore, cast copper alloy, bib taps, chromium plated and fancy type high pressure screwed down for pipes etc complete all as specified and directed.
Supply & Fixing in repairs 15mm Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe etc complete all as specified and directed.
Supply & Fixing in repairs stop valve, cast copper alloy, chromium plated, fancy type screwed both ends for iron pipe of 15mm bore. complete all as specified and directed.
Dismantling boarding, any description, fixed in any position, any thickness & any type, complete all as specified and directed.
Supply & Fixing factory made 18mm(+0.7mm) thick celuka PVC Ply of density 600kg/cbm. One side prelam and other side plain 18mm thick Celuka PVC ply for kitchen cabinet and cupboards shutter and also manufacturer's test report and test certificate is mandatory with each and every supply of the material complete as per directions of Engr-in-charge, and as per manufacturer's specifications and drawing.
Supply & Fixing factory made 5mm thik PVC sheet of density 600kg/cbm. Plain 5mm thick PVC sheet paneling for back side (wall side) and also manufacturer's test report and test certificate is mandatory with each and every supply of the material complete as per directions of Engr-in-charge, and as per manufecturer's specifications and drawing.
Supply & Fixing factory made 18mm (+0.7mm) thick celuka PVC Ply of density 600kg/cbm manufactured by an ISO-900-2008 certified company.Plain 18mm thick Celuka PVC Ply for Shelf/Partitions/Drawer and also manufacturer's test report and test certificate is mandatory with each and every supply of the material complete as per directions of Engr-in-charge, and as per manufacturer's specifications and drawing.
Supply & Fixing continuous (piano) hinges, mild steel, bright finish or electrogalvanised of width of flaps (when open) is 40mm for CB Shutter and kitchen cabinet etc complete all as specified and directed.
Material & Labour for 125mm magnetic catches with brass body and striking plate including letting in and fixed complete all as specified and directed.
Supply & Fixing 100mm long Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
Supply & Fixing in repair 15 mm bore brass CP wash hand basin mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed.
Supply & Fixing in repairs 15mm dia Brass CP wall mixer for mixing hot & cold water screwed down for iron pipe complete all as specified and directed.
Material & Labour for cement concrete 1:4:8 type D-2 concrete bed to drain pipe of 200mm dia including packing under and haunching against the side of pipes after they are laid and tested, complete all as specified and directed.
Material & Labour for cement concrete 1:4:8 type D-2 concrete bed to drain pipe of 250mm dia including packing under and haunching against the side of pipes after they are laid and tested, complete all as specified and directed.
Supply & Fixing 200mm bore/Inner Dia double wall corrugated HDPE pipes (SN8) in any length , laid in trenches or in floors complete all as specified and directed.
Supply & Fixing 250mm bore/Inner Dia double wall corrugated HDPE pipes (SN8) in any length , laid in trenches or in floors all as specified and directed.
Demolition and breaking of 200mm dia drain pipes (salt glazed ware, AC or reinforcement concrete) set in cement mortar all as specified and directed.
Demolition and breaking of 250mm dia drain pipes (salt glazed ware, AC or reinforcement concrete) set in cement mortar all as specified and directed.
Supply & Fixing factory made SFRC manhole / drain cover (Grade M-25) heavy duty cover slab in rectangular shape of size as required, 80 mm thick including MS sheet 2 mm thick and 80 mm wide all around the cover including demolition of old manhole cover slab complete all as specified and directed.
Providing and fixing factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm),Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware[Touch Lock of zinc alloyed (white powder coated),steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured lor payment purpose.) (A) Area not exceeding 2 sqmm each.
Taking down carefully copper/aluminium point wiring light, fan, light fittings, socket or power complete, such as switches, ceiling roses, pendents, regulators, sockets etc. removing materials to store for keeping in safe custudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc. complete all as specified and directed.by Engineer-in-Charge.
Material & Labour for point wiring with single core PVC insulated unsheathed 1100 volt grade cable with multi strand copper conductor of size 1.5 Sq mm FRLS (Nominal area) drawn through and including non metallic rigid PVC concealed conduit, medium grade, ISI marked not less than 20mm dia, concealed in wall, ceiling with GI saddles GI screws, rawl plugs (concealed conduit wiring) with all fittings including Tee, Junction boxes and provision of pressed steel terminal box powder coated of suitable size for mounting switch sockets and regulators and drawing continuous earth wire of PVC insulated unsheathed 1100 Volts grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) complete all as specified. Note: (a) Cost for cutting, chasing and making good to existing surfaces are deemed to be included in the Quoted Rate.(b)one circuit with max 8 light points,the size of circuit wire shall be 1.5 sqmm
For one light point controlled by one SP switch
For one fan/exhaust fan controlled by one SP switch.
All as per item No 113 here-in-before but for one 3 pin socket out let, 6 Amps on same board with the cable 1.5 Sqmm size. Note: (a) one circuit with max 8 light points (not more than 2x 6 A socket in one circuit), the size of circuit wire shall be 2.5 sqmm.
All as per item No 113 here-in-before but for one 3 pin socket out let, 6 Amps on Independent board with the cable 1.5 Sqmm size. Note: (a) one circuit with max 8 light points (not more than 2x 6 A socket in one circuit), the size of circuit wire shall be 2.5 sqmm (d) socket outlet 6 amp only , one circuit with max 4 points with 2.5 sqmm circuit wire, otherwise only one point in each circuit with 1.5 sqmm wire.
All as per item No 113 here-in-before but with 2.5 Sq mm cable for Independent board one 3 pin 15 Amps socket outlet including 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR LS cable for continuous earth wire connected to gang box of required size all as specified and directed by Engineer-in-Charge. Note: (a) only one point in each circuit.
All as per item No 113 here-in-before but with 4 Sq mm cable for Independent board one 3 pin 15 Amps socket outlet including 4 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR LS cable for continuous earth wire required size all as specified and directed by Engineer-in-Charge. Note: (a) only one point in each circuit.
Supply & Fixing switch piano 5 amps flush type single pole one way suitable for 240 volt AC complete all as specified and directed.by Engineer-in-Charge.
Supply & Fixing socket outlet flush type 5 pin 6 amps suitable for 240 volt AC complete all as specified and directed.by Engineer-in-Charge.
Supply & Fixing switch piano 16 amps flush type single pole one way suitable for 240 volt AC complete all as specified and directed.by Engineer-in-Charge.
Supply & Fixing socket outlet 2 in 1, 5 pin 16 amps flush type suitable for 240 volt AC complete all as specified and directed.by Engineer-in-Charge.
Supply and Fixing electronic Fan Regulator rotary flush step type 120 watt, 240 volt complete all as specified and directed.
Supply and fixing of ceiling roses, surface bakelite 65x50mm 2 or 3 terminals , PVC/Polycarbonate, isolated body fixed on PVC round block complete all as specified and directed.
Supply and fixing in replacement wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver, 20 watt LED fitting, 4000K , 230 Volts, diffused optics ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed.by the Engineer- In- Charge.
Supply and fixing in replacement wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver ,10 watt LED fitting with 100 lumen/watt, 6000K , 230 Volts, diffused optics ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed.by the Engineer- In- Charge.
Supply and fixing in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up driver with flexible copper conductor cases of suitable size complete.
Supply and fixing in replacement of sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 20 amps complete all as specified and directed.by Engr-In-Charge.
Supply,installation,testing and commissioning of 1200 mm sweep BEE 5 star rated, ceiling fan with Brushless Direct Current Motor, Class of insulation:B, power factor not less than 0.9, service value (CMM/W) minimum 6.85, Airdelivery not less than 230 CMM, 350 RPM (tolerance as per IS:374-2019), THD less than 10%, including remote control unit, temperature rise=75 degree C (maximum), insulation resistance more than 2 mega ohm, suitable for 230V, 50 hz, single phase AC supply complete all as specified and directed.by Engr-In-Charge.
Supply and fixing of exhaust fan ,metal body AC single phase,230v , of size 300mm sweep with blades frame and louver complete as specified and directed by Engr-In-Charge.
Supply and fixing of electric water heater storage type steel body with copper inner tank and heating element upto 2KW capacity 25 litre,BEE5 star rated complete with all accessories such as safety valve, thermostat, NRV connection pipe etc complete as specified and directed by Engr-In-Charge.
Supply and fixing in repair LED security light fitting 35 watt, 230 V high pressure dia cast aluminium housing and secondary optical lens for superior light distribution , heat resistant toughened glass with frame, IP66 protection complete with lamp & connected item and connection with suitable cable from ceiling rose to light fitting and fixing on GI bracket made out of suitable GI Pipe medium grade 1.2 mtr long bent to shape and fixed on wall with flat iron clamps, nuts bolts washer etc all as specified and directed
Taking down including disconnecting the electric connection of ceiling fan and dismantling blades, greasing complete all as specified and directed.
Hanging / fixing only ceiling fan received from item No 132 here-in-before and connecting up including fastener and provision of suitable size of copper cable from connector of fans to ceiling rose complete.
Taking down including disconnecting the electric connection of exhaust fan and dismantling blades, greasing and painting the whole assembly including marking MES No complete all as specified and directed.
Fixing only Exhaust fan received from item No 134 here-in-before and connecting up including fastner and provision of suitable size of copper cable from connector of fans to ceiling rose complete.
M & L for submain wiring with two run of 10 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 10 sqmm PVC insulated but unsheathed FRLS cable for earth continuity conductor drawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all accessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified. Note: 3 Runs of 10 Sqmm single core and one run of 20mm conduit included.
Taking down unserviceable submain wiring two runs of any size cable including batten/conduit complete etc and making good disturbed surfaces complete all as specified and directed.
Supply and fixing load line vertical distribution board 'A' frame made out of CRCA sheet, double door, surface mounting TPN 6 way 415 volts 200 Amps rated bus bar and stove enamels dust and vermin proof suitable for TP/FP 'A' frame MCCB of 125 Amps =01 No MCCB for outgoing complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid separately.
Supply and fixing load line vertical distribution board 'A' frame made out of CRCA sheet, double door, surface mounting TPN 4 way 415 volts 200 Amps rated bus bar and stove enamels dust and vermin proof suitable for TP/FP 'A' frame MCCB of 125Amps =01 No MCCB for outgoing complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid separately.
Supply and fixing TPN distribution board made out of CRCA sheet ,double door, surface mounting TPN 4 way 415 volts 200 Amps rated bus bar and stove enamels dust and vermin proof suitable for TP/FP MCB of 63 Amps =03 No MCB for outgoing complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid separately.
Taking down old unsv MCB DB of any size complete all as specified and directed.
Material & Labour for earthing complete with GI earth plate electrode 60cmx60cmx6.00mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to and including galvanized iron wire 4 mm dia as earth lead by means of GI bolts, nuts, check nuts and washers earth pit surrounded by picked layer of coal dust and 15 mm thick mixture in equal ratio of magnesium sulphate & copper sulphate in all around bottom and top and watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plate NO 5 of SSR Part I (1991) and connecting to earthing test point, including CI cover, frame and PCC (1:3:6) type C-2 using 20mm graded stone aggregate as in earthing pit with CI cover and framing including necessary earth work etc, complete all as specified Note :- PCC chamber shall be constructed at least one meter away from building shall be provided in slanting manner. Note :- PCC pit cover shall be precast of RCC 1:2:4 type B-I 80 mm thick reinforced with XPM weighting not less than 4 Kg (sqm in liew of CI)
Material & Labour in replacement of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4 mm dia galvanized iron or steel wire complete all as specified and directed.by Engineer-in-Charge.
Supply and fix in replacement of fixed thermal and fixed magnetic settings, 4 pole MCCB 125 Amps,Ics=100% Icu50 HZ, 415 volts with rupturing capacity 16 KA complete all as specified and directed.by Engineer-in-charge.
Taking down unserviceable MCBs of any capacities from the MCCB DBs /MCB DBs after disconnecting the electric supply, complete all as specified and directed.
Supply & Fixing MCB SP 6 to 32 Amps 10 KA, 240 volt 'B' Series all as specified and directed by engineer-in-charge.
Supply & Fixing MCB SP 40 Amps 10 KA, 240 volt 'B' Series all as specified and directed by engineer-in-charge.
Supply & Fixing MCB TPN 100 Amps 10 KA, 415 volt 'B' Series all as specified and directed by engineer-in-charge.
Supply & Fixing MCB TP 63 Amps 10 KA, 415 volt 'B' Series all as specified and directed.
Supply & Fixing MCB SPN 40 Amps 10 KA, 240 volt 50 HZ 'B' Series all as specified and directed by engineer-in-charge.
Supply & Fixing MCB TPN 16 to 32 Amps 10 KA, 415 volt 50 HZ 'B' Series all as specified and directed by engineer-in-charge.
Supply & Fixing MCB metal enclosure for SPN MCB ,2 module all as specified and directed by engineer-in-charge.
Supply & Fixing MCB metal enclosure for TPN MCB ,4 module all as specified and directed by engineer-in-charge.
Supply & Fixing energy efficient post top light 15 Watt New generation, post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source including all necessary wiring LED bulb , clamps, nut and bolts mounting accessories etc all as specified and directed.
Material and labour for taking down existing pole from site and keeping in safe custody for taking of shcedule of credit complete all as specified and directed.
Material and labour for taking down existing bollard light fitting from site and keeping in safe custody for taking of shcedule of credit complete all as specified and directed.
Supply & Fixing energy efficient cast emblisment LED bollard light 9 watt,240 volts fitting with cast aluminium lighting fixture, cast aluminium column, acrylic diffuser, stainless steel screws and corrosion & UV ray resistant coating complete all as specifed and as directed. Note: Fixture includes LED light fitting , clamps, nut and bolts etc mounting accessories and excavation/earth work in any type of soil, PCC foundation etc deemed to be included in quoted rate.
Supply and erect of decoratove MS pole of 5 m height with PU coating, cast aluminium emblishments, cast aluminium lighting fixture, stainless steel screws , corrosion & UV ray resistant coating complete and with bottom 139mm OD and top OD 60mm with attached base plate 200mmx200mmx8mm with M16 x450mmx4nos MS foundation bolts with 50W LED post top light made of cast aluminium housing and glass diffuser ,corrosion & UV ray resistant coating complete all as specified and directed. Pole should have window plasma cut and duly chamfered window of for terminal connections and mounting accessories. window cover is fitted with allen screws to the pole and fixed on PCC 1:2:4 type B1 (20mm graded aggregate) complete all as specified and directed. Note: excavation/earth work in any type of soil, PCC foundation etc deemed to be included in quoted rate.
Supply, laying joint testing and commissioning of LT cable, XLPE insulated, screened, PVC bedded, galvanized steel wire armoured, heavy duty 1100 volts grade with solid aluminum conductor of size 6 sqm 2 core including necessary end connections, lugs, glands etc as per site requirement as specified and directed by engineer-in-charge
Supply, laying joint testing and commissioning of LT cable, XLPE insulated, screened, PVC bedded, galvanized steel wire armoured, heavy duty 1100 volts grade with stranded aluminum conductor of size 10 sqm 2 core including necessary end connections, lugs, glands etc as per site requirement as specified and directed by engineer-in-charge.
Supply, laying joint testing and commissioning of LT cable, XLPE insulated, screened, PVC bedded, galvanized steel wire armoured, heavy duty 1100 volts grade with stranded aluminum conductor of size 16 sqm 4 core including necessary end connections, lugs, glands etc as per site requirement as specified and directed by engineer-in-charge
Supply, laying joint testing and commissioning of LT cable, XLPE insulated, screened, PVC bedded, galvanized steel wire armoured, heavy duty 1100 volts grade with stranded aluminum conductor of size 70 sqmm 3.5 core including necessary end connections, lugs, glands etc as per site requirement as specified and directed by engineer-in-charge
Supply, laying joint testing and commissioning of LT cable, XLPE insulated, screened, PVC bedded, galvanized steel wire armoured, heavy duty 1100 volts grade with stranded aluminum conductor of size 50 sqmm 3.5 core including necessary end connections, lugs, glands etc as per site requirement as specified and directed by engineer-in-charge
Supply, laying joint testing and commissioning of LT cable, XLPE insulated, screened, PVC bedded, galvanized steel wire armoured, heavy duty 1100 volts grade with stranded aluminum conductor of size 120 sqmm 3.5 core including necessary end connections, lugs, glands etc as per site requirement as specified and directed by engineer-in-charge
Material & Labour for taking down existing LT cable from panel to to various bldg of any size and keep in safe custody for sch of credit including making good the disturbed surface of road/path hard standing etc using suitable material complete all as specified and directed.
Material and labour for sand cushioning with dry river sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming complete all as specified and directed.
Supply and laying well burnt sub class ‘B’ bricks old size as mechanical protection to under ground cables laying across the cable complete all as directed by engineer-in-charge.
Removing excavated material n exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
Supply and laying GI tube light grade as in cable protection pipe including all fittings for the size 50mm dia bore complete all as specified and directed.
Supply, install, connect, test and commissioning, 3-ph 4-wire 50hz, 433 volts, outdoor LT main distribution panel cubical type, factory made powder coated dust and vermin proof ,double door made out of 3.15 mm thick SS 304 sheet mounted on mild steel angle iron with water proof top canopy, front and back door operated with suitable locking arrangement, sheet steel encloser, cable entry detachable bottom plates erected on and including PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) pedestals finished with degree of protection IP 54 with danger notice plate complete with internal connection wiring and including the following:- Note: Cable gland, LT end terminal, all the MCCB etc must be in vertical position etc (a) Aluminum bus bars fixed on epoxy bus bar insulator capacity 320 Amps 1 Set (3 phase and one natural). (b) MCCB 250 Amps TPN 25 KA-1 NO, ICS=100%ICU (in coming). (c) MCCB 100 Amps TPN 25 KA-4 No, ICS=100%ICU (Out going). (d) Analog type volt meter - 01 Set. (e) Analog type ammeter -01 Set. (f) LED type indicator lamp set of red , yellow and blue - set 01.
Dismantling of existing electrical cable connections and taking down existing panel from location and keep in safe custody for sch of credit including making good the disturbed surface of road/path hard standing etc using suitable material complete all as specified and directed.
Material & Labour for earthing complete with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 M below ground level) with top edge of earth plate not less than 1.5 M below ground level connected to GI strip 25x4mm as earth lead by means of nuts, bolts, thimbles, check nuts, washers of GI or steel, including PCC, concrete chamber shall be PCC 1:3:6 type C-1 (using 20mm graded stone aggregate), with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in cement mortar 1:4, funnel with wire gauge mesh, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) reinforced with XPM, jalli charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified or indicated including provision of GI strip protected by 40 mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, including all excavation and earth work & connecting the earthing to an earthing test point complete, all as specified and directed by Engineer-in-Charge.
Material & Labour for Dismantling of split type AC of any make & model and refixing the AC with gitties/fasteners, cutting wall/concrete incl arrangement of required T&P, laying of extra insulated copper tubing, positioning of condensing unit and stand, fixing of extra PVC flexible multistranded copper conductor of size 2.5 sq mm and brazing work, leak check, dehydration and topping up of refrigerant gas upto recommended level, connection of drain pipe, making good the disturbed surface including PCC and brick work and testing the unit for satisfactory functioning complete all as specified and directed.
Material and labour for making opening in wall for fixing the exhaust fan of size 300mm and making good of disturbed surface smooth and fair finish complete all as specified and directed.
Atish Builders LLP (BID ID -3357315)
M/s. Kansal Construction Co. (BID ID -3358158)
GLIBS CONSTRUCTION (BID ID -3358235)
Ashish Sehgal and Co. (BID ID -3366576)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .