Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.2 LAccepted-AOC | ₹39.2 L Quoted ₹39.8 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹42.0 L+₹2.2 L (5.65%)Rejected-Finance | ₹42.0 L+₹2.2 L (5.65%) | L2 | Rejected-Finance NOT ADMITTED BEING L2 |
| 3 | L3₹43.8 L+₹4.1 L (10.2%)Rejected-Finance 702 A1 SHREE PRASAD TAWADEWADI SHREE DATTAGURU PARK KUMBHARWADA URAN DIST RAIGAD MAHARASHTRA 400 702 | URAN | RAIGAD | MAHARASHTRA | 400702 | ₹43.8 L+₹4.1 L (10.2%) | L3 | Rejected-Finance NOT ADMITTED BEING L3 |
| 4 | L4₹44.4 L+₹4.7 L (11.7%)Rejected-Finance 1501 BHAGWATI EMINENCE SAVITRIBAI PHULE MARG BESIDES R R PATIL GARDEN SECTION 13 NERUL E NAVI MUMBAI | RAIGAD | MAHARASHTRA | 400702 | ₹44.4 L+₹4.7 L (11.7%) | L4 | Rejected-Finance NOT ADMITTED BEING L4 |
| 5 | L5₹44.7 L+₹4.9 L (12.4%)Rejected-Finance FLAT NO 201 GREEN VALLEY CHS PLOT NO 26 SECTOR 19 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | ₹44.7 L+₹4.9 L (12.4%) | L5 | Rejected-Finance NOT ADMITTED BEING L5 |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
13 Sept 2024, 6:00 pmClosed
GE NW KARANJA
NAVAL STATION KARANJA, URAN, RAIGAD, MAHARASHTRA
REPAIR REPLACEMENT OF INTERNAL WIRING FITTING FIXTURE CONTROL PANEL LED LIGHT FITTING MCCB LT PANEL BOARD SUBMAIN AND OTHER MISC WORKS AT ADM/TECH AREA AT NAVAL STATION KARANJA
2024_MES_667335_1
8965/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE NW KARANJA
D and above b i
8 documents required · 8 mandatory
₹500
Yes
GE NW KARANJA
₹94,000
Yes
5 Nov 2024
22 Jul 2024
16 Sept 2024
22 Jul 2024
13 Sept 2024
5 Aug 2024
Amount
Notes : (i) The work consists of 02 jobs as under:- JOB (A) : TPP 2024-2025 Ser No. 58 (ii) Please refer schedule 'A' notes before quoting the tender. (iii) Amount of Schedule of Credit shall be deducted off line by the department. ITEMS FOR JOB 'A'
Taking down carefully copper /aluminium point wiring (light, fan socket or power) through stove enamelled steel conduit/pvc conduits including complete fittings such as switches, ceiling roses, pendants, regulators, sockets,, switch sockets, electrical fittings etc removing and making good disturbed surfaces of walls/ceiling etc, complete all as specified and directed.
M&L for concealed point wiring with 1 5 Sqmm single core, multi stranded copper conductor 1100 V grade, PVC insulated unsheathed cable (with approved colour code) FRLSH cable in CONCEALED PVC ISI marked conduits by cutting chases & making good of the existing surface including all accessories as approved, with PVC 1.5 mm multi stranded insulated unsheathed FRLSH copper wire, of green colour for continous earth, including sunken box made out of suitable thickness and not less than 60 mm in depth Gl/MS/ pressed steel terminal box to be concealed in wall, duly painted including laminated hylum/maonite sheet cover thickness 3mm for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washer complete all as specified and directed. One light /fan/ call bell point controlled by one switch Note: Wiring to be done as per arroved colour code,
All as per BOQ Serial item No 1.02 above but one 5 pin socket outlet 5 Amps on independent board
All as per BOQ Serial item No 1.02 above but one 5 pin socket outlet 5 Amps on same board
All as per BOQ Serial item No 1.02 above but one light point controlled by 2 way switch SP, 5 Amp, 240 Volts
All as per BOQ Serial item No 1.02 above but with 2.5 sqmm multi stranded copper conductor 1100 volts grade FRLS PVC insulated sheathed cable with FRLS PVC 1.5 Sqmm multi standard insulated unsheathed copper wire for continues earth on independent board complete all as specified and dirrected.
M&L for point wiring with 1.5 Sqmm single core, multi stranded copper conductor 1100 V grade, ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLSH cable drawn in ISI marked casing caping of 25 mm wide, with double locking type, including all accessories as approved, with PVC 1.5 mm multi stranded insulated unsheathed FRLSH copper wire, of green colour for continous earth, including sunken box made out of suitable thickness and not less than 60 mm in depth GI/MS/ prssed steel terminal box to be conclead in wall, duly painted including 3mm hylum /masonite sheet cover, for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washer complete all as specified and directed. One light / fan / call belkl point controlled by one switch. Note : Wiring to be done as per arroved colour code.
All as per BOQ Serial item No 1.07 above but one light point controlled by 2 way switch SP, 5 Amp, 240 Volts
All as per BOQ Serial item No 1.07 above but one 5 amp socket point on same board
All as per BOQ Serial item No 1.07 above but one 5 amp multi socket on indepenedent board.
All as per BOQ Serial item No 1.07 above but using 2.5 sqmm ( nominal area) multistranded FRLS copper conductor cable/wire & 2.5 sqmm size PVC insulated unsheathed copper conductor cable for earth continuity ( green colour) for one 5 pin socket outlet 5 / 15 Amp multi purpose independent point controlled by 15 Amp switch, SP one way, 240 Volts & Socket, complete all as specified and directed.
All as per BOQ Serial item No 1.07 above but using 4 sqmm (nominal area) multistranded copper conductor cable/wire for one 5/15 Amp socket point controlled by 15 Amp switch, SP one way 240 Volts & Socket, complete all as specified and directed.
M&L for Point wiring with PVC insulated unsheathed electric cable 1100 volts grade, single core,FRLSH cable having multistranded copper conductor of 1.5 Sqmm nominal cross sectional area, drawn in existing concealed conduit with 1.5 Sqmm green PVC insulated unsheathed multistranded copper conductor FRLSH cable, ISI marked as continuous earth conductor connected to earth dolly by providing suitable lugs including 3.0 mm new laminated hylum sheet /masonite sheet cover of suitable sizes to be fixed/ mounting on existing MS/ GI sunkun boxes for mounting of fittings like switches, sockets, fan regulators etc fixed with galvanised screw and cup washer. complete all as specified and directed. One light / call bell point controlled by one switch Note : Wiring to be done as per arroved colour code.
All as per BOQ Serial item No 1.13 above but one fan/exhaust fan point controlled by one switch
All as per BOQ Serial item No 1.13 above but one 5 pin socket outlet 5 Amps on same board
All as per BOQ Serial item No 1.13 above but one 5 pin socket outlet 5 Amps on independent board
All as per BOQ Serial item No 1.13 above but one light point controlled by 2 way switch SP, 5 Amp, 240 Volts
All as per BOQ Serial item No 1.13 above but with 2.5 sqmm multi stranded copper conductor 1100 volts grade FRLSH PVC insulated sheathed cable with FRLSH PVC 2.5 Sqmm multi standard insulated unsheathed copper wire for continues earth on independent board complete all as specified and directed.
S&F switch piano flush button single pole one way, 6 Amp (ISI marked) complete all as specified and directed. Note : This item shall also be used as in repairs of existing 6 Amp switch.
S&F Switch socket outlet 2 in 1, 3 pin, 6 Amp flush type (ISI marked) complete all as specified and directed. Note : This item shall also be used as in repairs of existing 6 Amp switch socket outlet.
S&F Socket outlet 2 in 1, 3 pin, 6 Amp flush type (ISI marked) complete all as specified and directed Note : This item shall also be used as in repairs of existing 6 Amp socket outlet.
S&F Switch bell push flush type 5 Amp (ISI marked) all as per complete all as specified and directed. Note : This item shall also be used as in repairs of existing 5 Amp switch bell.
S&F Switch socket outlet 15 Amp, 5-in-1, controlled by one switch (ISI marked) complete all as specified and directed Note : This item shall also be used as in repairs of existing 6 Amp socket outlet.
S&F Switch flush button, single pole two way, 6 Amp (ISI marked) complete all as specified and directed Note : This item shall also be used as in repairs of existing 6 Amp two way switch.
S&F Socket type EME fan 5 step regulator for ceiling fan of suitable size, complete all as specified and directed. Note : This item shall also be used as in repairs of existing fan regulator.
S&F Lamp holder/angle holder insulated body with black/white plate for batten fittings. Note : This item shall also be used as in repairs of existing lamp holder.
S&F modular step type fan regulator ISI 120W,AC,50Hz complete all as specified and directed. Note : This item shall also be used as in repairs.
S&F modular switch 1 module 6 amp one way complete all as specified and directed. Note : This item shall also be used as in repairs.
S&F modular switch 1 module 16 amp one way complete all as specified and directed. Note : This item shall also be used as in repairs..
S&F modular socket 2 module universal type 5/6 amp one way complete all as specified and directed. Note : This item shall also be used as in repairs.
S&F modular socket 2 module universal type 15/16 amp one way complete all as specified and directed. Note : This item shall also be used as in repairs..
S&F modular bell push 6A 1 module complete all as specified and directed complete all as specified and directed. Note : This item shall also be used as in repairs.
S&F Bell buzzer, ding dong 230v 50hz single pole complete all as specified and directed. Note : This item shall also be used as in repairs.
S&F modular cover plates with frame up 1 /2 module as per site requirements apart from the rates included in the point wiring for cover plates and metal flush boxes which is catered for new point wiring complete all as specified and directed . NOTE-cover plates considered in this item only for the maintanance of switches of existing modular fitting qtrs
S&Fmodular cover plates with frame up 3 module as per site requirements apart from the rates included in the point wiring for cover plates and metal flush boxes which is catered for new point wiring complete all as specified and directed. NOTE-cover plates considered in this item only for the maintanance of switches of existing modular fitting qtrs
S&F modular cover plates with frame up 4 module as per site requirements apart from the rates included in the point wiring for cover plates and metal flush boxes which is catered for new point wiring complete all as specified and directed. NOTE-cover plates considered in this item only for the maintanance of switches of existing modular fitting qtrs
S&F modular cover plates with frame up 6 module as per site requirements apart from the rates included in the point wiring for cover plates and metal flush boxes which is catered for new point wiring complete all as specified and directed. NOTE-cover plates considered in this item only for the maintanance of switches of existing modular fitting qtrs
S&F modular cover plates with frame 8 module as per site requirements apart from the rates included in the point wiring for cover plates and metal flush boxes which is catered for new point wiring complete all as specified and directed. NOTE-cover plates considered in this item only for the maintanance of switches of existing modular fitting qtrs
S&F modular cover plates with frame 12 module as per site requirements apart from the rates included in the point wiring for cover plates and metal flush boxes which is catered for new point wiring complete all as specified and directed NOTE-cover plates considered in this item only for the maintanance of switches of existing modular fitting qtrs
S&F modular metal flush box as per site requirements 1/2 modules complete all as specified and directed. NOTE-metal flush boxes considered in this item only for the maintanance of switches of existing modular fitting qtrs
S&F modular metal flush box as per site requirements 4 modules complete all as specified and directed. NOTE-metal flush boxes considered in this item only for the maintanance of switches of existing modular fitting qtrs
S&Fmodular metal flush box as per site requirements 6 modules complete all as specified and directed. NOTE-metal flush boxes considered in this item only for the maintanance of switches of existing modular fitting qtrs
S&F modular metal flush box as per site requirements 8 modules complete all as specified and directed. NOTE-metal flush boxes considered in this item only for the maintanance of switches of existing modular fitting qtrs
S&F modular metal flush box as per site requirements 12 modules complete all as specified and directed. NOTE-metal flush boxes considered in this item only for the maintanance of switches of existing modular fitting qtrs
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 4.0 Sqmm (with colour code), drawn in but including non metallic rigid PVC conduit of 25mm dia/casing capping , ISI marked including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 4.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surfaces/ recess complete all as specified and directed. Note :- 2 runs of 4.00 Sqmm, 1 run of 4.00 Sqmm earth wire & one run of PVC conduit shall be considered as 1RM.
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLS cable of 6.0 Sqmm (with colour code), drawn in but including non metallic rigid PVC conduit of 25mm dia/casing capping, ISI marked including one run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 6.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surface/ recess complete all as specified and directed. Note :- 2 runs of 6.00 Sqmm, 1 run of 6.00 Sqmm earth wire & one run of PVC conduit shall be considered as 1RM
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 10.0 Sqmm (with colour code), drawn in but including non metallic rigid PVC conduit of 25mm dia/casing capping, ISI marked including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 10.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surface/ recess complete all as specified and directed. Note :- 2 runs of 10.00 Sqmm, 1 run of 10.00 Sqmm earth wire & one run of PVC conduit shall be considered as 1RM
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLS cable of 4.0 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping, including one run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 4.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in complete all as specified and directed. Note :- 2 runs of 4.00 Sqmm, 1 run of 4.00 Sqmm earth wire & one run of PVC conduit shall be considered as 1RM
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 6.0 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping, including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 6.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in complete all as specified and directed Note :- 2 runs of 6.00 Sqmm, 1 run of 6.00 Sqmm earth wire & one run of PVC conduit shall be considered as 1RM
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 10.0 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping, including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 6.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in complete all as specified and directed. Note :- 2 runs of 10.00 Sqmm, 1 run of 10.00 Sqmm earth wire & one run of PVC conduit shall be considered as 1RM
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 2.5 Sqmm (with colour code), drawn in but including non metallic rigid PVC conduit of 20mm dia/casing capping , ISI marked including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 2.5Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surfaces/ recess complete all as specified and directed. Note :- 2 runs of 2.5 Sqmm, 1 run of 2.5 Sqmm earth wire & one run of 20mm PVC conduit shall be considered as 1RM
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 2.5 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping, including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 2.5 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in complete all as specified and directed. Note :- 2 runs of 2.5 Sqmm, 1 run of 2.5 Sqmm earth wire & one run of PVC conduit shall be considered as 1RM
M&L cutting of wall/ceiling/column for laying submain of any size including making good existing surface complete all specified and directed in charge.
S&F in repairs LED building security light fitting with suitable size bracket/angle with three core flexible wire to fit security light of 45 w IP 66 protection LED 220V,AC,50HZ including GI Bracket , surge protection ,high power factor etc complete all as specified and directe.
S&F in repairs LED batten with 20/22W LED tube light (4") , 220V,AC ,50Hz in wall/surface connecting with all required accessories like PVC box base,flexible cable from ceiling rose etc,suge protection, high power factor, Surface and wall mounted LED batten, Engineering plastic batten with accessories complete all as directed and specified and directed
S&F in repairs LED batten with 24W LED tube light (4") , 220V,AC ,50Hz in wall/surface connecting with all required accessories like PVC box base,flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten with accessories complete all as specified and directed
S&F in repairs double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 200 Amps rated bus bar 12 way double door open able type complete all as specified and directed
S&F in repairs double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 200 Amps rated bus bar 8 way double door open able type complete all as specified and directed .
S&F in repairs double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 200 Amps rated bus bar 4 way type complete all as specified and directed
S&F in repairs double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 200 Amps rated bus bar 2 way type complete all as specified and directed
S&F in repairs double door MCB VTPN DB 4 WAY made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 200 Amps rated bus bar 4 way type complete all as specified and directed
S&F in repairs double door MCB TPN DB 4 WAY made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 200 Amps rated bus bar 4 way type complete all as specified and directed
S&F 6 to 32 AMP MCB single pole 240 V 10 KA (C-Series) complete all as specified and directed.
S&F 32 AMP MCB DP 240 V 10 KA (C-Series) complete all as specified and directed.
S&F in repairs LED recess/surface mounted 2"x2" luminarie 36/40w fitting, 220V,AC, 50 Hz,suge protection, high power factor complete all as specified and directed by engr-in-charge.
S&F in repairs LED Bulk head fittings 9/10W , 220V,AC, 50Hz luminaire including LED light driver holder connecting up with three core flexible copper conductor calbe of suitable size complete with all acccessories complete all as specified and directed.
S&F in repairs LED tube rod 20 watt ,220V,50Hz,AC change with existing any tube rod complete all as specified and directed
S&F in repairs Batten MS suitable for 18/22/24W LED rod with accessories including suitable 1.5 sqmm 2 core wire for connecting with ceiling rose complete all as specified and directed.
S&F in repairs LED batten 10w, 2 feet with LED tube light ,220V,50Hz,ACin wall/surface connecting with all required accessories like flexible cable from ceiling rose etctype complete all as specified and directed.
S&F in repairs MCCB 4 pole, thermal magnetic release range 100 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed
S&F in repairs MCCB 4 pole, thermal magnetic release range 125 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed
M& L for daily complaint checking & repairing of DBs/meter panel board/circuits/submain wiring/switches/sockets etc and other connected work including rectification of faults complete all as specified and directed
S&F in repairs MCCB 4 pole, thermal magnetic release range 63 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed
S&F in repairs MCCB 4 pole, thermal magnetic release range 40 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed
Taking out cover plate of bus conductor duct of multi-storied building,inspection cleaning, servicing including replacement of rusted nuts bolts,insulators etc ,cutting of damage end of outgoing cables and reconnection using proper size of cable lugs and preparation of old painted surface by scrapping and brooming down and material and labour for two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F in repairs three pin top of capacity 15 amp ,AC,220V all specified and directed
S&F in repairs PCRD plug of capacity 15 amp ,AC,220V all specified and directed
S& Fin repairs epoxy coated connector of capacity 100A post type for bus bar trunking system complete all as specified and directed.
Taking out two wire from meter / bus bar/MCB SPN/SP with keeping in veiw safety and replaced with 2 run of 6 sqmm wire of meter with suitable size of cable lugs both end and reconnection with meter and bus bar/MCB SPN/SP complete all as specified and directed. NOTE : Rate of lugs will deemed to be included in quoted rate by the contractor.
S & F in repairs sunken/terminal box of size 10x10cm, cocealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls complete all as specified and directed.
S & F in repairs sunken/terminal box of size 15x7.5cm, cocealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls complete all as specified and directed.
S&F in repairs sunken/terminal box of size 20x15cm, cocealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls complete all as specified and directed.
S&F in repairs sunken/terminal box of size 20x25cm, concealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls complete all as specified and directed.
S&F in repairs emergency bulb LED 10W, 230V, 50Hz, with 4 hour backup complete all as specified and directed.
S&F in repairs round/square type, recessed /surface 12W/14W warm /white LED downlight dimmable with high lumen 230V, compatible with Dimmer as per sample complete all as specified and directed.
S&F in repairs RCCBs 63 Amps double pole 100mA breaking capacity complete all as specified and directed.
S&F in repairs RCCBs 40 Amps double pole 100mA breaking capacity complete all as specified and directed.
S&F in repairs decorative light suitable for holder B-22/E-27 ,220V,50Hz,AC including flexible wire and connected accessories all specified and directed
M&L taking out and refixing of tube light,mirror light etc after cleaning and any type rectifiying defect complete all specified and directed
S&F in repairs LED batten with 20W LED tube light (four feet) with sensor in wall/surface connecting with all required accessories like PVC box base,flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten with accessories complete all as specified and directed.
S&F LED batten with 9/10 W LED tube light two feet mirror type with sensor in wall/surface connecting with all required accessories like PVC box base,flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten with accessories complete all as specified and directed.
S&F LED batten with 20W LED tube light (four feet) with inverter type with 2 hrs backup in wall/surface connecting with all required accessories like PVC box base,flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten with accessories complete all as specified and directed.
S&F in repairs LED bulb of 9/10 watt ,220V,AC,50 Hz complete all as specified and directed.
M&L for servecing and cleaning of geyser of any capacity including taking out from existing position and refixing all complete all as specified and directed.
M&L for checking ceiling fan of size 1200/1400mm and change defective part cotter pin/ nut bolt etc including taking down and refixing complete all as specified and directed.
S&F in repairs fan rod of size 1/1.5 feet suitable for mounting ceiling fan of size 1200/1400 mm complete all as specified and directed.
S&F in repairs capacitor of 2.5 mfd complete all as specified and directed.
S&F in repairs capacitor of 4.0 mfd complete all as specified and directed.
M&L for rewinding of ceiling fan 1200/1400mm using suitable copper winding wire complete all as specified and directed.
Taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets and regulators, etc. for reuse at site or carrying to the store/ take in soc complete all as specified and directed.
S&F in repairs LED high bay light of 100Watt including flexible wire and all connected accessories including taking down complete all as specified and directed.
S&F in repairs LED batten with 20/22W LED tube light box type with hanging arrangement in wall/surface/ceiling connecting with all required accessories like PVC box base,flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten with accessories complete all as specified and directed.
M&L flexible wire for connection fan/light/etc of size 1 sqmm X2 core including taking down old wire all specified and dirceted in charge.
Dismantling of existing panel including disconnecting connected cables, etc. and Supply, Installed, Testing and Commissioning cubical type LT Panel floor mounted INDOOR type for 415V, 3 phase 4 wire sysytem 50 Hz AC supply, factory made fabricated from MS sheet totally enclosed, dust weather proof and vermin proof for outer shell having TPN aluminium bus bar rating 1.5 times that of controlling MCCB supported on bottom base channel MS section not less than 100mm x 50mm x 5 mm thick, entire panel shall have a common aluminium earth bar of size 25mm x 5mm at the rear with 2 Nos earth stud, solid connection from main bus bar to switchgears with required size of copper wiring with minimum 2.5 Sqmm PVC insulated copper conductor cable , cable alleys, cable gland plates in two half and general construction confirming to IS-8623/93 and wall/floor mounted on suitable PCC foundation with follwoing detailed specification & control complete all as specified and directed with the following accessories :-
OUTER SHELL :- The outer shell shall be made of 2.00 mm thick CRCA body & MS angle section 50x50x6 mm frame with front & back openable, single door system lockable/ openable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate ahing provision for entry of armoured cable of adequite size of glands. The dimension of the outer shell shall be adequite to accommdodate inner shell described below 50 mm space all around and shall be fabricated in such a way that the complet inner shell alongiwth its control gears/MCCB and accessories should be taken outside without disturbing outer sheel. The outer shell shall be mounted on a zinc metal coated stand. Provision of threaded earthing studs at bottom and lifting lugs of suitable size at top to lift the feeder pillar box safely shall be made. Computer cut self adhesive vinly danger notice plate having conventional symbol of bone and skull shall be provided. The degree of protection of outer shell shall be IP-65.
INNER SHELL :- Inner shall made of 2.0 mm thick CRCA body compartmentalized for each control gear, front openable single door system lockable/openable by keys from both sides having chromium plated fancy locks (2 Nos in each compartment) ahving louvers and air vents gasket for natural flow of air "U' type gasket shall be used to make the inner shell completely vermin proof and to accomodate incomer/outgoing MCCB's and TPN aluminium bus bar and extension links of rating not less than the 1.5 times rated capacity of the respective MCCB's. The TPN bus bar and exension links shall be insulated with colour coaded heat, shrikable sleeve and shall be mmounted on suitable size 'F' class through out the length of the TPN bus bar. Computer cut self adhesive vinyl danger notice plate having conventional symbol of bone and skull shall be provoid on bus bar chamber. All control wires shall be with not less than 2.5 Sqmm multistranded copper conductor and shall be properly bunched. tied, ferruled for proper identification and crimped with adequite size of lugs. The cubical shall have a bottom channel of size 75x50mm duly coated with zinc metal coating. A detachable predrilled gland plate of thickness 3.15 mm zinc metal coated should be used at the bottom, indicating lamps LED type, 230 Volt, AC at the incomer of the unit to show three phase availablity at the incomer. The degree of protection for inner shell shall be IP-42 and carrly the following control :- (A) INCOMING - (i) MCCB of 250 A, microprocessor based , 4 pole 415 volt 50 kA breaking cap. With adjustable over load,short circuit ,ground fault (4 pole) & fixed instantanous neutral protection(4 pole), conforming to IS/IEC-60947-2 including spreader terminal kit – 01 No. (B) OUTGOING - (a) MCCB of 63 A, microprocessor based , 3 pole 415 volt 35 kA breaking cap. With adjustable over load,short circuit ,ground fault & fixed instantanous neutral protection, conforming to IS/IEC-60947-2 including spreader terminal kit -05 Nos(4 W + 1 spare ) (b)Digital type Voltmeter three phase class 0.5, 96X 96 mm flush mounted case with adeqaute CT arrangemnt (c)Digital type Ammeter three phase class 0.5, 96X 96 mm flush mounted case with adeqaute CT arrangemnt (d) LED INDICATORS RIBBED LENS WITH TRIMMED COLLAR - Red, Yellow and Blue - 1 Each, (e) Aluminium bus bar of Rating 300 Amp R-Y-B phases and Neutral. (f) Base frame for cubical mounting made out of suitable size equal angle iron duly painted. (g) Foundation for the panel should provided with PCC 1:4:6 at a depth of 150 MM below G.L. and 100 MM above the G.L. with slot openings for I/C and O/G cables.
S&F in repairs modular AC box with mcb spn 20 Amp including inner, outer and metal flush box complete all as specified and directed.
S&F in repairs two way sheet metal enclosure with three pin socket and plug top and 20 amp single pole MCB complete all as specified and directed .
S&F in repairs socket outlet 15 Amp, 5-in-1, controlled by one switch (ISI marked) complete all as specified and directed.
S & F Switch 15 Amp, 5-in-1, controlled by one switch (ISI marked) complete all as specified and directed.
R A Electric Co. (BID ID -3077749)
Sagar Electricals (BID ID -3080992)
SREE HARITHA ASSOCIATES (BID ID -3088534)
M.K Enterprises (BID ID -3080378)
Shri Krishna Trading Corporation (BID ID -3078970)
ELECTRO ASSOCIATES (BID ID -3082247)
BRICKS ON CLOUD INFRA (BID ID -3089751)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .