| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.9 LAccepted-Finance 1ST FLOOR BL 8 6 DR B C ROY SARANI JYANGRA BAGUIHATI KOLKATA 700059 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700059 | L1 | Accepted-Finance Quoting Lowest rate | |
| 2 | L2₹6.9 L+₹91,590 (15.4%)Rejected-Finance | L2 | Rejected-Finance Quoting Higher rate | |
| 3 | L3₹6.9 L+₹96,400 (16.2%)Rejected-Finance GR 8 ADDA BUILDING 1ST FLOOR CITY CENTRE DURGAPUR 16 | DURGAPUR | PASCHIM BARDHAMAN | WEST BENGAL | L3 | Rejected-Finance Quoting Higher rate | |
| 4 | Rejected-Technical BASUDEBPUR BELKHALI HOWRAH PIN 711 322 | HOWRAH | HOWRAH | WEST BENGAL | 711322 | - | Rejected-Technical Insufficient Documents of Supervisory part and GST Return of the respective tender |
| Sl No | Description | Qty | Unit | RIK ENTERPRISE L2 | DURGAPUR POWER L3 | M/S S. CHATTERJEE L1 |
|---|---|---|---|---|---|---|
| 1.01 | Supply, Installation,Testing & Commisioning of Micropresssor controlled Addressable Multisensor detector IP 42 ( VDS / UL /ERTL/ LPCB / FM approved ) with inbuilt optical smoke sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. The detector should have 360 degree optical view with single / multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors.
(Make : Siemens / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton or Make as approved by EIC) | 64 | Nos | 2,400 ₹1,53,600 | 2,550 ₹1,63,200 | 1,950 ₹1,24,800 Lowest |
| 2.00 | Supply, Installation,Testing & Commisioning of Addressable Manual Call Point ( VDS / UL /ERTL/ LPCB / FM approved ) with in built short circuit fault isolator as per NFPA style 7 wiring complete as required. (Make : Siemens / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton or Make as approved by EIC) | 4 | Nos | 3,300 ₹13,200 | 3,500 ₹14,000 | 3,000 ₹12,000 Lowest |
| 3.00 | Supply, Installation, Testing & Commissioning of Response
Indicator, with all other accessories. (Approved Make : Siemens / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton or Make as approved by EIC) | 32 | Nos | 360 ₹11,520 | 350 ₹11,200 | 300 ₹9,600 Lowest |
| 4.00 | Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex/Gloster/ RR Kable/Polycab ) through 19 mm dia PVC 'FR' type Rigid Conduit pipe with necessary arrangement as per G.S. (Make : Precision/ AKG/ Universal/ Polycab) on the surface of the wall. | 1,224 | Mtrs | 160 ₹1,95,840 | 155 ₹1,89,720 | 130 ₹1,59,120 Lowest |
| 5.00 | Supply, Installation, Testing & Commissioning of IP Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd) complete with inbuilt short circuit fault isolator. Degree of protection IP65 ( VDS / UL /ERTL/ LPCB / FM approved) approved. (Make : Siemens / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton or Make as approved by EIC) | 4 | Nos | 5,650 ₹22,600 | 6,000 ₹24,000 | 5,000 ₹20,000 Lowest |
| 6.00 | Supply, Installation,Testing & Commisioning of Microprocessor based Intelligent, addressable expandable and fully networkable fire alarm control panel ( VDS / UL / FM approved ) suitable for the devices as stated in the previous items of this BOQ along with 20% spare capacity with each loop loading not exceeding 80% of the full capacity of detectors and devices taken together, conplying to IS 2189:2008 or its latest amendments, and with 1/4 VGA display.The panel shall be soft addressable type and shall be able to give pin point location of all fire/ fault conditions. Further, the panel must be able to automatically switch off respective control switches whenever any alarm is triggered.The Panel should be able to store sufficient numbers of log events in its Memory as per recommended standards. a) The panel shall have in built rectifier, provision for external & internal printer ( if required ), Loop cards, L C D unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, in built Surge protection facility, integral SMF lead acid batteries with sealed cells of 24 V capable of running for 24 hours normal working and then be capable of operating the system for 30 minutes during Emergency condition, with integral battery charger complete in all respect as required. b) The FACP shall be capable of being networked ( future expansion ) with other similar FACP located at different part of the premises through single RS 485 bus.The FACP shall have provision for interfacing with the public address system, remote computer and BMS interface. The system must be preloaded with licenced software. (Make : Siemens / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton or Make as approved by EIC) | 1 | Item | 2,75,000 ₹2,75,000 | 2,72,500 ₹2,72,500 | 2,56,000 ₹2,56,000 Lowest |
| 7.00 | Making necessary drawing of total installation of Fire Detection System and to be submitted to the office as per direction of EIC. | 1 | Job | 2,500 ₹2,500 | 6,000 ₹6,000 | 2,000 ₹2,000 Lowest |
| 8.00 | Supply, Installation, Testing & Commissioning of Intelligent signal processing unit having Voltage free NO contact which would be connected in series with magnetic coil of AHU power supply unit. In case of Fire, the voltage free contact would close the circuit to isolate the power supply of AHU. (Make : Siemens / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton or Make as approved by EIC) | 2 | Nos | 2,950 ₹5,900 | 2,500 ₹5,000 Lowest | 2,600 ₹5,200 |
| 9.00 | Labour charges for dismantaling the existing fire detection system such as PVC pipe,wire,dector,device and other accessories etc. [ 4 nos. labour for 3 days] | 1 | Job | 5,650 ₹5,650 | 5,000 ₹5,000 Lowest | 5,500 ₹5,500 |
Tender Value
Refer Docs
EMD Value
₹11,550
Closing Date
25 Mar 2026, 11:00 amClosed
Sr.Superintending Engineer
Office of the Sr. Superintending Engineer, Western Electrical Circle , PWD, Purta Bhavan, 1st floor, Burdwan-713103
Dedicated Burn Unit under NPPMT BI at CBS (Female) and adjacent roof area under Project RN Ao. 25000392-Electrical Work for creation of dedicated Burn Unit at CBS (Female) and adjacent roof area of BMCH. Purba Bardhaman ---- SITC of Fire Detection
2026_WBPWD_1022905_1
WBPWD/SSEWEC /BED /NIQ-116/2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Purba bardhaman
Please refer Tender documents.
6 documents required · 6 mandatory
₹11,550
Office of the Sr. Superintending Engineer, Western
11 May 2026
14 Mar 2026
27 Mar 2026
14 Mar 2026
25 Mar 2026
19 Mar 2026
14 Mar 2026 - 19 Mar 2026
19 Mar 2026
Supply, Installation,Testing & Commisioning of Micropresssor controlled Addressable Multisensor detector IP 42 ( VDS / UL /ERTL/ LPCB / FM approved ) with inbuilt optical smoke sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. The detector should have 360 degree optical view with single / multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors. (Make : Siemens / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton or Make as approved by EIC)
Supply, Installation,Testing & Commisioning of Addressable Manual Call Point ( VDS / UL /ERTL/ LPCB / FM approved ) with in built short circuit fault isolator as per NFPA style 7 wiring complete as required. (Make : Siemens / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton or Make as approved by EIC)
Supply, Installation, Testing & Commissioning of Response Indicator, with all other accessories. (Approved Make : Siemens / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton or Make as approved by EIC)
Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex/Gloster/ RR Kable/Polycab ) through 19 mm dia PVC 'FR' type Rigid Conduit pipe with necessary arrangement as per G.S. (Make : Precision/ AKG/ Universal/ Polycab) on the surface of the wall.
Supply, Installation, Testing & Commissioning of IP Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd) complete with inbuilt short circuit fault isolator. Degree of protection IP65 ( VDS / UL /ERTL/ LPCB / FM approved) approved. (Make : Siemens / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton or Make as approved by EIC)
Supply, Installation,Testing & Commisioning of Microprocessor based Intelligent, addressable expandable and fully networkable fire alarm control panel ( VDS / UL / FM approved ) suitable for the devices as stated in the previous items of this BOQ along with 20% spare capacity with each loop loading not exceeding 80% of the full capacity of detectors and devices taken together, conplying to IS 2189:2008 or its latest amendments, and with 1/4 VGA display.The panel shall be soft addressable type and shall be able to give pin point location of all fire/ fault conditions. Further, the panel must be able to automatically switch off respective control switches whenever any alarm is triggered.The Panel should be able to store sufficient numbers of log events in its Memory as per recommended standards. a) The panel shall have in built rectifier, provision for external & internal printer ( if required ), Loop cards, L C D unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, in built Surge protection facility, integral SMF lead acid batteries with sealed cells of 24 V capable of running for 24 hours normal working and then be capable of operating the system for 30 minutes during Emergency condition, with integral battery charger complete in all respect as required. b) The FACP shall be capable of being networked ( future expansion ) with other similar FACP located at different part of the premises through single RS 485 bus.The FACP shall have provision for interfacing with the public address system, remote computer and BMS interface. The system must be preloaded with licenced software. (Make : Siemens / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton or Make as approved by EIC)
Making necessary drawing of total installation of Fire Detection System and to be submitted to the office as per direction of EIC.
Supply, Installation, Testing & Commissioning of Intelligent signal processing unit having Voltage free NO contact which would be connected in series with magnetic coil of AHU power supply unit. In case of Fire, the voltage free contact would close the circuit to isolate the power supply of AHU. (Make : Siemens / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton or Make as approved by EIC)
Labour charges for dismantaling the existing fire detection system such as PVC pipe,wire,dector,device and other accessories etc. [ 4 nos. labour for 3 days]
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 17.48 MB
MakeList.pdf
Additional Documents • 0.12 MB
BOQ_2514139.xls
BOQ • 0.28 MB
new2911.pdf
Tender Documents • 0.51 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .