Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹7.2 LAccepted-AOC ARA P O GANESHPUR DIST LATEHAR PIN 829202 | LATEHAR | JHARKHAND | 829202 | L-1 | Accepted-AOC As per recommendation of TC and Approval of competent authority | |
| 2 | L-2₹7.4 L+₹1.3 L (21.2%)Rejected-Finance RAHAM TANDWA DISTT CHATRA PIN 825321 | CHATRA | JHARKHAND | 825321 | L-2 | Rejected-Finance As per recommendation of TC and Approval of Competent authority |
Tender Value
₹7.4 L
EMD Value
₹9,225
Closing Date
22 May 2024, 6:00 pmClosed
Staff Officer (EnM),M-S Area
Office of the General Manager M-S Area Bachra, 829201.
Diversion of 11 KV JBVNL OH line with 2 X25 KVA DTR (Distribution Transformer) for mines extension near Pannatand Tola, Aara under Chamtat patch, Magadh OCP, M-S area
2024_CCL_307750_1
GM(MS)/SO(EnM)/e-NIT/24-25/16
Open Tender
Electrical and Maintenance Works
Item Rate
20 days
Office of the Project Officer M-S Area, Bachra
Please Refer NIT
4 documents required · 4 mandatory
₹9,225
26 Mar 2025
9 May 2024
24 May 2024
9 May 2024
22 May 2024
9 May 2024
9 May 2024 - 15 May 2024
Amount
Dismantling of pole/ street light standard/strut embedded in brick ballast foundation etc. as required.
Dismantling of over head lines comprising of aluminium over head conductor(17X50X3X0.148)
Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. as required.
Erection of metallic pole of length above 10mtr and upto 12 mtr in cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
Supplying of two lengths of channel Iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Erection of double pole 3 wire cross arm for 11KV/ 22KV/33 KV over head lines as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) pole top bracket/cross arm for single 11 KV over head line conductor complete with 50 mm X 6mm flat iron clamp, bolts, nuts and washers including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required
Erection of pole top cross arm on steel tubular/rall/ PCC pole for 11 KV
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) V shape cross arm for two 11 KV over head line conductors complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required
Erection of pole V shape two wire, angle iron/ channel iron, cross arm on steel tubular/rall/ PCC pole for 11KV
Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised Insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
Supplying and erection of 11 KV pin insulator complete with large steel head G.I.
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle (20 mm X 600 mm), 7/4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required
Painting with aluminium paint of approved brand and manufacture to give an even shade. Two or more coats on new work.
Earthing with copper earth plate 600 mm X 600 mm X 3mm thick including accessories, and providing masonry enclosure with cover plate having locking 15 arrangement and watering pipe of 2.7 metre long etc.with charcoal/coke and salt as required.for shifting of Transformer and Re installation
Loading unloding of Transformer from one place to another in the range of 10 km
Supplying and errection of three piece non linear resistor type lightning arrestor suitable for 3 wire, 11kv overhead lines with rated voltage 9 KV(rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangment Gl bolts, nuts, washers etc.as required.
Providing and fixing 6 SWG dia Gl wire on surface or in recess for loop earthing as required
Erection of cradle guard as required
Supply of 6 SWG G.I wire
Erection of G.I wire no-6/8 SWG Including binding etc.as required for cage cradle and crosslacing.
Total impact of GST for the purpose of CTC
M/S HEMANT KUMAR YADAV
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_318894.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .