| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.0 LAccepted-AOC NO 26 SRI GANESH 7TH CROSS BDS NAGAR DIBBUR RAMAIAH LAYOUT K NARAYANPURA MAIN ROAD BANGALORE 560 077 | BENGALURU URBAN | KARNATAKA | 560077 | L1 | Accepted-AOC Lowest Bid Value | |
| 2 | L2₹30.9 L+₹3.2 L (11.7%)Rejected-AOC NO157 14 13TH B MAIN ROAD 1ST STAGE 1ST PHASE GOKULA BANGALORE 560054 | BENGALURU URBAN | KARNATAKA | 560054 | L2 | Rejected-AOC Higher Bid Value | |
| 3 | L3₹31.0 L+₹3.3 L (12.1%)Rejected-AOC 66 C O J R NAICKER ASWATHNAGAR SANJAYNAGAR P O BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L3 | Rejected-AOC Higher Bid Value | |
| 4 | L4₹31.9 L+₹4.3 L (15.5%)Rejected-AOC | L4 | Rejected-AOC Higher Bid Value | |
| 5 | L5₹38.0 L+₹10.4 L (37.5%)Rejected-AOC | L5 | Rejected-AOC Higher Bid Value |
Tender Value
Refer Docs
EMD Value
₹72,000
Closing Date
12 Jun 2021, 6:00 pmClosed
GE (AF) BANGALORE
GE (AF) BANGALORE, HQ TC AIR FORCE , BANGALORE 560006
REPAIRS / MAINTENANCE TO DRAINS, CULVERTS AND FOOTPATH AT HQTC BANGALORE
2021_MES_442330_1
8779/GE/19
Open Tender
Civil Works
Item Rate
270 days
HQ TC BANGALORE
AS PER NIT
5 documents required · 5 mandatory
₹500
Yes
GE (AF) BANGALORE
₹72,000
Yes
7 Sept 2021
12 May 2021
14 Jun 2021
12 May 2021
12 Jun 2021
31 May 2021
13 May 2021 - 26 May 2021
Amount
Desilting of drains including cleaning of shrubs/ bushes, vegetation manually or mechanical means and making good to re-use and removal of material to a distance exe 15.0 Km and deposited where directed at a level not exe 1.50 m above starting point, complete all as specified and directed.. Note :- All desilting sand, shurbs and bushes vegetation shall be removed from MOD land during or at the end of each working period at his risk and cost in accordance with all applicable federal , state , and local regulations.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed. Note: All debris and rubbish shall be removed from MOD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state, and local regulations.
Cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete, complete all as specified and directed.
PCC 1:2:4, type B-0 (using 12.5 mm graded stone aggregate) as in coping and benching and the like including weathering slightly rounded or chamfered angle and throating, complete all as specified and directed.
PCC 1:3:6 type C-1 (using 20mm graded stone aggregates) as in surface channel or drains, complete all as specified and directed
25mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded stone aggregate), complete all as specified and directed.
40mm thick Cement concrete type B-1, 1:2:4 (20mm graded stone aggregate), complete all as specified and directed.
75mm thick Cement concrete type B-2, 1:2:4 (40mm graded stone aggregate), complete all as specified and directed.
Providing precast cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in Kerb stone including match with the existing kerb stone shape and size with necessary excavation work window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, coping for staging of water tank, cover slab of manhole and septic tank etc, kneelers, apex stones, pier caps, coloumns, posts, boundary pillars, bed plates, pintle blocks, bonders (for stone walling). corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in mortar complete with joints to match, set in CM 1:6, complete all as specified and directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition ) of any description & in any position not specifically provided for, complete all as specified and directed. Note: All debris and rubbish shall be removed from MOD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state, and local regulations.
Pre-cast reinforced cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in cover slabs for manholes and the like etc; set in cement mortar 1:4 with plain fair faces, complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) rough finished surfaces of concrete, Complete all as specified and directed.
Reinforced cement concrete type B-1 1:2:4 (20 mm graded aggregte ) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed.
TMT Bars 10mm dia and over, cut to length, bent to shape required, inculding cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips including necessary form works, complete all as specified and directed.
TMT bars 6 mm to 8 mm dia , cut to length , bent to shape required including cranking bending etc and binding with mild steel wire not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
Providing precast cement concrete louvres and jallies, type B0 1:2:4 (12.5mm)graded aggregate)50 mm thick (measured solid) including all mouldings but not excluding frame set in cement mortar 1:4 including taking down old unserviceable jailies etc., complete all as specified and directed.
Demolition of brickwork or stone/boulder masonry, built incement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified & directed. Note: All debris and rubbish shall be removed from MOD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state, and local regulations.
Pre-cast cement concrete block masonary with solid blocks, Type C-1 1:3:6 (20mm graded stone aggregate), exc 10 cm in width and setting in cement mortar in CM 1:6, complete all as specified & directed.
All as per Srl item No 18 here-in-before, but except bricks, complete all as specified & directed
Brickwork with subclas ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in in CM (1:4), complete all as specified and directed.
Walling of randam rubble uncoursed well bonded , bedded and solidly hearted built in cm 1:6, complete all as specified and directed.
All as per Srl item No 21 here-in-before, but except stonte, complete all as specified & directed
Flush pointing to random rubble masonry, uncoursed or brought upto courses in CM 1:4, complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc., complete all as specified and directed.
Rendering 15 mm thick in cm 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement, complete all as specified and directed.
Flush pointing to brick wall in CM 1:4, complete all as specified and directed
M&L for Neeru finish to plastering, complete all as specified and directed.
Brushing neat cement slurry with 3.0kg of cement per sqm, complete all as specified & directed.
Forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc., complete all as specified and directed
Add or deduct in item No 29 for each 25 mm girth or part thereof over or under 30cm, complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not other wise provided for, complete all as specified and directed.
Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165, complete all as specified and directed.
Dismantling cast iron work of any description, complete all as specified and directed.
Cast iron work grade FG 150, unmachined, in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar articles (Articles n.exc 5 kg each), complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed. Note: All debris and rubbish shall be removed from MOD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state, and local regulations.
Glazed ceramic coloured/digital tiles in vertical surface 350x250mm x 7mm/ 450x350x7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick bedding layer of cement mortar 1:4, complete all as specified and directed.
M&L for chequered cement concret tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry with white cement & pigments in floors over 20mm thick screed bed of cement mortar 1:6 all as specified & directed.
Endura vitrified tiles of size 30cm x 30cm, 8 to 12mm thick, set, jointed and pointed in neat cement slurry with white cement & pigments in floors over 20mm thick screed bed of cement mortar 1:6, complete all as specified & directed.
Machine pressed precast conctete coloured interlocking paver block any shape and size conforming to IS 15658-2006 of 60mm thickness M-35 grade with grey cement and pigments over 40mm thick sand cushioning including dismantling of unserviceable old unserviceable paver block, complete all as specified and directed. Note: All debris and rubbish shall be removed from MOD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state, and local regulations.
All as per item No 39 but using old serviceable interlocking paver block, complete all as specified & directed
Demolition of stone slabs and tiles of any description or thickness in floors, apron etc., complete all as specified and directed. Note: All debris and rubbish shall be removed from MOD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state, and local regulations.
20mm thick granite (of any type) work (table rubbed and polished) of any colour or texture for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and directed.
20mm thick granite (of any type) work (table rubbed and polished) of any colour or texture in steps, jambs, pillars, cooking plateform, window sill and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade granite incl 15mm thick screed bed in CM 1:6, complete all as specified and directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar and internal dia of pipe300 mm, complete all as specified and directed. Note: All debris and rubbish shall be removed from MOD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state, and local regulations.
All as per Srl item no 44 above but 450mm bore, complete all as specified and directed.
All as per Srl item no 44 above but 600mm bore, complete all as specified and directed.
Reinforced concrete pipes 300mm bore, class NP-3, laid and jointed complete with collers, complete all as specified and directed.
All as per Srl item no 47 above but 450mm bore, complete all as specified and directed.
All as per Srl item no 47 above but 600mm bore, complete all as specified and directed.
Concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:3:6 type C-2 for 300 mm dia pipe, complete all as specified and directed.
All as per Srl item no 50 above but 450mm bore, complete all as specified and directed.
All as per Srl item no 50 above but 600mm bore, complete all as specified and directed.
Dismantling of PVC drain pipes of 150/110mm bore including all fittings jointed in cement mortar and taking out of trenches or from wall , if required and removing from site of work, complete all as specified and directed.
PVC (SWR) pipes 150mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed.
Concrete bed to drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested; in cement concrete 1:3:6 type C-2 for 150 mm dia pipe, complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth for foundation manholes etc and getting out in hard/dense soil, complete all as specified and directed.
Excavation over areas not exceeding 1.5 m deep & getting out, in soft/ loose soil, complete all as specified and directed.
Returning , filling in including spreading , levelling , watering and well ramming in layers not exc 25 cm in solft/loose soil, complete all as specified and directed.
Removing excavated material n exc 15 Km and depositing where directed at a level n exc 1.5 m above the starting point soil, complete all as specified and directed.
Preparing plastered or un-plastered new surfaces of walls and applying three coats of white wash, complete all as specified & directed.
Preparing of old chequered tiled surfaces/existing footpath by removing all the caked mud with wire brushes and cleaning surfaces with necessary acid and description not otherwise described and applying one coat of weather proof tile guard apex paint or equivalent of any colour, complete all as specified and directed.
All as per item No 61 here-in -before but two coats of weather proof tile guard apex paint or equivalent of any colour, complete all as specified and directed.
Preparation of old decorated plsatered or unplastered surface of walls including scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc. and applying one coat of white washing, complete all as specified and directed.
All as per item No 63 here-in -before but two coats of white washing on walls, complete all as specified and directed.
Grubbing up tree trunk including cutting of trunk portion exc 30cm and n.exc 100cm girth protruding over ground, digging out roots, filling holes and leveling off ground, stacking of serviceable material and removing of unserviceable material to a distance n exc. 50 m and clearing site, complete all as specified and directed.
Two coats of synthetic enamel paints over a coats of red oxide primer including prepration of new/previously untreated steel surfaces of any description over 10 cm in width or girth not otherwise described, complete all as specified and directed.
Steel work in tubular trusses Gde Fe 410 -W (Gde- E- 250) quality- AFe- including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, complete all as specified and directed.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed.
Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
Pre-painted galvalume aluminum zinc coating GI 0.50mm thick of any colour having tensile, complete all as specified and directed. strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified ®
N RAJEGOWDA and CO
OM Enterprises
chowdeshwariconstructionco
P Ramesh and Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .