| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹37.1 L+₹44,283.30 (1.21%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹40.1 L+₹3.4 L (9.30%)Rejected-Finance MHALASA ROAD BINAGA TALUKA KARWAR DISTRICT UTTAR KANNADA KARNATAKA 581307 | KARWAR | UTTAR KANNADA | KARNATAKA | 581307 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹41.7 L+₹5.1 L (13.8%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹44.1 L+₹7.5 L (20.4%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹49.9 L
EMD Value
₹99,800
Closing Date
25 Apr 2025, 6:00 pmClosed
GE (SB) KARWAR
GE (SB) KARWAR
CERTAIN REPAIR TO TOILETS FLOOR,SUNKEN FLOORS LEAKAGE SEEPAGE AND PLUMBING WORKS IN-LIVING SAILORS ACCN BLOCKS AND GALLERY AT NAVAL BASE KARWAR AND REPAIR AND MAINTENANCE OF INTERNAL ELECTRIFICATION, FITTINGS AND FIXTURES EARTHING OF MARRIE
2025_MES_702542_1
8313/E8
Open Tender
Civil Works
Item Rate
330 days
GE (SB) KARWAR
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (SB) KARWAR
₹99,800
Yes
26 Jun 2025
28 Mar 2025
28 Apr 2025
28 Mar 2025
25 Apr 2025
11 Apr 2025
28 Mar 2025 - 8 Apr 2025
Amount
Demolition of cement concrete of any description in sunken floor or in any position as specified and directed. .
Material and labour for Treatment of sunken floor slab compriases of the following specifications and all as specified :-(i) M&L for cleaning the sunken/lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely. 40mm thick average PCC 1:2:4 type B0 using 12.5mm graded aggregate as in padding conc to achieve proper slope (ii) Rendering of uneven surfaces with 6mm thick CM 1:4 mixed with integral water proofing compound @ 3% BY WT OF CEMENT CONSUMED. Fill it with water and check dampness and seepage. Where dampness/seepage is noticed, nozzles shall be fixed and grouting to be carried out (WPC shall be measured and paid separately) (iii) All junctions points of side wall where CI/GI pipes are passing through shall be sealed with epoxy putty (iv) After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean
(v) M&L for applying two coats of polymer modified cementious water proof coating as per manufacturers instruction to bottom and vertical sides up to finished floor level +100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky,, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed. (This item shall be measured and paid separately). (vi) Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with integral water proofing compound @3% wt of cment consumed as per manufacturer's specification including rounding of corners and junctions sloping towards spout. (WPC shall be measured & paid separately ) Note :- Test the water proofed area (ponding test) by filling water for at least 72 hours and tested for leakage seepage and to the entire satisfaction of GE. Test shall be done in presence of reps of PMG and record for each sunken slab shall be maintained. The treatment shall be carried out by authorised applicators of chemicals. Cost of testing is included in the rates quoted above. (vii) All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 all round after painting with anticorrosive paint (Black paint shall be paid separetely)
M&L for applying two coats of polymer modified cementious water proof coating as per manufacterors instruction to bottowm and vertical sides up to finished floor level +100 mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed.
Supply only Integral Water proofing compound complete all as specified and directed.
M/L for PCC in 1:5:10 type E2 (using 40 mm graded agg) as in sunken floor of toilet complete all as specified and as directed.
Taking up or down GI tubing and connections 15mm bore including cleaning or removal to store all as specified and directed.
Taking up or down GI tubing and connections 20mm bore including cleaning or removal to store all as specified and directed.
S&F 15 mm dia UPVC pipes of pressure rating 10 Kgf/cm2 fixed to walls, ceiling or in floors etc complete all as specified and directed.
S&F 20 mm dia UPVC pipes of pressure rating 10 Kgf/cm2 fixed to walls, ceiling or in floors etc complete all as specified and directed.
S&F in repairs stop valves/angle valve, cast copper alloy fancy type chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe of 15mm bore all as specified and directed
S&F in repairs stop valves, cast copper alloy fancy type chromium plated with long shank and cup (concealed type) for iron pipe of 15mm bore of complete all as specified and directed.
S&F in reapir 25 mm dia gun- metal globe or gate valves, with iron wheel head screwed both ends for iron pipe, complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing all the rubbish etc complete all as specified and directed.
M&L for coloured glazed ceramic tiles (Ist quality) of size 300 x 200 x 6 to 7 mm / 300 x 450 x 6 to 7 mm thick on vertical surfaces such as skirting, dado and rises to steps etc. including 10mm thick cement plaster in CM 1:3 set and set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles complete all as specified and directed.
M & L for non skid ceramic coloured tiles (Ist quality) 7 to 8 mm thick (Square/ rectangular), area of each tile exc 0.06 Sqm but n.exc 0.11 sqm as in floors etc laid over and including 15mm thick screed bed in CM 1:4 and set and jointed in neat grey cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
Taking down chowkats or frames exc 1.5sqm but n.exc 4 sqm each but with shutter (without taking off shutter from the frame) complete all as specified and as directed
All as per Item No.16 here-in-before but n.exc 1.5 sqm complete all as specified and as directed
S&F solid PVC door frame of size 50mmx 47mm made out of 5mm wood grains printed PVC sheet reinforced with MS square tube and edges painted to match with printed sheet complete all as specified and directed.
S&F factory made solid panel PVC door shutter 30 mm thick (styled) consisting of frame made out of MS tube for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC ,C" channel having a PVC sheet strip of 20mm width stuck in side with solvent cemet for stiles and plain colour PVC sheet for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet bedding and jointed together with solvent cement supply and fixing in the frame at site all as specified and directed.
S&F 150mm long Aluminium anodized handle of extruded sections etc complete all as specified and directed.
S&F 100 mm medium weight Mild Steel Butt hinges to the frame etc complete all as specified and directed.
S&F 75 mm medium weight Mild Steel Butt hinges to the frame etc complete all as specified and directed.
S&F 150mm long aluminium anodized barrel tower bolts of extruded sections complete all as specified and directed.
S&F 300mm long aluminium alloy, anodized sliding door bolts with hasp & staple (bolt type) and fixing clips of sheet cost of extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed.
S&F in repairs vitreous china water closet (Squatting pan) “Orissa” pattern of size 580 x 440 mm white with integral foot rest and ‘P’ trap (excluding flushing cistern) but including PVC flush pipe and provision of lime concrete bedding as fixed in repairs complete all as specified and directed.
S&F in repairs vitreous china wash down water closet (pedestal pattern) white, including fixing bolts and necessary connection with existing pipes etc complete all as specified and directed. Note : Quoted rate shall excludes the cost of flush pipe, cistern & seat cover and the same shall be paid seperately under respective item.
S&F in repair for seat cover for pedestal pan with plastic water closet seat, white, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
S&F in repairs for 10 litre capacity PVC valveless syphonic action type flushing cistern high or low level (exclusive of brackets) white with inlet ball valve, float and handle inlcuidng brackets complete all as specified and directed.
S&F in repairs for providing 15 mm dia PVC connection of length 450mm long complete all as specified and directed.
S&F in repairs flush pipes PVC 32mm dia for low level flushing cisten to pedestal pan, including all joints, cones, India rubber (nozzles of W.C pans) all as specified and directed.
S&F in repairs brass Chromium Plated Health faucet with spring pipe and rquired nipple all as speified and directed.
S&F in repairs two way bib cock with two lever and wall flage chromium plated brass of approved make, screwed for iron pipe 15mm bore complete all as specified and directed
S&F in repairs Wash hand basin vitreous china (flat back) size 550 x 400 mm including brackets waste brass chromium plated with long screwed shanks and fly nuts 32 mm size including bottle trap complete all as specified and directed.
S&F in repairs fancy type pillar taps cast copper alloy with capstan heads chromium plated screwed down high pressure with lettered hot or cold with long screwed shanks and fly nuts screwed for iron pipe and 15 mm bore of pipe Note:-MAKE For Fancy type Pillar - Hinderwear Cat. No.: F570023 Sink Cock With Normal Swivel Spout-Wall Mounted or equivalent
S&F in repairs 32mm dia PVC waste pipe for WHB and urinals complete all as specified and directed.
S&F in repairs 32mm size waste fitting (coupling) brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed all as specified and directed.
S&F in repairs 80mm dia brass chromium plated shower rose with swivel joints fancy type suitable for 15mm bore GI pipe all as specified and as directed.
S&F in repairs brass chromium plated mixer for mixing hot & cold water screwed down for 15mm dia iron pipe of complete all as specified and directed.
S&F in repairs for vitreous china urinals, bowl type (back or corner wall type,) complete including providing and fixing plugs bedding urinal against wall in cement mortar in 1:2 securing urinals to plugs with and including 60 mm long brass screws, pointing around urinal back in cement , fixing automatic flushing cisterns with brackets, flush pipes, inlet ,outlet etc complete all as specified and directed.
S&F Push type taps for urinals, cast copper alloy with crutch or butterfly handle, screwed down, screwed for 15mm dia iron pipe or for brass ferrule and fixed in repairs complete all as specified.
S&F in repairs bib taps, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe 15mm bore complete all as specified and directed.
M&L for PVC (SWR) pipe single socketed in any length with rubber ring joints laid in trenches or in floors of 110mm bore etc complete all as specified and directed.
M&L for PVC (SWR) pipe single socketed in any length with rubber ring joints laid in trenches or in floors of 75mm bore complete all as specified and directed.
S&F 75mm dia PVC (SWR) bend all as specified and directed.
S&F 100mm dia PVC (SWR) bend all as specified and directed.
S&F PVC (SWR) floor trap of 110mm dia, plain with grating including jointing with solvent cement etc complete all as specified and directed.
S&F PVC (SWR) floor trap of 75mm dia, plain with grating including jointing with solvent cement etc complete all as specified and directed.
M&L for non skid ceramic coloured tiles (Ist quality) 7 to 8 mm thick (Square/ rectangular), area of each tile exc 0.11 Sqm but n.exc 0.18 sqm as in floors etc laid over and including 15mm thick screed bed in CM 1:4 and set and jointed in neat grey cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for Non skid ceramic coloured tiles (Ist quality) 7 to 8 mm thick (Square/ rectangular), area of each tile exc 0.11 Sqm but n.exc 0.18 sqm on vertical surfaces such as skirting, dado and rises to steps etc. including 10mm thick cement plaster in CM 1:3 set and set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles complete all as specified and directed.
M&L for Vitrified ceramic tiles of premium quality, light shade, 9-10 mm thick (square/ rectangular) polished area of each tile not exceeding 0.36 Sq.m (size 600 x 600 mm), laid in floors with neat cement slurry @ 3.00 kg/Square Metre over and including 15 mm thick screed bed of cement mortar (1:4) including pointing in white cement with pigment to match the shade of tiles, complete all as specified.
M&L for vitrified coloured tiles of 600x 600 x 9-10 mm thick as in skirting set and jointed in neat cement slurry and pointed in colour cement over 10 mm thick rendering in cement mortar 1:3 including taking down old wall dado/finishes of any description, complete all as specified and directed.
Dismantling of single layer Mangalore pattern or similar tiles in roofing all as specified and directed.
M&L for roof tiles, Mangalore pattern class 'AA', interlocking at side joints, laid dry complete all as specified and directed.
All as per Srl item No.54 here-in-before but except tiles complete all as specified and directed.
M&L for Ridge or hip tiles to suit Mangalore pattern or roofing tiles, bedded and jointed in cement mortar 1:6 complete all as specified and directed.
M&L for cement concrete type C0 1 : 3 :6 (12.5 mm graded aggregate) in roof kerbs or mud stops, or beading for tiles e-ETC chamfered at edges complete all as specified and directed.
Dismantling/taking out existing hessain base felt or any other existing water proofing treatment from roof including cement plaster and exposing the top surface of RCC slab including removing the dismantled debris to a distance exc 200m & n.exc 250m. all as specified and directed
M&L for providing 15mm thick rendering over roof slab in Cement Mortar (1:4) mixed with water proofing compound @ 3% by weight of cement, finished even and smooth surface without using extra cement all as specified and directed
M/L for water proofing treatment by applying oil bound bitumen primer, having a density of 0.87 - 0.89 Kg/lit, @ 0.40 ltrs/Sqm, providing and laying APP modified water proofing membrane weighting not les than 3.50 Kg/Sqm of approved make including minimum 10 cm side lap and 15 cm end lap, laid and pasted with blue flame torching applications and finally finishing with two coats of solar reflective bituminous aluminium paint @ 0.1.Kg/Sqm complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation) or insulation boards /slab /blankets of any description and thickness including frame/grid of any description all as specified and directed
M&L for Anodised Aluminium snap grid (minimum 15 microns anodisation) of size 605 x 605 mm with anodized aluminum angle of size 40mm x 25mm x 2mm thick weighing 0.36 Kg per running meter and anodized aluminum main and cross T of size 36.50 x 23.50 x 1.50 mm thick weighing 0.254 Kg per running meter and 23.50 x 23.50 x 1.50 mm thick weighing 0.202 Kg per running meter respectively for false ceiling all as specified and directed
S&F hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long suitable for size of snap grid 605 x 605 mm complete all as specified and directed
M&L for 10mm thk PVC insulation panels with EPS stuck to 1mm plain PVC sheet suitably placed in false ceiling grid made of Aluminium/G.I./M.S. as per specification etc complete all as specified and directed
M&L for perforated particle board/ tiles for insulation and accoustic purposes of size 60x60cms, 12mm thick fixed with staples on snap grid in ceiling all as specified and directed.
Taking down cement plaster on brick or concrete surfaces of wall/ceiling and likes including racking out joints, hacking for keys scrubbing down with water etc any description including removal of rubbish outside MoD land, complete all as specified and directed. Note : The rate quoted by the Contractor is deemed to be included necessary scafolding and form works.
M & L for Rendering 15 mm thick on brick or concrete surfaces in cement mortar (1:4) mixed with waterproofing compound @3% by weight of cement complete all as specified.
M& L for rendering 10 mm thick in CM (1:6) on fair faces of concrete surfaces all as specified and directed
M&L for 5mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:3 as in ceiling. All as specified and directed
M&L for parparing newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of Primer inclunding finishing of surface with 3mm thk wall care putty etc complete all as specified and directed
M&L for parparing newly plastered surfaces of ceiling and applying two coats of oil bound distemper over a coat of Primer inclunding finishing of surface with 3mm thk wall care putty etc complete all as specified and directed
M&L for two coats of exterior emulsion weather proof paint over a coat of primer including preparation of new plastered surfaces of walls all as specified and directed..
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends,swan-necks etc all as specified and directed.
M&L for PVC Rain water pipe single socketed in any length with rubber ring joints fixed to wall 110mm bore etc complete all as specified and directed.
S&F 110mm dia PVC bend all as specified and directed
Dismantling of PVC/ RCC water storage tank of capacity exceeding 250 litre but not exceeding 500 litre, including removal of rubbish outside MoD land, complete all as specified.
Dismantling of PVC/ RCC water storage tank of capacity exceeding 500 litre but not exceeding 1000 litre, including removal of rubbish outside MoD land, complete all as specified.
S&F Rotational moulded PVC, double layered, water storage tanks of capacity 500 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position, complete all as specified.
S&F Rotational moulded PVC, double layered, water storage tanks of capacity 1000 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position, complete all as specified.
Draining out water, cleaning and removing accumulated sludge/dirt scales from tank bottom, side and from moiths of circulating pipes of service tank of capacity not exceeding 500 ltrs, located on roof of the building and disinfecting the tank using bleaching powder to make the tank bacteria free, writing by stencil date of cleaning of tank with white synthetic enamel paint on black ground " CLEANED ON ( DATE)" height of the words 100mm, complete all as specified and directed.
Draining out water, cleaning and removing accumulated sludge/dirt scales from tank bottom, side and from mouths of circulating pipes of service RCC/PVC tank of capacity exceeding 500 ltrs but not exceeding 1000 ltrs, located on roof of the building and disinfecting the tank using bleaching powder to make the tank bacteria free, writing by stencil date of cleaning of tank with white synthetic enamel paint on black ground " CLEANED ON ( DATE)" height of the words 100mm, complete all as specified and directed.
Supplying and fixing in repairs 25 mm bore brass float valve, high pressure with polythene float & fly nut complete, screwed for GI pipe of following sizes including necessary GI fittings complete all as specified.
Supplying and fixing in repairs 40 mm bore brass float valve, high pressure with polythene float & fly nut complete, screwed for GI pipe of following sizes including necessary GI fittings complete all as specified.
Removing excavated/demolished material not exceeding 50 m and deposited where directed at a level not exc 1.5 m above the base as directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. etc complete all as specified and directed.
M&L for point wiring with 1.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continous earth wire to common earth and connected to earth with 1.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable draw in existing conduit and making good disturbed surfaces to match with the existing surface complete all as specified and directed by Engr-in-Charge.
(a) One light/fan point controlled by one switch complete all as specified and directed.
(b) One 3/5 pin socket outlet 6 Amp on same board with other switches complete all as specified and directed.
All as per item No.86 here-in-before but One 3 pin socket outlet 5 Amp on independent board complete all as specified and directed.
All as per item No.86 here-in-before but with cables 2.5 Sqmm for one 3 pin socket outlet 15 Amps on independent board complete all as specified and directed.
All as per item No.86 here-in-before but with cables 4 Sqmm for one 3 pin socket outlet 15 Amps on independent board complete all as specified and directed.
Supply & fix in repairs MCB TPN, 16 To 32 AMP, 415 Volts, 3 phase, 10 KA Capacity all as specified and directed. MAKE: Havells/L&T/Legrand/ABB/Seimens or as approved by GE.
Supply & fix in repairs MCB TPN, 40 To 100 Amps, 415 Volts, 3 phase, 10 KA Capacity all as specified and directed. MAKE: Havells/L&T/Legrand/ABB/Seimens or as approved by GE.
Supply & fix in repairs MCB SPN, 32 Amps, 'C Series ,230 Volts, Single phase, 10 KA Capacity all as specified and directed. MAKE: Havells/L&T/Legrand/ABB/Seimens or as approved by GE.
Supply & fix in repairs MCB SP, 5 to 32 Amps, 'C' Series,230 Volts, Single phase, 10 KA Capacity all as specified and directed. MAKE: Havells/L&T/Legrand/ABB/Seimens or as approved by GE.
Taking down ceiling fan/exhaust fan of any sweep, dismantling, replacing defective part, overhauling, cleaning, greasing, rewinding, etc and hanging up/fixing back in the original position, connecting up and testing complete all as directed. NOTE: 1. The unit rate quoted shall be deemed to include for minor items viz nuts,bolts split pin and rubber wheel, however capaciteor & bearing shall be measured sperately under respective items. 2. Rewinding of fan will be measured and paid for separately under respective items.
Supply and fix in repairs ceiling fan regulator electronic step type 230 Volts single phase all as specified and directed. MAKE: Anchor/Bajaj/Legrand/Havells.
Supply and fix in repairs capacitor of 2.5 mfd for ceiling fan/exhaust fan complete all as specified and directed. Make: Havells/Bajaj/Crompton Greaves/Phillips.
Supply and fix bearing No.6201/6202/6203 for ceiling fan/exhaust fan complete all as directed. Make: SKF/TATA or as approved by GE.
M & L for removing of burnt out copper winding wire from ceiling fan of any make and size of 1200 mm to 1400 mm sweep including cleaning of slots etc and rewinding with super enameled copper winding wire as per existing size/gauge including insulating material, varnishing and drying complete all as specified and directed.
M&L for Painting of ceiling fans complete, in situ/lying in store with synthetic enamel paint (white colour) by spraying including filling cavities with filler, one coat after cleaning all dust complete all as specified and directed.
S&F in replacement cup made of plastic complete with nut bolt for fixing in position suitable for ceiling fan 1200mm/1400mm sweep complete all as specified and directed.
S&F in replacement blade suitable for 1200mm sweep Ceiling fan complete all as directed.
S&F in replacement blade suitable for 1400mm sweep Ceiling fan complete all as directed.
S&F in replacement of ceiling fan downrods of length 1-2 ft suitable for 1200/1400mm ceiling fans. The quoted rate should also include for the clamps necessary for the proper fixing of the ceiling fan complete all as directed.
All as per item No 103.00 above but exhaust fan of 300 mm sweep complete all as directed.
All as per item No.103.00 above but exhaust fan of 450 mm sweep, 3 phase 415 Volt complete all as directed.
Taking down submain wiring cable any number of runs alongwith earth wire from the existing concealed or surfacae conduit and offering credit as per schedule of credit all as directed.
M&L for Wiring circuit/submain wiring alongwith earth wire with 2x6.0 sq.mm+1x6.0 sq.mm earth wire of FR is PVC insulated copper conductor, single core cable in surface/recessed as required In existing steel/conduit, casing/caping, surface/ recessed complete all as specified and directed by Engr-in-Charge.
M&L for Wiring circuit/submain wiring alongwith earth wire with 2x6.0 sq.mm+1x6.0 sq.mm earth wire of FR is PVC insulated copper conductor, single core cable in surface/recessed as required In casing/caping complete all as specified and directed by Engr-in-Charge.
M&L for Wiring circuit/submain wiring alongwith earth wire with 2x4.0 sq.mm+1x4 sq.mm earth wire of FR is PVC insulated copper conductor, single core cable in surface/recessed as required In casing/caping complete all as specified and directed by Engr-in-Charge.
S&F in repairs MCB DB TPN 415 Volt 4 way & single door and factory made complete with bus bar and din channel complete all as directed. MAKE: Havells/ABB/Legrand/Schneider/L&T or as approved by GE.
Supply and fix in repairs switch Piano 6 Amps one way flush type, matching with existing make, ISI marked, all as specified and directed. MAKE: Havells/Anchor/Legrand/Phillips.
Supply and fix in repairs socket outlet 3/5 pin 6 Amps flush type, matching with existing make ISI marked, all as specified and directed. MAKE: Havells/Anchor/Legrand/Phillips.
Supply and fix in repairs switch Piano 15/16/20 Amps one way flush type, matching with existing make ISI marked, all as specified and directed. MAKE: Havells/Anchor/Legrand/Phillips.
Supply and fix in repairs socket outlet 3/5 pin 15/16 Amps flush type multi purpose, matching with existing make ISI marked, all as specified and directed. MAKE: Havells/Anchor/Legrand/Phillips.
Supply and fix in repairs switch socket combination 5 pin 16 Amps flush type multi purpose, matching with existing make ISI marked, all as specified and directed. MAKE: Havells/Anchor/Legrand/Phillips.
Supply and fix in repairs 2 way switch piano 5 or 15 Amps flush type single pole ISI marked all as specified and directed. MAKE: Havells/Anchor/Legrand/Phillips.
Supply and fix in repairs Calling Bell/Buzzer Ding Dong 230 Volts AC Single pole matchin with existing make with ISI marking, all as specified and directed. MAKE: Havells/Anchor/Legrand/Phillips.
Supply and Fixing in repairs Bell Push flush type 230 Volts 5 Amps compatible with existing Door bell matching with existing make ISI make, all as directed and specified. MAKE: Havells/Anchor/Legrand/Phillips.
M&L for Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings all as directed. MAKE: Havells/Anchor/Legrand/Phillips.
S&F in repair Inverter LED 20W light, white colour temperature 6500K along with batten consisting of a Lithium Ion battery with charging time 8-10 hours and back up time upto 4 hours complete with all connected accessories including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed. Make : Havells/Bajaj/Philips/ Wipro/ C&S/ Shakti or as approved by GE
Supply &Fxing in repiar 20 W LED batten including tube rod of length 4 feet, 230 Volts, complete with all connected accessories including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed. Make : Havells/Bajaj/Philips/ Wipro/ C&S or as approved by GE.
S&F in repair T8 LED tube rod 18/20 W, 4 feet length, 6000K complete with all accessories as specified and as directed. Make : Havells/Bajaj/Philips/Wipro/Shakti/C&S or equivalent.
S&F in repair 10 watt LED light fittings 2 feet including making necessary connection complete all as specified and directed. Make : Havells/Philips/C&S/Bajaj/Shakti or equivalent.
S&F in repairs MCB DB SPN, 8 way, 240 Volt, double door powder coated sheet steel enclosure for surface mounting fitted with 200 Amps bus bar and din channel complete all as specified and directed. Make : Havells/Indo Asian/Legrand or equivalent.
M&L for testing of resistence of earthpits of transformer/panels/ buildings or any other indicated place etc after testing report will be furnished to Engr-in Charge in standard format approved by Engr-in Charge.
M&L for taking down the existing faulty single phase tamper proof Electronic Energy meter with LCD display 230 volts 4 wire system, 10-60 amps, 50 Hz ,replacing the unserviceable chip board complete,making it to serviceable state, including testing, caliberation & refixing the same complete all as specified and directed by Engr-in-Charge.
K.G.SHANKER (BID ID -3284019)
MHALASA CONSTRUCTIONS (BID ID -3287769)
Ms V. S. NAYAK (BID ID -3284060)
H S KRISHNA ELECTRICALS (BID ID -3282850)
SIRI SALES AND SERVICES (BID ID -3287707)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .