| 1 | 1₹19.6 LAccepted-Finance 1017 SMALL FLAT DHANAS U T CHANDIGARH | ₹19.6 L | 1 | Accepted-Finance DUE TO L-1 AGENCY |
| 2 | 2₹20.3 LRejected-Finance 0 A K ENTERPRISES SADAR ROAD BALOD GANGA MAIYA BOOK DIPO NEAR BALOD CHHATTISGARH 491226 UDYAM CG 17 0002983 | BALOD | CHHATTISGARH | 491226 | ₹20.3 L | 2 | Rejected-Finance RATE ON HIGHER SIDE |
| 3 | 3₹20.7 LRejected-Finance 1296 SECTOR 41 B CHANDIGARH 160036 | CHANDIGARH | CHANDIGARH | 160036 | ₹20.7 L | 3 | Rejected-Finance RATE ON HIGHER SIDE |
| 4 | 4₹21.1 LRejected-Finance 670 A SMALL FLAT DHANAS UT CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | ₹21.1 L | 4 | Rejected-Finance RATE ON HIGHER SIDE |
| 5 | Rejected-Technical M S A K ENTERPRISES C P DIVISION NO 6 SECTOR 9 D U T CHANDIGARH B 12 2723 ADARSH NAGAR NAYA GAON MOHALI PUNJAB | CHANDIGARH | CHANDIGARH | 160001 | - | - | Rejected-Technical AFFIDAVIT NOT IN ORDER |
Tender Value
₹26.7 L
EMD Value
₹53,321
Closing Date
1 Apr 2026, 11:00 amClosed
XEN CP3
XEN CP3 SEC 16 CHD
ROOF WORK AND MISCELLANEOUS REPAIR WORK IN LAKE CLUB SECTOR 6 CHANDIGARH.
2026_CHD_91463_1
CP3/2026/2678635
Open Tender
Civil Works
90 days
SECTOR 6 CHANDIGARH.
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹53,321
2 Apr 2026
25 Mar 2026
1 Apr 2026
25 Mar 2026
1 Apr 2026
25 Mar 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
Providing and fixing false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange f1Xed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x1Ox0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channelwith connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling f1Xed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c:Jc, includingjointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound ,jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011(Board with BIS certification marks) | - | Sqm | - | - | |
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with holdfast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Second class teak wood (as per site) | - | Cum | - | - | |
Renewing glass panes, with wooden fillets wherever necessary: Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) | - | Sqm | - | - | |
Regrading terracing of mud phaska covered with tiles or brick, in cement mortar by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud phaska to proper slope, relaying mud plaster gobri leaping and tiles or bricks, grouted in cement mortar 1:3 (1 cement : 3 fine sand), including replacing unserviceable tiles or bricks with new ones and disposal of unserviceable material to the dumping ground (the cost of the new tiles or brick excluded), all complete as per direction of Engineer-inCharge. | - | Sqm | - | - | |
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement :2 coarse sand :4 stone aggregate 10 mm and down gauge), including finishing with cementmortar 1:3(1cement :3finesand) asperstandarddesign : In 75x75 mm deep chase | - | Rmt | - | - | |
Making khurras45x45 cmwithaverageminimum thicknessof5cmcement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. | - | Each | - | - | |
Providing and laying in situ five course water proofing treatment with APP (Atactic Polypropylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd & 4th courses of bonding material @ 1.20 kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd layer of roofing membrane APP modified Polymeric membrane 2.0 mm thick of 3.00 Kg/ sqm weight consisting of five layers prefabricated with centre core as 100 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 5th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately). | - | Sqm | - | - | |
Scrubing the old surface of existing bitumeous coating with electric cutter blades upto mother slab top and cleaning the surface comlete in all respect and removing of malba away from roof slab in local complex complete in all respects same as per direction and to the entire satisfaction of Engineer-in-charge. | - | sqm | - | - | |
Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour Old work (one or more coats) | - | Sqm | - | - | |
Painting with synthetic enamel paint of opproved brand and manufacture of required colour to give an even shade | - | Sqm | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 7.21 MB
BOQ_111869.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid