Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.1 LAccepted-AOC 691 INDUSTRIAL AREA PHASE II CHANDIGARH 160 002 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160002 | ₹29.1 L Quoted ₹31.1 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹31.7 L+₹59,216.04 (1.91%)Rejected-Finance | ₹31.7 L+₹59,216.04 (1.91%) | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹32.0 L+₹94,940.90 (3.06%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | ₹32.0 L+₹94,940.90 (3.06%) | L3 | Rejected-Finance Other than lowest bidder |
| 4 | L4₹43.6 L+₹12.5 L (40.2%)Rejected-Finance | ₹43.6 L+₹12.5 L (40.2%) | L4 | Rejected-Finance Other than lowest bidder |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
24 Jan 2022, 6:00 pmClosed
GE (AF) MC Chandigarh
GE (AF) MC Chandigarh
REPAIRS TO GI PIPE LINE AT RESIDENTIAL AREA AT BRD AIR FORCE STATION CHANDIGARH UNDER GE (AF) MC CHANDIGARH
2021_MES_496398_1
GE (AF) MC /CHD-69/2021-2022
Open Tender
Civil Works
Item Rate
270 days
CHANDIGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) MC Chandigarh
₹92,000
Yes
7 Feb 2022
21 Dec 2021
26 Jan 2022
21 Dec 2021
24 Jan 2022
10 Jan 2022
Amount
Excavation in trenches in soft/loose soil not exc 1.5 m wide and not exc 1.5 m deep for laying of pipes etc and getting out including cutting of grass and bushes complete all as specified and directed.
Returning, filling in, including, spreading, levelling, watering and well remming in layers not exceeding 25cm thick complete all as specified and directed.
Removal of surplus soil to a distance not exc 50 m away and depositing where directed at a level not exc 1.5 above the starting point complete all as specified and directed.
Taking out unservicable pipe line CI/DI of size 150 mm dia and setting aside for reuse after cleaning including taking out lead from joints or issue in credit, complete all as specified and directed.
Taking out unservicable pipe line CI/DI of size 100 mm dia and setting aside for reuse after cleaning or issue in credit including taking out lead from joints, complete all as specified and directed.
Taking out unserviceable pipe line CI/DI of size 80 mm dia and setting aside for reuse after cleaning or issue in credit including taking out lead from joints, complete all as specified and directed. Note for item 4.00 to 6.00 :- (i) Excavation and earth work shall be measured and paid separately. (ii) Existing old unserviceable pipe line CI/DI shall be disconnected only after making alternative arrangements. No supply shall be hampered in any case.
Supply, laying ,testing DI pipe lines conforming to IS 8239-2000, class K-9 (ISI mark) of size 150 mm including all fittings making connection to existing lines with spigot and socket ends including rubber ring joint (tyton joint) , complete all as specified and directed. Note:- Excavation and earth work shall be measured and paid seperately.
Supply, laying ,testing DI pipe lines conforming to IS 8239-2000, class K-9 (ISI mark) of size 100 mm including all fittings making connection to existing lines with spigot and socket ends including rubber ring joint (tyton joint) , complete all as specified and directed. Note:- Excavation and earth work shall be measured and paid seperately.
Supply, laying ,testing DI pipe lines conforming to IS 8239-2000, class K-9 (ISI mark) of size 80 mm including all fittings making connection to existing lines with spigot and socket ends including rubber ring joint (tyton joint) , complete all as specified and directed. Note:- Excavation and earth work shall be measured and paid seperately.
Cleaning of CI/DI pipe of size 150mm dia removed under item No. 4 above and laying, jounting and connecting with the water supply line under and above ground, complete all as specified and directed. Note:- Excavation and earth work shall be measured and paid seperately.
Cleaning of CI/DI pipe of size 100mm dia removed under item No. 5 above and laying, jounting and connecting with the water supply line under and above ground, complete all as specified and directed. Note:- Excavation and earth work shall be measured and paid seperately.
Cleaning of CI/DI pipe of size 100mm dia removed under item No.6 above and laying, jounting and connecting with the water supply line under and above ground, complete all as specified and directed. Note:- Excavation and earth work shall be measured and paid seperately.
Taking up or down GI tubing and connections and setting aside for reuse after cleaning or issue in credit for the following sizes, complete all as specified and directed.
15 mm bore pipe.
20 mm bore pipe.
25 mm bore pipe.
40 mm bore pipe.
50 mm bore pipe.
80 mm bore pipe.
100 mm bore pipe.
Cleaning of old serviceable GI tubing for re-fixing and connecting obtained from item 13.01 to 13.03 in old or new position (wall, ceiling, floor or trenches) for the following sizes, complete all as specified and directed. Note:- (i) Rate for cutting and threading of GI pipe is deemed to be included in quoted rates (ii) Rates for new GI fittings (socket, elbow, bend, union, nipples, reducers etc ) required for fixing of pipe is deemed to be included in quoted rates. (iii) Excavation and earth work shall be measured and paid separately.
15 mm bore pipe.
20 mm bore pipe.
25 mm bore pipe.
Supply and fixing of steel water tubing galvanized iron medium grade laid in trenches including all fittings such as bends. Elbow, tees, short piece, connections , back nuts, diminishing pieces, caps plugs and unions etc for the following sizes, complete all as specified and directed . Note:- Excavation and earth work shall be measured and paid seperately.
15 mm bore pipe.
20 mm bore pipe.
25 mm bore pipe.
40 mm bore pipe.
50 mm bore pipe.
80 mm bore pipe.
100 mm bore pipe.
Supply and fixing in replacement of cast iron sluice valve class PN-1.6 conforming to IS 14846-2000 with flanged ends 150 mm nominal bore ISI marked complete with stainless steel spindle and cast iron hand wheel including rubber /fiber board gasket nuts, bolt, washers etc, including necessary excavation, returning and filling complete all as specified and directed . MAKE :- SANT/KIRLOSKER/UPDHAYA/BIR.
All as per srl item No 16 above but sluice valve 100 mm nominal bore complete all as specified and directed.
All as per srl item No 16 above but sluice valve 80 mm nominal bore complete all as specified and directed.
Supply and fixing in replacement of gun metal globe or gate valve (class-1) with iron wheel head screwed both ends for iron pipes or unions conforming to IS-778 complete for the following sizes including necessary excavation, returning filling and removal complete all as specified and directed.
15 mm bore pipe.
20 mm bore pipe.
25 mm bore pipe.
40 mm bore pipe.
50 mm bore pipe.
80 mm bore pipe.
100 mm bore pipe.
S&F in replacement of Cast Iron Air release Valves 100mm nominal bore with single air Outlets, conforming to IS 14845-2000, duly ISI marked with nut, bolts, washers and rubber gasket fixing up in CI/DI on Water supply mains including necessary excavation, returning and filling complete all as specified and directed.
All as per srl item No 20 above but Air release Valve 80 mm nominal bore complete all as specified and directed.
S&F in replacement of Cast Iron foot valve 80mm nominal bore , conforming to IS 4036, duly ISI marked with nut, bolts, washers and rubber gasket and fixing up in CI/DI on Water supply mains and underground sump complete all as specified and directed.
S&F in replacement of Cast Iron foot valve 100mm nominal bore , conforming to IS 4036, duly ISI marked with nut, bolts, washers and rubber gasket and fixing up in CI/DI on Water supply mains and underground sump complete all as specified and directed.
S&F in replacement of Cast Iron non return/reflex valve 150mm nominal bore with by pass arrangement duly ISI marked with nut, bolts, washers and fixing up in CI/DI on Water supply mains complete all as specified and directed.
Supply and fixing in replacement of cast iron/DI fitting for sockted/ flanged pipes up to 150 mm bore such as bends, tapers, tee pieces (single & double branch) any type and angle tapers any type (straight, bends, increasing, decreasing or double socket etc) Tee branch single branch, 'Y' junction, double branch cross collars caps and plugs up to 150 mm bore complete all as specified and directed.
M&L for Cutting and threading Existing steel tubing of dia 40 to 50mm bore for alteration or additions (each cut measured) in any condition complete all as specified and directed. Note:- One cutting of GI pipe and threading on both pieces of pipe after cutting shall be measured as each job.
M&L for Cutting and threading Existing steel tubing of dia 80 to 100mm bore for alteration or additions (each cut measured) in any condition complete all as specified and directed. Note:- One cutting of GI pipe and threading on both pieces of pipe after cutting shall be measured as each job.
M&L for Drilling and tapping cast iron water mains (in position) for branch connections of the internal dia 15mm bore including all fittings complete all as specified and directed.
M&L for Drilling and tapping cast iron water mains (in position) for branch connections of the internal dia 20mm bore including all fittings complete all as specified and directed.
M&L for Drilling and tapping cast iron water mains (in position) for branch connections of the internal dia 25mm bore including all fittings complete all as specified and directed.
Supply & fixed in repairs straight plain brass ferrules (or connecting screw) of 15mm bore screwed both ends complete all as specified and directed.
Supply & fixed in repairs straight plain brass ferrules (or connecting screw) of 20mm bore screwed both ends complete all as specified and directed.
Supply & fixed in repairs straight plain brass ferrules (or connecting screw) of 25mm bore screwed both ends complete all as specified and directed.
Supply and fixing in replacement of 15 mm bib tabs standard PTMT type any colour high pressure screwed for iron pipe minimum weight 15 mm - 90 Grams compelete all as specified and directed.
M & L for preperation of old painted surfaces of steel/iron and applying one coat of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
M & L for preperation of old painted surfaces of sluice valve of any sizeand applying one coat of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
M & L for repair of valve pits with following complete all as specified and directed.
Demolition of brick masonry work built in cement mortar including all quoins, arches, pillars, or in any position (after staging) etc. and removal outside the MoD land distance exceeding 2.5Km but n.exc 3Km, complete all as specified and directed
Material and labour, brick work with fly ash bricks straight or curved on plan exceeding 6m mean radius, built in CM (1:6), complete all as specified and directed.
M & L for PCC 1:3:6 type B-0 (12.5 mm graded stone agg ) as in coping of vlave pits complete all as specified and directed.
Supply and fixing in replacement MS sheet cover 3mm thick, duly painted with two coats of black bituminous primer over a coat of red oxide primer, complete all as specified and as directed.
M&L for rendering 10mm thick in CM 1:6 on brick work, concrete surfaces at any height finished even and fair without using extra cement of , including taking down and removal outside the MoD land distance exceeding 2.5Km but n.exc 3Km complete all as specified and directed.
Supply and fixing in replacement of mild steel angle iron of any size including duly painted with two coats of black bituminous primer over a coat of red oxide primer , complete all as specified and directed.
Supply and fixing in replacement MS bend 80 mm dia 45 cm long dully bended and welded to required shape complete with flanged ends including jointing materials such as nuts,bolts,washers and gaskets etc complete all as specified and directed.
Material and labour for plain cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate, as in foundation filling and mass concrete, complete all as specified and directed.
Supply and fix in repair ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic vall screwed for iron pipe of 20mm bore (minimum weight 210 gms) complete all as specified and directed.
Supply and fix in repair GI union of size 25mm bore, complete all as specified and directed.
Supply and fix in repair GI union of size 20mm bore, complete all as specified and directed.
Supply and fix in repair GI nipple of size 25mm bore of length 100mm, complete all as specified and directed.
Supply and fix in repair GI nipple of size 20mm bore of length 100mm, complete all as specified and directed.
Supply and fix in repair GI nipple of size 15mm bore of length 100mm, complete all as specified and directed.
Supply and fix in repair GI reducer of size 25/20mm bore, complete all as specified and directed.
Supply and fix in repair GI reducer of size 20/15mm bore, complete all as specified and directed.
Supply and fix in repair GI socket of size 25mm bore, complete all as specified and directed.
Supply and fix in repair GI socket of size 20mm bore, complete all as specified and directed.
Supply and fix in repair GI socket of size 15mm bore, complete all as specified and directed.
Material and labour for attending the complaint of water supply for leakage, pipe broken, line block, cleaning of pipe, float valve and all related to water supply find out the problems and rectified the same day without affective the services, complete all as specified and directed. Note:- (i) Complaint should be attend immediately in one hour and to be rectified within 04 hours. (ii) Complaint attended by specific knowledgeable person of water supply. (iii) Contractor shall provide all tools & Plants as required, (iv) In case of failure to rectify the complaints within 04 hours a panel recovery shall be made from contractor's due @Rs. 200/- per hours for each complaints.
Supply and fixing in replacement for run lead joints suitable for 150 mm bore DI pipe and fittings including jointing material such as lead, spun yarn etc complete all as specified and directed .
Supply and fixing in replacement for run lead joints suitable for 100 mm bore DI pipe and fittings including jointing material such as lead, spun yarn etc complete all as specified and directed .
Supply and fixing in replacement for run lead joints suitable for 80 mm bore DI pipe and fittings including jointing material such as lead, spun yarn etc complete all as specified and directed .
Supply and fixing in replacement for rubber gasket joint for 150mm dia pipe complete all as specified and directed .
Supply and fixing in replacement for rubber gasket joint for 100mm dia pipe complete all as specified and directed .
Supply and fixing in replacement for rubber gasket joint for 80mm dia pipe complete all as specified and directed .
Note:- (i) The tenderer are advice to visit the site before quoting their rates with prior approval of Engineer-in-Charge i.e. AGE E/M. (ii) The liability of contractor that all the repaired/serviced equipments should be made functional for 2 years from date of commencement. (iii) Please note that all the above activity included in quoted rates by the tenderer.
Note:- Amount of credit of Rs. 197167.00 for retrieved materials is mentioned in Schedule of Credit of tender documents in pdf form which will be deducted offline while acceptance of tender.
Arun enterprises
SANJEEV ENTERPRISES
Bharat Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .