Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.9 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹5.1 L+₹18,555 (3.77%)Rejected-Finance | 2 | Rejected-Finance Other than lowset | |
| 3 | 3₹5.7 L+₹79,776 (16.2%)Rejected-Finance H NO 01 MADINA BAGH MEHJOOR NAGAR NEAR HOTEL RAFADA SRINAGAR 190015 J K | BUDGAM | JAMMU AND KASHMIR | 190015 | 3 | Rejected-Finance Other than lowset | |
| 4 | 4₹5.8 L+₹89,871 (18.2%)Rejected-Finance 13 P N DOGRA MARKET GOLE MARKET UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | 4 | Rejected-Finance Other than lowset |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
13 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (I) 873 EWS
Garrison Engineer (Indep) 873 Engineer Works Section PIN 913 873 C/O 56 APO
REPAIR / MAINT OF EXTERNAL ELECTRIC SUPPLY WORKS AND OTHER CONNECTED ITEMS OF RR UNITS DHARMUND AND 11 SECT UNDER GE (I) 873 EWS
2021_MES_450805_1
NIT-22 of 21-22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Bhaderwah
As per NIT
7 documents required · 7 mandatory
₹500
GE (I) 873 EWS
₹20,000
Yes
17 Jul 2021
11 Jun 2021
16 Jul 2021
11 Jun 2021
13 Jul 2021
29 Jun 2021
60 days
Amount
Excavating in trenches, not exceeding 1.5metre wide and not exceeding 1.5metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick any type of soil, complete all as specified and directed.
Removing excavated soils to a distance exceeding 50m but not exceeding 100m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Cement concrete type C-2 1:3:6 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed.
Cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, drilling holes for bolts, in any shape or size as indicated or directed and also inclusive of two coats of aluminium paint over one coat of red oxide primer including dismantling / taking down old unserviceable structural steel all as specified and as directed.
Aluminium conductor steel reinforced (ACSR) including binding to insulator with suitable size of binding wire and size of conductor Weasel (6/1 x 2.59 mm), Squirrel (6/1 x 2.11mm) or Ferret (6/1 x 3.00 mm) including taking down old conductor complete, all as specified and as directed.
Pin type porcelain vitreous white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 150mm height, 150mm dia for 11000 volt complete including taking down old unserviceable insulator complete all as specified and directed.
Pin type porcelain vitreous white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 100mm height, 65mm dia for 1100 volt complete including taking down old unserviceable insulator complete all as specified and directed.
Disc type insulator porcelain vitreous white, brown or green 145mm high and 255mm dia ball and socket type, single disc assembly for tension with tension clamp for conductor of working pressure 11000 volts including taking down old unserviceable insulator complete all as specified and directed.
Shackle type insulator porcelain vitreous white, brown or green 100mm high and 115mm dia for conductor of working pressure 1100 volts including galvanised mild steel straps of 31x5mm size, 14mm dia insulator bolts, washers and nuts including taking down old unserviceable insulator complete all as specified and directed.
Stay Assembly using stay rod of 20mm dia complete accessories as shown in Electrical Plate No 1 of SSR 2009 Part-I such as loop type insulator, porcelain, vitreous white/ brown or green, large size with overall dimensions 140x90mm clearance of hole 16mm, stay wire of size 7/4mm etc., complete all as specified (Earth work and PCC shall be measured and paid for separately)
Switch Air break, gang operated (GOD) with 15 Nos insulators in replacement, outdoor type, Three Pole mechanically operated, suitable for vertical installation, Single break, provided with locking arrangements consisting of MS channel, HT Post type insulator copper alloy, high Pressure, Assembly operating rod 25 mm dia GI pipe medium grade for operating from 1.2 metre above Ground Level with locking arrangement complete confirming to IS-1318 of 1972 rated voltage 11 KV and for current rating 400 Amps including taking down old GOD complete all as specified and directed.
Lightning arrestor expulsion type, consisting of multiple spark gaps in series with one or more non-linear resistor to limit voltage surge on AC power circuit to interrupt power flow current suitable for outdoor installation and exposed direct to sun with ambient temperature between (-) 10° C to (+) 50° C suitable for surge discharge capacity 65 KA, 11000 Volts grade conforming to IS-4350 complete with all fittings including taking down old unserviceable arrestor, complete all as specified and directed.
Cutting and trimming of trees and branches to clear the over head line in the arc of HT/LT over head line feeders and removal of the trimmed branches of trees complete all as specified and directed. Notes : 1. Any ACSR conductor damaged during the cuttings of trees / branches shall be repaired and jointed / fixed by the contractor, to the entire satisfaction of Engr-in-Charge, without any extra cost and nothing extra shall be admissible from the department on this account what-so-ever. 2. The cutting / trimming of tree branches shall be done to at least 2.00 metre radius of OH line. 3. The unit of measurement is 'SPAN' i.e. distance covered between two poles.
Restringing / Restretching / Tightening of old ACSR conductor of any size and make on HT / LT Poles by disconnecting and removing from insulators including providing necessary binding wire and jumpering after proper stringing all as directed.
Painting of steel tubular pole any type with cross arms with one coat of aluminium paint after preparation of surfaces of pole / cross arms by scrapping of old paint, cleaning of all rusted surface and painting upto 1.5metre above PCC coping in black and white strips 05 Nos of 30cms each starting from the bottom of the pole and two coats epoxy based paint aluminium grade finish to the remaining external surface of pole and cross arms structure over one coat of primer and marking of MES No complete all as specified and as directed.
MCCB 350 Amps, breaking capacity 36 KA, FP, 415V (adjustable thermal and magnetic release) complete all as specified and as directed.
MCCB 250 Amps, breaking capacity 36 KA, FP, 415V (microprocessor release) complete all as specified and as directed.
MCCB 200 Amps, breaking capacity 36 KA, FP, 415V (adjustable thermal and magnetic release) in replacement complete all as specified and as directed.
MCCB 160 Amps, breaking capacity 36 KA, FP, 415V (adjustable thermal and magnetic release) in replacement complete all as specified and as directed.
MCCB 100 Amps, breaking capacity 16 KA, FP, 415V (adjustable thermal and magnetic release) in replacement complete all as specified and as directed.
MCCB 63 Amps, breaking capacity 16KA, FP, 415V (adjustable thermal and magnetic release) in replacement complete all as specified and as directed.
Street Light fitting 60 Watts LED made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening separate driver compartment with IP66 protection and impact resistance of IK07 with 10KV built-in surge protection device including taking down old unserviceable Street Light Fitting all as specified and as directed. Make : Crompton 'Nexus+' Cat Part No LSTP-60-CDL or equivalent in Wipro / Philips / Havells
Flood Light luminaries fitting 100 Watts LED, energy saving, environmental friendly long life, exclusive innovative die cast aluminium IP66 including taking down old unserviceable Street Light Fitting all as specified and as directed. Make : Havells Cat Part No. JETAIRISFLS100WLED757APWBLTG or equivalent in Wipro / Philips / Crompton
A unique LED flood light luminaire 20 W, 230 Volts, new generation energy saving and environmental friendly long life versatile pressure die-cast aluminium roadway luminaire, IP 65 protection with high power LEDs as light source and electronic driver, including making making connection with PVC copper conductor of suitable size, complete all as directed. Make : Havells Cat Part No. LHEECNP7IB6K020 or techno comercially equivalent in Crompton /Wipro / Philips
A unique LED flood light luminaire 30 W, 230 Volts, new generation energy saving and environmental friendly long life versatile pressure die-cast aluminium roadway luminaire, IP 65 protection with high power LEDs as light source and electronic driver, including making making connection with PVC copper conductor of suitable size, complete all as directed. Make : Havells Cat Part No. LHEECNP7IB6K030 or techno comercially equivalent in Crompton /Wipro / Philips
Decorative Gate Light fiiting made up of high grade unbreakable polycarboante material suitable for and including 7 W LED Lamp B-22 base complete all as directed. Make : Crompton /Wipro / Philips / Havells
PVC copper conductor cable 2.5sqmm three core fixed as in connection to street light on poles from DB, complete all as directed.
Sheet metal enclosure factory made single door for DB 240 volts with 200 Amps rated bus bar SPN 02 Way, in replacement complete all as specified and as directed.
Cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 - 120 Sqmm complete in repairs all as specified and as directed.
Cable jointing kit for 1.1 KV (earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 95 - 120 Sqmm in repairs complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 95 Sqmm 3.5 core on wall including taking down old cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 70 Sqmm 3.5 core on wall including taking down old cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 50 Sqmm 3.5 core on wall including taking down old cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 35 Sqmm 3.5 core on wall including taking down old cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 25 Sqmm 4 core on wall including taking down old cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 16 Sqmm 4 core on wall including taking down old cable, complete all as specified and as directed.
XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 16 Sqmm 2 core on wall including taking down old cable, complete all as specified and as directed.
Sand cushioning to underground cables using new dry river sand laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete, punned to 18cm, complete all as specified and directed Note : Punned thickness of 18cms shall be measured for payment.
Supply and laying brick covering with width equal to length of bricks as mechanical protection to underground cable using old size sub class 'B' bricks, laid flat size 230mm x 115mm x 75 mm with width of brick perpendicular to length of cable, all as specified and as directed.
Laying only serviceable bricks as mechanical protection to underground cable with width equal to length of bricks, width of brick perpendicular to length of cable, all as specified and as directed.
Steel pipe galvanised light grade, 40 mm bore laid in trenches or under ground/floor or road of fixed with pole for protection of cable including GI clamps with bolts nuts and washers complete all as specified and directed.
Material and labour for disconnecting electrical connection removing the defective transformer, loading and transporting to workshop from site and vice-versa including disconnecting and rewinding of 11/0.433KV, 63 KVA to 250KVA, Three Phase, Four Wire, 50Hz vector group Dyn 11 transformer with paper insulated copper winding wire / strip as per original data on HV (delta connection) and LV (Star Connection) 7 tapping brought on HV side for tap charger to change + 2.5%, 5%, 7.5% by means of manually operated Off-Load tap changing gear complete rewinding of HV on three limbs providing insulation material like spares, wooden blocks, cotton tape etc. and re-conditioning three limbs complete opening, replacement of cock sheet packing, vent diaphragm replacement of LT terminal plate, breather, filling of new transformer oil for top up with existing oil after proper filtration upto level of 50 KV dielectric strength and testing of transformer at factory and site after connecting all electrical connection in full load all as directed.
Notes :- 1. Spares required will be measured and paid separately under appropriate item. 2. The Quoted Rate shall be deemed to include transportation, electrical connections, Testing & Commissioning.
Supply only following Items / Spares required for transformers :-
(a) HT coil of suitable gauge of paper insulated copper winding wire for any capacity of transformer
(b) LT coils of suitable guage of paper insulated copper winding wire for any capacity of transformer
(c) Gasket suitable for 63 to 250 KVA Transformer
(d) LT Terminal Plate for outgoing connections
(e) Breather for Transformer of capacity 63 KVA to 315 KVA
Supply, filling and top up with new Transformer Oil of dielectric strength more than 50 KV at 2.5mm gap confirming to IS : 335-1993 complete all as specified and as directed. Make : APAR Oils / Savita
Dehydration of transformer oil by using filtration plant of suitable capacity and removing the moisture / dust till obtaining the oil dielectric strength 45 KV at 2.5mm gap and above for various transformer / voltage stabilizer of any size located at different substations, complete all as specified & directed.
ON LOAD Change Over Switch 415 volt in sheet metal enclosure Three Pole of capacity 63 Amps complete all as specified and directed
ON LOAD Change Over Switch 415 volt in sheet metal enclosure Four Pole of capacity 100 Amps complete all as specified and directed
Supply & fising in replacement, bus bar panel, size 0.80m x 0.40m x0.40m, Kiosk outdoor type, CPRI type tested, LT 440 Volts, 50 Hz, TP, 4 wire supply, Floor mounted factory fabricated weather and vermin proof made out of 1.4 mm thick MS Sheet CRCA Sheet on angle iron 30 x 30 x 4mm with front opening door, handle type locking arrangement powder coated internally and externally shall have channel base of appropriate size and mounted on PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 Type C-2 including earth work complete with bus bar chamber comprising 4 Nos aluminium strip bus bars PVC insulated of rating 200 Amp, PVC sheathed with colour coding, complete all as specified and directed.
Supply and fixing , testing & Commissioning of LT panel in replacement KISOK outdoor type CPRI approved, factory made fabircated weather and vermin proof class IP 54 made out of 3.15mm thick CRCA sheet on angle iron 40x40x6mm frame of suitable size with copper bus bars 4strps of 200 Amp PVC insulated in red, yellow, blue and black colors mounted on cast resin insulators, double door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, duly powder coating up to 50 to 60 micron layer after phosphating process internally and externally complete over a coat of red oxide primer, including PCC M-1:2:4 nominal mix type B-1 using 20mm graded aggregate as in raised platform ,complete all as specified & directed. The LT panel shall comprise the following fitments/equipments :- INCOMER :- (a) (A) Incoming (i) MCCB 160 Amps, breaking capacity 25 KA, FP, 415 Volts (adjustable thermal and magnetic release) – 01 No
(B) Outgoing (i) MCCB 100 Amps, breaking capacity 16 KA, FP, 415 Volts (adjustable thermal and magnetic release) – 01 Nso (ii) MCCB 63 Amps, breaking capacity 16 KA, FP, 415 Volts (adjustable thermal and magnetic release) – 02 No (iii) Multifunctional digital panel meter with LCD display flush mounting type of size 96x96mm, accuracy class 1, including suitable CTs with secondry current 5A, with display volt, Amp, Frequency, KWH- 01 No (iv) Lock pedestal (v) All accessories pre-wired with suitable size PVC insulated copper conductor cables for control wiring and PVC insulated copper strips of appropriate size for power circuits as per standard engineering practice.
Earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick buried directly to ground vertically to a depth not less than 2.25 Mtr below the ground level with top edge of earth plate not less than 1.65 Mtr below normal ground level connected to GI strip 32 x 6 mm size and earthing lead protected with 50 mm bore GI pipe, light grade, filling around with charcoal dust and salt including excavation, returning, filling of earth and disposal of surplus soil to a distance not exceeding 50 mtr and connected to GI strip by means of GI nuts, bolts and washers strip connected to earth plate including chamber PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate in concrete pit pre-cast RCC 40 mm thick reinforced with 6 mm dia round at 75 mm C/C both way with 12 mm dia mild steel plain bar lifting handle 2 Nos funnel with wire mesh 20 mm dia GI pipe light grade watering pipe and frame work complete all as shown in electrical plate No. 3 of SSR Part-I 2009 including testing on completion complete all as specified and as directed.
Galvanised Iron earthing strip 32 x 6 mm from earth test point to electrical equipment including taking down old unserviceable earthing strip complete all as specified and directed
SWASTIK TRADERS
M/S BALI CONSTRUCTIONS
VARDHMAN INTERNATIONAL
Bidder Name
M/S BALI CONSTRUCTIONS
SWASTIK TRADERS
VARDHMAN INTERNATIONAL
M/S Builders Indias
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .