Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹72.7 LAccepted-AOC H NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR 144 022 PUNJAB | JALANDHAR | JALANDHAR | PUNJAB | 144022 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹74.3 L+₹1.3 L (1.83%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹79.7 L+₹6.7 L (9.20%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹81.4 L+₹8.5 L (11.6%)Rejected-Finance 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹86.9 L+₹13.9 L (19.1%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹99.6 L
EMD Value
₹1.7 L
Closing Date
24 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col Jigar Trivedi, SM
HQ CWE (AF) Gurgaon, Old Palam Road, Delhi Cantt-10
ADDN/ALTN/IMPROVEMENT TO ELECTRIC POWER SUPPLY SYSTEM FROM MES POWER HOUSE TO RADAR/OPS ROOM AT 503SU, AF STN ARJANGARH UNDER GE(AF) GURGAON
2023_MES_605732_1
CWE/GGN/GT-10/2023-24
Open Tender
Electrical and Maintenance Works
Works
270 days
AF Stn Arjangarh
As per NIT
8 documents required · 8 mandatory
₹1,000
GE AF Gurgaon
₹1.7 L
Yes
19 Sept 2023
26 Jun 2023
31 Jul 2023
26 Jun 2023
24 Jul 2023
18 Jul 2023
26 Jun 2023 - 17 Jul 2023
Amount
Supply,laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade of size 3 core 150 sq mm Complete all as specified and directed.
Supply,laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade of size 3 core 95 sq mm Complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination, Cold shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 150 sq mm (02 Nos for Safal gate BSES RMU to SMQ power house and 02 Nos for SMQ power house to proposed RMU) Complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination, Cold shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 95 sq mm (02 Nos for proposed RMU to Radar proposed 4 Pole structure, 02 Nos for proposed RMU to Torpo two pole structure, 02 Nos for proposed RMU to termination point of NBC over head cable) Complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured, Al conductor cable of size 95 sq mm, Indoor/outdoor type Complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured, Al conductor cable of size 150 sq mm, Indoor/outdoor type Complete all as specified and directed.
Supply, installation, testing and commissioning of 11 kV (Outdoor type) one side extendable 4 way RMU (01 Incomer VCB + 03 Outgoing VCB) (VVVV+M) module floor mounted with internal copper busbars 3 phase, consisting of 630 Amps, 50 Hz 04 Nos fixed type motorised VCB alongwith insulated metering module, extendable type complete rapturing capacity 350MVA. All parts, busbars, connections of RMU should be enclosed in one tank to avoid multiple interconnections and sealed for life robotically welded non magnetic and non ferrite grade stainless steel tank grade 304 of minimum 2.5mm thick having IP 67 degree of protection filled with SF6 gas as insulation with leakage rate less than 0.1% per year tested as per IEC-62271-200, manometer as per IEC standard. The charging time of the motor shall be less than 15 second, making it suitable for rapid auto reclosing duty and safety shutters shall be provided to cover up the fixed high voltage contacts on bas bar and cable side when the bus trunk is moved to test/isolation position with all standard accessories and metering equipment and comprising of the following :- (a) Incomer 01 Nos VCB panel (i) 11kV, 630 Amp, 21 kA/3-sec, Draw-Out Vacuum Circuit Breaker as per IEC-62271-100 with roll on floor type 03 phase, having rapturing capacity 350 MVA. Motorized spring charging mechanism (230VAC) with internal spring charging handle for manual charging, associated push-buttons, anti-pumping feature, and associated Shunt Trip/Close Coils (24V DC). (ii) CT cast resin type (1x2 core or 2x1 core type copper wound dual ratio 100-50/1, 2.5VA, Class-5p10 for protection and class 1 for metering 2.5VA burden, short time rating 21KA for .1 Sec suitable for 11kV =06 Nos (03 Nos for protection and 03 Nos for metering) (iii) Potential Transformers, Draw-out type for easy maintenance, 11kV/rt3:110V/rt3, 50VA, Cl.0.5 with associated gun-type HRC fuses and MCBs for HT/LT isolation - Set of 03 Nos.
(viii) Control Equipment incl. :- (a) 01 x TNC Switch, (b) 01 x Local/Remote Switch, (c) 01 x Emergency Trip Push Button, (d) MCBs for AC (e) MCBs for DC (f) Heater Switch with Thermostat - 01no. (g) 3-pin socket with ON/OFF switch - 01no. (h) LED Lamp with ON/OFF switch - 01no. (ix) Flush mounted Auxillary Protection Relays incl:- (a) Trip Circuit Supervision Relay, (b) Master trip Relay, (c) PT Fuse failure relay. (d) DC Supervision Scheme (x) Suitable Disconnecting Link type terminal arrangement shall be provided for interfacing PS-Class CTs installed in the panel for achieving the required protection.
(iv) Metering Equipment including:- (a) 01 x Digital Voltmeter (Acc.Cl.0.5), 01 x Digital Ammeter (Acc.Cl.0.5), (b) 01no. Multi-Function-Meter (Acc.Cl.0.5) shall be provided with LCD display for measuring current, voltage, power, power-factor and energy-parameters, Total Harmonic Distortion and Max. Demand Indication, same shall be communicable on ModBus via RS485 port. (FOR EACH VCB OUTGOING PANEL) (v) LED Indications :- (FOR EACH VCB OUTGOING PANEL) (a) Breaker ON/OFF/TRIP/Spring-Charged, (b) R-Y-B, (c) DC Available LED with push-button (d) AC Supply Fail (e) Trip Circuit Healthy (vi) 06-Window Annunciator with Hooter to indicate following alarms :- (a) OC Trip, (b) EF Trip (c) Trip Circuit Failure, (d) Inter-Tripping Fault, (e) PT Fuse Failure The Annunciator will be complete with required Acknowledge/Test buttons as required (FOR EACH VCB OUTGOING PANEL)
(vii) Control Equipment incl. (FOR EACH VCB OUTGOING PANEL) :- (a) 01 x TNC Switch, (b) 01 x Local/Remote Switch, (c) 01 x Emergency Trip Push Button, (d) MCBs for AC (e) MCBs for DC (f) Heater Switch with Thermostat - 01 No. (g) 3-pin socket with ON/OFF switch - 01 No. (h) LED Lamp with ON/OFF switch - 01No. (viii) Flush mounted Auxillary Protection Relays incl (FOR EACH VCB OUTGOING PANEL) :- (a) Trip Circuit Supervision Relay, (b) Master trip Relay, (c) PT Fuse failure relay. (d) DC Supervision Scheme (ix) Suitable Disconnecting Link type terminal arrangement shall be provided for interfacing PS-Class CTs installed in the panel for achieving the required protection. (FOR EACH VCB OUTGOING PANEL) Note: (a) Pre-commissioning test shall be done by SEI from CE WC (b) Pre disptach inspection shall be carried out by the rep of Accepting Officer at manufacturer factory premised before dispatching to site. The rate quoted shall also include the cost of equipments used for testing during the inspections. (c) The cost of bus bar for interconnections of VCB's which shall be made of copper, electrolytic grade and of suitable rating deemed to be included in quoted rates. (d) The cost of first filling of SF6 fas for busbar deemed to be included in quoted rates.
M & L for Earthing to OH/Sub stn with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead GI earth strip 32 x 6 mm by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3 of MES Schedule pt-I 2020, GI earth lead wire protected by GI pipe 40 mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion (incl taking out old u/s earthing - 04 Nos) complete all as specified and directed. Note : Main earth lead beyond 7.5 meter shall measured and paid saperatly.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 x 6 mm galvanised iron strip complete all as specified and directed,
M& L for steel tubular pole, swaged, complete with cast iron base plate, finial taper plug, bolts, nuts, washer and screws including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to portion embedded in PCC including numbering of poles with two coats of synthetic enamel paints, type 410-SP-55 (11 meter long) including taking out old u/s existing pole complete all as specified and directed. (FOR FOUR POLE STRUCTURE)
M & L for cross arms made out of mild steel channel or angle section of reqd size and shape including clamp back plate with bolts, nuts, washers drilled for insulator bolts, welding, binding cold or hot in any shape or size as directed and painted with two coats of aluminum paint over a coat of red oxide primer after necessary preparation of surfaces incl taking down old existing cross arms complete all as specified and directed.
Material and labour for cement concrete in foundations, filling and mass concrete Type D2 1:4:8 (40 mm graded aggregate) incl form work complete all as specified and directed.
Material and labour for coping to poles with PCC Type B1, 1:2:4 (20mm graded aggregate incl form work complete all as specified and directed.
S&F in repair Lightning Arrester Expulsion type complete with all Fittings Transmission Class discharge capacity 65 KA suitable,for working pressure 11000 Volts and connection to earth with GI 32x6mm Strip, completing cirucit termination fixing complete all as specified and directed.
M& L in repair Switch Air Break Gang Operated for 11 KV grade, Triple Pole vertically mounted on insulator and fitted on steel frame , current rating 400 Amps, mechanically operated mechanism from Ground Level consisting of Operating Rod of GI Pipe 25mm bore (dia) ‘light grade’ of suitable Length worked From Ground Level and with Locking Arrangement Mild Steel Flat Iron Clamp 50x6mm including dismanting old unserviceable Switch Air Break of any description, complete all as specified and as directed and completing circuit
Taking down Old u/s expulsion fuse 11 KV any type complete all as specified and directed.
S&F Expulsion Fuse, Single Pole, Channel type/drop out type suitable as per Site requirement with Working Pressure 11 KV grade of capacity 50 to 100 Amps complete all as specified and as directed.
S&F in repair Aluminium Conductor Steel Reinforced (ACSR) (sizes as ordered) with permissible Sags, fixing on Electric Poles and binding to Insulators with Aluminium Binding Wire as in OH Conductors including stringing, tightening, etc., complete all as specified and as directed.
M&L for compression/crimping type sleeve joints above 10 mm dia for conductor wire overall for jointing conductors/jumper connections indlucing treatment with conducting jelly complete all as specified and directed.
S& F Danger notice plate of 1.6 mm thick mild steel sheet viterous enameled white with letter figures and conventional skull and bones in signal red colour and fix with MS clamp for HT size 25 x 20 cm incl taking out old u/s existing notice plate complete all as specified .
Material and labour HT cable route indicator made out of PCC post of 1:2:4 of size not less than 20 x 15 cm and one meter height with making embossing the following letters of size 100 mm in the PCC post "MES HT CABLE 11000 Volts, 185 SQ MM" including necessary excation and PCC 1:2:4 (30 x 30 x 30 CM) for embeding the ground.
(d) Multi function digital meter for current volatage power factor, KVA, KVAR, frequency KWHR and maximum demand recording and indications. (e) LED indicating lamps, breaker on, off spring chaged, trip circuit healthy, auto trp indicator RYB phase indication. (f ) Switch for closing /tripping off VCB. (g) Heater with switch , thermostat and illumination. (h) 01 Nos shunt trip coil and closing coil 24V DC. (j) Power pack unit , 24 volt DC with dry rechageable batteries complete. (k) Mechanical and Electrical interlocking with existing system as directed by GE. (l) Auxillary power supply system of panel complete with maintenance free lead acid battery mounted on 40x40x5mm MS angle iron rack and provide with connector etc complete in all respect with installed capacity 24 volts DC 2 Nos each of 12 volts 100 AH including battery charger all as per standard specification suitable for 2x24 volts battery with DC Amp meter, voltmeter, switches ON/OFF including connection upto panel. Note: (a) Pre-commissioning test shall be done by SEI from CE WC (b) Pre disptach inspection shall be carried out by the rep of Accepting Officer at manufacturer factory premised before dispatching to site. The rate quoted shall also include the cost of equipments used for testing during the inspections. (c) The cost of bus bar for interconnections of VCB's which shall be made of copper, electrolytic grade and of suitable rating deemed to be included in quoted rates. (d) The cost of first filling of SF6 fas for busbar deemed to be included in quoted rates.
Excavation in trenches in hard/dense soil not exc. 1.5 metre wide and n'exc. 1.50m deep for laying cables/pipes/poles and getting out complete all as specified and directed.
Excavation in trenches in hard/dense soil not exc. 1.5 metre wide and but exc. 1.50m deep for poles and getting out complete all as specified and directed.
Returning filling including spreading leveling watering and well ramming in layers not exc 25Cm in soft/ loose soil, complete all as specified and directed.
Removing excavated material in soft/ loose soil n'exc 50M and depositing where directed at a level n'exc1.5M above the starting point, complete all as specified and directed.
M&L for sand cushning to U/G cable in layers of 23cm thick( 8 Cm before laying the cable and 15Cm thick after laying the cable) in trenches including watering and consolidation, complete all as specified and directed.
Supply and laying un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300 mm x 180 mm x 40 mm complete all as specified and directed.
M & L for GI tubing (light grade) with all necessary fitting laid in trenches/under road crossing, or fixed on poles/walls/under floor etc complete all as specified and as directed for the following sizes:-
(a) 80 mm dia bore
(b) 100 mm dia bore
M & L for cutting of bituminous / PCC road of any description and in any position not other wise specifically provided ( for Laying of cables)
M & L for cement concrete in foundations , filling and ,mass concrete, Type B2 1:2:4 using 40 mm graded stone aggregate complete all as specified and directed.
Foundation Base and chainlink fencing for outdoor RMU
Surface dressing not exceeding 15 cm deep in Hard/Dense soil complete all as specified and as directed
M&L for 100 mm thick cement concrete (1:4:8) type D-2 with using 40 mm graded stone aggregates) as in sub base of flooing etc complete all as specified and as directed.
M & L for brick work using sub class ‘B’ bricks straight or curved on plan exceeding 6 Mtr mean radius built in cement mortar 1:6 complete all as specified and directed by Engineer in charge.
M&L for sand filling under floor or in foundations including watering and consolidation complete all as specified and as directed
M&L hard core broken bricks aggregate of guage n exc 63 mm deposit spread & levelled in layers n exc 15cm thick watered and rammed complete all as specified and directed
M&L for providing reinforced cement concrete nominal Mix type B1 1:2:4 using 20 mm graded stone aggregates as in Slabs supported on walls,beams and columns in floors,roofs, etc complete all as specified and as directed
M&L for MS TMT bars 10mm dia and over. Cut to length, bent to shape required, including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire ( annealed ) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engineer in Charge.
M & L for 15 mm thick cement plaster in cement mortar 1:4 on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed by Engineer in charge.
Material and labour for PCC (1:3:6) (20mm graded aggregate 75mm thick as in plinth protection surface finished even and fair without using extra cement including joints filled with bitumen mastic complete all as specified and directed by Engr-in-charge
Excavation in post holes (or similar holes) in hard/dense soil each n exc 0.5 cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.
M&L for PCC 1:3:6 , type C-2, using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete complete all as specified and dir.
M&L for MS work for fencing post and struts made from angle iron and flat iron in any section including cutting tops to shape, drilling holes and notching for fixing of wires etc confirming to Fe -290 or Fe -330 all as directed
Supply only chain link MS galvanised medium coated as per IS 4826 fencing 75mm x 75mm mesh & 3.50 mm dia of wire complete all as specified.
Fixing only chain link fencing incl line wires, any mesh, size and type to any type of standards, rails, straining bolts etc including provn of binding wire.
Supply and fixing for 4.00 mm dia galvanised medium coated as per IS 4826 steel wire as required for fixing chain link fencing etc all as specified and dir.
M&L for 5 to 10 mm dia mild steel screw bolts (machine made) with hexagonal or squre head at one end and screwed the other, or screwed both ends each screwed end to be fitted with washers etc all as directed.
M&L for preparation of new steel surfaces over 10 cm width or girth applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
S&F framed work (Fe 410-W(Gde-E-250) 'B' quality ) as in doors or gates of angle or other section with gusset plates, rails, braces, etc. complete, drilled for fixing of steel sheeting or other covering. Doors, etc to e prepated for hanging or sliding with and including either hook sand hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) ad hanging; also fastering and fixing complete.
Net Contract Sum will be after deducting Sch of Credit of Rs 23990.00
Commercial Traders
M/s GANJOO AND CO
M P TYAGI ENGINEERS AND CONTRACTORS
A B K Enterprises
Vijaypower Generators Limited
Ridhi engineers and builders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .