Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹84.6 LAccepted-AOC NO 19 KIRAMADAI 11ST STREET SURAMPATTI ERODE 638 009 | ERODE | TAMIL NADU | 638009 | L1 | Accepted-AOC The Single and Negotiated tenderer |
Tender Value
₹85.5 L
EMD Value
₹52,800
Closing Date
9 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Superintending Engineer/TNPHCL/North Circle
The Superintending Engineer/North Circle No.1and7, Inspector quarters, PGR Line, Behind CPO Building, Annadhanapatty, Linemedu, Salem - 636 006
Construction of New Rural Police Station Building with development works for Veppadai Police Station in Namakkal District. (Re-tender)
2021_TNPHC_212807_1
SE/NC/DB/336/2021
Open Tender
Civil Works
Lump-sum
240 days
Veppadai in Namakkal District
Refer Tender Documents
6 documents required · 6 mandatory
₹0
₹52,800
10 Dec 2021
2 Nov 2021
11 Nov 2021
2 Nov 2021
9 Nov 2021
2 Nov 2021
90 days
Amount
1.1 : Earth work excavation in all soils (including refilling) a. 0 to 2 mt.
1.3 : Earth work excavation in Soft disintegrated rock (including refilling) a. 0 to 2 mt.
1.5 : Earth work excavation for Open foundation (excluding refilling) a. 0 to 2 mt.
1.6 : Earth work excavation for Open foundation for drains (excluding refilling) width upto 1.25 m a. 0 to 2 mt.
2.6 : Supply and filling of 40 mm HBSJ
2.7 : Supply and filling of 20 mm HBSJ
7.2 : Supply and fixing of Bituminous filler pad, 20 mm tk. for expansion joint
13.1 : Filling with Excavated Earth
21.2 : Teak wood Wrought & Put up a. T.W. over 2 m & below 3 m
b. T.W. below 2 m length.
23.3 : S&F of Magnetic door catches
24 : Manufacturing & supply of steel windows (Weight basis)
25 : M.S.Holdfast
30 : Ellispattern
31 : Weathering couse
37.1 : White washing 3 coats (slaked)
39 : M.s Grills
40 : Painting - New "wood work"
41 : Painting - New "iron work"
46 : S & F 20 mm dia Alu. Hanger Rod
47 : S & F Alu Towel rail 75 cm long
48 : S & F 5 pin Coat stand
49 : S & F chromium plated 8 guage Picture Hook
50.4 : Providing Tree guard
52 : PVC Water supply (ASTM) a. 32 mm dia
b. 25 mm dia
53.3 :C.I steps (5 kg )
61.2 : Stoneware pipe dry condition a. 100 mm dia
62.1 : Stoneware bend b.150 mm dia S.W bend
62.2 : Stoneware Tee b.150 mm dia S.W Tee
Electrical arrangements 69 : 15 Amp. Power plug
72 : Box type Fibre Fan hook
73.1 : 6 way - D.B.
74 : Charges for fixing of "Fan"
76 : 8 SWG wire
77.3 : S&F of TV/Telephone line Socket
77.4 : S&F of 20mm dia PVC pipe for TV/Telephone line
78 : Earthing Station IS3043 (Type I)
81 : Meter cupboard
86 : Anti termite treatment
112.0 : S & F of Exhaust Fan 300 mm dia
ANNEXURE-I 2.1.1 : Supplying and filling with gravel
2.1.3 : Filling sand (using crushed stone sand)
3.1.1 : C.C.1:5:10 for Foundation & Basement (using crushed stone sand)
3.2.1: P.C.C. 1:2:4 for Foundation & Basement and other similar works (using crushed stone sand)
3.3.1: P.C.C. 1:8:16 using 20 mm broken brick jelly (using crushed stone sand)
3.8.1: P.C.C. 1:4:8 using 40 mm HBGS jelly (using crushed stone sand)
6.2.1 : Brick work in C.M. 1:5 (F& B) using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") (using crushed stone sand)
8.1.1.1 : Standardised concrete Mix M20 Grade Concrete (using crushed stone sand) a) In Foundation and basement
b) In Ground Floor
c) In First Floor
d) In Second Floor
9.2.1 : Brick work in C.M. 1:6 using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3")(using crushed stone sand) a. In Ground Floor/ Stilt floor
b. In First Floor
c. In Second floor
10.2.1 : Brick partition work in C.M. 1:4 using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") 114 mm tk (B.P.)(using crushed stone sand) a. In Foundation and basement
b. In Ground Floor/ Stilt floor
c. In First Floor
d. In Second Floor
11.2.1 : Brick work in C.M. 1:4 using chamber Burnt bricks of size 23 x 11.4 x 7.5 cm (9" x 4 1/2"x 3") 75 mm tk (B.P.)(using crushed stone sand) a. In Ground floor
b. In First floor
c. In Second floor
12.1.1 : Brick partition in C.M. 1:4 using country bricks of size 22 x11x5cm 50 mm thick (using crushed stone sand) a. In Ground floor
b. In First floor
14.1.I : Precast Cupboard slab 20mm tk. using standardised concrete mix M20 (Using crushed stone sand) a) In Ground Floor/ Stilt floor
b) In First Floor
c) In Second Floor
14.1.II : Precast Cupboard slab 40mm tk. using standardised concrete mix M20 (Using crushed stone sand) a) In Foundation and basement
b) In Ground Floor/ Stilt floor
c) In First Floor
d) In Second Floor
16.1.2 : Precast Jally Ventilator 50mm thick.Using standardised M20 grade concrete Mix withouty vibrating charges. (using crushed stone sand) a. In Ground Floor
18.1 : Formwork using M.S.Sheet a.For Column footings,plinth beam,Grade beam,Raftbeam,Raft slab etc.,
b.Plain surfaces such as Roof slab,floorslab,Beams,lintels,lofts,sill slab,staircase,portico slab and other similar works
c.For Square and rectangular columns and small quantities
d.Verticall wall
f.Curved surface
21.5.2 : Supply and fixing Solid UPVC door shutter with frame
21.6.1 : R.C.C.Door frames of size 100 x 75mm with one edge grooves size 't' x 20 mm M20 grade (with out vibrating charges) (using crushed stone sand) a. 900 x 2100mm
22.3.3 : T.W. frame & T.W styles & rails with BWR double leaf shutters for Cup board/ward robes including two coat enamel paint & one coat primer.
23.1 : TW styles & rails with 9mm thick BWR single leaf shutters with brass screws size of a. 900x2100 mm
23.2.1 : 4mm thick pin headed Glass panels with Aluminium beedings
23.5 : Supply & Fixing of MS door (for lockup door) a) MS door of size 1000 x 2100mm
24.1.1 : Supply & fixing of MS ventilator of size (lockup) b) MS ventilator of size 1200 x 600mm
26.1 : Flooring in C.C.1:5:10 (using crushed stone sand)
28.1 : Floor plastering in C.M. 1:4, 20 mm tk. (using crushed stone sand) Mixed with Super Plasticiser
29.8.1 : Glazed tiles using Grout (Tile Joint Filler) (using crushed stone sand)
29.9.1 :Floor ceramic tiles (Anti-skid) using Grout (Tile Joint Filler).(using crushed stone sand)
31.2.1 : Finshing the top of Terrace floor with one course of solar reflective Ceramic tiles with base concrete (using crushed stone sand)
33.1 : Plastering in C.M. 1:5, 12 mm tk. (using crushed stone sand) Mixed with Super Plasriciser
34.1: Plastering in C.M. 1:4, 12 mm tk.(using crushed stone sand) Mixed with Super Plasriciser
35.1.1 : Plastering 1:3, 12mm with WPC (using crushed stone sand)
35.1.2: Special Ceiling plastering in C.M. 1:3,10 mm tk.(using crushed stone sand)
36.1 : Cement mortar Border in C.M. 1:5, 12 mm tk (using crushed stone sand) including Super plasticizer a. 150 mm wide
b. 75 mm wide
c. 50 mm wide
38.6 : One coat white cement for new walls and other similar works.
38.7 : Plastic Emulsion PAINT including primer for outer
43.1 : Fabrication of Mild steel / RTS grills (without cement slurry) for all sizes of rods.
44.2 : Rain water harvesting using defunct borewell and providing perforated cover slab a). Providing pit
b) Augering 30cm dia
44.6 : PVC SWR 110 mm dia with ISI mark type- A for Rain water down fall pipe
50.2.1: Providing precast Kerb stone in C.C. 1:3:6, 450 x 300 x 150 mm (using crushed stone sand)
50.3.1 : Supply and planting avenue trees (using crushed stone sand)
50.5.1 : Supplying. Fabricating and erection of M.S Scheme Name board (using crushed stone sand)
50.6.1 : Precast slab 50 mm tk.in C.C. 1:3:6 with fibre (using crushed stone sand)
52.4 : 20mm dia PVC water supply ASTM pipe (fully consealed in walls)
53.4 : S&F of C.I Manhole cover 60 x 60 cm (50kg weight )
53.5 : Wash Hand Basin of size 550 x 400 mm
54.1.1 : S & F of 15mm dia half turn CP long body tap
54.2.1 : S & F of 15mm dia half turn CP short body tap
56.3.1.1 : S&F of Indian Water Closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR grade P' or "S' trap - G.F. (using crushed stone sand)
56.4.1.1 : S&F of Indian Water Closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR grade P' or "S' trap - Other than G.F. (using crushed stone sand)
57.1.1.1 : S & F of E.W.C (White) 500mm with PVC SWR grade "P" or "S" TRAP (using crushed stone sand)
58.3 : PVC SWR pipe (Soil line) with ISI mark - type 'B'. a. 110 mm dia.
b. 75 mm dia.
58.4 : Supplying, Laying & Concealing the 50mm dia PVC ( SWR) pipe with ISI mark type - 'B' with relevant specials.
58.5 : PVC(SWR) pipe with ISI mark - type 'A' for Ventilating shaft with cowl
59.2.1 : Gully Trap using Kiln burnt country bricks of size 23x11x7cm (using crushed stone sand)
60.1 : PVC Nahani trap (4way/2way) (using crushed stone sand)
61.3 : UPVC Non Pressure pipe of SN8 SDR 34 (S 16.5) as per IS 15328/2003 a. 110 mm UPVC Non Pressure pipe
b. 160 mm UPVC Non Pressure pipe
64.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990. a. Light point with ceiling rose
b. Light point without ceiling rose
c. Calling bell point with Buzzer/Calling bell
65.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Fan point.
66.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Staircase Light Point.
67.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Switch Board Itself.
68.2 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Convenient Places.
71.2 : Supplying and fixing of 32 AMPS Triple pole main switch.
75.1 : Supply and delivery of 48" (1200 mm) Fan with ISI mark with Eletronic Dimmer
77.2.1 : S & F of 20 amps DP plug & Socket in sheet enclosure with 32 A DP MCB in flush wall with earth connection(For AC Plug)(Legrand (MDS)/Hager (L&T) equalivalent /superior variety
77.5 : Run of 2 Wires of 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
77.6 : Run of 2 Wires of 4 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
77.7 : Run of 2 Wires of 2.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
79.2.1 : 3 Nos of 32 Amps - Fuse unit.
80.1 : 450 x 375 x 20mm thick TW plank
85.1 : Supply of G.I pipe 40mm dia 'B' Class 10 Kg/Cm2
87.1 : Supplying and delivery of Three phase ELCB/RCCB
98.3.1 : TW panelled single door shutter (with brass fittings) b. 900 x 2100mm. (Single leaf)
98.3.2 : TW Panelled door shutter with brass fittings (Double leaf) a. 1800 x 2100mm.
105.1 : Run off 4 x 4 Sq mm copper PVC insulated unsheathed single core cable for 3 phase EB service connection.
344.2 : S&F of Bevelled edge mirror 500 x 400 x 5.5mm
361.1 : Concrete designer tiles flooring
361.5.1 : Vitrified Tiles flooring (ivory) (using crushed stone sand)
367 : Providing wooden (melamine) polish for new wood
379.5.1 : Granite tiles flooring (Ruby red) using 2'x1', 10mm tk
448.2: Supply and fixing 32mm dia PVC Tee with end cap
799 : Two coat of OBD over one coat white cement for inner walls
832.5.2 : Supplying and fixing in position of UPVC Sliding window of casement type for all sizes
ANNEXURE-II A1: Supplying and fixing of 9 Watts LED bulbs
A2:Supplying and fixing of 12 Watts LED bulbs
A3: Supplying and fixing of 18W LED TUBE LIGHTS 4' long with necessary fittings and charges for assembling and fixing
A4: Supplying and fixing of water tight Bulk head fittings with guard suitable for 12W LED lamp
A5: Supplying and fixing of 25W LED street light fittings with light
A6: Supplying and fixing of following size of aluminium dye cast letters including labour charges for fixing in position cost and conveyance of all materials, scafolding, TW plugs, Screws metal paste and fixing charges etc. a) 9" dia Aluminium letters
b) 6"dia height letters
c) Emblems (30")
A7: Supplying and fixing of plastic Name board for all roos with ISI mark. a)18"X4"
A8: Supplying and delivery of 3.5 core 25 sqmm PVC armoured LTUG cable including cost of all materials etc.,
A9: Labour charges for fixing of 3.5 core 25 Sqmm PVC armouured LTUG cable in vertical wall (or) EB pole etc., ( Above Ground Level)
A10: Labour charges for laying of 3.5 core 25 Sqmm PVC armouured LTUG cable execluding Civil works etc., ( Below Ground Level)
A11: Supplying and fixing of Brass cable gland suitable for 3.5 core 25 Sqmm PVC armoured ALTUG cable including cost of all materials etc.,
A12: Supplying and fixing of 3 Nos. of 100 amps 500 volts grade porcelain fuse unit on suitable teakwood plank varnished to be fixed on the top of pole/EB street pole with necessary clamps including cost of materials etc.,
A13:Supplying and fixing of 24W LED 4000K 2 x 2 Square Type Recessed Fitting
A14: Supplying and fixing of Spot light fittings LED 5 Watts for bulb of best approved quality with ISI mark including labour charges
A15: Supplying and fixing of three phase Distribution board with 4 way TPN double door MCB DB 40 Amps 4 pole ELCB -1,6 amps to 32 amps SP MCB-12 nos, including all materials and labour charges etc
A16: Supplying and laying of following dia PVC pipe 10Kg/cm2 (Below GL ) a. 40mm dia
A17: Supplying and laying of following dia GI pipe 10Kg/cm2 (Above GL ) a. 40mm dia
A18: Supply & fixing of following dia PVC specials of best approved quality having ISI mark a) 40mm dia PVC Elbow
b) 40mm dia PVC Tee
c) 40mm dia PVC FTA
d) 40mm dia PVC MTA
A19: Supply & fixing of following dia GI specials of best approved quality having ISI mark . a) 40mm dia Non Return value
b) 40mm dia GI Elbow
c) 40mm dia Hex Nipple
d) 40mm dia Union
e) 40mm dia G.I Bend
A20: Supplying and fixing of following dia GM Wheel valve a. 40mm dia
A21: Drilling of 150mm dia vertical bores hard rock area to any required depth by dirct water mud circulation method using of contractor rig, tool, labour charges for drilling and water required etc., a) In over burden soil including labour charges for insertion on casing pipe line in bore well
b) Drilling of 150mm dia bore well in hard rock aras anywhere in Tamilnadu including transportion to the work site in hard rock areas and developing the borewells
A22: Supply , delivery and fixing of 160mm dia PVC heavy duty casing pipe of 6 Kg/cm² of approved quality with ISI mark confirming to Is specification asa per IS 12818/1992 for bore well etc complete.
A23: Supplying and fixing of 160mm dia end cap for bore well of best approved quality with ISI mark
A24: Supplying and fixing of 3 HP Submersible pumpset
A25: S & F of 3 Phase control panel board for submersible pumpset
A26: Supplying and fixing of 2.0HP, 2880 RPM, 415 Volts Single Phase Openwell submersible Monoblock pumpset
A27: Supplying and fixing of Single Phase DOL Control Panel Board for 2.0 HP Monoblock pumpset
A28: Supply and laying of 3 core x 4.0 sq.mm flat cable in a trench to be excavated at a depth of 0.75 metre covering the cable completely with PVC rigid conduit pipe 19mm/20mm heavy duty with ISI mark .
A29: Supply and laying of 3 core x2.5 sq.mm flat cable in a trench to be excavated at a depth of 0.75 metre covering the cable completely with PVC rigid conduit pipe 19mm/20mm heavy duty with ISI mark .
A30: Supply and clamping of 3 core x4 sq.mm Flat cable on post or on wall with MS Clamps
A31: Supply and clamping of 3 core x2.5 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps.
A32: Supplying and erection of UPVC Pipe used for commercial applications operate and designed to handle higher water pressure. a. 32mm dia
A33: Drilling following dia concrete core cutting holes upto 9" depth including all materials and labour charges etc., a)5" dia core cutting holes
A34: Labour charges for the erection of submersible pumpset in borewell/ openwell including fixing and jointing submersible cable with properclamps upto the starter to required depth i) Up to 5 HP
A35: Labour Charges for erection of Horizontal shaft, centrifugal pumpset (Coupled/Monoblock) in bore well/Open well including fixing of suction pipe and foot valve upto a maximum depth of 7 metres i) Up to 3 HP
A36: Supplying and erection of 16mm dia nylon rope
A37: Supplying and Godrej Navtal 6 levers-3 keys lock
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_252139.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .