Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.5 LAccepted-Finance 1153 SOUTH DHADKA BYPASS ROAD ASANSOL BARDHAMAN WEST BENGAL 713302 UDYAM WB 23 0002585 | PASCHIM BARDHAMAN | WEST BENGAL | 713302 | ₹37.5 L | L1 | Accepted-Finance Lowest Bidder |
| 2 | L2₹38.0 LRejected-Finance | ₹38.0 L | L2 | Rejected-Finance Quoted Rate Higher than L1 |
| 3 | L3₹38.6 LRejected-Finance 487 A 1 GOPAL MISHRA ROAD BEHALA KOLKATA 700034 | KOLKATA | WEST BENGAL | 700034 | ₹38.6 L | L3 | Rejected-Finance Quoted Rate Higher than L1 |
Tender Value
₹37.5 L
EMD Value
₹75,000
Closing Date
12 Mar 2026, 12:00 pmClosed
D.G_P and D deptt.kmc
Office of the D.G. / Planning aND Development Department The Kolkata Municipal Corporation.
Lighting arrangement with distribution circuit wiring works of the Booster Pumping Station in Ward no 100.
2026_KMC_1012208_1
KMC/D.G. (P-D)/E/068/2025-26
Open Tender
Electrical Work/ Equipment
KOLKATA
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹75,000
27 May 2026
25 Feb 2026
14 Mar 2026
25 Feb 2026
12 Mar 2026
25 Feb 2026
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection 63 A; FP L&T
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection 6-32 A; SP L&T
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment Make: L&T, 6 way
SUPPLYING OF FOLLOWING XLPE INSULATED ALUMINUM CONDUCTOR ARMORED CABLES OF 1.1KV GRADE AS PER IS 7098 (PART 1) 1988 WITH UP TO DATE AMENDMENTS Conductor cross section in Sq. mm. 10, 2 core
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint
Supplying swaged and welded steel tubular pole of following specifications as per IS 2317: 1980) 9m length, 154Kg, 410-SP-32
Supply of double arm bracket made of 40mm dia 1.0 meter long
Supply of single arm bracket made of 40mm dia 1.0 meter long
Erection of Single Steel tubular pole of length as given below with/ without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly Upto 9.0 mtr. Size 0.6x0.6x1.70 mts
Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint i) 1st coat of aluminium paint over 1 coat of RO priming
Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint (ii) 2nd coat of aluminium paint over 1st coat
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an verage depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe
Excavation of soil for installation of Earth Electrode and filling & ramming for Soft soil.
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 25mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required 3 x 56/0.3 (4 sqmm) + 2 x 36/0.3 (2.5 sqmm) ECC
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
Supply and fixing of greenline V2 street light (115 Watt) complete with all accessories to be fixed /projected from the wall of the building or on pole incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. Make : Crompton, 120 watt
M.S. works in framed gratings of window etc.made of round or square bars and frame work or M.S. flats (with the bars securely fixed to the flat bar frame) with or without intermediate flat bar stiffener and fixed with necessary screws etc. complete, as directed. In ground floor.
Supply TMC501 Conventional industrial batten Philips LED tube, model no : TMC 501 P 2xT-LED 22W P3242 with 2nos Mas LEDtube 1200mm 18W865 T8 I - 2100 lm including necessary connection.
Supply and fixing of EnduraLED Bulkhead Pressure Die cast housing LED bulkhead with IP66 Protection and IK09 impact resistance suitable for surface and wall mounting applications on ceiling fifling on wall /ceiling by screws etc. Make: Crompton, 10 watt LED
Supplying of approved make wall fan oscillating type with base, blades, guard, speed regulator etc. AC 230- 250 volts. 450mm sweep
Supplying of approved make Pedestal fan oscillating type with base, blades, guard, speed regulator etc. AC 230-250 volts. 450 mm sweep
Supplying of approved make exhaust fan heavy duty with mounting frame, blades AC 230-250. 300mm sweep RPM 900 / 1400 (12”)
Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter 30 cm (12")
Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/ Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works; 12Module
Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required
Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Brand approved by EIC), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 4 nos. 16 A, 3 pin Modular type plug socket with 4 nos. 16A Modular type switch (Brand approved by EIC), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply and installation of Polyvinylidene Fluoride coated Aluminium Composite Panel board (3mm) of Aludecor / Alstone size (as per drawing)to be made such a manner that it can be opened towards up direction for taking maintenance.
Steel Letter: Supplying, polishing,fitting and fixing 1.00mm thick 304 grade laser cutting Stainless Steel 3D letter.The letter should be fixed by suitable nuts,bolts,washer and fastener including all materials,S.S. welding,labour,Tool & Plants,electricity etc as required to complete the job.Supply & fixing 12V DC 2 Wt White Sumsung make 3 dot LED Module and Power supply and electric wiring.
LED Electronic Signage Board: Supply & Fixing LED screen P10Green,Body material Aluminum including 2 year guarantee along with all other accessories for outdoor installation.
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run
Supply and Fixing of 2 mm Polyvinyl glow sign board made of 22 SWG GI sheet box with 1”X1” aluminum channel for fixing the vinyl board after necessary cutting the letter as required & s\f LED tube light fittings along with all accessories
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment
60 KVAr, 415V, 3Ph, 50Hz, indoor type LT APFC Capacitor Panel
Supply Delivery and installation of ABC Powder type fire extinguishers (stored pressure) HSN code-84241000 conforming to IS:15683 and complete in all respect as per direction of EIC 06 Kg with ISI marked Mono Ammonium Phosphate base ABC power conforming to IS:14609 and ressurized with nitrogen gas. Suitable for operating between (-)30ºC to (+)55ºC. Fire rating -2A & 21B
Supply, Delivery and installation of Co2 type fire extinguishers: HSN code-84241000 03 Kg capacity with ISI marked Co2 type fire extinguisher squeeze grip type conforming to IS:15683:2006 made from seamless cylinder conforming to IS:7285 duly approved by Chief controller of explosive,NAgpur, fitted with ISI marked controller of explosive,Nagpur, fittet with ISI marked controlled valve conforming to IS:3224, discharge adopter and horn complete with initial gas charged with carrying handle and wall mounting bracket suitable for operating between (-)30ºC to (+)55ºC. Fire rating -13B.
Supply and delivery of Switch disconection fuse unit in open execution(Make: L&T/Havels/CGL/GE) of the following current rating: i) 315A, TPN
SUPPLYING OF FOLLOWING XLPE INSULATED ALUMINUM CONDUCTOR ARMORED CABLES OF 1.1KV GRADE AS PER IS 7098 (PART 1) 1988 WITH UP TO DATE AMENDMENTS. (Rate in Rs. Per Mtr) 3.5 CX 185 sq mm
Laying of one No. cable upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating 415 A L& K
Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991) Cu 4 bars, 415 V, 1000 A, 4 x (2x 80x5) mm dimention of sheet metal bos 500 X 150 MM
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC
Supplying and fixing polythene pipe complete with fittings as necy. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction) 32mm dia 3mm thick Polythene Pipe
Supplying and fixing sheet steel (16SWG) cable end box on TPN SFU enclosure with nuts bolts etc incl. powder coated painting. 63/125 A
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating 125 A L& K
Fixing only Voltmeter/Ammeter/Energy meter with screws & other fixing materials incl. making necessary holes and connections
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection L &K, 63 A, 4 P
Supply & delivery of 415 V, 50 Hz,3 Ph.AC Fully Automatic Star Delta Starter of Continuous duty in sheet steel enclosure of the following capacity (make:L&T/ABB/SCHNEIDER): d) 50 HP ( with Relay of Max Range in Amp 28-42)
Supply and delivery of Thermal overload relays (Make: L & T/ABB/Schneider/Simence/ GE/Minilec) of the following range: 28-46.5, MN12
Supply and delivery of Single Phase preventer Relay suitable 1243.00 for 415V, 6 wire, upto 20HP motor (Make: L & T/ABB/Schneider/ Simence/ Minilic/ GE).
Supply and delivery of direct rotary handel of MCCBs (Make: L & T/ABB/ Schneider/Simence/ GE) b) Direct rotary handle 100-160A, 415V
Supply of moving iron type analog AC ammeter (accuracy class 1.5), model-SMI-96 of following range 0 to 100A
Supply of 0 to 600V range moving iron type analog AC voltmeter (accuracy class 1.5), model-SMI-96
Supply of indoor tape insulated ring type low tension current transformer of following rating 100/5A 15VA, Cl 1.0
Supply of 22.5 mm dia LED indicating lamps
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Excavation of soil for installation of Earth Electrode and filling & ramming (a) For Soft Soil
Earthing with 80 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 No. 65 mm x 8 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 80 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
Extra for treatment of soil by using salt & charcoal or coke for plate electrode
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Hypochlorite dosing Unit: Manufacturing, supply, delivery and commissioning of 10 Kg cylindrical type with lead, Hypochlorite dosing unit of 1.5 Mtr. length including neck, also the lock and key arrangement. The cylinder must be of SS 304 material with full legs.
Supplying, Hoisting, fitting fixing approved typewater level indicator with copper float, guide pulley, wire boards etcas per standard specification and direction and satisfaction of EIC.
Sub Total
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.18 MB
Tendernotice_2.pdf
PDF • 0.77 MB
BOQ_2485699.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid