Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.1 LAccepted-AOC | L1 | Accepted-AOC OK | |
| 2 | L2₹13.9 L+₹44,276 (3.29%)Rejected-Finance UTARLAI KAWAS BARMER RAJASTHAN 344 001 | BARMER | RAJASTHAN | 344001 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹14.0 L+₹55,901 (4.15%)Rejected-Finance 12 53 CHOPASNI HOUSING BOARD JODHPUR 342 008 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342008 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹14.3 L+₹81,862 (6.08%)Rejected-Finance 2 EVEREST VIHAR PT T N MISHRA MARG NIRMAN NAGAR JAIPUR 302019 | JAIPUR | RAJASTHAN | 302019 | L4 | Rejected-Finance Other than lowest |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
9 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF UTARLAI
GE AF UTARLAI PB NO 11 BARMER RAJ PIN 344001
MAINTENANCE OF AIR FIELD LIGHTING SYSTEM AT AF STN UTARLAI
2021_MES_414652_1
8158/03/E8 dt 20 Jan 2021
Open Tender
Civil Works
Item Rate
180 days
GE AF UTARLAI
As per NIT
7 documents required · 7 mandatory
₹500
GE AF UTARLAI
₹28,000
20 Mar 2021
20 Jan 2021
10 Feb 2021
20 Jan 2021
9 Feb 2021
27 Jan 2021
60 days
Amount
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation/laying of cables etc. and n exc 10 Sq m on plan and getting out in soft / loose soil complete all as specified.
Returning, filling in excavated material (soil) including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified.
Removing excavated material to a distance n exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified.
Material and labour for clean dry tibba sand in trenches/ducts for cushoning to cable complete all as specified. (Punned thickness shall be measured & paid)
Supply and laying stone patti 40-50 mm thick, 25-30 cm wide abutting each other for cable protection complete all as specified.
Laying only stone patti obtained serviceable from item No. 7 here-in-after complete all as specified.
Labour for removing and taking out existing underground LT Cable from trenches or pole or underground in pipe duct carefully cleaning of the same for relaying incase of serviceable cable complete for the following sizes. all as specified.
185 Sqmm 3.5 core
95 Sqmm 3.5 core
70 Sqmm 3.5 core
25 Sqmm 3.5 core / 4 core
Relaying, Jointing and testing only under ground armoured cable LT XLPE insulated cable 1100 Volts PVC bedded aluminium conductor cable received from Item No. 7 here- in- before for following sizes complete all as directed by Engineer-in-Charge.
185 Sqmm 3.5 core
95 Sqmm 3.5 core
70 Sqmm 3.5 core
25 Sqmm 3.5 core / 4 core
Supply & Laying including Jointing and testing underground armoured cable LT XLPE insulated cable 1100 Volts PVC bedded galvanised steel strip or wire armoured electric LT UG cable heavy duty with multi stranded aluminium conductor laid in trenches / walls/ ducts passing through pipe cable of following size complete all as specified:-
185 Sqmm 3.5 core
95 Sqmm 3.5 core
70 Sqmm 3.5 core
25 Sqmm 4 core
Labour only for cleaning of duct any size under runway, taxi, road, pavement, hardstanding & including necessary machines required for cleaning all as directed by Engr-in-Charge.
Labour only for cleaning of TH Boxes and cable joints in order to improve the IR value of circuts complete all as directed by Engr-in-Charge
Labour only for Surface Dressing / Cleaning of Surrounding Area 4 sqm of each earth pit structure including removing of tree brances, small trees plants bushes etc complete all as directed by Engr-in-Charge.
Labour only for cleaning of Elevated lights and Insert lights located at various parts of airfield area complete.
Labour only for cleaning of Manholes and chambers of AFLS System loacated at various parts of airfield area complete.
Note for Item No. 10 to 14- The contractor will provide minimum 02 No Labour for attending the job included from srl item no. 10 to 14 .Contractor has to ensure to arrange minimum 02 No Labour throughout the contract period in one shift of 8 hours from 0900 hrs to 1700 hrs on working days, work on site will be performed as per direction of engineer in charge.
M & L for PCC 1:4:8 type C2 using 40 mm graded stone aggregate for foundation and including dismantling of PCC complete all as directed by Engineer-in-Charge.
M & L for PCC 1:3:6 type C1 using 20 mm graded stone aggregate for pedestal and including dismantling of PCC complete all as directed by Engineer-in-Charge.
M&L in replacement earthing complete as per electrical plate No. 3 of MES SSR Part-I with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less then 1.5 metre below normal ground level connected to and including galvanised iron or steel earth strip 32mmx6mm by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing strip shall be protected by galvanised iron or steel pipe 50 mm bore light grade and connected to continuous earth wire on pole / test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of included of excavation & earth work in any type of soil, charcoal, salt, funnel PCC pit and RCC cover complete all as specified & tested complete. Note . On testing after completion if the desired earth resistence is not obtained the earthing will be re carried out at no extra cost
Labour only for surface Dressing / Cleaning of Surrounding Area of Two Pole / Four Pole / Sub Stn structure including removing of tree brances, small trees plants bushes etc complete all as directed by Engr-in-Charge
Supply and fixing in replacement of cable route indicator cast iron of suitable size mounted on 40 x 40 x 3 mm angle iron with height of 1.5 metre along withcable trench including planting in ground with PCC complete all as specified and directed.by Engr-in-Charge.
S & F in replacement MCCB 160 Amps 36 KA make - cat part CM92109OON1OG in L&T or equivalent in Legrand,Siemens
S & F in replacement MCCB 100 Amps 36 KA make - cat part CM92108OOL1OG in L&T or equivalent in Legrand,Siemens
S & F end termination cable jointing kit, heat shrinkable for 1.1 KV grade XLPE cable complete with jointing material and accessories and testing after jointing of following sizes:-
25 to 50 sqmm 3.5 core
70 to 120 sqmm 3.5 core
150 to 185 sqmm 3.5 core
240 to 300 sqmm 3.5 core
S & F Straight through cable jointing kit, heat shrinkable for 1.1 KV grade XLPE cable complete with jointing material and accessories and testing after jointing of following sizes:-
25 to 50 sqmm 3.5 core
70 to 120 sqmm 3.5 core
150 to 185 sqmm 3.5 core
240 to 300 sqmm 3.5 core
M/S Tanisha Traders
M/s godara infratech and power industries
Rasam Engg Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .