| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.4 LAccepted-AOC 2 RC ENTERPRISES NEAR AGRASEN BHAWAN BHATAPARA CHHATTISGARH LINK ROAD BALODA BAZAR RAIPUR CHHATTISGARH 493118 | BALODA BAZAR | CHHATTISGARH | 493118 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹32.7 L+₹86,160 (2.70%)Rejected-AOC 47A C3 OLD DAMU NAGAR PULIAKULAM COIMBATORE 641 045 | COIMBATORE | COIMBATORE | TAMIL NADU | 641045 | L2 | Rejected-AOC rejected | |
| 3 | L3₹34.6 L+₹2.7 L (8.42%)Rejected-AOC NO 51 TOWN HALL 3RD STREET ARAKKONAM TAMIL NADU 631 001 | ARAKKONAM | RANIPET | TAMIL NADU | 631001 | L3 | Rejected-AOC rejected | |
| 4 | L4₹35.6 L+₹3.7 L (11.6%)Rejected-AOC | L4 | Rejected-AOC rejected | |
| 5 | L5₹36.0 L+₹4.1 L (12.9%)Rejected-AOC 1001 63 SHALIMAR GARDEN ISMAILGANJ NEAR INDIRA NAGAR SECTOR 08 CROSSING LUCKNOW 226016 | LUCKNOW | UTTAR PRADESH | 226016 | L5 | Rejected-AOC rejected |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
19 Mar 2022, 6:00 pmClosed
Commander Works Engineers Navy Chennai
Commander Works Engineers Navy Military Engineer Services Fort St George Rajaji Salai Chennai 600 009
87657 REPAIRS/MAINTENANCE TO PACKAGE AND DUCTABLE TYPE AC PLANTS OF VARIOUS CAPACITY UNDER GE(M) NAS ARAKKONAM
2022_MES_502249_3
CWE/NAVY/ARK/87657/E8 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
ARAKKONAM
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE MAINT ARAKKONAM
₹64,000
Yes
22 Apr 2022
12 Mar 2022
21 Mar 2022
12 Mar 2022
19 Mar 2022
12 Mar 2022
Amount
Material and labour for servicing and cleaning of condenser unit coil and cooling coil by caustic soda and flushing with plain water by pressure pump for removing complete trace of soda from the coil and fix in original position including testing all as specified and directed for the following capacity AC plants
5.5TR Capacity
8.5 TR Capacity
11.0 TR Capacity
17 TR Capacity
22 TR Capacity
Material and labour for servicing and cleaning of AHU and Duct unit (Supply air and return air ), removing any obstruction for AIR flow by air blower etc... and taking out all unwanted materials including cleaning Micro filter all as specified and directed by Engr -in-Charge for the following capacity AC plants :-
5.5 TR Capacity
8.5 TR Capacity
11 TR Capacity
17 TR Capacity
22 TR Capacity
Material and labour for renewal of damaged insulation of refrigeration system of various unit with 6mm thick nitro foam complete all as specified and directed
Material and labour for "V" belts including dismantling and taking out unserviceable/worn out "V" belts any type/model for the following sizes:- Makes:Fenner/Dunlop/V Grip
V- Belt of size A22
V- Belt of size A26
V- Belt of size A30
V- Belt of size A32
V- Belt of size A36
Supply and replace thermostatic expansion valve suitable for ductable split type AC 11 TR as per sample at site complete all as specified and directed. Make: Danfoss/ Sparlon or equivalent as approved by GE.
Material and labour for replacement of 32 Amps, 3 pole power contactor complete all as specified and directed. Make : L&T/ Siemens/Schneider/ABB
Material and labour for replacement of 25 Amps, 3 pole power contactor complete all as specified and directed. Make : L&T/ Siemens/Schneider/ABB
Material and labour for replacement of 3 pole power contactor 32 Amps, NC & No along with overload relay and timer complete all as specified and directed. Make : L&T/ Siemens/Schneider/ABB
Material and labour for replacement of 3 pole power contactor 25 Amps, NC & No alongwith overload relay and timer complete all as specified and directed. Make : L&T/ Siemens/ Schneider /ABB
Supply and Replace Fan Blade with complete assembly suitable for the following capacity plants all as specified & directed by Engr-in-Charge.
5.5 TR Capacity
8.5 TR Capacity
11 TR Capacity
17 TR Capacity
22 TR Capacity
Supply and fix in replacement canvas joint with opening and closing zip between AHU to Ducting joint complete all as specified and directed.
Material and Labour for taking down condenser fan motor of following capacity from outdoor unit original location for overhauling (i.e. greasing, oiling and varnishing to the starter , winding and replacing the worn out bearing, painting with two coats of synthetic enamel paint) and refixing to the original location including testing complete all as directed
3 phase,440V,50Hz,370W 930RPM
Single phase 230V,50 Hz 370W 940RPM
Single phase 230V, 50Hz 150W 920 RPM
Single phase 230V, 50 Hz 370W 900 RPM
Single phase 230V, 50Hz 250W 920 RPM
3 Phase 440V, 50 AC 370W 910RPM
Taking down the unserviceable fan motor and dismantling including taking out damaged/burnt out winding from motor, cleaning the slots with CTC and rewinding the same with new super enamelled copper winding wire of existing gauge and turns, oiling and greasing assembling and installing back into position and testing for satisfactory running complete for the following capacities, complete all as specified and as directed
3 phase,440V,50Hz,370W 930RPM
Single phase 230V,50 Hz 370W 940RPM
Single phase 230V, 50Hz 150W 920 RPM
Single phase 230V, 50 Hz 370W 900 RPM
Single phase 230V, 50Hz 250W 920 RPM
3 Phase 440V, 50 AC 370W 910RPM
Taking out existing old defected condenser fan motor, supply and fixing new condenser fan motor of the following capacity from outdoor unit from original location including testing complete all as specified and as directed
3 phase,440V,50Hz,370W 930RPM
Single phase 230V,50 Hz 370W 940RPM
Single phase 230V, 50Hz 150W 920 RPM
Single phase 230V, 50 Hz 370W 900 RPM
Single phase 230V, 50Hz 250W 920 RPM
3 Phase 440V, 50 AC 370W 910RPM
Material and labour to carryout the leak test on complete refrigeration system (indoor & outdoor unit) by charging the dry nitrogen gas & hold upto 24hrs and rectifying the leakage by bracing/welding/replacing the worn out parts of refrigerant line etc including vaccumising complete system of package type ductable Air-conditioning plant with double stage vacuum pump of upto 29inches of mercury pressure after repairs/replacement of compressor or repair in refrigeration system, including labour cost for charging the refrigerant gas for following plants all as specified and as directed
Note for Item No.15:- (i) New refrigerant gas shall be measured and paid separately as supply only under relevant items. However the T&P and labour charge deemed to include the unit rate quoted above. (ii)Once the gas charged in it, it should hold in the system minimum six months if any gas leaked from the system the contractor as to charge the gas upto required level on free of cost and No extra cost on this account shall be claimed. (iii) Leakage test on each complete unit shall be measured separately.
5.5 TR Capacity
8.5 TR Capacity
11 TR Capacity
17 TR Capacity
22 TR Capacity
Supply only R-22 refrigerant gas complete all as specified and as directed
Material and labour for taking down the burnout / defective scroll type compressor from the outdoor unit and replace with factory made compressor of same type, make and model including necessary welding/brazing, testing and commissioning complete all as specified and directed for the following capacity AC plants:- Make: Danfoss/Copeland/as per existing make in plant. Note for item No.17: Leak test, Vacuumising & Refrigerant gas shall be measured under relevant items.
5.5 TR Capacity
8.5 TR Capacity
11 TR Capacity
Material and labour for taking down the indoor unit blower motor from original location for overhauling including greasing, oiling and varnishing to the starter winding and painting with two coats of synthetic enamel paint and re-fixing to the original location including testing complete all as directed for the following capacity blower motors:- Notes:- Replacement of bearings will be measured and paid separately as supply only item. However labour cost for replacement of bearing shall be deemed to be included in the quoted rate.
3.7KW/5HP, 3 Phase, 440V, 50Hz, 1440 RPM
2.2KW/ 3HP, 3 Phase, 440V, 50 Hz, 1430 RPM
1.5KW/ 2HP, 3 Phase, 440V, 50Hz, 1420 RPM
0.75HP/ 0.55KW, 3 Phase, 440V, 1440 RPM
1/2HP, Single Phase, 230V, 50 Hz, 930 RPM
1/2HP, Single Phase, 230V, 50 Hz, 950 RPM
450W, Single Phase 230V, 50 Hz, 1440 RPM
Taking down the unserviceable burnt out motor of following capacity and dismantling including taking out damaged/burnt out winding from motor, cleaning the slots with CTC and rewinding the same with new super enamelled copper winding wire of existing gauge and turns, oiling and greasing, assembling and installing back into position and testing for satisfactory running complete all as specified and as directed
3.7KW/5HP, 3 Phase, 440V, 50Hz, 1440 RPM
2.2KW/ 3HP, 3 Phase, 440V, 50 Hz, 1430 RPM
1.5KW/ 2HP, 3 Phase, 440V, 50Hz, 1420 RPM
0.75HP/ 0.55KW, 3 Phase, 440V, 1440 RPM
1/2HP, Single Phase, 230V, 50 Hz, 930 RPM
1/2HP, Single Phase, 230V, 50 Hz, 950 RPM
450W, Single Phase 230V, 50 Hz, 1440 RPM
450W, Single Phase 230V, 50 Hz, 1350 RPM
Taking out existing old defected indoor blower motor, supply and fixing new indoor blower motor of indoor unit at their original location, of the following capacities including testing, complete all as specified and as directed.
3.7KW/5HP, 3 Phase, 440V, 50Hz, 1440 RPM
2.2KW/ 3HP, 3 Phase, 440V, 50 Hz, 1430 RPM
1.5KW/ 2HP, 3 Phase, 440V, 50Hz, 1420 RPM
0.75HP/ 0.55KW, 3 Phase, 440V, 1440 RPM
1/2HP, Single Phase, 230V, 50 Hz, 930 RPM
1/2HP, Single Phase, 230V, 50 Hz, 950 RPM
450W, Single Phase 230V, 50 Hz, 1440 RPM
450W, Single Phase 230V, 50 Hz, 1350 RPM
Supply and replace Micro processing unit PCB with Remote control set for the package type AC Plant of the following capacities, all as specified and directed by Engineer-In-Charge. Make: Blue star/Carrier.
5.5 TR Capacity
8.5 TR Capacity
11.0 TR Capacity
17.0 TR Capacity
22.0 TR Capacity
Supply only ball bearing of blower motor at Item No.18 here-in-before as per existing type/size for the package type AC plant complete all as specified and directed by Engineer-In-Charge. Make : SKF/NBC Note : Labour cost deemed to be included in rate quoted for Sl item No.18 here-in-before
Supply and fixing Drier/Strainer suitable for the following capacity package type AC unit including taking down old unserviceable one complete all as specified and directed by Engineer-In-Charge.
5.5 TR package type AC
8.5 TR package type AC
11 TR package type AC
17 TR package type AC
Supply and Replace washable Air Filter of 5 Microns for the following size suitable for ductable package type AC plants all as specified & directed by Engr-in-Charge.
Air Filter of size 1'8" x 1'8" (at 561)
Air Filter of size 1'6" x 1'10" (at Comcen Area)
Air Filter of size 2'5" x 1'6" (at Logistic Section)
Air Filter of size 2' x 2' (at Ops Area, ATC Tower, ATH 1st floor, Area)
Air Filter of size 1'6" x 7' (at WTS, SE Section, RAQ)
Air Filter of size 1' x 4' (at Magazine Telephone Exchange Bldg)
Supply and replace ammeter digital type (three digit) with suitable CTs 5A class I complete all specified and as directed. Makes: L&T Cat Part No.WDS 301FCA00 or equivalent as specified in PS.
Supply and replace damaged PVC drain pipe 32mm dia, complete all specified and as directed
Supply and replace single phase preventer unit 415V, 3Phase, complete all specified and as directed Make: Minilec VSP-3 or equivalent as specified in PS.
Supply and replace PVC connector 8.5 to 20Amps heavy duty 25mm, complete all specified and as directed
Material and labour for attend the complaints on the package type AC Plant, control panel, Micro processing unit of the system of any make / capacity as and when required Notes: (i) Spares if required shall be measured and paid under relevant items as supply only. (ii) The complaint should be attended on same day (iii) If the complaints are non rectified the contractor shall be levied penalty of Rs.300 per day per complaint till complete rectification of the complaint. Recovery will be effected from the RAR due to the Contractor.
Supply only MCCB adjustable type of following capacity/specification, 440V, 50Hz with extended terminal & spreader link complete all as specified and as directed.
MCCB 4 pole 36 KA 250 Amps
MCCB 4 pole 36 KA 200 Amps
MCCB 4 pole 36 KA 160 Amps
MCCB 4 pole 16 KA 63 Amps
MCCB 4 pole 16 KA 40 Amps
Supply only copper lugs suitable for wire upto 16 sqmm complete all as specified and as directed.
Supply only single core 1100 Volts grade FRLS cable PVC insulated (unsheathed) multi strand copper conductor of size 10 Sqmm complete all as specified and as directed.
All as per item No.33 here-in-before but single core 6sqmm complete all as specified and as directed.
All as per item No.33 here-in-before but single core 4sqmm complete all as specified and as directed.
Note for item no 31 to 35: Labour cost is deemed to be included in item 30
Supply and replace Capacitor of 10 Mfd/ 8 Mfd for condenser fan motor complete all as specified and directed Make / Model as per existing type.
Supply and Replace Bi metal relay with single phase protection for contactor mounting relay range 12.5 Amps to 20Amps complete all as specified and as specified & directed Make: Siemens/L&T/BCH
Supply and Replace Bi metal Relay with single phase protection for contactor mounting relay range 32 Amps complete all as specified and directed Make : Siemens/ L&T/ BCH
Supply and fix in replacement LP cut out switch complete all as specified and directed. Make : DAN FOSS/ IND FOSS
Supply and fix in replacement HP cut out switch complete all as specified and directed. Make : DAN FOSS/ IND FOSS
Supply and fix Scanner 10Amps, UV cut off 340 to 360V complete all as specified and as directed
KRISHNA ENTERPRISES
C SRINIVASAN
SRI VENKATESWARA ENTERPRISES
RK ENTERPRISES
muthu constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .