| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹9.9 LAccepted-AOC A 123 3 JAITPUR EXTN KALINDI KUNJ ROAD BADARPUR NEW DELHI 110044 | SOUTH EAST | DELHI | 110044 | L-1 | Accepted-AOC L-1 Bidder | |
| 2 | L-2₹12.0 L+₹2.1 L (21.6%)Rejected-Finance 94 D POCKET J AND K DILSHAD GARDEN DELHI DELHI 110095 UDYAM DL 02 0018675 07AHCPD1811D1Z7 B R | SHAHDARA | DELHI | 110095 | L-2 | Rejected-Finance Second Lowest | |
| 3 | Rejected-Technical | - | Rejected-Technical Not meeting NIT criteria | |
| 4 | Rejected-Technical 107 265 BRAHAMA NAGAR KANPUR UP 208012 | KANPUR NAGAR | UTTAR PRADESH | 208012 | - | Rejected-Technical Not meeting NIT criteria | |
| 5 | Rejected-Technical | - | Rejected-Technical Not meeting NIT criteria |
Tender Value
₹12.9 L
EMD Value
₹38,844
Closing Date
2 Apr 2025, 3:00 pmClosed
PARMEET DAHIYA
AAI, RHQ, NR, 2ND FLOOR, NATS COMPLEX, IGI AIRPORT, NEW DELHI-110037
SITC OF ADDRESSABLE FIRE DETECTION AND ALARM SYSTEM AT AAI GAGAN NANGLOI
2025_AAI_229520_1
AAI/SME/ENGG/NGL-FIREALARM
Open Tender
Electrical Works
Item Rate
90 days
AAI NANGLOI
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,180
₹38,844
4 Jul 2025
12 Mar 2025
3 Apr 2025
12 Mar 2025
2 Apr 2025
12 Mar 2025
12 Mar 2025 - 16 Mar 2025
Amount
Supply, Installation, Testing & Commissioning of 4 loops (with 2 loop card) Microprocessor based Intelligent Digitally Addressable Fire Alarm Control Panel with minimum 250 devices (250 in any combination per loop). The panel shall have minimum 7 inch screen display with soft keys for displaying alarm, events and operating functions, compatible with graphic user interface for pin point the identification of the fire location suitable to operate on 240 volts AC power supply. The panel shall be equipped with automatic battery charger, 24 volts maintenance free batteries sufficient for 24 hours working in normal condition & and then be capable of operating the system for minimum 30 minutes during an emergency conditions as required. (EN/UL 10th Edition & FM approved with latest amended upto date). The fire alarm panel shall have storage of 10000 event log and dongle free programming. The panel shall have interfacing connectivity on BACNET / MODBUS / Open protocol for interfacing with Building Management System complete as required.
Supply, Installation, Testing & Commissioning of EN/ UL listed Fire Alarm Repeater Panel with 4.3 inch screen display complete system function keys for programming and control like System Reset, Alarm Acknowledge, Alarm Silence, Trouble Acknowledge etc.The Panel shall be connected/ Interface to Main Fire Alarm Panel. (EN/UL latest edition & FM approved)
Supply, Installation, Testing & Commissioning of UL / EN listed Intelligent Photoelectric Smoke Detector with Inbuilt Fault Isolator/Isolator Base, Alarm Indication LED with Electronic Addressing Feature to programme the detectors complete as required to be installed under/ above false ceiling, roof & concealed space etc. inter-connecting to loop cable complete as required. (EN/UL latest edition & FM approved)
Supply, Installation, Testing & Commissioning of EN/ UL listed Intelligent Addressable Multi Criteria Type (photoelectric smoke detection & thermal fixed cum rate of rise temperature detection) Smoke Detector with Inbuilt Fault Isolator/Isolator Base, Alarm Indication LED with Electronic Addressing feature to programme the detectors complete as required to be installed under/ above false ceiling, roof & concealed space etc. inter-connecting to loop cable complete as required. (EN/UL latest edition & FM approved)
Supply, Installation, Testing & Commissioning of Response Indicator (METAL CLADE) which consists of steady glowing LED. This LED shall be mounted within a M.S. box and connected in parallel to the built in indicator of the detector as per specifications. The RI shall come "ON" as soon as the detector activates complete in all respects as per specification. (EN/UL latest edition & FM approved)
Providing, Installation, Testing & Commissioning of EN/ UL listed Addresable Relay Module with Inbuilt Fault Isolator/ Isolator Module with minimum IP50 load 1A @ 24V DC (for control of AHU, ventilation fan etc) complete as required. (EN/UL latest edition & FM approved)
Supply, Installation, Testing & Commissioning of EN/UL listed monitor module with Inbuilt Fault Isolator/ Isolator Module with minimum IP50 (for monitoring different electrical/mechanical device like flow switch etc.) (EN/UL latest edition & FM approved)
Supply, Testing and Commissioning of Loop Powered Hooter cum Strobe/Supervised Power Supply with Inbuilt Fault Islolator/Isolator Module complete with all accessories and base as required. (EN/UL approved)
Supply, Installation, Testing & Commissioning of EN / UL listed Addressable type Manual Call Point (resetting type) complete with Inbuilt Fault Isolator/Isolator Module with minimum IP40. (EN/UL latest edition & FM approved)
Supplying & laying of 2x1.5 sqmm Fire Survival Armoured Cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.
Supply and laying of 4 core x 1.5 sqmm screened copper cable for communication between Fire Alarm Panels and Repeater Panels.
NATIONAL SAFETY ENGINEERS (BID ID -837102)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .