Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance BUS STAND ROAD BARARA AMBALA | BARARA | AMBALA | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Not Admitted-Fee 515 5 INDUSTRIAL AREA B LUDHIANA PUNJAB 141003 | LUDHIANA | PUNJAB | 141003 | Not Admitted-Fee Fee not received |
Tender Value
Refer Docs
EMD Value
₹35.0 L
Closing Date
6 Nov 2019, 5:00 pmClosed
SE/MM-I
Shakti Bhawan (Basement), Sector-6, HVPNL, Panchkula
Construction of 132kV lines in Rewari and Mahendargarh area
2019_HBC_102412_1
NIT No. 1082/EPC-D-275
Open Tender
Electrical Works
450 days
Rewari and Mahendargarh
As per tender Document.
8 documents required · 8 mandatory
₹11,800
HVPNL
₹35.0 L
Yes
14 Jan 2020
11 Sept 2019
13 Nov 2019
11 Sept 2019
6 Nov 2019
11 Sept 2019
Construction of 132 kV lines in Rewari & Mahendargarh area
Fabrication and supply of following tower parts with stubs, bolts & nuts, step bolts, U-bolts, hangers, D-shakle etc. of following Designs: i) 132 kV D/C 'DA' type tower (KRR Design)
ii) +3 mtr. extn only.
iii) +6 mtr. extn only.
iv) +9 mtr. extn only.
i) 132 kV D/C 'DB' type tower (KRR Design)
ii) +3 mtr. extn only.
i) 132 kV D/C 'DC' type tower (KRR Design)
ii) +3 mtr. extn only.
i) 132 kV D/C 'DD' type tower (KRR Design)
ii) +3 mtr. extn only.
iii) +9 mtr. extn only.
iv) +18 mtr. extn only.
i) Extra Cross Arm only (Set of 3)
220 kV M/C 'MD' type tower (KRR Design)
i) Extra Cross Arm only (Set of 6)
132KV Gantry D/C
Fabrication and supply of following tower parts with stubs, bolts & nuts, step bolts, U-bolts, hangers, D-shakle etc. of following Designs: 132 kV S/C Towers of HSEB Design. i) 132 kV S/C 'A' type Towers without stub of HSEB Design.
ii) 132 kV S/C 'A' type Tower's stub of HSEB Design. Only +3 mtr. Extn. Only
i) 132 kV S/C 'B' type Towers with stubs of HSEB Design.
ii) +3 mtr. Extn. Only
iii) +6 mtr. Extn. Only
132 kV S/C 'C' type Towers without stub of HSEB Design.
i) 132 kV S/C 'C' type Tower's stub of HSEB Design only
ii) +3 mtr. Extn. Only
132kV S/C gantry
Design, Testing, fabrication supply and Erection of 132 kV D/C monopole with Foundation & all parts like cross arms, bolts & nuts, step bolts, U-bolts D-Shakles etc. i) 132 kV D/C 'DD' type Monopole complete set.
Supply of earthing of Towers/ Gantry i) Pipe type
Supply of following Tower accessories i) Danger Plate
ii) Number Plate
iii) Phase Plate(set of 3)
iv) Circuit Plate (set of 4)
v) Bird Guard. (set of 3)
vi) Anti climbing device
Conductor: ACSR Zebra conductor 0.4 sq inch
Conductor: ACSR Panther conductor 0.2 sq inch
Earthwire: 7/3.15mm
OPGW (24 fiber) DWSM
OPGW (48 fiber) DWSM
Hardware set for above 24 Fiber OPGW fiber optic cabling including all cable fittings & accessories(equivalent to E/wire 7/3.15mm) except joint box
Hardware set for above 48 Fiber OPGW fiber optic cabling including all cable fittings & accessories(equivalent to E/wire 7/2.5mm) except joint box
Joint Box 24 fiber OPGW to OPGW (as applicable )
Joint Box (24 fiber) OPGW to OFAC
Joint Box 48 fiber(3 way) OPGW to OFAC
Fiber optic Approach cable, 24 fiber (DWSM) along with PLB HDPE Ducts of suitable size & strength and all accessories
Fiber optic Approach cable, 48 fiber (DWSM) along with PLB HDPE Ducts of suitable size & strength and all accessories
FODP 48F: Indoor type, rack mounted with FCPC coupling and pig tails (5mtrs. Each)
FODP 96F: Indoor type, rack mounted with FCPC coupling and pig tails (5mtrs. Each)
Joint Box (48/24/24 fiber) OPGW to OPGW (3way) as applicable
132 kV Post Insulators
*A/F type Disc Insulator or 132 kV Silicon Rubber Polymer Insulator strings * for Zebra / Panther Conductor i) 70kN
iii)120 kN
Hardware Fittings of ACSR Zebra conductor i) Single I suspension string
ii) Single suspension pilot string
iii) Single Tension string
Hardware Fittings of ACSR Panther 0.2 sq" i) Single 'I' suspension string
ii) Single suspension pilot string
iii) Single Tension string
ACSR Zebra conductor and earthwire (7/3.15 mm) accessories i) Mid Span Compression Joint for conductor
ii) Repair sleeves for conductor
iii) Vibration damper for conductor
iv) Mid Span Compression Joint for earthwire
v) Flexible copper bond for conductor
vi) Vibration damper for Earthwire
vii) Earthwire Tension Clamp
viii) Earthwire Suspension Clamp
Conductor and earthwire (7/2.5 mm) accessories for panther conductor i) Mid Span Compression Joint for conductor
ii) Repair sleeves for conductor
iii) Flexible copper bond for conductor
iv) Vibration damper for conductor
v) Vibration damper for Earthwire
vi) Earthwire Tension Clamp
Telecom Equipment SDH Equipment (STM - 16 MADM upto 5 MSP protected directions) Base Equipment (Common cards, Cross connect/control cards, optical base cards, power supply cards, power cabling, other hardware and accessories including sub racks, patch cord, DDF etc. fully equipped excluding (ii) & (iii) below
S16.1 SFP(The quantities will be decided at the time of detailed engineering)
L16.2 SFP(The quantities will be decided at the time of detailed engineering)
S4.1 SFP(The quantities will be decided at the time of detailed engineering)
L4.2 SFP(The quantities will be decided at the time of detailed engineering)
Tributary cards E1 Interface card ( Min. 32 interfaces per card)
Ethernet Interface 10/100 Base T with Layer-2 switching (Min. 8 interfaces per card)
Gigabit Ethernet (Layer 2) Interface (min. 2 nos.)
Equipment Cabinet with DDF and all installation accessories
Network Manager System - Craft Terminal Hardware
Software
VOIP telephone instrument with one common switch(min. 8 port) compatible with SLDC
Integration of the Equipment with existing network Note: Above quantity covers the requirement of remote station as well. If the equipment for remote end is already available then the same for remote end is not required.
Mandatory Spares Transmission Equipment SDH Equipment (STM - 16 MADM upto 5 MSP protected directions) Optical Interface Cards/SFP S16.1 SFP(The quantities will be decided at the time of detailed engineering)
L16.2 SFP(The quantities will be decided at the time of detailed engineering)
S4.1 SFP(The quantities will be decided at the time of detailed engineering)
L 4.2 SFP(The quantities will be decided at the time of detailed engineering)
Tributary cards E1 Interface card ( Min. 32 interfaces per card)
Ethernet Interface 10/100 Base T with Layer-2 switching (Min. 8 interfaces per card)
Gigabit Ethernet (Layer 2) Interface (min. 2 nos.)
Pre Connectorized Optical Fibre Patch Cords (10 Mtrs.)-Pack of six Patch cords
DISMANTLEMENT WORK to be included in Erection Part i) Dismantlement of tower and their transportation & proper statcking at any dedicated store of HVPNL. The dismentalment of tower shall also include dismentalment of stub concrete upto a depth of 1 M (one meter) from natural Ground level, back filling, compaction and clearing the site of debris. a) 132 kV S/C "C" type tower of HSEB design
a) 132 kV S/C "A+3" type tower of HSEB design
Dismantlement of existing 0.2 sq" ACSR Panther Conductor complete with H/W fittings for above portion of line and their transportation & proper statcking at any dedicated store of HVPNL.
Dismantlement of existing earthwire (7/2.5mm) complete with H/W fittings for above portion of line and their transportation & proper statcking at any dedicated store of HVPNL.
Dismantlement of existing of 132 kV MahendergarhDahina line (H-Pole & ower) and their transoportation & proper stacking at any dedicated store of HVPNL. The dismantlement of H-pole / tower in all respect from Natural ground level, back filling, compaction and clearing the site of debris H-pole
Dismantlement of 132 kV S/C C+0 type tower HSEB design
Dismantlement of tower of 132 kV S/C Rewari-HSIIDC BaWAL (SA+0) line and their transportation & proper statcking at any dedicated store of HVPNL. the dismentalment of tower shall also include dismentalment of stub concrete upto a depth of 1 M (one meter) from natural Ground level, back filling, compaction and clearing the site of debris.
Dismantlement of existing of 0.15 sq inch ACSR Wolf conductor complete with H/W fittings, insulators for above portion of line and their transportaton & proper stacking at any dedicated store of HVPNL.
Transportation and erection of tower part with stubs (as applicable), bolts & nuts, step bolts, U-bolts, hangers, D-shakle etc. of following type of tower of 132 kV S/C Towers of HSEB Design (Note: The quantity available in SSW Panipat to be transported and erected by EPC contractor at site complete in all respect) :- 132 kV S/C 'A' type Towers without stub of HSEB Design.
ii) 132 kV S/C 'A' type Tower's stub of HSEB Design. Only
132 kV S/C 'C' type Towers without stubs of HSEB Design.
Detailed Survey
Furnishing bore log data
Construction of tower foundations as per HVPNL Drgs& Specs for 0 to 6M extn. including excavation, concreting, supply and placement of steel reinforcement and backfilling complete in all respect. i) 132 kC D/C 'DA' type Tower (KRR Design) classified as - Dry
- Wet (w/out de-watering)
ii) 132 kC D/C 'DB' type Tower (KRR Design) classified as - Dry
- Wet (w/out de-watering)
iii) 132 kC D/C 'DC' type Tower (KRR Design) classified as - Dry
iii) 132 kC D/C 'DD' type Tower (KRR Design) classified as - Dry
- Wet (w/out de-watering)
(A) Construction of tower foundations as per HVPNL Drawings & Specifications for 0 to 6M extension including excavation, concreting, supply and placement of steel reinforcement and backfilling complete in all respect. i) 132 kV S/C 'A' type tower (HSEB Design) classified as - Dry
i) 132 kV S/C 'B' type tower (HSEB Design) classified as - Dry
- Wet (w/out de-watering)
i) 132 kV S/C 'C' type tower (HSEB Design) classified as - Dry
Construction of 132 kV Gantry foundations BT-6 & BT-7 of HSEB design
Construction of tower foundations as per HVPNL Drgs& Specs for 0 to 6M extn. including excavation, concreting, supply and placement of steel reinforcement and backfilling complete in all respect. i) 220 kV M/C 'MD' Type Tower (KRR Design) classified as - Dry
(B) Construction of tower foundations as per HVPNL Drawings & Specifications for 9 M to 25 M extension including excavation, concreting, supply and placement of steel reinforcement and backfilling complete in all respect.i) 132 kV 'DA +9 M' type tower (KRR Design)classified as - Dry
i) 132 kV D/C 'DD +9M' & 'DD+18M' type tower (KRR Design)classified as - Dry
Construction of 132 kV Gantry foundations as per KRR Design, One set consisting of T-1 & T-2 (1 set of 3 no.) including excavation, cutting, placing of steel, concreting, backfilling complete in all respect.
Dewatering of subsoil water for lowering of water table to enable excavation of earth, concreting for foundations/stub and backfilling, by boring of tube wells or deploying well point system so that continuous lowering of water table is made till completion of work, without disturbing the soil characteristics. The rate shall include all type of expenditure for required dewatering arrangements and irrespective of type of tower i/c extensions if any i.e. KRR design or TATA design
Protection Measure Brick masonry in 1:4 cement sand mortar including excavation
Earth filling, compaction, leveling etc inside revetments
M-20 (1:1½ :3 mix) concrete for top seal cover, for revetment etc.
Lean concrete (1:4:8)
RCC 1:1.5:3 (M20) including all material, labour, excavation, cutting and placing of steel, centering & shuttering, concreting etc. complete in all respect.
K. Ramachandra Rao Transmission and Projects Pvt. Ltd.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid