| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.8 LAccepted-AOC 4 4 FAIRLIE PLACE ROOM NO 630A HMP HOUSE KOLKATA 700001 700001 CALCUTTA CENTRAL DIVISION WEST BENGAL 700001 | KOLKATA | WEST BENGAL | 700001 | L1 | Accepted-AOC Quoted rate found Lowest (L1). | |
| 2 | L2₹21.9 L+₹9,625 (0.44%)Rejected-Finance MIA GARAGE BUILDING 1ST FLOOR HILLCART ROAD DIST SILIGURI PIN 734401 | SILIGURI | SILIGURI | WEST BENGAL | 734401 | L2 | Rejected-Finance Quoted rate found 2nd Lowest (L2). | |
| 3 | L3₹22.2 L+₹33,975 (1.56%)Rejected-Finance NICHUPATY BOLPUR P WEST BENGAL BIRBHUM PIN 731204 | BOLPUR | BIRBHUM | WEST BENGAL | 731204 | L3 | Rejected-Finance Quoted rate found 3rd Lowest (L3). | |
| 4 | Rejected-Technical 14 HARE STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | - | Rejected-Technical Technically Disqualified |
Tender Value
Refer Docs
EMD Value
₹46,000
Closing Date
28 Mar 2025, 3:00 pmClosed
EXECUTIVE ENGINEER PWD MALDA ELECTRICAL DIVISION
O/O THE EXECUTIVE ENGINEER PWD MALDA ELECTRICAL DIVISION Singatala Malda PIN 732101
District Level Drug and Vaccine Procurement and Distribution Centre with Cold Chain facility at Muchia PHC, Malda. (Electrical) RN 23000103 - SITC of 160 KVA DG Set
2025_WBPWD_817123_1
WBPWD/EE/MED/e-NIQ-45/2024-25
Open Tender
Electrical Work/ Equipment
Item Rate
60 days
MUCHIA
Please refer Tender documents.
6 documents required · 6 mandatory
₹46,000
26 Jun 2025
18 Feb 2025
2 Apr 2025
18 Feb 2025
28 Mar 2025
21 Feb 2025
Amount
Supply, delivery at site on foundation, commissioning of 160 KVA, 415V, 50Hz, 3Ø silent new DG Set, comprising of Engine, alternator, separate AMF panel, Base frame, Fuel tank, Battery, CPCB IV+ approved Engin & Acoustic Enclosure including transportation, loading and unloading of the DG set, having following specifications :- [Make: Cummins JAKSON / KOEL GREEN / GREAVES POWER / Volvo/ Catterpillar].
ENGINE
Make : CUMMINS / KIRLOSKAR / GREAVES POWER / Volvo / Catterpillar.
Engine Type : 4 Stroke Diesel Engine
Rated Output : 196 BHP or Higher
Duty : PRIME
Cooling : Water cooled with radiator
Cylinder : 6/8
Aspiration : Turbo Charged
Type of Governer : Electronic
Fuel Tank Capacity : Minimum capacity 250 Ltrs. or above.
Fuel Consumption at 75% rated Load with Radiator or Fan : 28.41 Ltr./ Hr. or Less. Lube Oil change period - 550 hrs or above.
Fuel Consumption at 100% rated Load with Radiator or Fan : 36.9 Ltr./ Hr. or Less
Overload Capacity : 10% overload for one hour for every 12 hours continious running at full load or better.
Engine instrument Panel : Consisting of starting switch with Key, Lube Oil Indicator, water temperature Indicator, RPM indicator and hour meter.
Safety Controls : Emergency Stop, Low Lube Oil Pressure warning/ Shutdown, High Engine Water Temp. warning/ Shutdown, Sensor failure Indicator, Engine overspeed indicator, Battery charging and low battery indicator
Exhaust Silencer : Residential Type
Starting system : 12V./ 24 V. starting system complete with starter motor, charging alternator with rectifier and Cutout as per manufacturer standard.
Battery : Lead Acid, Low Maintenance or SMF and conforming to relevant IS Specification with Low/High Battery Voltage and Weak Battery warning. Displacement - 7000ce and above.
ALTERNATOR
Make : STAMFORD / KIRLOSKAR GREEN / GREAVES POWER / Volvo / Catterpillar / LEROY SOMER.
Rating : 415 V., 3Ph. 50 Hz., 160 KVA, 1500 rpm
Type : Brushless, self excited and self regulated
Insulation : Class H
Protection : Screen-protected drip proof with Min.IP-23 degree of protection
Voltage Regulation (max) : ±1%
Winding connection : Star with Neutral
Total Distortion factor : Less than 3%
Total Harmonic distortion in output waveform : < 5%
AMF PANEL
Cubical type floor mounted AMF panel made from 16 SWG Sheet Steel, duly pretreated, powder coated painted and aesthetically finished, suitable for controlling of 160 KVA DG set having following specification/features.
i) 250 A , 4 pole Power Contactor & MCCB with O/L, S/C, E/F protection and microprocessor based protection release , U/V release etc. - 2 Sets
ii) In Built By-Pass switch for rated capacity
iii) On -delay timer for load change over
iv) On-delay timer for engine shut off
v) Engine On-Off switch (Push button type)
vii) Minimum five number indicating lamps to indicate 'mains ON', 'load on mains', Set running', 'load on set' and 'battery charger on'.
viii) Audio visual alarm for 'Low lubricating oil pressure', 'High water temperature, Start failure', and DG over load'.
x) Microprocessor based relay with composite meter for digital display of following.
Generator voltage/AC Mains voltage.
Generator Current in all phases
Frequency
Power Factor
Energy
Indication for alternator supply
Running time indications number of hours of operation and service intervals, service due indications.
The AMF panel must be designed to ensure trouble free performance and ensure switching over Electrical Load to DG within 15 (fifteen) second from the instant of mains failure.
ACOUSTIC ENCLOSURE
The DG set should have integrated acoustic enclosure at the manufacturing state itself. High quality acoustict enclosure must be certified as per CPCB-IV+ norms.
BASE FRAME
Common iron channel fabricated base frame containing the engine and alternator, mounted on AVM pads and having provision for lifting Hook.
TERMS & CONDITIONS
(i) Rate should be quoted inclusive of all applicable taxes and Duty etc.
(ii) All materials, equipments & accessories must conform to relevant IS /IEC specifications. The DG Set to be supplied must be from the authorized OEM of the respective Engine Manufacturer.
(iii) Necessary manufacturer's test certificate for Diesel Engine, Alternator etc. Will have to submit in triplicate copy during delivery of the equipment.
(iv) Copy of "Type Approval Certificate" and Certificate of "COP" must be produced at the time of delivery issued from competent Authority (As per CPCB-IV+).
(v) Circuit Diagram for AMF Panel must be submitted from the Manufacturer/OEM.
(vi) The entire set must be warranted at least 15 months from the date of commissioning. However Engine & Alternator should be warranted of 2 years/5000 Hrs, whichever is earlier.
M/S. N.C. HORE (BID ID -6193387)
NARAYAN CHANDRA DAS (BID ID -6283017)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .