Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance COIMBATORE COIMBATORE TAMIL NADU | TIRUPPUR | TAMIL NADU | 638459 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹10 L
EMD Value
₹10,000
Closing Date
14 Mar 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Commissioner, Jayankondam Municipality
Municipal Office, Jayankondam
Providing Deep Borewell at N.A.G Colony in Ward No.13 in Jayankondam Municipality.
2024_MAWS_447069_1
0315/2024/E1
Open Tender
Water Supply/Equipments/Meter/Drilling/Boring
Works
30 days
Jayankondam Municipality
Refer Tender Notice
1 document required · 1 mandatory
₹0
₹10,000
14 Mar 2024
11 Mar 2024
14 Mar 2024
11 Mar 2024
14 Mar 2024
11 Mar 2024
Amount
Drilling of Borewells anywhere in Tamilnadu including transportation from one place to another with in Tamilnadu in alluvial soil sedimentary strata of clay and sand stone shale pebbles boulders etc. By first taking a pilot bore of 140 mm/150mm dia and then enlarging to required dia direct or reverse rotary mud circulation method using rotary rigs, fuel, labour and drilling bentonite and water required for drilling at site ( Site will be shown by the TWAD Board Officers) including construction of mud pit. (TWAD 2022-23 P.NO 302)
a) Upto 60m depth below GL
b) From 60m to 90m below GL
c) From 90m to 120m below GL
d) From 120m to 180m below GL
Reaming from 150mm dia pilot bore to 300mm dia as directed by Officers. (TWAD 2022-23 P.NO 302)
a) Upto 60m depth below GL
b) From 60m to 90m below GL
c) From 90m to 120m below GL
d) From 90m to 120m below GL
Supply delivery and conveyance of PVC pipes and specials at site
a) 200mm PVC plain pipe (CM)
b) 200mm PVC Ribbed screen pipe
Labour Charges for inserting PVC Casing pipes assembly (with slots or without slots) in the drilled hole including jointing the pipes with PVC Couplers with Cement paste etc., complete, supply and packing the annular space with pebbles of size and quality as approved by the executive engineers of TWAD Board (TWAD 2022-23 P.NO 304)
200mm casing pipe
Charges for developing the borewell with air compressor of 300 CFM capacity (Minimum 8 Hours) including transportation labour and fuel charges for compressor as directed by TWAD Board Officers and conducting yield test by 'V' notch method. (TWAD 2022-23 P.NO 305)
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately). (TWAD 2022-23 P.NO.114)
Supply and delivery of clear water vertical wet type submersible pumpset suitable for 150mm dia borewell conforming to IS 8034/2002 as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continous rated two pole suitable wet type vertical squirrel cage induction motor as per IS9283 /1995 as amended there after, suitable for operation in AC three phase 415 V+/- 10 %, 50 HZ +/- 5 % (LPM*M 125*200) (TWAD 2022-23 P.NO 102)
Supply and delivery of PVC insulated and sheathed 3 core flat type copper cable conforming to is 694/1990 and as amended thereafter etc., complete. (TWAD 2022-23 P.NO 120)
Supply and delivery of 75mm PN8 HDPE pipe-PE100 as per IS 4984/1995 etc., complete. (TWAD 2022-23)
Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days. (TWAD 2022-23 P.NO 308)
Supply and fixing of TNEB meter Board suitable for 32A three phage service connection with 3 nos. 32A aerial fuse unit (500V) 32A natural link and earth (1”x1/8” copper flat) on TW plank of size 600mm x450mmx19mm with supporting TW reepers of 1” thick an either side with paining with suitable bolt and for fixing the TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire EB motor to fuse unit (SD 127).
Supply and run of 4 of 6 sq.mm. (84 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade on 7 / 20 GI bearer wire for service connection mains SD68
ravikumar
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .