Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.0 LAccepted-AOC H NO 273 VPO SURHERA WEST DELHI 110043 | WEST DELHI | DELHI | 110043 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹41.3 L+₹1.1 L (2.71%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹42.2 L+₹2.0 L (5.08%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | L4₹42.9 L+₹2.7 L (6.72%)Rejected-Finance | L4 | Rejected-Finance Rejected | |
| 5 | L5₹43.0 L+₹2.8 L (7.00%)Rejected-Finance C O OPPOSITE BDO OFFICE MANDA AKHNOOR DISTT JAMMU PIN 181201 | JAMMU | JAMMU AND KASHMIR | 181201 | L5 | Rejected-Finance Rejected |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
23 Dec 2022, 6:00 pmClosed
GE Faridkot
GE Faridkot Military Station
Repair/maint of roof treatment and allied other works in Md Accn under AGE B/R (M) at Faridkot Mil Stn
2022_MES_566567_1
GE FRD-62/2022-23
Open Tender
Civil Works
Item Rate
240 days
GE Faridkot
Class D Category a i
8 documents required · 8 mandatory
₹500
GE Faridkot
₹80,000
Yes
30 Dec 2022
1 Dec 2022
26 Dec 2022
1 Dec 2022
23 Dec 2022
16 Dec 2022
Amount
Dismantling of brick tiles or terracing tiles single layer on roof & disposal of retrieved material to a distance n.exc 100m from the starting point complete all as specified and specified
Demolition of mud in roof, any thickness including plastering and leaping (where full thickness removed or only a part there of ) and disposal of retrieved material to a distance n.exc 100m from the starting point complete all as specified and specified
M&L for PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregates) as in roof kerbs or mud stops, rounded or chamfered angles complete all as specified and directed.
Cleaning of surface, washing the surface and removing all existing bitumen coatings/ APP membrane completely with intense wire brushing or high speed water jet & M&L for 70mm thick(Average thickness) PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) laid over roof slab in specific gradients/slope complete all as specified and directed by Engineer-in-Charge.
M&L for Roof Treatment as specified below and as directed : (a) Cleaning, of surface & making it free from any loose paint, dust or dirt, grease. (b) All cracks upto 3mm at corner joints, channels and parapets should be treated with crack seal and bigger cracks, damaged portions and hollow areas must be repaired with polymer modified cement mortars. (c) Applying one coat of PrimeSeal/ Epoxy Primer/ShaliUrethane BTD White diluted with potable water in the ratio of 1:1 and apply @ 0.40 kg/ sqm (0.20 kg BTD+0.20 Kg water) (d) Laying polyster reinforced fiber net/50 gsm Geotextile mesh, upto 300 mm on walls. (e) Applying three coat of HydroShield PUD microfibre reinforced UV resistent polyurethane (solid content 68% ) / Damp Proof ultra UV Stable fibre reinforced elastomeric liquid waterproofing membrane formulated with PU hybrid polymers (Solid content 55%)/ SmartCare PU Magnum elastomeric waterproofing coating based on hydrophobic polyurethane (solid content 85%)/Single Component Elastomeric Liquid Membrane ShaliUrethane BTD White/coloured (Elongation 400% ± 50, Solid Contents > 80% & Specific Gravity @ 30 OC 1.5 ± 0.03) @ total 2.00 Kg per sqm in two coats for maintaining thickness of 1.5mm, with paint brush/ roller upto 300 mm on walls. (f)) Complete treatment to be carried out by authorised applicator of waterproofing manufacturer. Make : Dr. Fixit / Fosroc / BASF / STP/Torch Tar/Asian. Note : (i) The treatment shall be carried out as per the manufacturers instructions, and as directed by Engineer in Charge. (ii) The plan area of floor shall be considered for payment (iii) WPC shall be measured and paid seperately. Note (i) The treatment shall be carried out as per the manufacturer's instructions, and as directed by Engineer-in-Charge. (ii) The plan area of floor shall be considered for payment.
Demolition of Reinforced Cement Concrete of any description or in any position not otherwise specifically provided for complete all as specified and directed.
M&L for providing Reinforced cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as chajjas,parapet complete all as specified and directed and directed .
M&L for providing Reinforced cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as lintels, beams, cantilivers and like complete all as specified and directed and directed .
M&L for use and waste of form work to chajjas and similar items including edges for any height of building,surface rough finished complete all as specified and directed .
M&L for use and waste of form work to sides and soffits of floor or roof beams, beam hunching, girders, lintels, cantlievers, shelves including supports, etc for rough finished flat surfaces of concrete complete all as specified and directed.
M&L for Mild steel TMT bars 6 to 8mm dia , cut to length, bent to shape as required, including cranking, bending and binding with & including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed .
Demolition of Brickwork or stone/boulder masonry,built in cement mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L brick work with fly ash bricks, straight or curved on plan exceeding 6 metre mean radius, built in cement mortar 1:6 complete all as specified and directed .
All as per Srl item No. 13 here-in-before but except bricks.
M&L for brick work with sub class 'B' bricks, using old size bricks, straight or curved on plan to any radius in half brick thick honey comb walling, built in cement mortar 1:4 complete all as specified and directed . Note: " Work may be carried out at upto 3rd floor/roof."
Taking down cement plaster from brick walls including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for 15 mm thick rendering in cement mortar 1:6, on brick work or concrete surfaces, finished even & smooth without using extra cement complete all as specified and directed .
M&L for rendering 10mm thick in cement mortar 1:3 on ceiling, surface finished even and smooth without using extra cement complete all as specified and directed.
M&L repair to RCC fillet beams in ceiling with cement mortar 1:3 over applying a coat of neat cement slurry @ 3kg/sqm and one coat of bonding agent as per manufacturer's specifications complete all as specified and directed Make of Bonding Agent:- Dr Fixit/Fosroc Nitobond/Sikka Hibond
M&L for preparation of newly plastered or unplastered surfaces of wall and applying two coat of distemper oil emulsion (white/tinted) after finishing the surfaces with a coat of wall care putty by hand roller complete all as specified and directed .
M&L for preparation of old surfaces of walls including brooming down or steel wire brushing, scrapping down smoke soot, mould, moss, efflorescent salts, trading oil and greasy spots and applying one coat of oil bound distemper including filling of wall care putty in minor cracks (where required) complete all as specified and directed .
M&L for preparation of new plastered surfaces of wall and applying three coats of white wash complete all as specified and directed .
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed .
M&L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed .
M&L for preparation of newly plastered or unplastered surfaces of wall and applying two coat of cement base paint complete all as specified and directed
Taking up or down 15mm dia GI/PVC tubing and connection including, cleaning for refixing or removal to store complete all as specified and directed .
Taking up or down 20mm dia GI/PVC tubing and connection including, cleaning for refixing or removal to store complete all as specified and directed
S&F Galvanised steeI tubing,15mm bore, medium grade with all fittings , fixed to wall/ceiling and laid in floors complete all as specified and directed .
All as per item No 28 here-in-before but except tubes
S&F Galvanised steeI tubing,20 mm bore, medium grade with all fittings , fixed to wall/ceiling and laid in floors complete all as specified and directed .
All as per item No 30 here-in-before but except tubes
S&F in repair 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed .
S&F in repair 15mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed .
Dismantling CI/PVC pipe of 75mm/100mm dia alongwith fittings ,below or above GL/laid in floors/fixed to walls jointed in cement mortar complete all as specified and directed.
S&F 110mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints, laid in trenches/in floors/fixed to walls including fixing clamps with nut and bolts complete all as specified and directed .
S&F PVC (SWR) bends any radius ,110mm bore complete all as specified and directed.
S&F in repair rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 500 Ltr capacity.triple layered, hoisted and fixed in position including ball brass valves, high pressure, with polythene float and fly nut screwed for 20mm bore iron pipe complete all as specified and directed .
Disconnecting existing tanks of capacity 500 ltrs, setting aside (or lowering if required) for repairs etc and hoisting if required, including cleaning and removing all scale and dirt ,etc from the the tank & from the mouths of circulating pipes etc,reconnecting and re-fixing in position complete all as specified and directed.
S&F in repair rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 1000 Ltr capacity.triple layered, hoisted and fixed in position including ball brass valves, high pressure, with polythene float and fly nut screwed for 20mm bore iron pipe complete all as specified and directed .
Excavating in post holes each not exc 0.50 cum, getting out in soft/loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layer not exc 25cm and removing surplus soil to a distance not exc 50m and making good surface all as specified`and directed .
M & L for cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregates) as in foundations, filling and mass concrete complete all as specified and directed
S&F Mild Steel framed work such as grills, gratings etc. with ends of bars shoulderd and/or riveted, or forged into spikes, framed guard bars, barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks,cooler stand,ladder and similar work conforming to Fe290, Gde-E-165 complete all as specified and directed.
M&L for preparation of new or previously untreated steel surface of any description over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. Note :- A Sum of Rs. 1,20,475.00 will be deducted on account of credit for dismantling/ demolished/ taking down material. Please refer detail on srl page No. 19 (Schedule of credit) of Tender Documents.
M/S BSS AND SONS
msgurjantconstructioncompany
NAV DURGA CONSTRUCTION CO
DEEPAK ENTERPRISES
Vinod Kumar Bajaj
NEW AMRITSAR CONSTRUCTION COMPANY
BABA FARID CONSTRUCTION CO
SHIV SHAKTI BUILDERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .