Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.0 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 bidder. | |
| 2 | L2₹10.3 L+₹31,200 (3.13%)Rejected-AOC | L2 | Rejected-AOC Rejected being L2 bidder |
Tender Value
₹10.5 L
EMD Value
₹20,920
Closing Date
1 Mar 2023, 5:00 pmClosed
Er. Puneet Kumar
Resident Engineer PPH Divn BBMB (PW) Talwara Township
NIT for Providing roof leakage treatment, vitrified glazed tiles on existing cement concrete floors, replacement of damaged doors and change of electrical fittings, wiring of different police barracks at Pong Power House under BBMB (PW) Talwara.
2022_BBMB_91188_1
04/REPPH BBMB
Open Tender
Civil Works
Tender cum Auction
180 days
Pong Power House, Near Sansarpur Terrace (HP)
As per tender documents.
2 documents required · 2 mandatory
₹1,180
₹20,920
10 Oct 2023
14 Oct 2022
3 Mar 2023
14 Oct 2022
1 Mar 2023
14 Oct 2022
14 Oct 2022 - 1 Mar 2023
Amount
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing.
First Class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level.
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16.
Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 2.5 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge. (If fixed on wall face clamp to be paid separatly as per respective item).
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. (a) UPVC 110 mm bend.
Providing and fixing in position MS or heavy flat iron clamps made out of MS flat iron not less than 5 mm of the approved design for fixing CI soil waste, vent or antisyphonage pipes to walls complete in all respect including cutting and making good the walls and floors etc. and painting. (a) MS holder bats clamps for 100 mm i/d HCI pipes.
Nicking cement concrete surface (over 28 days old including preparation and laying slurry)
Scraping (c)Cement Plaster
Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete white cement slurry in joints including corners angles and beading.
Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body /thickness of tile whichmakes chips and scratches less noticeable and make na ideal choice for high traffic zones.) (a)Size 600x600 mm
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/ Highlighter/emboss conforming to IS :15622 (thickness to be specified by the manufacture of approved make in all colours, shades except urgundy, bottle green, black of size 450 x 310 mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS :1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminum snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In- Charge. (Glazing and paneling to be paid for separately) : a) For fixed portion and chaukhats
b) For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required.
Cost of aluminium fittings complete for doors, windows such as tower bolts, handles, Stoppers and screw etc. for this fittings. (Excluding sliding bolts) ii) For shutter area above 0.50 sqm.
Providing and fixing aluminium sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete. (B) 250mm x 16mm
Removing and refixing of door. (AOR)
Removing of Doors and windows (Steel or wood) with chaukhats by making recesses in walls when the wall is not to be dismantled. (a) Doors of area 3 sqm and below
Chaukhats of commercial hard wood such as Hollock confirming to ISI Specification no 1003 m kiln seasoned of doors and windows including iron hold fasts, corner straps cleats, stops, bolts for hold fasts etc. complete fixed in position (Section 60mm x 150mm) (A) Double rebate (60mm x100mm)
Hollock wood doors shutter windows shutter including hinges, screws, chocks, cheats, stops cards etc. complete fixed in position. (a) Battened and framed (single leaf) (iì) 45mm thick
Wire gauge Hollock wood door shutter without springs housed in chaukhats. (b) 30mm thick
Wire gauge fixed on chaukhats with 25mm thick Hollock wood cover molding of full width.
DISMANTLING WIRING POINTS & FITTINGS: Dismantling old wiring points including necessary repairs to wall etc:-
(i) Fan, Light, Call bell point
(ii) Wall socket, power plug point
SURFACE PVC CONDUIT PIPE WIRING SYSTEM WITH FLUSH PIANO TYPE SWITCHES:- Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100 volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia (ISI Marked) installed on surface etc., complete with PVC boxes (Plastic on surface boxes) required for having (Flush/ Piano type accessories) Step type electronic fan regulators 100watts (socket size), bell push, 5Pin 6Amp. (4Module Box), 16Amp. universal sockets (6Module Box), 6/16/20Amp. Switches etc. and covered with brown bakelite white glazed translucent backside painted sheet 3mm thick etc., PVC connector (For Fan Box and Call Bell), MS saddle clamp, PVC Circular junction Boxes (Four way 1½" deep for walls), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material and painting as required:-
Wiring fan point (Without fan box)
Wiring light point
Wiring 6Amp. wall socket point
Wiring 16/20Amp. power plug control point
SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/RCBO/RCCB's:- Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- (vi) TP&N Horizontal Double Door Distribution Board 6 way each.
MINIATURE CIRCUIT BREAKERS/RCBO'S/RCCB'S:- Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-
MCB Single Pole 6-32amp. (10kA, Curve-C)
RCCB's: Supply and erection of RCCB (Residual Current Circuit Breaker) for Earth leakage protection suitable for 240/415 volts 50 cycles AC supply with breaking capacity of 10kA as per IEC 61008-1 in the existing MCB distribution board as per PWD General specifications including connections with suitable size of thimbles /lugs:- RCCB Four Pole 63amp., Sensitivity 100mA
Bidder Name
Amount in Words
the budhawar co op l and c society ltd
EXPERTECH CONSULTANTS
the budhawar co op l and c society ltd
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .