Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 CrAccepted-AOC | ₹1.9 Cr | L1 | Accepted-AOC Accepted being L1 |
| 2 | L2₹1.9 Cr+₹5.7 L (3.08%)Rejected-Finance S NO 41 4K JAIHIND SOCIETY GANESH NAGAR NEAR ANAND PARK VADGAON SHERI PUNE 411 014 | PUNE | PUNE | MAHARASHTRA | 411014 | ₹1.9 Cr+₹5.7 L (3.08%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹2.0 Cr+₹11.8 L (6.38%)Rejected-Finance | ₹2.0 Cr+₹11.8 L (6.38%) | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹2.0 Cr+₹12.3 L (6.66%)Rejected-Finance | ₹2.0 Cr+₹12.3 L (6.66%) | L4 | Rejected-Finance Not being L1 |
Tender Value
₹1.9 Cr
EMD Value
₹2.6 L
Closing Date
31 May 2023, 6:00 pmClosed
Chief Engineer AF Bangalore
Chief Engineer AF Bangalore No. 2 DC Area MES Road Yeshwantpur Post Bangalore 560022
CONSTRUCTION OF TECHNICAL STORE, CONTROL ROOM, TOILET BLOCK AND CONNECTED ITEMS FOR WORK SERVICES FOR ALTERNATE VENUE FOR PARADE GROUND AT AFA HYDERABAD
2023_MES_581853_2
801582/A/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AFA) HYDERABAD
B Class cat a i
8 documents required · 8 mandatory
₹1,000
GE (AFA) Hyderabad
₹2.6 L
Yes
17 Jun 2023
26 Apr 2023
7 Jun 2023
26 Apr 2023
31 May 2023
10 May 2023
Amount
Schedule 'A' Part - I (B/R Works) Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft / loose soil complete all as specified and as directed
Material and labour for excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. not exceeding 10 sqm on plan and getting out in Hard / Dense Soil complete all as specified and as directed.
All as per item No.2 above but depth exceeding 1.50 m but not exceeding 3.0m
Returning, filling in with excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed.
Removing excavated material (soil) to a distance exceeding 1.5 Km but not exceeding 5Km and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
Material and labour for providing Plain Cement concrete Type D2 1:4:8 (40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
Material and labour for providing RCC M-25 (Design Mix) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; complete all as specified and as directed.
Material and labour for providing RCC M-25 (Design Mix) as in Columns, pillars, piers, posts and struts complete all as specified and as directed.
Material and labour for providing RCC M-25 (Design Mix) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
Material and labour for providing RCC M-25 (Design Mix) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
Material and labour for providing RCC M-25 (Design Mix) as in Chajjas complete all as specified and as directed.
Material and labour for providing RCC M-25 (Design Mix) as in stairways (except spiral staircases) including steps (square or spandril), string pieces, carriages, etc., complete, any section straight or winding, but excluding landings all as specified and as directed.
Material and labour for providing RCC M-25 (Design Mix) as in Fins, fascias, louvers, parapets, and railings exc. 60cm in height, newels, balustrade, and the like all as specified and as directed.
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces of concrete flat complete all as specified and as directed.
Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions square, rectangular or polygonal for rough finished surfaces of concrete complete all as specified and as directed.
Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. for rough finished surfaces of concrete flat complete all as specified and as directed.
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for rough finished surfaces of concrete flat complete all as specified and as directed.
Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide for rough finished surfaces of concrete complete all as specified and as directed.
Use and waste of formwork to chullah hoods, chajjas, troughs and similar items including edges for rough finished surfaces of concrete flat all as specified and as directed.
Use and waste of formwork to staircases with sloping or stepped soffits including risers and stringers (excluding landing) for rough finished surfaces of concrete flat all as specified and as directed.
Use and waste of formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter for rough finished surfaces of concrete flat all as specified and as directed.
Material and labour for providing AAC (Autoclaved Aerated Concrete) block masonry for 200 mm thick walls, with blocks size 600 mm x 200mmx200 mm having compressive strength as per IS 2185 (Part III) and set in chemical mortar of LATICRETE or equivalent as per manufacturer’s instructions complete all as specified and directed.
Material and labour for providing AAC (Autoclaved Aerated Concrete) block masonry for 100 mm thick walls, with blocks size 600 mm x 200mmx100 mm having compressive strength as per IS 2185 (Part III) and set in chemical mortar of LATICRETE or equivalent as per manufacturer’s instructions complete all as specified and directed.
Material and labour for providing 60 mm thick precast cement concrete louvres and jallies, (measured solid), including all mouldings but excluding frame (Pre cast frame shall be measured separately) with PCC 1:2:4 type B-0 using 12.5 mm graded crushed stone aggregate set in cement mortar 1:4 complete all as specified and as directed.
Material and labour for Mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia all as specified and as directed.
Material and labour for Mild steel TMT bars 6mm to 8mm dia cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia all as specified and as directed.
All as per item No. 26 above but as in stirrups, spaces etc
Material and labour for rendering 10 mm thick on fair faces of brick work or concrete wall surfaces in CM 1:6 surface finished even & smooth without using extra cement complete all as specified and as directed.
Material and labour for rendering 5 mm thick on fair faces of brick work or concrete ceiling surfaces in CM 1:3 finished even & smooth without using extra cement complete all as specified and as directed.
Material and labour for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished fair and even using WPC complete all as specified and as directed. (WPC shall be measured and paid separately).
Supply only Integral waterproofing compound of approved make.
Material and labour for Roof treatment for in-accessible roof as under: - (i) Preparation of surfaces by removing all dust, loose particles of RCC slab. (ii) Apply polyurethane waterproofing coating on prepared concrete surface of roof slab & up to 300 mm of parapets and crumple joint including junction of roof and parapet. This stage shall be passed by the GE. Roof surface shall be left without any further treatment. (ii) Method: Cleaning the surface and applying FOSROC Nitoproof 725 (minimum 0.8 mm dft) over a priming coat of Nitoproof WB primer or equivalent product of Asian paints, M/s MC Bauchemic / CIPY / SIKA / Pidilite Dr Fixit / Thermax / STP applied as per manufacturer’s instructions. (iv) The work shall be carried out complete as per manufacturer’s specifications and application methodology. Execution to be done with authorised trained / skilled applicator of manufacturer as per technical guidance laid by manufacturer. Company bank guarantee to be given by contractor after completion of water proofing work before payment.
Material and labour for Roof treatment for accessible roof as under: - (i) Preparation of surfaces by removing all dust, loose particles of RCC slab. (ii) Apply polyurethane waterproofing coating on prepared concrete surface of roof slab & up to 300 mm of parapets and crumple joint including junction of roof and parapet. This stage shall be passed by the GE. (iii) Method: Cleaning the surface and applying FOSROC Nitoproof 650 PU over a priming coat of Nitoproof WB primer or equivalent product of Asian paints, M/s MC Bauchemic / CIPY / SIKA / Pidilite Dr Fixit / Thermax / STP applied as per manufacturer’s instructions. (iv) Further provide a polypropylene / polyester, nonwoven geotextile fabric of 150 gsm followed by cement screed 15 mm in CM 1:4 in slope, over 600x600 mm size, 10 mm heavy duty vitrified ceramic tiles are laid. While laiting tiles, care should be taken to see that joints between tiles are kept minimum and joints are thoroughly filled with FOSROC Nototile grout polymer based joint mortar or equivalent products of Asian paints / M/s MC Bauchemic / CIPY / SIKA / Pidilite Dr Fixit / Thermax / STP applied as per manufacturer’s instructions (v) The work shall be carried out complete as per manufacturer’s specifications and application methodology. Execution to be done with authorised trained / skilled applicator of manufacturer as per technical guidance laid by manufacturer. Company bank guarantee to be given by contractor after completion of water proofing work before payment.
Material and labour for anti-termite treatment, treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and as directed
Material and labour for anti-termite treatment, treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface all as specified and as directed
Material and labour for anti-termite treatment, treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area all as specified and as directed
Material and labour for anti-termite treatment, treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall all as specified and as directed
Material and labour for applying two coats of Oil bound distemper on walls including preparation of new plastered surfaces over a coat of alkali resistant primer over applying 3 mm thick wall care putty complete all as specified and as directed.
Material and labour for applying two coats of Oil bound distemper on ceilings including preparation of new plastered surfaces over a coat of alkali resistant primer over applying 3 mm thick wall care putty complete all as specified and as directed.
Material and labour for preparing newly plastered surfaces of walls and applying two coats of cement based paint over a priming coat complete all as specified and as directed.
Material and labour for providing Hardcore with broken stone or boulders of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and as directed.
Material and labour for providing 100 mm thick Plain Cement concrete Type D2 1:4:8 (40 mm graded crushed stone aggregate) as in sub base flooring complete all as specified and as directed.
Material and labour for providing 25 mm thick plain cement concrete, type B-1, 1:2:4 (20mm graded crushed stone aggregate) as in floor finish concrete complete all as specified and as directed.
Material and labour for laying 600x600mm size, 10 mm thick Vitrified Ceramic tiles non-skid / matt finish tiles of any shade, double charged in floors, set and jointed in neat cement slurry and pointed in white cement mixed with matching pigment over and including 15 mm thick screed bed in CM 1:6 complete all as specified and as directed.
Material and labour for laying 600x600mm size, 10 mm thick Vitrified Ceramic tiles non-skid / matt finish tiles of any shade, double charged in skirting, set and jointed in neat cement slurry and pointed in white cement mixed with matching pigment over 10 mm thick rendering as in screed complete all as specified and as directed.
Material and labour for laying glazed ceramic tiles in vertical surface 600x 300x 7-8 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10 mm thick screed plaster in cement mortar 1:4 complete all as specified and as directed.
Material and labour for polished machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over and including 20 mm thick screed in cement mortar 1:6 complete all as specified and as directed.
Material and labour for polished kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over and including 10 mm thick rendering as screed in cement mortar 1:4 complete all as specified and as directed.
Material and labour for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
Material and labour for providing 75 mm thick Plain Cement concrete Type C-1 1:3:6 (20 mm graded crushed stone aggregate) as in plinth protection laid in alternate bays not exceeding 2 Sqm each and finished fair on top without using extra cement. 6mm wide joints shall be provided throughout the thickness of plinth protection in concrete bays. All joints in bays of concrete, shall be filled with mastic filling comprising of one part of heated bitumen Vg-30 grade and 3 parts of sand (all by weight). all as specified and as directed.
Supply and fix Factory made solid PVC Moulded door shutter with particle board core , 28 to 30 mm thick (stiles), with 2,4 or 6 raised panel design with 2mm thick moulded PVC sheet on the front face and 2 mm plain colour PVC sheet on back face, supplying and fixing in frame at site as per specification and as directed.
Supply and fix Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification and as directed.
Supply and fix 100 mm size Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and as directed.
Supply and fix 150 mm size Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed.
Supply and fix 250 mm size Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed.
Supply and fix 150 mm size Aluminium handles, cast type, anodised complete all as specified and as directed.
Supply and fix Anodised aluminium powder coated (minimum thickness of powder coating 50 micron frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
Supply and fix Anodised aluminium powder coated of any colour (Thickness or powder coating not less than 50 micron). door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and as directed.
Supply and fix powder coated aluminium window and ventilator shutters of any type, description with using standard aluminium sections as per manufacturer's recommendations, including necessary fixing cleats, locking plates, handles, latches, rollers snap beading, glazing clips, rubber neoprene packing, screws etc complete all as specified and as directed. (All aluminium sections and fittings shall be measured for payment purpose and other non aluminium items like neoprene packing, rubber beading, screws, rollers etc shall be deemed included in the rate quoted by the contractor).
Supply and fix 5.5 mm thick Sheet glass, ordinary quality and glazing with aluminium beads (excluding beading) in square not exceeding 0.5 sqm in each pane complete all as specified and as directed.
Supply and fix 4 mm thick Figured glass, pin head type and glazing with aluminium beading in squares not exceeding 0.5 sqm in each pane complete all as specified and as directed.
Supply and fix 12 mm thick Toughened glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required complete all as specified and as directed.
Supply and fix Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and as directed.
Supply and fix vitreous china wash down water closet (pedestal pattern) white (excluding fixing bolts, flushing cistern ) with plastic water closet seat including fixing of flush pipe to pedestal pan including all joints complete all as specified and as directed.
Supply and fix 10 ltr capacity PVC valve less, syphonic action type flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and as directed.
Supply and fix Vitreous China wash basin, white, oval type, size 550x440mm excluding taps, waste, chain and plug and porcelain stopper oval type but including brackets CP waste coupling (flat back or angle back type) any size and 32mm dia waste pipe, including cutting for and pinning in ends of brackets or erecting stand including waste pipe complete all as specified and as directed.
Supply and fix 15 mm bore Two way Bib taps, fancy type chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed.
Supply and fix 15 mm bore Pillar taps fancy type , cast copper alloy fancy type, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed.
Supply and fix 15 mm bore stop valves/angle cock chromium plated with long shank and cup (concealed type) fancy type cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and as directed.
Supply and fix Vitreous China urinals, half stall type (excluding flushing cistern, flush pipe and waste pipe) including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing of grating and Union for discharge pipe, complete all as specified and as directed.
Supply and fix Vitreous china urinal partition white of size 310x700 mm complete all as specified and as directed.
Supply and fix Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and as directed.
Supply and fix PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and as directed.
Supply and fix Toilet paper holder with flat recessed type stainless steel complete all as specified and as directed.
Supplying and laying of CPVC pipes outer dia 20 mm, SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed.
Supplying and laying of CPVC pipes outer dia 25 mm, SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed.
Supplying and laying of CPVC pipes outer dia 32 mm, SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed.
Supply and fix triple layer 1000 lit capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and as directed.
Supply and fix 15 mm bore Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed.
Supply and fix UPVC (SWR) pipes of 110mm dia single socketed in any length with rubber ring joints fixed to walls / floor including connections complete all as specified and as directed
Supply and fix UPVC (SWR) pipes of 75 mm dia single socketed in any length with rubber ring joints fixed to walls / floor including connections complete all as specified and as directed
Supply and fix 110 mm bore UPVC (SWR) bends any radius complete all as specified and as directed.
Supply and fix 75 mm bore UPVC (SWR) bends any radius complete all as specified and as directed.
Supply and fix UPVC 110 mm bore (SWR) junction single, (Single T) equal or unequal complete all as specified and as directed.
Supply and fix UPVC (SWR) vent cowl 110 mm bore complete all as specified and as directed.
Supply and fix 75mm dia UPVC (SWR) floor trap, plain with grating including jointing with solvent cement all as specified and as directed.
Supply and fix UPVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and as directed.
Supply and fix Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and as directed.
Supply and fix Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
Supply and fix Steel rolling shutters, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type with thickness of laths 1 mm complete all as specified and as directed.
Material and labour for preparation of new or previously untreated surfaces of steel and iron surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Use and waste of formwork to fins, louvers, fascia for rough finished surfaces of concrete flat all as specified and as directed.
Material and Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and as directed.
Supply and fix Armstrong Ceiling Classic Lite or equivalent approved make 600x600x16mm, NRC-0.55, with grid size 600x600mm consisting of main tee 32x24mm @1200 c/c, cross Tee of 1200mm of size 27x24 mm and cross Tee of 600mm of size 25x24 mm and wall angle of size 19x19mm and fixed all around the wall to form a grid of size 600x600 ceiling tiles shall be inserted in the formed grid and suspended with 2mm GI wire at every 1200mm intervals C/C all as per manufactures instruction and as directed.
Schedule 'A' Part - I (E/M Works) INTERNAL ELECTRIFICATION Material and labour for point wiring with 1.5 Sqmm copper conductor unsheathed, multistranded, PVC insulated, single core cable FRLS with earth continuity conductor of 1.5 sqmm PVC insulated copper conductor and including rigid PVC concealed conduit of suitable size but not less than 20mm dia. and all accessories fixed to be consealed in wall & surface of the roof etc., including modular type terminal boxes made out of Galvanised sheet of thickness should be not less than 0.9mm thick for fixing of modular switches, modular fan regulators, modular socket outlet etc alongwith suitable modular plate and frame for housing switches, etc complete all as specified and as directed.
(a) One light point controlled by one switch
(b) One light point controlled by two, two way switches
(c) One ceiling/Exhaust fan/Wall Fan point controlled by one switch
(d) One three pin socket 6 Amps plug point independent
(e) One three pin socket 6 Amps plug point on same board
All as per Ser item No 96 above but with 2.5 sqmm copper cable in and including PVC conduit complete all as specified and as directed for 16A socket.
Supply and fix ceiling rose, three terminal, PVC/polycarbonate, insulated body, ISI marked complete all as specified and as directed.
Supply and fix Modular Switch 1 way 1 module polycorbonate white, 6A, 240Volts complete all as specified and directed.
Supply and fix Modular Switch 2 way 1 module polycorbonate white, 6A, 240Volts complete all as specified and directed.
Supply and fix Modular Switch 1 way 1 module polycorbonate white, 16A, 240Volts complete all as specified and directed.
Supply and fix Modular Socket, 6A - 2/3 pin combined 2 module, 240Volts complete all as specified and directed.
Supply and fix Modular Socket 6A/16A - 2/3 pin combined 2 module, 240Volts complete all as specified and directed.
Supply and fix decorative LED mirror light fitting 17 watt surface mounting/wall mounted, including all accessories internally pre-wired, connecting up with twin core twisted flexible copper conductor cable white colour with suitable size complete all as specified and directed by Engineer-in-Charge. Make Philips -Model Ultron or equivalent approved make.
Supply and fix LED ceiling light fitting 15 Watt recessed mounting with white coated die cast housing and diffuser including all accessories internally pre-wired, connecting up with twin core twisted flexible copper conductor cable white colour with suitable size complete all as specified and directed by Engineer-in-Charge. Make Bajaj Category reference - BGSLO Sleek Recess Rd 15 W LED or Equivalent approved make.
Supply and fix LED fitting 36 Watt recessed mounting 2 ft x 2ft luminaire white powder coated CRCA housing seamless front frame with flat white high transmission acrylic cover including all accessories for mounting internally pre-wired, connecting up with three core twisted flexible copper conductor cable complete all as specified and directed by Engineer-in-Charge. Make Bajaj Category reference - BZRSQL 43 W GZI WH or Equivalent approved make.
Supply and fix surface mounting/wall mounted LED tube light fitting 20 watts high efficiency, anti glare, maintenance free operation including LED driver and mounting arrangements, all accessories internally pre-wired, connecting up with twin core twisted flexible copper conductor cable white colour with suitable size complete all as specified and directed by Engineer-in-Charge. Make Bajaj Model BCLSB 20 W WH or equivalent approved make.
Supply and fix surface mounting/wall mounted LED bulk head light fitting 10 watts PDC housing LED bulk head luminaire with Opal diffuser, equipped with 2 kV in built surge protection with IP 65 protection rating, maintenance free operation including LED driver and mounting arrangements, all accessories internally pre-wired, connecting up with twin core twisted flexible copper conductor cable white colour with suitable size complete all as specified and directed by Engineer-in-Charge. Make Bajaj Model BIBWP 10 W LED or equivalent approved make.
Supply and fix security light luminaries 30 W with pressure die-cast housing along with prismatic polycarbonate modular secondry lens optics with IP 66 ingress protection. 4 kV in built surge protection with top opening driver cover for easy maintenance complete all as specified and directed. Make Bajaj Model ENXT P 36L WH CR PC SD W LED or equivalent approved make.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, sweep 250 mm including louvers and making good with matching colour with the surroundings provision of cable 3 core of size 0.5 Sqmm (16/0.2 mm) from ceiling rose to fan, all as specified and as directed. Make -Havells -Model Ventilair DX or Equivalent approved make.
Supply and fix wall mounted fans 230 volts single phase oscillating 450 mm sweep jerk free oscillation and smooth running, with thermal overload protector (TOP), suitable for wall mounting including all necessary fixing accesssories kit and arrangements all as specified and directed by Engr-in-Charge. Make: Havells, Model V3 or equivalent approved make.
Supply and fix security light brackets of GI pipe medium grade 40mm upto 1.5 mtr long bend to shape at 100-120 degree including arrangement of fixing at chanel/anglel with the help of flat iron clamps and suitable nuts and bolts including all material required for fitting, including weiding and drilling hole inclusive of one primer coat, one under coat and one finishing coat of paint all as specified and directed.
Material and labour for Sub Main wiring with 2x6 Sqmm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through medium grade, rigid non-metallic PVC conduit of size 25mm or higher suitable size with all necessary fittings, concealed in walls/roof/floor duly earthed with 1X6 Sqmm of single core cable but green in colour as continuous earthing wire and connecting to common earth dully complete all as specified and directed. Note :- Two runs of 6 sqmm PVC insulated copper cable and one run of earth continuity conductor and one run of PVC Conduit shall be measured as one unit length / running meter.
Material and labour for Sub Main wiring with 2x10 Sqmm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through medium grade, rigid non-metallic PVC conduit of size 25mm or higher suitable size with all necessary fittings, concealed in walls/roof/floor duly earthed with 1X10 Sqmm of single core cable but green in colour as continuous earthing wire and connecting to common earth dully complete all as specified and directed by Engineer-in-Charge. Note :- Two runs of 10 sqmm PVC insulated copper cable and one run of earth continuity conductor and one run of PVC Conduit shall be measured as one unit length / running meter.
Supply and fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB 20 Amps capacity complete all as specified and as directed.
Supply and fix single phase modular type motor starter 32 A, 240 Volts, 50 Hz for split AC including cover plate and PVC surface box of suitable size complete all as specified and as directed.
Supply and fix MCCB DB 4 way triple pole vertical type 415 volts 50 Hz AC supply including suitable provision for 4 pole MCCB incomer, fixed to the existing wall (concealed) and making good the disturbed surface of wall with the existing wall complete all as specified and as directed.
Supply and fix MCCB 4 pole 63Amps, 16KA breaking capacity, 415Volts 3-phase supply complete all as specified and directed.
Supply and fix MCB DB 12 way SPN double door powder coated, 230volts 50 Hz AC supply including fixing to the wall (concealed/surface) and making good the disturbed surface wall with the exsting wall complete all as specified and as directed.
Supply and fix MCB SP 5 to 32 amp 240V, 10 KA 'C' curve in the MCB DBs Complete with connection testing and commissioning complete all as specified and as directed.
Supply and fix MCB SPN 32 amp rating 240V, 10KA 'C' curve in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
Supply and fix dummy PVC cover (blanking plates) for existing MCB DBs complete all as specified and as directed.
Material and labour for earthing complete with Galvanised steel earth plate eletrode 600 mm x 600 mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filled in alternate layers and electrode connections by using Galvanised earth wire 4mm dia connected by means of bolts, nuts, check nuts and washer of galvanised iron or steel, provision of 15 mm dia GI pipe medium grade for protection of GI earth wire and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) type C1 chamber, MS funnel, wire mesh, 50 mm thick RCC 1:2:4 type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance not exceeding 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I Note: (i) Cost of GI wire and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returning filling, removing, PCC chamber pit, RCC cover, test point etc.
AIR CONDITIONING Supply and install hi wall split air conditioner units capacity 1.5 TR indoor/outdoor complete with cordless remote control unit and with inbuilt air ioniser and plasma filter to better indoor air quality with minimum 5 star rating complete all as specified and directed.
Supply and fix 4 KVA capacity Voltage stabilizer for automatic operation single phase air cooled indoor type & designed input variation between 130 V to 300 V with output voltage stabilizer at 230 volts with accuracy of +/- 2.5 complete all as directed.
OM INFRA
power links
Dwarka Pershad Radhey Ramanlal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .