Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | l1₹26.4 LAccepted-AOC R O H NO 55 SEC D BHARAT NAGAR TALAB TILLO JAMMU 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | l1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹27.0 L+₹54,800 (2.07%)Rejected-AOC PANTHAL KATRA REASI J K 182320 | REASI | JAMMU AND KASHMIR | 182320 | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹28.8 L+₹2.4 L (9.00%)Rejected-AOC | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹29.7 L+₹3.3 L (12.4%)Rejected-AOC NEW JAIL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹29.8 L+₹3.4 L (12.9%)Rejected-AOC | L5 | Rejected-AOC REJECTED |
Tender Value
₹4 L
EMD Value
₹80,000
Closing Date
22 Jun 2022, 6:00 pmClosed
GE SOUTH UDHAMPUR
GE SOUTH UDHAMPUR
GE S U 10 2022 23 DAY TO DAY MAINTENANCE OF INTERNAL ELECTRIFICATION AT CERTAIN LOCATIONS UNDER AGE E/M OF GE SOUTH UDHAMPUR
2022_MES_526222_1
GE/S(U)-10/2022-23
Open Tender
Civil Works
Works
330 days
GE SOUTH UDHAMPUR
As per NIT documents
9 documents required · 9 mandatory
₹500
GE SOUTH UDHAMPUR
₹80,000
6 Aug 2022
25 May 2022
23 Jun 2022
25 May 2022
22 Jun 2022
8 Jun 2022
25 May 2022 - 3 Jun 2022
Amount
Repairing of unserviceable light point, Fan point, socket point 5A/15A, switches, sockets or regulator, light fixtures any type , any type MCBs, DB's & all electrical accessories in day to day/door to door maintenance and making it serviceable in all respect with all replacement of any major part but including small length of wires upto 2.5 sqmm single core (not more than 50 cm), adhesive tape and other connected accessories like screws & washers etc. Work shall also include to check & removal of breakages in service connection /sub main of houses as and when directed. The scope of work shall also include cutting of existing Bakelite sheet to accommodate new wiring accessories like switches, sockets, fan regulators etc complete all as specified and as directed. (Note: Any major items required to be replaced for this job will be measured and paid under Relevant items of this schedule except Item No 23 to 27, 32, 40 to 53, 55, 56,57 and 79).
Note : (a) Contractors representative/engineer will report to JE E/M/Engr-in-charge daily at fore noon and after noon to collect routine/urgent works related to internal electric supply till completion of contract. The contractor will ensure availability of manpower equipped with all sort of petty items such as insulation tape, galvanised screws, nuts, bolts, washers etc required to accomplish the job including every type of requisite T&P items to his trades man. All routine/urgent jobs received on job slip will be repaired & got signature of user's and will be deposited to JE E/M with in 24hrs. In case of any delay in attending the complaint more than 8 hrs after handing over of routine and 2 hrs for urgent works, the contractor shall be liable to pay the penalty as described in penalty clause given here as under.
(b) The penalty shall be applicable to the contractor if the delay is noticed by the Engineer-in-Charge more than twelve hrs after handing over works of urgent nature to the contractor. The Engr-In-Charge/ JE E/M shall handover the slip containing specification of work to the contractor. The contractor shall attend the job immediately and report to Engr-In-Charge within 12hrs. The contractor will keep his trades men in stand by for attending any routine/urgent works from the executive. If the nature of job is such that the work cannot be completed within period of 12hrs then the facts shall be brought to the notice of the GE/Engr-in-charge and the period for the working to the complaint shall be decided by the GE/EIC. If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 20 per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other then the condition 56 of IAFW –2249 and shall be treated as interim condition of the contract and shall enforceable as and delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt. The decision of the Accepting Officer is this regard shall be final and binding.
(c) One Complaints slip to be treated as One Complaint irrespective of No. of Repairs mentioned in the same.
(d) Contractor to keep his Electrician ready for Urgent Complaints, During odd hours ( 0600 Hrs to 0900 Hrs and 1700 Hrs to 2200 Hrs ) Other than the Regular complaints during working Hrs ( 0900 Hrs to 1700 Hrs )
(e) Procurement of Security gate passes of the Electrician , will be sole responsibility of the Contractor
(f) If the work is repeated due to poor workmanship, he will be liable to repair the same without any extra expenditure to the govt.
Switch piano flush type SP, one way 5 Amps including taking down old one complete all as specified and as directed.
Switch piano flush type SP, one way 15 Amps including taking down old one complete all as specified and as directed.
Switch socket combination 2 in 1 5 Amps, flush type including taking down old one complete all as specified and as directed.
Switch socket combination 5A/16 Amps, 5 in 1 including taking down old one complete all as specified and as directed.
Socket outlet 2 in 1, 5 pin, 5 Amps including taking down old one complete all as specified and as directed.
Socket outlet, 2-in-1, 5 pin, 5 and 15 Amps flush type combined including taking down old one complete all as specified and as directed.
Two way switch 5 Amps,230 volts including taking down old one complete all as specified and as directed.
Ceiling rose, surface bakelite 65mm x 50mm, 3 terminals fixed on PVC Round Block including complete all as specified and as directed.
Angle lamp holder PVC/Polycarbonate with back plate suitable for fittings including taking down old one complete all as specified and as directed.
Bell push 230 volts, AC including taking down old one complete all as specified and as directed.
Call bell ding-dong 230 volts including taking down old one complete all as specified and as directed.
Switch modular type, 1 module, 6 Amps one way including taking down old one complete all as specified and as directed.
Switch modular type, 1 module, 16 Amps one way including taking down old one complete all as specified and as directed.
Socket outlet modular type, 2 module, 3 pin, 6 Amps combined including taking down old one complete all as specified and as directed.
Socket outlet, modular type, 2 module, 2-in-1, 6/16 Amps combined including taking down old one complete all as specified and as directed.
Two way switch modular type, 1 module, 6 Amps including taking down old one complete all as specified and as directed.
Bell push with indicator modular type, 1 module,6A, including taking down old one complete all as specified and as directed.
Fan regulator modular type, 2 module, step type,120 watts complete all as specified and as directed.
Fan electronic dimmers/ Socket type 450W, 250V flush type on the existing laminated sheet complete all as specified and as directed.
Switch - socket combination 5 Amps,5 pin multipurpose with PVC Box, 4 holes complete all as specified and as directed.
Switch - socket combination 15 Amps, 6 pin multipurpose with PVC Box, 4 Holes complete all as specified and as directed.
Sheet metal enclosure MCB distribution board single pole & neutral 240 volts 12 way double door complete with appropriate size bus bar,neutral link and Earth Bar fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and as directed. (Note - MCBs will be measured separately.)
Sheet metal enclosure MCB distribution board single pole & neutral 240 volts 8 way with double door complete with appropriate size bus bar, neutral link and Earth Bar fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and as directed. (Note-MCBs will be measured separately.)
Sheet metal enclosure MCB distribution board single pole & neutral 240 volts 4 way with double door complete with appropriate size bus bar, neutral link and Earth Bar fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and as directed. (Note-MCBs will be measured separately.)
Sheet metal enclousers ,TPN Distribution board 4 way, double door complete with appropriate size bus bar, neutral link and Earth Bar fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and as directed. (Note-MCBs will be measured separately.)
VTPN MCCB DB Double Door (Including 63 Amp MCCB) 16 KA (as incommer) 4 way double door complete with appropriate size bus bar, neutral link and Earth Bar fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and as directed.
MCB Single Pole, 230 Volt, B-Series, Rating 6 to 32 Amps complete all as specified and as directed.
MCB Single Pole and Neutral , 230 Volt, B-Series, Rating 40A as Incoming in MCB SPN DB complete all as specified and as directed.
MCB Single Pole and Neutral , 230 Volt, B-Series,Rating 63A as Incoming in MCB SPN DB complete all as specified and as directed.
MCB Three Pole and Neutral , 230 Volt,Rating 63A as Incoming in MCB TPN DB complete all as specified and as directed.
Earthing complete with galvanised steel earth plate electrode of size 600mm x 600mm x 6mm thick as earth electrode burried directly in ground earth plate not less than 2.25m deep below normal ground level with top edge of earth plate not less than 1.5 m below ground level connected to and including galvanised steel earth lead wire 4mm dia as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed inculding providing earth wire protection pipe GI light grade 15mm dia from earth plate to main switch board / panel , watering pipe 20mm dia with mesh and funnel at top , earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of characoal dust and salt all around the earth plate , earth work in any type of soil, removing surplus excavated material all as required at site and specified in electrical plate No 3 of SSR part I 2009 complete all as specified and as directed.
LED tube light fitting Garnet 20W Batten LED, Housing made of extruded PC with lumen O/P should not be less than 100 lumen/watt making all connection using flexible cable of suitable size from ceiling rose to fitting including taking down old one complete all as specified and as directed.
LED tube light fitting Garnet 10W Batten LED, Housing made of extruded PC with lumen O/P should not be less than 100 lumen/watt making all connection with suitable size flexible cable from ceiling rose to fitting including taking down old one complete all as specified and as directed.
LED tube light fitting Garnet 5W Batten LED, Housing made of extruded PC with lumen O/P should not be less than 100 lumen/watt making all connection with suitable size flexible cable from ceiling rose to fitting including taking down old one complete all as specified and as directed.
LED 10 watt Bulk Head Light energy saving with IP-65 with opal diffuser , pressure die cast aluminium housing and making all connection with suitable size flexible cable from ceiling rose to fitting including taking down old one complete all as specified and as directed.
LED Panel light 2'x2' capacity 36 Watt extruded aluminium housing with milky diffuser recess mounting ultra modern desinged architectural LED luminaire which provides soft-light and glare free symmetrical illumination suitable for Armstron/Grid ceiling including driver 36 Watt capacity complete making all connection with suitable size flexible cable from ceiling rose to fitting including taking down old one complete all as specified and as directed.
LED Panel light 2'x2' capacity 36 Watt, extruded aluminium housing with milky diffuser surface mounting ultra modern desinged architectural LED luminaire which provides soft-light and glare free symmetrical illumination including driver 36 Watt Capacity complete making all connection with suitable size flexible cable from ceiling rose to fitting including taking down old one complete all as specified and as directed.
Driver for 2'x2' LED Panel with all necessary fixing arrangement including taking down old one complete all as specified and as directed.
Taking down carefully (copper/aluminum) point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants, ceiling rose, round block etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and as directed.
Point wiring for one light /fan/ Bell point controlled by one switch with 1.5 sqmm PVC insulated FRLS unsheathed copper conductor single core multi stranded flexible copper cable 1100V grade in and including not less than 2.00 mm thick and 20 mm dia Non metallic Rigid PVC surface/Concealed Conduit ( ISI marked ) and 1.5 mm thick mild steel terminal boxes concealed on walls, painting the same inside and out side with one coat of black bitumen paint with 3mm thick hylam brand bakelite sheet cover for fixing of piano switches/sockets/ regulator etc along with PVC insulated and unsheathed FRLS 1.5 Sqmm multi stranded copper conductor cable (green color) as earth lead, & connected to common earth and earth dolly, making good the disturbed surface to match with the existing specification complete all as specified and as directed.
All as per Item No.41 but for one light point controlled by two nos two way switches on independent Board with 1.5 Sqmm size of copper cable complete all as specified and as directed.
All as per Item No.41 but for 3 pin 5 Amp Socket outlets point controlled by one switch 5A piano type on Same board with 1.5 Sqmm size of copper cable complete all as specified and as directed.
All as per Item No. 41 but for 3 pin 5 Amp Socket outlets point controlled by one switch 5A piano Type on Independent board with 1.5 Sqmm size of copper cable complete all as specified and as directed.
All as per Item No.41 but for 3 pin 15A socket outlet point controlled by one switch 15A on the independent Board with 2.5 Sqmm size of copper cable complete all as specified and as directed.
Point wiring for one light /fan/ Bell point controlled by one switch with 1.5 sqmm PVC insulated FRLS unsheathed copper conductor single core multi stranded flexible copper cable 1100V grade in and including not less than 2.00 mm thick and 20 mm dia Non metallic Rigid PVC surface/Concealed Conduit ( ISI marked ) and 1.25 mm thick mild steel terminal boxes (Modular Type) concealed in wallsfor fixing of modular switches/sockets/ regulator etc along with PVC insulated and unsheathed FRLS 1.5 Sqmm multi stranded copper conductor cable (green color) as earth lead, & connected to common earth and earth dolly, making good the disturbed surface to match with the existing specification complete all as specified and as directed.
All as per Item No. 46 but for one light point control by two nos two way modular switches on independent Board with 1.5 Sqmm size of copper cable complete all as specified and as directed.
All as per Item No.46 but for 3 pin 5 Amp Socket outlets point controlled by one modular switch 6A piano type on Same board with 1.5 Sqmm size of copper cable complete all as specified and as directed.
All as per Item No.46 but for 3 pin 5 Amp Socket outlets point controlled by one modular switch 6A piano Type on Independent board with 1.5 Sqmm size of copper cable complete all as specified and as directed.
All as per Item No.46 but for 3 pin 15A socket outlet point controlled by one modular switch 16A on the independent Board with 2.5 Sqmm size of copper cable complete all as specified and as directed.
Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 10 Sqmm drawing through existing surface / recessed steel/ PVC conduit of any type and size including PVC insulated copper conductor cable 6 Sqmm as earth lead all as specified including taking down old sub main wire complete all as specified and as directed.
Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 6 Sqmm drawing through existing surfacce / recessed steel/ PVC conduit of any type and size including PVC insulated copper conductor cable 4 Sqmm as earth lead all as specified including taking down old sub main wire complete all as specified and as directed.
Sub main wiring with four single core PVC insulated with copper conductor cable stranded of size 6 Sqmm drawing through existing surface / recessed steel/ PVC conduit of any type and size including PVC insulated copper conductor cable 4 Sqmm as earth lead all as specified including taking down old sub main wire complete all as specified and as directed.
Fan Capacitor 2.5/3.15 mfd AC, 415 volt complete all as specified and as directed.
Supply, laying, Fixing or passing through pipe 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with an inner sheating of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of size 2 core 6 sqmm nomial cross section in service connection including taking down of old u/s service connection from pole to DB complete all as specified and as directed.
Supply and fixing GI tubing light grade 25 mm dia along the wall/ in trenches/ in duct / in culvert /road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holdining of GI pipe alongwith poles complete all as specified and as directed.
LED street light fitting 25W Garnet with single piece deep drawn Al housing with side reflectors and acrylic cover including fixing arregement in existing bracket complete all as specified and as directed.
Modular plate 1 module including taking down old u/s complete all as specified and as directed.
Modular plate 2 module including taking down old u/s complete all as specified and as directed.
Modular plate 3 module including taking down old u/s complete all as specified and as directed.
Modular plate 4 module including taking down old u/s complete all as specified and as directed.
Modular plate 6 module including taking down old u/s complete all as specified and as directed.
Modular plate 8 module including taking down old u/s complete all as specified and as directed.
1.5 Sqmm PVC insulated FRLS unsheathed copper conductor single core multi stranded flexible copper cable 1100V grade complete all as specified and as directed.
2.5 Sqmm PVC insulated FRLS unsheathed copper conductor single core multi stranded flexible copper cable 1100V grade complete all as specified and as directed.
4.0 Sqmm PVC insulated FRLS unsheathed copper conductor single core multi stranded flexible copper cable 1100V grade complete all as specified and as directed.
2.5 Sqmm PVC insulated FRLS unsheathed copper conductor round three core flexible copper cable 1100V grade complete all as specified and as directed.
PVC casing caping of size 20/25mm including all accessories i.e Nail, tee, elbow etc complete all as specified and as directed.
PVC conduit of size 20/25mm including all accessories i.e Nail, tee, elbow etc complete all as specified and as directed.
PVC flexible cable twisted two core wire of size 14/76 complete all as specified and as directed.
LED engagement 0.5 watt safelite Yellow/Green/Red base cap B22 with all necessary fixing arrangement including taking down old complete all as specified and as directed.
LED 15 Watt Surface Mounting fitting round/square type, Housing made of extruded PC with lumen O/P should not be less than 100 lumen/watt making all connection using flexible cable of suitable size from ceiling rose to fitting including taking down old complete all as specified and as directed.
LED 15 Watt Recess Mounting fitting Round/Square type,Housing made of extruded PC with lumen O/P should not be less than 100 lumen/watt making all connection using flexible cable of suitable size from ceiling rose to fitting including taking down old complete all as specified and as directed.
LED City 3 decorative wall light fixture made up of polycarbonate and including LED 15W Lamp and making all connection using flexible cable of suitable size from ceiling rose to fitting including taking down old one complete all as specified and as directed.
Venza decorative wall mounting light fitting, SS finish fixture with opal glass diffuser including 12W retrofit LED bulb and making all connection using flexible cable of suitable size from ceiling rose to fitting including taking down old complete all as specified and as directed.
Decorative wall light (SANA) made up of high grade engineering plastic material including retrofit LED Bulb 10 watt and making all connection using flexible cable of suitable size from ceiling rose to fitting including taking down old one complete all as specified and as directed.
Decorative wall light (STYLO) fitting, Champagne gold finish fixture with plastic body including 12Watt retrofit LED Bulb and making all connection using flexible cable of suitable size from ceiling rose to fitting including taking down old complete all as specified and as directed.
Decorative wall light (APPLE) fiiting, fixture made up of polycarbonate, including 12 Watt retrofit LED Bulb and making all connection using flexible cable of suitable size from ceiling rose to fitting including taking down old one complete all as specified and as directed.
MCB Three Pole and neutral capacity 100 Amp as incoming in MCB TPN DB complete all as specified and as directed.
Electronic Fan regulator stepped type flush type on the existing laminated sheet complete all as specified and as directed.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB complete all as specified and as directed.
PVC box two holes best quality (ISI marked) for use MCB SPN complete all as specified and as directed.
LED Bulb capacity 10 Watt Warn white model No B-22/E27 complete all as specified and as directed.
LED 06 Watt Recess mounting fitting round/squre type, Housing made of extruded PC with lumen O/P should not be less than 100 lumen/watt making all connection using flexible cable of suitable size from ceiling rose to fitting including taking down old one complete all as specified and as directed.
LED 12 Watt Recess mounting fitting round/squre type, Housing made of extruded PC with lumen O/P should not be less than 100 lumen/watt making all connection using flexible cable of suitable size from ceiling rose to fitting including taking down old one complete all as specified and as directed.
Note : Bidders attention is invited to pages on ser page No 13 & 14 of tender documents.
DEV RAJ MAGOTRA
ARNABH ASSOCIATES
SINGH CONST CO
HIMALAYA ENTERPRISES
m/s shanti trading company
Bansal and Sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .