| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹45.8 LAccepted-AOC | 1 | Accepted-AOC l1 bidder | |
| 2 | 2₹49.9 L+₹1.1 L (2.34%)Rejected-AOC I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | 2 | Rejected-AOC OTHER THAN l1 bidder | |
| 3 | 3₹56.1 L+₹7.4 L (15.2%)Rejected-AOC 271 CIVIL LINE GURUGRAM GURUGRAM GURGAON HARYANA 122001 | GURUGRAM | HARYANA | 122001 | 3 | Rejected-AOC OTHER THAN l1 bidder |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
11 Jan 2020, 6:00 pmClosed
GE SATWARI
GE SATWARI
PROVN OF SPL REPAIR/REPLACEMENT OF LT DISTRIBUTION SYSTEM, LT PANEL, LIGHTS, CI/DI PIPE LINE UNDER GE SATWARI
2019_MES_305649_2
GEJM-71/19-20
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE SATWARI
AS PER TENDER DOCUMENT
9 documents required · 9 mandatory
₹500
GE SATWARI
₹1 L
Yes
1 May 2020
27 Dec 2019
13 Jan 2020
27 Dec 2019
11 Jan 2020
30 Dec 2019
Amount
Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes,cables,pipe line,pole etc. not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out, in any type of soil, complete all as specified and as directed by Engineer-In-Charge.
Taking out existing street light pole/solar light poles to include removal of PCC, excavation and fixing at new location with excavation work complete all specified and directed.
Taking out the existing unserviceable voltmeter, ammeter, phase indication lamps, CTs of any description and size and S&F digital voltmeter, ammeter, phase indication lamps,fCTs as per existing capacity and sizes all as specified and directed. Make :- L& T equivalant in AE / Enercon /Rishab.
Supply and spreading sand Dry cushioning to cable providing with a layer of sand 8cm deep before laying the cable and 15cm deep after laying and stretching the cable in trenches complete all as specified and as directed by the Engineer-in-Charge.
Supply and laying sub class `B` bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid.
Demolition of Cement concrete (unreinforced) in four pole/two pole/HT& LT pole/panel/approach path to sub station n. exc 15 cm thickness (below or above ground level) and removing all the demolished material outside cantt area
Returning filling in, trenches including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil complete all as specified
Removing excavated surplus materials to a distance not exceeding 50mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point Note : During excavation/taking out any damage to the existing services like telephone cable,sewage line,electric cable,water supply pipe will be repaired by the contractor at his own arrangement.No extra payment will be born by the deptt on this account.
Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation for sub base of PCC poles etc complete all as specified and directed
Plain cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in foundation for sub base of PCC poles etc complete all as specified and directed
PCC 1:3:6 type C2 using 40 mm graded crushed stone aggregate infour pole/two pole/HT& LT pole/panel/approach path to sub station.
Taking out Old unsv /broken PCC poles to include removal of PCC, excavation complete all specified and directed.
Supply, laying and testing cable XLPE insulated,screened, PVC bedded galvanised steel strip or wire armoured electric power cable ( heavy duty) 11000 volts grade with stranded aluminium conductor of size 120 Sqmm x 3 core .
Supply, laying and testing cable XLPE insulated,screened, PVC bedded galvanised steel strip or wire armoured electric power cable ( heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm x 2 core .
Supply, laying and testing cable XLPE PVC insulated,screened, PVC bedded galvanised steel strip or wire armoured electric power cable ( heavy duty) 1100 volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 core.
Supply, laying and testing cable XLPE PVC insulated,screened, PVC bedded galvanised steel strip or wire armoured electric power cable ( heavy duty) 1100 volts grade with stranded aluminium conductor of size 240 Sqmm 3.5 core.
Supply and fixing in replacement of Service connection with 6 sqmm twin core weather proof aluminium conductor cable suspended with 8 swg GI wire from pole to service bracket
Supply and fixing in replacement of Service connection with 4 sqmm twin core weather proof aluminium conductor cable suspended with 8 swg GI wire from pole to service bracket
Supply, laying for replacement of unsv underground LT cable size 6 Sqmm 2 core 1100 volts grade heavy duty electric cable PVC insulated and PVC outer sheathing with aluminium stranded conductor armoured confirming to IS 7098 part-I (1988) with latest ammendments of sizes.
Supply, laying for replacement of unsv underground LT cable size 10 Sqmm 2 core 1100 volts grade heavy duty electric cable PVC insulated and PVC outer sheathing with aluminium stranded conductor armoured confirming to IS 7098 part-I (1988) with latest ammendments of sizes.
Supply, laying for replacement of unsv underground LT cable size 10 Sqmm 4 core 1100 volts grade heavy duty electric cable PVC insulated and PVC outer sheathing with aluminium stranded conductor armoured confirming to IS 7098 part-I (1988) with latest ammendments of sizes.
Supply, laying for replacement of unsv underground LT cable size 16 Sqmm 4 core 1100 volts grade heavy duty electric cable PVC insulated and PVC outer sheathing with aluminium stranded conductor armoured confirming to IS 7098 part-I (1988) with latest ammendments of sizes.
Supply, laying for replacement of unsv underground LT cable size 600 Sqmm 1 core 1100 volts grade heavy duty electric cable PVC insulated and PVC outer sheathing with aluminium stranded conductor armoured confirming to IS 7098 part-I (1988) with latest ammendments of sizes.
Supply, laying for replacement of unsv underground LT cable size 50 Sqmm 3.5 core 1100 volts grade heavy duty electric cable PVC insulated and PVC outer sheathing with aluminium stranded conductor armoured confirming to IS 7098 part-I (1988) with latest ammendments of sizes.
Supply and Fixing in replacement of thermoplastics polystyrene/polycarbonate enclosure, shock proof, IP65( weather proof), rust proof, dust proof, water proof, internally embedded gasket with provision for all side cable entry through glands(IP-65) and/or grommets(IP-55). Size of enclosure: ( 102 x 197 x 92 ) mm With suitable connecters for /1Ph loop in loop out and branch out vibration proof connections and fixing on pole with suitable clamps, nut, bolts and washers Make: HENSEL. Cost of PCC/fixing arrangements for pole/wall/platform shall be deemed to be included in the item rates.
Supply and fixing in replacement of bus bar panel made of 2mm thick CRCA sheet with 100 Amps capacity Bus-bar - 4 Nos complete all as specified and directed including necessary MS clamp of flat iron nuts and bolts,fixed in wall/fixed on PCC block of size 30x30x30cm and making all electric connections with fresh lugs,jumpers as per cable size complete all as specified and directed by Engr-in-charge. Note : The cost of PCC will be included in item rate and no extra cost will be provided.
Supply,fixing,testing & commissioning in replacement of ENDURA walkover energy saving 3Watt LED IP66 walkover luminaire silicon gasket,stainless steel outer ring Min IP 66 suitable for downward light distribution. Make:-Jaquar Ordering code LGBL04R301XW and Lamp type 3W LED 3000k complete all as specified and as directed by Engr-in-charge.
Material and labour for complete point wiring with 2.5 Sqmm single core multi stranded copper conductor FRLSH insulated and unsheathed heavy duty cable in colour code including continuous earth wire with cable of size 2.5 sqmm copper conductor flexible FRLSH insulated drawn into & including concealed rigid PVC conduit 1.5mm wall thickness ISI marked terminated into CI/pressed steel terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc incl making good of disturbed surfaces with CM plaster and finishing the surfaces as per the existing finish complete all as specified and as directed by the Engr-in-Charge.
Material and labour for point wiring one light/fan point controlled by one, one way switch 5/6 Amp complete with 1.5 Sqmm single core multi stranded copper conductor FRLSH insulated and unsheathed heavy duty cable in colour code including continuous earth wire with cable of size 1.5 sqmm copper conductor flexible FRLSH insulated drawn in and including concealed PVC rigid conduit medium grade ISI marked after cutting chases in wall , plastering after concealing conduit , terminated into modular galvanised suitable size sunken boxes incl white cover plate with frame as per relevant IS for mounting modular switches, sockets, fan regulators etc complete all as specified and as directed.
Supply and fixing Switch socket combination 2-in-1 5 pin 5 Amps made of polycarbonate flush type complete all as specified and as directed.Make: Anchor PC Penta or equivalent in HPL , Havells
Supply and fixing plug top 5 Amps 3 pins. Make : Anchor/Havells
Supply & fixing in replacement of automatic street light switch using Nature Switch for automatic switching of street lights based on LUX level of natural light the sensor (nature switch) along with suitable power contactors and MCBs (Input-output) should be enclosed in pole/wall mountable enclosure made of rust proof, Electric shock proof, termite proof and FR grade SMC junction box (sintex make) conforming to IP 54.the contactor,MCBs and copper circuit wiring (min.10sqmm) should enough to take: Single-phase load of 5KW;contactor Rating 40Amps; MCB(sp) Rating 40Amps.MAKE:-Nature switch :Kakatiya energy systems pvt.ltd. hyderabad/bajaj/healer. Contactor:- BCH/L&T/Schneider or equivalent (as per IEC-60947-4-1/IS-13947-4-1), MCBs(Input-output):Hager/schneider/L&T/BCH or equivalent (as per IEC-60898/IS-8828),Circuit wiring : Finolex/polycab/RR Kable or equivalent. Model no SWADEEP-02EC5KW1P
S & F connectors PVC complete incl suitable size screws etc for fixing all as specified and directed.
S&F in replacement of PVC wire with two run single core PVC insulated cable copper conductor 1.5 sqmm and 1.5 sqmm for earthing from looping box to street light fitting terminal complete with thimbles all as specified and directed by Engg-in-charge.
Material and labour in replacement of FREEDOM + LED STREET LIGHTS 45W 6000K New generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 with high power LEDs as light source Make : Crompron Model Freedom+ Cat Part No LSTS-45-CDL-1
Material and labour in replacement of PROFILE 30 W LED FLOOD WARM LIGHTS WITH YELLOW SHADE 3000K New generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 with high power LEDs as light source Make : Crompron Model Profile Cat Part No LFLE-30-CDL
Supply and fixing in replacement of LED flood light 70 watt ,3000K yellow light confirming to IS 10322 2012,IP65.Make OPPLE model no LED FL-E 70W.
Dismentiling, taking down unserviceable feeder pillar and Supply, installation, testing & commissioning in renewal of totally enclosed feeder pillar outdoor type fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powder coated double door type (independent cabin including locking arrangement for each MCCBs, bus bar chamber enclosed complete suitable for operating on 415 Volt 50 Hz AC supply internally wired with copper conductor having legs 90 cms made out of 50x50x6 mm angle iron grouted on brick masonary platform upto 45 cms. Brick masonary platform should be 60 cms above the Ground Level. Comprising the following:- .Note:- (i) The panel shall be front operated with cable entry from the bottom with cable glands. Earth bus shall be part of the main feeder pillar. (ii) Fabrication of feeder pillar box to be approved by CPRI width of the panel not less than 75 cms. (iii) Cost for construction of platform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC copping 1:2:4 (40 mm thick stone aggerate), deemed to be included in the item rate. No Extra payment will be made. (iv) MCCB's should be connected with extensions terminals at both side (incoming and outgoing).
Dismentiling, taking down unserviceable feeder pillar and Supply, installation, testing & commissioning in renewal of totally enclosed feeder pillar outdoor type fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powder coated double door type (independent cabin including locking arrangement for each MCCBs, bus bar chamber enclosed complete suitable for operating on 415 Volt 50 Hz AC supply internally wired with copper conductor having legs 90 cms made out of 50x50x6 mm angle iron grouted on brick masonary platform upto 45 cms. Brick masonary platform should be 60 cms above the Ground Level. Comprising the following:- Note:- (i) The panel shall be front operated with cable entry from the bottom with cable glands. Earth bus shall be part of the main feeder pillar. (ii) Fabrication of feeder pillar box to be approved by CPRI width of the panel not less than 75 cms. (iii) Cost for construction of platform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC copping 1:2:4 (40 mm thick stone aggerate), deemed to be included in the item rate. No Extra payment will be made. (iv) MCCB's should be connected with extensions terminals at both side (incoming and outgoing).
(a) 01 set of 900 Amps TPN aluminium bus bar of suitable length and of crossection as per design with colour codding. Bus bars shall be designed to with stand a fault level of 36 KA at 415 volts. (b) MCCB 630 Amp 4 pole 36 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Makes: Legrand(DPX^3) Cat No.422009 or equivalent to Schneider/Siemens - 01 No as incoming (c) MCCB 4 pole 400 Amp, 36 KA with thermal and magnetic release with Ics=100% Icu conferming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and overload protection:12 IN Make:- Legrand Cat No. 422007 or equivalent make of Schneider / SIEMENS - 01 Nos as outgoing (d) MCCB 4 pole 320 Amp, 36 KA with thermal and magnetic release with Ics=100% Icu conferming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and overload protection:12 IN Make:- Legrand Cat No. 422006 or equivalent make of Schneider / SIEMENS - 02 Nos as outgoing
Dismentiling, taking down unserviceable feeder pillar and Supply, installation, testing & commissioning in renewal of totally enclosed feeder pillar outdoor type fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powder coated double door type (independent cabin including locking arrangement for each MCCBs, bus bar chamber enclosed complete suitable for operating on 415 Volt 50 Hz AC supply internally wired with copper conductor having legs 90 cms made out of 50x50x6 mm angle iron grouted on brick masonary platform upto 45 cms. Brick masonary platform should be 60 cms above the Ground Level. Comprising the following:- .Note:- (i) The panel shall be front operated with cable entry from the bottom with cable glands. Earth bus shall be part of the main feeder pillar. (ii) Fabrication of feeder pillar box to be approved by CPRI width of the panel not less than 75 cms. (iii) Cost for construction of platform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC copping 1:2:4 (40 mm thick stone aggerate), deemed to be included in the item rate. No Extra payment will be made. (iv) MCCB's should be connected with extensions terminals at both side (incoming and outgoing).
Dismentiling, taking down unserviceable feeder pillar and Supply, installation, testing & commissioning in renewal of totally enclosed feeder pillar outdoor type fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powder coated double door type (independent cabin including locking arrangement for each MCCBs, bus bar chamber enclosed complete suitable for operating on 415 Volt 50 Hz AC supply internally wired with copper conductor having legs 90 cms made out of 50x50x6 mm angle iron grouted on brick masonary platform upto 45 cms. Brick masonary platform should be 60 cms above the Ground Level. Comprising the following:- .Note:- (i) The panel shall be front operated with cable entry from the bottom with cable glands. Earth bus shall be part of the main feeder pillar. (ii) Fabrication of feeder pillar box to be approved by CPRI width of the panel not less than 75 cms. (iii) Cost for construction of platform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC copping 1:2:4 (40 mm thick stone aggerate), deemed to be included in the item rate. No Extra payment will be made. (iv) MCCB's should be connected with extensions terminals at both side (incoming and outgoing).
(a) 01 set of 1200 Amps TPN aluminium bus bar of suitable length and of crossection as per design with colour codding. Bus bars shall be designed to with stand a fault level of 36 KA at 415 volts. (b) ACB 800A, draw out type, shall confirm to IEC 60947 /IS 13947 (Part 1 & 2). The minimum breaking capacity should be 50KA. The service short circuit breaking capacity (Ics) should be equal to ultimate breaking capacity (Icu) and short time with stand capacity (Icw) with ICS =Icu=Icw. The Icw value is for 1sec. The ACB shall have microprocessor based LSIG protection units with flexible and adjustable current - time protection settings for overload, short circuit, instantaneous short circuit and Earth Fault Protections. ACB should be suitable for a 3 phase service voltage, up to 690V for 50 Hz AC supply and shall have an insulation voltage of 1000V. All the protection units should have built in Dedicated inbuilt LEDs for fault indication for overload, short circuit and Earth Fault. Makes : Legrand/schneider/Siemens.
Disconnecting the electrical connections from feeder pillar/LT panel, taking down the unserviceable feeder pillar/LT panel from plinth and transportation to workshop for repair. After repair the same will be transported at site & install the original position including making all electrical connections with appropriate size of new lugs complete all as specified and directed.
Taking out the broken hinges/unserviceable hinges & door handles from feeder pillar/LT Panel and replace with cold rolled MS hinges of appropriate size through spot welding & Mild steel sliding door bolt including making necessary adjustment for free and smooth movement of panel and 2 coat of powder coated spray painting inside & outside the panel complete all as specified and directed.
Taking out the burnt /unserviceable bus bar of any capacity and length, copper cable inter connections including insulators from feeder pillar/LT Panel & replace with appropriate size and capacity of aluminium bus bar & insulators with new S/S nut bolts and washers including appropriate size of copper cable inter connections complete all as specified and directed.
Taking out the damaged/deshaped part/portion of the LT Panel/feeder pillar and repalce with new portion of LT panel/feeder pillar made out of CRCA sheet 3.15mm thick including making necessary adjustment and allignment to make the existing feeder pillar/LT Panel to its required shape and size with 2 coats of powder coated spray painting inside and outside the complete panel all as specified and directed.
Supply and fixing in replacement of unsv MCCB 250 Amp 4 pole 36 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Makes: Legrand(DPX^3) Cat No.420249 or equivalent to Schneider/Siemens
Supply and fixing in replacement of unsv MCCB 4 pole 320 Amp, 36 KA and thermal and magnetic releases with Ics=100%Icu. conferming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection.Make: LEGRAND Model No DPX>3 Cat Part No 422006 or equivalent to Schneider/Siemens
Supply and fixing in replacement of unsv MCCB 200 Amp 4 pole 25 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Makes: Legrand(DPX^3) Cat No.420218 or equivalent to Schneider/Siemens
Supply and fixing in replacement of unsv MCCB 160 Amp 4 pole 25 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Makes: Legrand(DPX^3) Cat No.420057 or equivalent to Schneider/Siemens.
Supply and fixing in replacement of unsv MCCB 125 Amp 4 pole 16 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Makes: Legrand(DPX^3) Cat No.420016 or equivalent to Schneider/Siemens
Supply and fixing in replacement of unsv MCCB 100 Amp 4 pole 16 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Makes: Legrand(DPX^3) Cat No.420015 or equivalent to Schneider/Siemens
Supply and fixing in replacement of unsv MCCB 63 Amp 4 pole 16 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Makes: Legrand(DPX^3) Cat No. 420013 or equivalent to Schneider/Siemens
Supply and fixing in replacement of Contactor MO C3. Make L&T/Seimens/Schneider
Supply and fixing in replacement of Contactor MO C5. Make L&T/Seimens/Schneider
Supply and fixing in replacement of Contactor MO C10. Make L&T/Seimens/Schneider
Supply and fixing in replacement of Contactor MO C15. Make L&T/Seimens/Schneider
Supply and fixing in replacement of Contactor MO C20. Make L&T/Seimens/Schneider
Supply and fixing in replacement of Digital Panel meter Current sec 0.05-5A/5A/1A. Frequency range 40-70 hzs 12 stage . Make L&T (etaSMART) Cat Part No CS90902OOOO and equivalent of Seimens/Schneider
Supply and fixing in replacement of Digital Panel meter Current sec 0.05-5A/5A/1A. Frequency range 40-70 hzs 12 stage . Make L&T (etaSMART) Cat Part No CS90902OOOO and equivalent of Seimens/Schneider
Supply and fixing in replacement of MCB TP 6A C Curve in existing panels all as specified and directed. Make : L&T/Seimens/Schneider
Supply and fixing in replacement of MCB TP 10A C Curve in existing panels all as specified and directed. Make : L&T/Seimens/Schneider
Supply and fixing in replacement of MCB TP 20AC Curve in existing panels all as specified and directed. Make : L&T/Seimens/Schneider
Supply and fixing in replacement of MCB TP 40A C Curve in existing panels all as specified and directed. Make : L&T/Seimens/Schneider
Supply and fixing in replacement of APP Technology 1 Kvar Standard duty Capacitor in existing panels all as specified and directed. Make : L&T/Seimens/Schneider
Supply and fixing in replacement of APP Technology 2 Kvar Standard duty Capacitor in existing panels all as specified and directed. Make : L&T/Seimens/Schneider
Supply and fixing in replacement of APP Technology 5 Kvar Standard duty Capacitor in existing panels all as specified and directed. Make : L&T/Seimens/Schneider
Supply and fixing in replacement of APP Technology 10 Kvar Standard duty Capacitor in existing panels all as specified and directed. Make : L&T/Seimens/Schneider
Supply & Fix HT 11 KV out door type gang operated air break switch suitable for horizontal or vertical mounting rotating type triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level for current rating upto 200 Amp with drop out fuse having 15 insulators all as specified & directed.
Supply and fixing ACSR conductor of any size and type from over head HT/LT poles including binding at site to insulator with suitable size of binding wire etc including taking down existing worn out old broken ACSR conductor of any size and type and length at any position from LT poles.
M&L for replacement of Stay assembly with accessories and GI stay rod 16 mm dia.
Supply and fix for Galvanised steel wire of size 4mm dia for LT OH line and as directed by Engineer-in-charge.
M&L in replacement of Pin type porcelain vitreous white brown or green insulator including one galvanized mild steel spindle, two galvanized iron, washers and one galvanized iron nut, 150 mm height, 150 mm dia for 11000 volt grade all as specified.
Supply & fix in replacement of Shackle type, porcelain, vitreous, white, brown or green insulators on LT pole including opening of binding wire carefully and rebinding with new binding wire for working pressure 1100 volts grade, 90 mm dia 75 mm height including galvanized mild steel straps of 30 x 3 mm size, 12 mm dia insulator bolts, washers and nuts complete all as specified.
Material & Labour for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm all as specified.
Supply, installation, testing and commissioning outdoor type LT Feeder Pillar, factory made, dust and vermin proof fabricated out of 3.15 mm thick MS sheet complete with openable shutter in front and rear having proper locking arrangement, duly powder coated and including 600 Amps, 4 pole Aluminium busbar mounted on insulator, suitable for 3 phase, 415 volts, 50 Hz AC supply including control wiring to panel with suitable size of PVC insulated and sheathed copper cable, and connecting outgoing MCB / MCCB with outgoing LT cables etc and duly mounted on angle iron frame 50x50x6 mm including necessary PCC foundation work in all respect and comprising of following: -
Supply, installation, testing and commissioning outdoor type LT Feeder Pillar, factory made, dust and vermin proof fabricated out of 3.15 mm thick MS sheet complete with openable shutter in front and rear having proper locking arrangement, duly powder coated and including 400 Amps, 4 pole Aluminium busbar mounted on insulator, suitable for 3 phase, 415 volts, 50 Hz AC supply including control wiring to panel with suitable size of PVC insulated and sheathed copper cable, and connecting outgoing MCB / MCCB with outgoing LT cables etc and duly mounted on angle iron frame 50x50x6 mm including necessary PCC foundation work in all respect and comprising of following: -
Supply, installation, testing and commissioning outdoor type LT Feeder Pillar, factory made, dust and vermin proof fabricated out of 3.15 mm thick MS sheet complete with openable shutter in front and rear having proper locking arrangement, duly powder coated and including 400 Amps, 4 pole Aluminium busbar mounted on insulator, suitable for 3 phase, 415 volts, 50 Hz AC supply including control wiring to panel with suitable size of PVC insulated and sheathed copper cable, and connecting outgoing MCB / MCCB with outgoing LT cables etc and duly mounted on angle iron frame 50x50x6 mm including necessary PCC foundation work in all respect and comprising of following: -
Supply, installation, testing and commissioning outdoor type LT Feeder Pillar, factory made, dust and vermin proof fabricated out of 3.15 mm thick MS sheet complete with openable shutter in front and rear having proper locking arrangement, duly powder coated and including 400 Amps, 4 pole Aluminium busbar mounted on insulator, suitable for 3 phase, 415 volts, 50 Hz AC supply including control wiring to panel with suitable size of PVC insulated and sheathed copper cable, and connecting outgoing MCB / MCCB with outgoing LT cables etc and duly mounted on angle iron frame 50x50x6 mm including necessary PCC foundation work in all respect and comprising of following: -
Supply, installation, testing and commissioning outdoor type LT Feeder Pillar, factory made, dust and vermin proof fabricated out of 3.15 mm thick MS sheet complete with openable shutter in front and rear having proper locking arrangement, duly powder coated and including 600 Amps, 4 pole Aluminium busbar mounted on insulator, suitable for 3 phase, 415 volts, 50 Hz AC supply including control wiring to panel with suitable size of PVC insulated and sheathed copper cable, and connecting outgoing MCB / MCCB with outgoing LT cables etc and duly mounted on angle iron frame 50x50x6 mm including necessary PCC foundation work in all respect and comprising of following: -
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. Earth pit not less than 2.25mtr depth and top edge of the earth plate not less than 1.5mtr below normal ground level connected to galvanised iron strip 32 X 6 mm by means of nuts,bolts & washer etc. Earth strip connected upto main earth point/DBs alongwith 40 mm dia earth protection pipe from top edge of the earth plate to main earth point to be connected and 20mm dia watering pipe light grade with funnel and provn of PCC using cement concrete (1:2:4) mix type B1 ( using 20 mm graded stone agregate) and RCC pit cover 50 mm thick precost RCC (1:2:4) mix type B1 duly reinforced with 8 mm dia of ms bar @ 15 mm CIC with both way lifting arrangement complete including all necessary excavation & earth work all as specified and directed
M&L for making desert cooler stand by cutting ,welding or moulding of angle iron of size 40X40X4 mm by fixing with adjoining wall or window all as specified & directed.
Supply & laying in replacement GI pipe light grade 40mm bore under road, path or along poles as cable protection. Make Tata/Jindal/Prakash suriya.
Supply & laying GI pipe light grade 50mm bore under road, path or along poles as cable protection. Make Tata/Jindal/Prakash suriya.
Supply & laying GI pipe light grade 80mm bore under road, path or along poles as cable protection. Make Tata/Jindal/Prakash suriya.
Supply & laying in replacement GI pipe light grade 80mm bore under road, path or along poles as cable protection. Make Tata/Jindal/Prakash suriya.
Supply & laying in replacement GI pipe light grade 100mm bore under road, path or along poles as cable protection. Make Tata/Jindal/Prakash suriya.
Supplying laying and testing ductile iron pipe 150mm bore spigot class K-9 as per IS-8329 with inside cement lined complete with push on rubber joints including taking out old unserviceable all as specified and directed by Engr-in-Charge. Make : Jindal/ Electro steel costing Ltd/ Kesoram. (Earth work for route change/joints shall be measured and paid for separately).
Supply and fixing cast iron body sluice valve heavy duty class PN 1.6 flanged ends any pattern with head wheel & brass spindle ISI marked conforming to IS-14846 of 2000 for 150mm bore pipe with jointing material ,flanged joint,rubber gasket 6mm thick, nuts & bolts, washer 10mm thick, including dismantling old one, all complete all as specified and directed. Make:- Kirloskar/Leader/L&T
Cutting of existing cast iron pipe line of 150 mm bore in position for inserting CI Special such as tees,bend,coller,tail piece etc for fixing of sluice valves/for branch connection etc. Note:- Exc & earth work,CI Special & sluice valves of size & lead joint shall be measured and paid separately under respective item of shedule 'A'.
Material and labour for run lead joint including all jointing material such as lead, spun yarn etc for 150mm bore cast iron spigot & socketed pipe & fittings.
Supply and fixing upto 150 mm dia bore DI fittings such as bends, tees collars tail pieces conforming to IS-9523 complete all as specified and directed. Make : Jindal/ Electro steel casting Ltd/ Kesoram.
M & L of Valve pit of size 120 cm x120 cmx 90 cm (internal dimensions), Stone masonry struction,including all necessary excavation and earth work in hard/ dense soil,returning,filling,in disposal of surplus soil to a distance not exceeding 50 m and depositing where directed , PCC in foundation of the mix (1:4:8) Type D-2 (using 40 mm graded crushed stone aggregate),brick masonry in cement mortar (1:4) rendering,12 mm thick in cement mortar (1:4) internally,finished even and fair and pointing flush externally as the work proceeds in the same mortar. Mild steel angle iron 40x40x6mm frame,MS sheet cover 3.15mm thick with handle and locking arrangment ,painting ,all the exposed MS work with two coats of synthetic enamel paint , a coats of red oxide primer and painting all the MS embedded in PCC with two coats of black bituminous paint etc including opening rod having lenth 1.5 mtr . complete all as specified
M & L for welding the existing water supply Header any size by using electric welding machine & welding electrode for making new branch connectios as directed by Engr-in-Charge.
Fixing only storage type geyser of capacity 25 ltr 220 volt single phase AC supply, copper tank in metallic body five star rated energy efficient including grouting nos of bolts/studs in wall and making good all as specified and directed by Engr-in-charge. Make-Havells as per Cat part No GHWASESWH025 or equivalents in crompton/Bajaj.
Supply and fixing storage type geyser of capacity 25 ltr 220 volt single phase AC supply, copper tank in metallic body five star rated energy efficient including grouting nos of bolts/studs in wall and making good all as specified and directed by Engr-in-charge. Make-Havells as per Cat part No GHWASESWH025 or equivalents in crompton/Bajaj.
Supply and Fixing steel water tubing of size 15 mm dia, medium grade,galvanised iron with all Fittings such as sockets,bends,unions,tee, short pieces,nipples,brass nuts and diminishing pieces complete laid in floors ,fixed to walls and ceilings complete all as specified and directed . Make: Prakash surya/Jindal/Tata.
S & F stop valve cast copper alloy with crutch or butter fly handle, screwed down both ends, screwed down for iron pipes or for brass ferrules and fixed of size 15 mm dia.
Supply & Fixing bib taps cast copper alloy 15 mm dia with butterfly handdle screwed down, screwed for iron or for brass ferrule complete all as specified.
Supply and fix single pole and neutral enclosure with a two pin and earth plug and socket complete one single pole MCB of 20 Amp complete all as specified and directed.
S & F PVC connection heavy duty with PTMT nut & washers for both ends of size 15 mm dia and 600 mm long complete all as specified.
M&L for Cutting/screwing existing steel water tubing for additions or alterations complete all as specified.
S&F socket residual current device (SRCD) DBOXx in steel enclosure with MCB SPN 16Amp and plug top 15/16 Amp Make : Havells Cat no. DHDDCDP025201603 or equivalent in C&S complete all as specified.
SATISH AND CO
power control system
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .