Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹7.2 L+₹1.0 L (16.9%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹7.5 L+₹1.3 L (20.6%)Rejected-Finance | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹15,454
Closing Date
15 Dec 2022, 3:00 pmClosed
MD,WBMSCL
HQ,WBMSCL
Renovation work for smart look of building external area at Falakata Super Speciality Hospital, Dist. Alipuduar -Electrical Installation work
2022_WBMSC_429134_8
WBMSCL/NIT-544/2022 Dated 30/11/2022
Open Tender
Electrical Work/ Equipment
Item Rate
30 days
Falakata Super Speciality
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹15,454
25 Jan 2023
2 Dec 2022
16 Dec 2022
2 Dec 2022
15 Dec 2022
9 Dec 2022
Amount
Supply, installation, testing & commissioning of fabricated Chanellium Letter (Sign Board) fo hight 2ft of following specification: (FALAKATA SUPER SPECIALITY HOSPITAL=24 X 31= 744 Inch) (Matter & Language will be approved by the appropriate authority)
a) Each side of the letter would be made of 50mm breadth, 1.2mm thick Alluminium Sheet with the help of suitable cutting & bending machine.
b) Back side of the letter would be made from 2mm thick Alluminium Sheet by cutting according to appropriate letter block with the help of suitable cutting & bending machine.
c) Front side of the letter would be made of 4mm thick Mitshubishi or equivalent make imported Acrylic Sheet by cutting according to appropriate letter block with the help of suitable cutting & bending machine. The Color of the letter will be approved by the appropriate authorirty of the Hospital/Medical College.
d) For glowing each letter, Samsung or equivalent make (0.97 - 1.02)W LED module would be used. (Make will be approved by the EIC)
e) To provide power for LED module, suitable SMPS unit of IP-67 would be used in respect of load of each letter. And the power supply unit would be fixed in suitable MS or equivalent box of IP-65 on parapet wal or iron structure with appopriate clamp. (Make will be approved by the EIC)
f) All side of the letters (only side & back wall) would be painted with synthetic enamelled/PU paint. (Color & Make will be approved by the EIC)
g) The inter-connection of SMPS unit & LED mobule circuit of each letter would be made with FR PVC insulated sheathed copper wire. And the letter complete in all respect would be fixed on pre-errected MS structure by suitable SS nut-bolt & washer - as per direction of EIC.
(The above rate is considered including loading, unloading & transportation & all other charges)
Febrication & errection of suitable Iron Structure would be made with 75*40*5 mm 'C' Iron Channel as vertical support on floor/roof, 50*50*5 mm Iron Angle for continuous horizontal frame supprot for top & bottom of each letter & cross angle support to structure, 50*5mm Iron Flat for continuous horizontal frame supprot for middle of each letter. A Sole plate of size 300x300x5mm would be welded at the bottom of each vertical support and suitable sole plate in case of cross support. The complete structure would be painted with two coats Red-Oxide Primmer & two coats Synthetic Enamelled paint. The structure would be errected on roof supported to parapet wall. (The work would be executed as per direction of EIC.
Ordinary Cement Concrete 1:1.5:3 with graded stone chips (20mm nominal size) excluding shuttering and reinforcement if any at roof of the G+4 building as per relevant IS Code (PWD Building SOR Page: 25 Item: 6)
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (at the roof of the G+4 building) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary. (With 1:6 cement mortar, 20 mm thick plaster) [including cost of chipping over concrete surface] (at the roof of the G+4 building) (PWD Building SOR Page: 189 Item: 1/ i(b))
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m. (at the roof of the G+4 building) (PWD Building SOR Page: 192 Item: 15)
Supply & fixing of 1.5ftX1.5ft Acrylic Letter (07 nos.) on existing ACP/Acrylic board.
Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
Supply of 4 Sq mm., 3 Core, XLPE armoured copper cable.
Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
S & F compression type brass cable gland complete with brass gland, brass ring & rubber ring for dust & moisture proof entry of 3C 4sqmm XLPE/PVC armoured cable. [PWD/GS Page No.: F-4 Item No.: 7/c]
Finishing the end of the 3C 4sqmm XLPE/PVC armoured cableas by crimping method incl. S&F solderless socket (Dowels make), tapes, anticorrosive paste & joiting materials. [PWD/GS Page No.: F-5 Item No.: 8/b]
S&F medium gauge 32mm dia GI Pipe (ISI-Medium) Protection with necessary fittings and jointing metarials as required as per GS. [PWD/GS Page: F-6 Item: 11]
Supply & deliver of Bollard Light. robustly designed IP65/ IK10 Bollard and is easy to install with base plate and fixing bolt. Colour: Warm White Make: Havellsl- CONEBLS8W LED830 ESYMTOPC or equivalent of Philips or Crompton or Wipro or Panasonic- as approved by the EIC)
Fixing of 10 watt Led BOLARD light set with necessary connection.
Excavation of soil for installation of Muffing and filling & ramming.
Erection of foundation for Bollard Light fitting- by cement concrete (1:1.5:3) with stone chips- the base foundation of size will be 450X450X250mm and 1ft dia & 1ft depth of round foundation on base including S/F of suitable foundation bolt, suttering & necessary UPC pipe for cable connection. The 150mm of the total foundation will be above the ground.
Supply & delivery of flood light (Make: Havells- GETAALBA FLOODLIGHT 70W or equivalent Crompton of Philips or Wipro or Panasonic- as approved by the EIC)
Fixing only outdoor/Flood light type fluorescent light fitting complete with all accessories to be fixed/projected from the wall of the building incl. making holes to building, S&F 40 mm dia GI pipe (ISI-Medium) 1.50 mts. average length, with GI socket at one end and thread at the other end & suitable bend to house the fitting & making necy. connections with S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall and painting (PWE SOR Page: C3 item: 10)
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint
M.C. ENTERPRISE
SANKAR GHOSH
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .