| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹95.7 LAccepted-AOC | L1 | Accepted-AOC Being lowest and reasonable tender | |
| 2 | L2₹1.1 Cr+₹8.1 L (8.17%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | L2 | Rejected-Finance Being second lowest bidder | |
| 3 | L3₹1.1 Cr+₹8.8 L (8.86%)Rejected-Finance 126 NARANG COLONY JANAKPURI NEW DELHI 110058 | WEST | DELHI | 110058 | L3 | Rejected-Finance Being third lowest bidder | |
| 4 | L4₹1.1 Cr+₹10.7 L (10.9%)Rejected-Finance | L4 | Rejected-Finance Being fourth lowest bidder | |
| 5 | L5₹1.2 Cr+₹19.9 L (20.1%)Rejected-Finance | L5 | Rejected-Finance Being fifth lowest bidder |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
22 Sept 2023, 6:00 pmClosed
CWE AF PALAM
CWE(AF) PALAM DELHI CANTT-10
SPECIAL REPAIR TO AIRMEN BILLETS OF HQ WAC AT SUBROTO PARK(PHASE-I) UNDER GE (AF) SUBROTO PARK, DELHI CANTT-10
2023_MES_613695_1
CWE/PM/SP-22/2023-24
Open Tender
Civil Works
Item Rate
240 days
GE AF SUBROTO PARK
As per tender documents
10 documents required · 10 mandatory
₹1,000
GE AF SUBROTO PARK
₹2.2 L
21 Nov 2023
14 Aug 2023
25 Sept 2023
14 Aug 2023
22 Sept 2023
8 Sept 2023
Amount
BUILDING WORKS
Dismantling of any type of aluminium partition made of Aluminium and plyboard complete all as specified and directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L 25 mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in sub base of floor complete all as specified and as directed.
M&L non skid ceramic coloured tiles 10 mm thick (square/rectangular) area of each tiles exc 0.18 sqm but n. exc 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match over 15 mm thick screed bed or bedding layer in CM (1:4) complete all as specified and directed.
M&L non skid ceramic coloured printed tiles 7 to 8 mm thick (square/rectangular) area of each tiles exc 0.11 sqm but n. exc 0.18 sqm, in floors or dado etc set and jointed in neat cement slurry and pointed in coloured cement to match over 15 mm thick screed bed or bedding layer in CM (1:4) complete all as specified and directed.
M&L Glazed coloured ceramic tiles in vertical surface/ dado 450 mm x 300 mm x 7 to 8 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed.
Dismantling of Stone slabs laid, bedded and pointed in any mortar complete all as specified and directed
M&L for screed bed or bedding layer of mortar 20 mm thick in CM 1:4 for laying floor finishes complete all as specified and directed.
M & L for machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to achieve mirror polish complete all as specified and directed. (Note : kota will be fixed on stair case in one piece)
M/L for machine cut kota stone slab 25mm thick as in riser of steps, skirtings, dados etc over 10 mm thick cement screed in CM (1:6) jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to achieve mirror polish complete all as specified and directed.
S & F in repair 0.5 mm thick aluminium sheet be fixed on crumple joint including paint and nail complete all as specified and directed
Taking down door chowkhats or frames with shutters, any type (without taking off shutters from the frame) area exceeding 1.5 sqm but n.exc 4.0 sqm complete all as specified and directed.
S&F 35mm thick flush shutters, solid core construction, with block board core & plywood face panels, commercial type on both sides complete all as specified and as directed.
S&F 2nd class Hardwood glazed and skelton 35mm thick shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars) , edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass,Gauze etc complete all as specified and as directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with SS wire staples complete all as specified and as directed.
S&F Butt hinges,medium weight, cold rolled, mild steel of size 100mm complete all as specified and as directed.
S&F Aluminium alloy, anodised, sliding door bolt 300mm long with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded sections & fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed.
S&F 200 mm length aluminium anodized, barrel tower bolts of extruded section complete all as specified and as directed.
S&F 150 mm size aluminium handle, cast type anodized complete all as specified and as directed.
M&L for PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in hold fasts including necessary use and waste of form work complete all as specified and as directed.
S&F mild steel work as in holdfast made out of flat iron 25mmx5mm including necessary welding or fixing nuts and bolts complete all as specified and as directed.
S &F Rolled mild steel sections conforming to Gde Fe-410-0 grade A as in framing for cladding, glazing and the like including door frames/ chowkhats, fixed with angle cleats and connecting plates, etc complete all as specified and as directed.
S & F in repair 150mm mild steel, ordinary rat tail rod pattern spring including roller and roller plate complete all as specified and as directed.
S&F in repairs Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick (TCT) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal/wooden frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and as directed.
S &F 04 mm thick figured sheet glass, ordinary quality and glazing with oil putty or wooden beads in square area not exc. 0.5 Sqm in each pane complete all as specified and as directed.
M&L applying two coats of synthetic enamel paint on new steel surfaces of any description over 10 cm width or girth over a coat of red oxide primer including preparation of steel surfaces complete all as specified and as directed.
M & L applying two coats of synthetic enamel paint on new wooden surfaces of any description over 10 cm width or girth over a coat of pink primer including preparation of surfaces complete all as specified and as directed.
S&F in repair to rotational moulded vertical water storage tanks triple layer ( White colour) with closed tops ( cylindrical ) hoisted and fixed in position 1000 litre capacity including disconnecting and refixing the existing GI fitting and pipe complete all as specified and directed.
S&F in repairs of ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed suitable for iron pipe 40mm bore having weight not less than 210 gms complete all as specified and as directed.
Supply and fixing in repair windows/ ventilators fabricated from 0.60 mm thick roll formed section made of galvanised steel powder coated (Base steel as per IS-513"D" quality) galvanised as per IS-277 with ZINC of 120GM/SQM . Windows /ventilators having frame suitable for dual shutter i.e. inner and outer shutter with grill, glazed and wire mess shutter and all fitting, fixtures accessories including 6mmx12mm flat iron with 10mm square bar M.S. grills complete as specified and shown in drawing No CEAF/STD-191/2014, sheet 1/2 & 2/2 dated 11.12.14(4000 series) NOTE: (i) Glazed shutter with 4.00 mm thick glass, mesh shutter with 32 gauge stainless mesh and MS grill as per srl no 10,11 and 13 of notes of above mentioned drawing is deemed to be inclusive in the rate quoted for unit (ii) Glass, stainless steel mesh will be fixed to window by authorised rep of manufacturer of window only. Quoted rate shall include cost towards taking down of windows and making good the surface complete all as specified and as directed.
S & F Aluminium door single leaf with anodized aluminium frame of section 62.5 x 37 x 2.5 mm thick, shutter with bottom & middle rail of section 112.50 x 37 x 2.5 mm thick and styles & top rail of section 83 x 37 x 2.5 mm thick with centrally locking arrangement with lock make of ‘GODREJ’ or ‘LINK’ 7 lever and self closing device with rebate including jointing cleats, fixing of builders hardware fittings, necessary numbers of floor spring and glazing with 5.5 mm thick ordinary plain glass including necessary fittings, fixtures & aluminium snap beads including taking down any type of door complete all as specified and directed.
S & F aluminum window with aluminum anodized frame of aluminum section 62.5 x 37 x 2.5 mm thick with shutters having styles & rails of aluminum section 44.45 x 44.45 x 2.5 mm thick including jointing cleats, glazing clips, rubber packing, aluminum snap beading, screws anodized aluminum fittings such as hinges, tower bolts, handles etc including 5.5 mm thick ordinary plain glass complete. Including providing and fixing aluminum chequered grill of anodized section of mesh 100x100mm of 08 mm dia of bar fixed to frame with 20x20 mm aluminum flat with stainless steel wire mesh fixed with screw including taking down old one complete all as specified and as directed.
S & F in repair aluminum chequered grill of anodized section of mesh 100x100mm of 08 mm dia of bar fixed to frame with 20x20 mm aluminum flat section with stainless steel wire mesh fixed with screw complete all as specified and as directed.
M & L for complete removal of existing any type of existing roof treatment including bedding layer of concrete/mud any thickness in cement mortar and disposed from MOD land complete all as specified and as directed.
M & L for cement concrete 1 : 2 : 4 type B-0 (using 12.5 mm graded stone aggregate) laid as in padding 25mm thick average over roof slabs for providing proper slope including finishing surface even and smooth without using extra cement with 3% water proofing compound by weight of cement complete all as specified and directed. Note : WPC will be measured and paid separately.
M&L for five layer prefabricated atactic polypropylene polymer (APP) modified 3 mm thick membrane ( weight not less 3 kg/sqm) reinforced with 160 gms polyester non-woven fabric with scratched tool before finishing roof surface. When the concrete surface is still green, the roof surface shall be thoroughly wire brushed washed dried up and cleaned of all foreign matter and dust prior to the application of primer on the dried surface one coat of approved bituminous primer, having density in the range of 0.87 to 0.89 kg/ litre at 25 degree and viscosity of 70 to 160 CPS manufactured by the same manufacturer @ 0.40 litres/sqm shall be applied. APP membrane shall be laid on primed surface torch application method after allowing 24 hours of primer to dry. Laying of APP membrane shall be commenced at the lowest level and worked upto the crest. APP membrane will normally be laid in length at right angle to the direction of slope. The overlaps shall be of minimum 100 mm on longitudinal direction and 150mm on the transverse direction. All overlaps shall be bonded with bitumen primer and levelled by the heating the overlaps with butane tourch. This treatment shall be done by the approved authorised applicator. Guarantee of treatment shall be for 10 years. Thereafter APP membrane shall be painting with two coat of water proofing paint with aluminium finish. (ii) Independent testing of membrane for the approval technical parameters specified hereinafter shall be carried out from the approved laboratories like National test house any other Govt approved laboratory having facilities for the testing of membrane.
Supply only Liquid water proofing compound complete all as specified and as directed.
Material and labour for false ceilings using GI snap grid system with roll-formed out of hot dip galvanised steel caping (powder coated) main runner 38 x 24 mm , cross Tee 29 x 24 mm and wall angle 24 x 24 mm members suspended with 4mm dia GI wire, carry maximum load up to 8.10 Kg/Sqm with 4mm thick designer ceiling board , pre painted Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions size 595 x 595mmx 4mm thick any texture (Lake and Hill, oceanic cascade or Electra) as approved by GE all as per , Everest Ceiling grid system 'Regular T-2430' or its equivalent make at any height including dismantling complete all as specified and as directed.
Taking down cement plaster etc on brick wall or stone walls etc. including raking out joints, hacking for key, scrubbing down with water, etc. and disposed off unserviceable materials to outside of MOD land complete all as specified and as directed.
M&L 12 mm thick cement mortar 1:6, on uneven surface of brick work or concrete surfaces on wall surface even and smooth without using any extra cement complete all as specified and as directed.
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:3) as in ceiling, complete all as specified and as directed
M&L 15 mm thick cement mortar 1:4 on other than fair faces of brick work or concrete surfaces on wall surface even & fair complete all as specified and as directed.
M & L Preparation of newly plastered or unplastered surface and applying two coats of distemper oil emulsion over a one coat of primer on walls complete all as specified and as directed.
M & L preparation of newly plastered surface and applying three coats of white wash on ceilings complete all as specified and as directed.
M&L for preparing new surface and applying exterior paint (weather coat, apex ultima or equivalent) of required shade,Two coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm, complete all as specified and as directed. make : Asian/Berger/shalimar
M&L for complete removal of existing treatment of old decorated surfaces of walls by steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and washing, rubbing down and stopping of existing surface and making the surface even and smooth and apply two coats of white wash on ceilings complete all as specified and as directed.
M&L for complete removal of existing treatment of old decorated surfaces of walls by steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and washing, rubbing down and stoping of existing surface and making the surface even and smooth and apply Two coats of distemper oil emulsion on walls complete all as specified and as directed.
M&L for complete removal of existing treatment mechanically or manually on old surface of wall and preparing surface and applying two or more coats 100 % acrylic based exterior emulsion paint having VOC less than 50 gm/ltr and UV resistance as per IS 15489:2004(latest revision), Alkali & fungal resistance, dirt resistance 1st quality exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 ltr /10 sqm over and including priming coat of exterior grade primer applied @ 0.90 litre/10 Sqm including change of existing colour if required complete all as specified and as directed (Make ASIAN(Ultima Asian)/BERGER (All guard) or equivalent in shalimar paints. Note : Rate is inclusive for scaffolding or required necessary arrangement for multistorey building
M&L for dismantling loose concrete cover of RCC slab, ceiling , columns, beams,chajja, balconies, staircase and as directed,roughening and cleaning concrete surfaces with steel wire brushes, removing of rust from existing steel surfaces with rust removers of SIKA restoff 100 or equivalent in Fosroc /Bostik, applied two coats @0.15kg/Sqm per coat of steel surface and cleaning all rust with steel wire brush and washed with water and allowed to dry incl S&F welded fabric GI wire mesh or wire , size not less than 75 x 75 mm and 3 mm dia as reinforcement to concrete. After placing the additional reinforcement, all concrete surfaces shall be throughly scurbbed with brushes, washed with water and allowed to dry to this surface , apply chemical polycrete admixture at the rate not less than 2% by weight of cement and providing minimum 30 mm thick (average thickness) guniting mix (using 1 part of ordinary Portland cement 53 grade and 2 parts of ghaggar sand mixed with adhesive/admixture at the rate as directed) with a pressure of 2.2 to 2.5 kg per sqm by guniting machine and surfaces finished even and fair including necessary padding, shuttering form work etc and finally applying 5 mm thick cement plaster in CM 1:3 complete all as specified and directed.
Demolition of plain cement concrete in ground floors n. exc. 15 cm in thickness (below or above GL) unreinforced and removing debries outside of MOD land complete all as specified and directed.
M & L for 75 mm thick PCC (Plain Cement concrete) type D- 2, 1:4:8 (40mm graded aggregate) as in sub-base of floors and paving complete all as specified and directed.
M& L for 60 mm thick, M-35 grade machine pressed rubber form moulded precast interlocking concrete coloured (Red/yellow) paver block , in any shape and size with grey cement and pigment as approved confirming to IS 15658-2006(latest revised) complete all as specified and directed.
M & L for 75 mm thick PCC 1:3:6 type C2 as in Plinth Protection using 40 mm graded stone aggregate including making joints & filling with sand bitumen mastic complete all as specified and directed..
M&L cement concrete 1:2:4 type B-0(using 12.5 mm graded stone aggregate) as in roof kerbs or mud stops rounded or chamfered on edges complete all as specified and directed.
Demolition of cement concrete (reinforced) of any position not otherwise specially provided for and removing debries outside of MoD land complete all as specified and directed .
M & L Form work to chajja, fins, parapet wall & roof projection complete all as specified and directed .
M & L RCC 1:2:4 as in chajja, fins, parapet wall & roof projection complete all as specified and directed .
S & F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, beam chajja etc hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed .
S & F mild TMT steel bars 6 to 8 mm dia TMT bars cut to length , bent to shape required including cranking , hooking end and binding with and including mild steel wire (annealed ) not less than 0.9 mm dia complete all as specified and directed .
M & L as in repair for providing precast cement concrete type B0 1:2:4 (12.50 mm graded aggregate) set in cement mortar (1:4) ,louvers and jallies, 35.00 mm thick (measured solid), including all mouldings complete all as specified and directed .
S&F in repair curtain rods with mild steel conduit pipe 20 mm bore PVC coated of 1 mm thick including temples, brackets etc complete all as specified and directed.
S&F in repairs factory made 5mm thik PVC sheet of density 600kg/cum manufactured by an ISO-900-2008 certified company.Plain 5mm thick PVC sheet paneling for back side(wall side) and also manufacturer's test report and test certificate is mandatory with each and every supply of the material complete as per directions of Engineer-in-charge, manufacturers specifications and drawing.
INTERNAL ELECTRIFICATION
Taking down carefully copper/aluminium point wiring light ,fan, light fittings,socket or power complete, such as switches, ceiling roses, pendents, regulators, sockets etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc. complete all as specified and directed.
M&L for point wiring for one light point/fan point controlled by one SP switch with single core PVC insulated unsheathed 1100 volt grade cable with multi strand copper conductor of size 1.5 Sq mm FRLS (Nominal area) drawn through and including non metallic rigid PVC concealed conduit, medium grade, ISI marked not less than 20mm dia, concealed in wall, ceiling with GI saddles GI screws, rawl plugs (concealed conduit wiring) with all fittings including Tee, Junction boxes and provision of pressed steel terminal modular box powder coated of suitable size for mounting switch sockets and regulators and drawing continuous earth wire of PVC insulated unsheathed 1100 Volts grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) complete all as specified and directed. Note: Cost for cutting, chasing and making good to existing surfaces are deemed to be included in the Quoted Rate.
All as per item No-2.02 above but for one 3 pin socket out let, 6 Amps on same board with the cable 1.5 Sqmm size complete all as specified and directed.
All as per item No-2.02 above but for one 3 pin socket out let, 6 Amps on Independent board with the cable 1.5 Sqmm size complete all as specified and directed..
All as per item No 2.02 above but with 2.5 Sq mm cable for Independent bd one 3 pin 15 Amps socket outlet including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 V grade IS -694 FR LS cable for continuous earth wire required size complete all as specified and directed.
M&L for point wiring for light /fan / bell with FRLS cable 1.5 sqmm PVC insulated (red for phase and black for neutral) unsheathed, multi stranded copper conductor 1100 volt grade in existing concealed conduit and 1.50 sqmm green in colour PVC copper conductor cable for earth continuity connected to common earth dolly, by using existing steel terminal boxes of suitable size for mounting of switches, sockets, fan regulators etc and providing new covered 3 mm thick laminated. (Hylam) sheet top cover fastened with chromium plated screws for mounting fittings such as switches, sockets, fan regulators etc complete all as specified and directed for one light / fan / bell point controlled by one switch.
All as per item No 2.06 above but for multi 5 pin 5 amps socket outlet on same board complete all as specified and directed.
All as per item No 2.06 above but for multi 5 pin 5 amps socket outlet on independent board complete all as specified and directed
All as per item No 2.06 above but with 2.5 sqmm cable for 6 pin 15 amps multi pin socket outlet flush type on independent board complete all as specified and directed.
S&F switch piano 5 amps flush type single pole one way suitable for 240 volt AC complete all as specified and directed.
S&F socket outlet flush type 5 pin 6 amps suitable for 240 volt AC complete all as specified and directed.
S&F switch piano 16 amps flush type single pole one way suitable for 240 volt AC complete all as specified and directed.
S&F socket outlet 2 in 1, 5 pin 16 amps flush type suitable for 240 volt AC complete all as specified and directed.
Supply and fix electronic Fan Regulator rotary flush step type 120 watt, 240 volt complete all as specified and directed.
Supply and fixing of ceiling roses, surface bakelite 65x50mm 2 or 3 terminals , PVC/Polycarbonate, isolated body fixed on PVC round block complete all as specified and directed
Supply and fixing Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB complete all as specified and directed.
Supply and fixing wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver ,20 watt LED fitting, 4000K , 230 Volts, diffused optics ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed.
Supply and fixing wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver ,10 watt LED fitting with 100 lumen/watt, 6000K , 230 Volts, diffused optics ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed.
S &F LED wall mounted light with decorative wall bracket luminaire suitable for 11 W including providing flexible copper wire, twin core cable complete all as specified and directed.
Taking down including disconnecting the electric connection of ceiling fan and dismantling blades,greasing complete all as specified and directed
Hanging / fixing only ceiling fan received from item No 2.20 above and connecting up including fastner and provision of suitable size of copper cable from connector of fans to ceiling rose complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE, Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
Taking down including disconnecting the electric connection of exhaust fan and dismantling blades,greasing and painting the whole assembly complete all as specified and directed
M&L for repairing of exhaust fan 450 mm sweep (including change of bearings/windings with super enamelled copper wire of same size ) replacement of suitable capacity of condenser and testing complete all as specified and directed.
Fixing only Exhaust fan received from item No 2.24 above and connecting up including fastener and provision of suitable size of copper cable from connector of fans to ceiling rose complete all as specified and directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 450m sweep with, blades, and frame and louvers complete all as specified and directed.
Supply and fix wall fan, AC single Phase. 230V of size 400mm sweep complete all as specified and directed.
Taking down unserviceable submain wiring of aluminium of any size cable including batten/conduit complete etc and making good disturbed surfaces complete all as specified and directed.
M & L for submain wiring with four run of 10.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multi stranded copper conductor 1100 volts grade IS:694 marked and one run of 10.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuity conductor drawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all accessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified and directed. - 3 Runs of 10.0 Sqmm single core and one run of 6.0 sqmm single core cable.
M & L for submain wiring with three run of 6.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multi stranded copper conductor 1100 volts grade IS:694 marked and one run of 6.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuity conductor drawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all accessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified and directed - 2 Runs of 6.0 Sqmm single core and one run of 6.0 sqmm single core cable.
M & L for in replacement submain wiring with three run of 4.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multi stranded copper conductor 1100 volts grade IS:694 marked and one run of 4.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuity conductor drawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all accessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified and directed - 2 Runs of 4.0 Sqmm single core and one run of 4.0 sqmm single core cable
M & L for in replacement submain wiring with three run of 2.5 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multi stranded copper conductor 1100 volts grade IS:694 marked and one run of 2.5 sqmm PVC insulated but unsheathed FRLS cable for earth continuity conductor drawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all accessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified and directed - 2 Runs of 2.5 Sqmm single core and one run of 2.5 sqmm single core cable.
Taking down old unserviceable TPN DB of any size complete all as specified and directed..
Supply and fixing load line vertical distribution board 'A' frame made out of CRCA sheet,double door, surface mounting TPN 4 way 415 volts 200 Amps rated bus bar and stove enamels dust and vermin proof suitable for TP/FP 'A' frame MCCB of 100 Amps =01 No MCCB for outgoing complete all as specified and as directed. Note :- MCB and MCCB shall be measured and paid seperately.
Supply and fixing load line vertical distribution board 'A' frame made out of CRCA sheet,double door, surface mounting TPN 6 way 415 volts 200 Amps rated bus bar and stove enamels dust and vermin proof suitable for TP/FP 'A' frame MCCB of 125 Amps =01 No MCCB for outgoing complete all as specified and as directed. Note :- MCB and MCCB shall be measured and paid separately
Supply and fixing MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting TPN 12 way 415 volts double door type regal gray horizontal type complete all as specified and as directed Note :- MCB shall be measured and paid separately
Supply and fix in replacement of fixed thermal and fixed magnetic settings, 4 pole MCCB 100 Amps, 50 HZ, 415 volts with rupturing capacity 16 KA complete all as specified and directed.
Supply and fix in replacement of fixed thermal and fixed magnetic settings, 4 pole MCCB 125 Amps, 50 HZ, 415 volts with rupturing capacity 16 KA complete all as specified and directed.
Taking down old unserviceable MCB DB SPN of any size complete all as specified and directed..
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 8 way 230 volts double door type regal gray horizontal type complete all as specified and as directed. Note :- MCB shall be measured and paid separately.
Taking down unserviceable SP/SPN /TPN MCBs of any capacities from the MCCB DBs /MCB DBs after disconnecting the electric supply,complete all as specified and directed.
S&F MCB SP 6 to 32 Amps 10 KA, 240 volt 'C' Series complete all as specified and directed.
S&F MCB SP 40 Amps 10 KA, 240 volt 'C' Series complete all as specified and directed.
S&F MCB SPN 40 Amps 10 KA, 240 volt 50 Hz 'C' Series complete all as specified and directed.
S&F MCB TPN 63 Amps 10 KA, 415 volt 50 Hz 'C' Series complete all as specified and directed.
M&L for taking down existing geyser carefully of any capacity without damaging from bathroom and to be kept in safe custody until completion of finishing work and re-fixing the same after completion of work, complete all as specified and directed.
M&L for earthing complete with GI earth plate electrode 60cmx60cmx6.0mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to and including galvanized iron strip 4 mm dia as earth lead by means of GI bolts, nuts, check nuts and washers earth pit surrounded by picked layer of coal dust and 15 mm thick mixture in equal ratio of magnesium sulphate & copper sulphate in all around bottom and top and watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plate NO 5 of SSR Part I (1991) and connecting to earthing test point, including CI cover, frame and PCC (1:3:6) type C-2 using 20mm graded stone aggregate as in earthing pit with CI cover and framing including necessary earth work etc, complete all as specified and directed. Note :-(i) PCC chamber shall be constructed at least one meter away from building shall be provided in slanting manner. (ii) PCC pit cover shall be precast of RCC 1:2:4 type B-I 80 mm thick reinforced with XPM weighting not less than 4 Kg (sqm in lieu of CI)
M&L in replacement of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4 mm dia galvanized iron or steel wire complete all as specified and directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Supply and Fixing in repairs on PVC square Blocks, angle/batten holder D type with PVC insulated body complete all as specified and directed.
Supply and Fixing in repairs LED Bulb of capacity 9 watt complete all as specified and directed.
Commercial Traders
Atish Builders LLP
JYOTI ENTERPRISES
M/s. Kansal Construction Co.
imran construction company
A R construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .