Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.9 LAccepted-AOC 86 NAROTTAM KUNJ MADHU NAGAR AGRA UTTAR PRADESH 282001 | AGRA | UTTAR PRADESH | 282001 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹39.9 L+₹41,555.65 (1.05%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹39.9 L+₹45,256.90 (1.15%)Rejected-Finance 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹39.9 L+₹50,217.10 (1.27%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹40.5 L+₹1.0 L (2.55%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹48.9 L
EMD Value
₹97,800
Closing Date
28 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Maj Ashwin Awadh
Garrison Engineer West 62 Station Road Agra Cantt
SPECIAL REPAIR TO ARMY HOLIDAY HOME AT AGRA UNDER GE (W) AGRA
2023_MES_582629_2
8012/943/E8
Open Tender
Civil Works
Item Rate
180 days
Ge West Agra
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Ge West Agra
₹97,800
31 Mar 2023
20 Mar 2023
30 Mar 2023
20 Mar 2023
28 Mar 2023
20 Mar 2023
Amount
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and pre-cast concrete articles complete all as specified and directed by Engineer-in-Charge.
M&L for brick work with sub class ‘B’ bricks old size, straight or curved on plan exc 6 M mean radius, built in CM 1:6 complete all as specified & directed by Engineer-in-Charge.
M&L for brick work with sub class ‘B’ bricks old size, straight or curved on plan exc 6 M mean radius, built in CM 1:6 but except bricks complete all as specified & directed by Engineer-in-Charge.
Brickwork with sub-class `B' brick straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified & directed by Engineer-in-Charge.
Taking down cement or cement lime plaster of any discription on brick or stone walls/ ceilings etc, including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
M&L Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight) complete all as specified and directed by Engineer-in-Charge.
M&L for 15mm thick rendering in CM 1:6 on any faces of brick or concrete surfaces of walls & finishing the surface even and fair without using extra cement complete all as specified and directed by Engineer-in-Charge
M&L for 15mm thick rendering in CM 1:4 on brick or concrete surface with water proofing compound @ 3% by weight of cement finished other than fair complete all as specified and directed by Engineer-in-Charge. Note : Water proofing compound will be measured and paid seperately under respective item of BOQ.
M&Lwashed stone grit plaster on exterior walls in two layers under layer 12 mm thick cement plaster 1:4 (1 cement 4 coarse sand furrowing the under layer with scratching tool applying cement slurry on the layer @ 3 Kg of cement per sqm, top layer 15mm cement plaster 1:1/2:2 ( 1 cement 1/2 coarse sand :2 stone chipping 10mm nominal size) including panels with groove all around as per approved pattern incl. scrubbing and washing the top layer with brushes and water to expose the stone chippings complete all as specified (payment for providing grooves shall be made separately ).
M&L for forming groove of uniform size 15mm wide and 15 deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens ,nailed to the under layer including removal of wooden battens repair to tha edges of panes and finishing the groove complete as per specifications and directed by Engineer-in-Charge.
Supply only integral water proofing compound complete all as specified and directed by Engineer-in-Charge.
M & L for rendering 10mm thick in CM 1:4 on ceiling surface finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L Preparing newly plastered or un plastered surfaces of wall and applying two coats of oil bound distemper with roller application over a coat of primer over a coat of average 1mm thick wall care putty on new plastered surfaces complete all as specified and directed.
M&L for applying two coats of oil bound distemper with roller on old decorated wall surfaces over primer with 1 mm thick white putty including complete removal of existing treatment with mechanically complete all as specified and directed by Engineer-in-Charge.
Preparing newly plastered or un plastered surfaces of wall and applying two coat of cement base paint over a coat of alkali resistant primer complete all as specified and directed by Engineer-in-Charge
Preparing old or un plastered surfaces of wall and applying two coat of cement base paint complete all as specified and directed by Engineer-in-Charge.
M&L for applying three coats of white wash on ceiling including preparation of new plastered or un-plastered surfaces, complete all as specified and directed by Engineer-in-Charge.
M&L for applying two coats of white wash on ceiling including preparation of old plastered or un-plastered surfaces, complete all as specified and directed by Engineer-in-Charge
M&L for applying three coats of white wash on wall including preparation of new plastered or un-plastered surfaces of walls, complete all as specified and directed.by Engineer-in-Charge.
M&L for complete removal of exsisting treatment with mechanical device of old plastered surfaces of wall and applying two coat of white wash (match with new surface) complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete all as specified and directed. by Engineer-in-Charge.
M&L for Cement concrete 1:2:4 type B-1 ( using 20mm graded crushed stone aggregate) as in benching,coping , roof kerbs, mud stop, padding etc and similar work all as specified and directed by Engineer-in-Charge.
M&L 25 mm thick PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in sub base of flooring finished even and fair without using extra cement complete all as specified & directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) complete all as specified and directed by Engineer-in-Charge.
M&L for coloured glazed ceramic tiles in vertical surface 350 x 250 x 7 mm / 450 x 350 x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match tiles including 10mm thick rendering in CM 1:4 on brick wall complete all as specified and directed by Engineer-in-Charge
M&L for dark shade vitrified ceramic tiles 10 mm thick (square/rectangular) area of each tile not exc. 0.36Sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed or bedding layer of cment mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
M&L for dark shade vetrified ceramic tiles 10 mm thick (square/rectangular) area of each tile exceeding not exc. 0.36Sqm as in skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 10mm thick rendering in CM (1:4) complete all as specified and directed by Engineer-in-Charge.
M&L non skid joint free coloured tiles (1st quality) 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11Sqm but not exc. 0.18 Sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed or bedding layer of cement mortar (1:6) complete all as specified and directed.(toilet,bath,Kitchen) by Engineer-in-Charge.
M&L non skid joint free coloured tiles (1st quality) 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exc. 0.11 Sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 10mm thick rendering in CM (1:4) complete all as specified and directed. by Engineer-in-Charge.
M&L non skid joint free coloured tiles (1st quality) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18Sqm but not exc. 0.38 Sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed or bedding layer of cement mortar (1:6) complete all as specified and directed. by Engineer-in-Charge.
M&L non skid joint free coloured tiles (1st quality) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18Sqm but not exc. 0.38 Sqm as in skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 10mm thick rendering in CM (1:4) complete all as specified and directed.by Engineer-in-Charge.
M&L green marble 18 to 20 mm thick in steps, pillars, window cills, cooking platforms and like in cement mortar (1:4) including painted in white cement (1:2) using marble dust laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including rounding to edge of stone slabs, such as in steps, cooking platforms complete all as specified and directed by Engineer-in-Charge.
M&L Mild steel TMT bars 6mm to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clip complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (reinforced) in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed by Engineer-in-Charge.
M&L RCC Type B0 1:2:4 using (12.5mm graded aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, paddings, balconies, canopies, deck slabs and in shelves complete all as specified and directed by Engineer-in-Charge.
M&L Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, polishing and rounding to edge of stone slabs such as in steps complete laid over and including 20mm thick screed bed CM (1:6) complete all as specified and directed by Engineer-in-Charge.
M&L Machine cut kota stone 20-25 mm thick as in riser of step, skirting,dado and pillar etc. laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone including grinding and polishing laid over and including 15mm thick rendering CM (1:4) complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) in any description and in any position not otherwise specifically provided complete all as specified and directed by Engineer-in-Charge.
M&L for 75mm thick PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in plinth protection and sub base of floor finished even and smooth without using extra cement all as specified and directed by Engineer-in-Charge.
M & L cutting holes into or through brick wall built in cement mortar superfacial area not exc 150 Sqcm and making good in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed by Engineer-in-Charge.
M & L cutting holes into or through brick wall built in cement mortar superfacial area exc 150 Sqcm not exc 400 Sqcm and making good in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed by Engineer-in-Charge.
S&F mild steel joist channel angle or tee sections fixed independently without connecting plates etc of grade Fe-410-W (Gde E-250 quality B) complete all as specified and directed by Engineer-in-Charge.
S&F 5.0 cm thick sand stone slabs in sun shades, chajjas, shelves, roof slabs etc n.exc. 2m in length punched dressed on face and along exposed edges, self faced on other side and set and pointed in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L One coat of epoxy resin (FAIR BOND EP) on old concrete surface @ 0.30 kg/Sqm including preparation of surface as per manufacturer's instruction and applying 25 mm thick on ceiling, beams, chajjas & facia surface etc (average thickness) of cement and sand (fine grit) in ratio 1:4 mixed with chloride free sprey concrete plaster (spray crete) as per manufacturer's instruction with guniting machine of pressure capacity not less than 5kg per Sqm and finished the surface even & smooth in CM 1:4 10 mm thick complete all as specified &as directed by Engineer-in-Charge.
S&F galvanised welded steel wire fabric as extra reinforcement to RCC members like ceilings, chajja’s, beams, columns parapet walls, waste slab etc including all cutting and waste (wt not exc 4.00 kg/Sqm) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 10 ltrs capacity PVC flushing cistern low level (white) with inlet ball valve and handle including flush pipe, brackets, rubber bush, washers etc complete all as specified and directed by Engineer-in-Charge.
S & F in 15 mm bore brass chromium plated mixer hot & cold water screwed down, screwed for iron pipe complete all as specified and directed by Engineer-in-Charge.
S & F 15 mm bore chromium plated fancy bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-Charge.
S&F in repair 15 mm bore CP Stop valve / angle valve screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified & directed by Engineer-in-Charge.
S&F 15 mm bore CP Stop valves, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified & directed by Engineer-in-Charge.
S&F in repair 15 mm bore CP concealed Stop valves, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified & directed by Engineer-in-Charge.
S & F in repair 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall complete all as specified and directed by Engineer-in-Charge.
S & F in repair 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall complete all as specified and directed by Engineer-in-Charge.
S & F 75 mm bore PVC (SWR) bends of any radius complete all as specified & directed by Engineer-in-Charge.
S & F 75 mm bore PVC (SWR) bends with access door of any radius complete all as specified & directed.
S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified & directed by Engineer-in-Charge.
S & F 110 mm bore PVC (SWR) bends with access door of any radius complete all as specified & directed by Engineer-in-Charge.
S&F 110 mm bore PVC (SWR) single T with access door of any radius complete all as specified & directed by Engineer-in-Charge.
S&F in 110 mm bore PVC (SWR) single Y with access door of any radius complete all as specified & directed by Engineer-in-Charge.
S & F 110 mm bore PVC (SWR) cowl of any radius complete all as specified & directed by Engineer-in-Charge.
Taking up or down 15mm bore steel tubing and connection complete all as specified and directed by Engineer-in-Charge.
All as per item No 62 above but 20mm bore
Supply and fixing 20 mm bore tubes medium grade galvanised, with all fitting and fixed complete to walls and ceilings,roofs or laid in floors complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 20 mm bore tubes medium grade galvanised, with all fitting and fixed complete to walls and ceilings,roofs or laid in floors complete all as specified and directed by Engineer-in-Charge.
S & F 20 mm outer diameter of CPVC brass elbow fixing to CPVC pipes any location complete all as specified by Engineer-in-Charge.
S & F 20 mm outer diameter of CPVC brass tee fixing to CPVC pipes any location complete all as specified by Engineer-in-Charge.
Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exc 10 cm girth etc brick wall complete all as specified and directed by Engineer-in-Charge.
S&F in repair vitreous china squatting pan Orissa pattern size 580x440mm white with 'P' or 'S' trap front or back inlet including footrest (excluding fluxing cistern and flush pipe) complete all as specified and directed by Engineer-in-Charge.
S&F in repair vitreous china wash down water closet pan (Pedestal pattern), white with 'P' or 'S' trap incl seat and cover (excluding fluxing cistern and flush pipe) complete all as specified and directed by Engineer-in-Charge.
S&F in repair PVC connection 15mm size with PTMT nuts, 600 mm long complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Vitreous china wash basin white flat back size 550 x 400mm incl waste pipe chain plug brackets complete all as specified and directed by Engineer-in-Charge
S&F in repair 15mm bore, brass chromium plated pillar cock two ways screwed down for pipe and fixed complete all as specified and directed by Engineer-in-Charge.
S&F in repair Waste coupling of PTMT 32 mm dia (half or full threaded) . (Minimum weight 32 mm -45mm) suitable for wash hand basin complete all as specified and directed by Engineer-in-Charge.
S&F in repairs kitchen sink with drainage board made of stainless steel 1mm thick with plugs, washers incl bedding in CM 1:4 to dwarf wall or including cast iron cantilever brackets and connecting union to pipe, overall size 915mm x 460 mm bowl size 410mm x 330mm x 160 mm etc complete all as specified and directed by Engineer-in-Charge.
S&F in repair Waste coupling of CP (half or full threaded) of 40 mm bore suitable for Sink complete all as specified and directed by Engineer-in-Charge.
S&F plate rack of 1mm thick stainless steel of size 900x600mm with three shelves complete all as specified and directed by Engineer-in-Charge.
S & F in repair tubular towel rail 60 cm length of stainless steel 20 mm Dia with brackets type fixed with and including chromium plated brass screws and wooden/plastic cleats complete all as specified and directed by Engineer-in-Charge.
S & F in repairs CP shower rose 125mm dia alongwith shower arm complete all as specified and directed by Engineer-in-Charge.
S&F in repair 150 mm square CP grating complete all as specified and and directed by Engineer-in-Charge.
S&F in repair soap dish brass chromium plated of approximate size 100mmx80mm complete all as specified and directed by Engineer-in-Charge.
S&F sheet glass shelf assembly consisting of 5.50mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n. exc 1.5 Sqm each complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.5 Sqm but not exc 4 sqm each complete all as specified and directed.
Taking down shutter of any description exc 1 Sqm and not exc 2 Sqm each complete all as specified and directed by Engineer-in-Charge.
Refixing the shutters of any description exc 1.00 Sqm but not exc. 2 Sqm each in the same opening or in other opening (incl taking down, easing and also refixing builders hard ware as required and renewal of unserviceable screws complete all as specified and directed by Engineer-in-Charge.
S & F Mild steel Angles, bars, flats etc., as in supports for stiffening of fencing, wall ties, hold fasts, clamps, plain angle cleats for securing purlins and similar small articles confirming to Fe 290 complete all as specified and directed by Engineer-in-Charge.
Mild steel farmed work as in doors (as in ckowkats) or gates of angle or other section with guesst plates brasses rail etc exculsive of steel sheeting or other covering hanging also fastening and fixing complete confirming to Gde Fe-290 (Gde E-165) including shop coat of red oxide including prepration of surface before fixing complete all as specified and directed by Engineer-in-Charge.
M & L for welding repairs exc 2.5cm but n exc 5cm in length thickness of metal to be n exc 5cm in length complete all as specified and directed by Engineer-in-Charge.
S & F 35 mm thick flush shutters solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed by Engineer-in-Charge.
S&F 35 mm thick 2nd class hard wood (Hollock) locally febricated glazed skeleton door shutters open rebated and prepare to receive glass, gauge (without sash bars) edges of framing plain chamfered or rounded, fitted with cut including mitred beads for securing glass etc sizes of members of shutters as specified in SSR Part-I section 8, clause No 8.24 (a) complete all as specified and directed by Engineer-in-Charge.
S&F in 150 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed by Engineer-in-Charge.
S&F in 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed by Engineer-in-Charge.
S&F in 150 mm long aluminium alloy handles, fabricated type, anodised complete all as specified and directed by Engineer-in-Charge.
S&F in 100 mm long medium weight, cold rolled mild steel Butt hinges complete all as specified and directed by Engineer-in-Charge.
S&F in Floor door stopper 150 mm long of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed by Engineer-in-Charge.
S & F in repair mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as spd and dir by Engineer-in-Charge.
M & L for second class hardwood plain fillets exc 13Sqcm and n exc 25 Sqcm, suare, rectangular in section clean sawn secured with nails for cubboard frame work comlete all as specified and directed by Engineer-in-Charge.
S & F 18/19 mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, for cup board shelf fixed with screws to timber frame/welding to steel frame work incl all around wooden beading min 10mm thick with varnishing and flushing with particle board complete all as specified and directed by Engr-in-charge
S & F Continuous (piano) hinges, mild steel, bright finish or electrogalvanised. (30mm Width of flaps when open) complete all as specified and directed by Engineer-in-Charge.
S&F 100 mm long aluminium alloy handles, fabricated type, anodised complete all as specified and directed by Engineer in Charge.
S & F Brass magnet catcher suitable for CB/cabinet shutter complete all as specified and directed by Engr-in-charge
S & F 20mm dia stainless steel pipe for cupboard complete all as spd and dircted by Engr-in-charge by Engineer-in-Charge.
S & F 20mm stainless steel bracket complete all as spd and directed by Engr-in-charge.
Supply & fix factory made solid panel PVC door shutter 30mm thick (style) consisting of frame, made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC , ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for to rail & bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed to getter with solvent cement, supplying & fixing in the frame at site as per specification & drawing for Item No. 08080 on page No 174 of SSR 2020 (Part-II) incl 75 mm long mild steel hinges type B-12, 100 mm long aluminium alloy handles, fabricated type, anodised , 100 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed by Engr-in-charge.
S & F Solid PVC door frame for PVC doors, Kitchen cabinet of size 50mm x 47mm made out of 5mm PVC sheet reinforced with MS square tube, as shown on drawings as per manufacturers specification complete all as specified and directed by Engr-in-charge
S & F PVC door( back side) stopper 75mm long complete all as specified and direction by Engineer-in-Charge.
S&F for framed work such as grills, grating etc. with ends of bars shouldered and/or riveted or forged into spike, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing framed work of water tank and similar work confirming to Fe 290 Gde E-165 complete all as specified and directed by Engineer-in-Charge.
S & F steel windows or ventilator fixed type with glazing bars complete all as apecified and directed by Engineer-in-Charge.
S & F steel windows with side hung shutters incl projecting type hinges with steel handle and steel peg stay, complete all as apecified and directed by Engineer-in-Charge.
Providing & Fixing powder coated aluminium (minimum thickness of powder coating 50 microns) work for Door, window and ventilator frame/shutter powder coated, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long(01 No), hinges type B-21 100mm long (02 Nos) and suitable handle (01 No) etc. complete all as specified and directed by Engineer-in-Charge.
M&L Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, alusters, nosing to steps ncluding embeding in concrete and screwing etc. wind ties for roof including securing oltsposts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Stainless Steel drapery rods, 25mm internal diameter including decorative type brackets and PVC curtain rings 8 Nos per RM including fixing arrangement with drilling holes in walls, brackets etc complete all as specified and directed by Engineer-in-Charge.
S & F Stainless steel wire cloth, 0.71 mm nominal dia of wire fixed with tinned tacks, of 20mm mesh of stainless steel wire staples complete all as specified and directed by Engineer-in-Charge.
S&F 4.0 mm thick Figured glass, pin headed type and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane complete all as specified and directed by Engineer-in-Charge.
S&F 4.0 mm thick shhet glass ordinary quality and glazing with oil putty in square n exc 0.5Sqm in each pane complete all as specified and directed by Engineer-in-Charge.
M&L for applying two coats of synthetic enamel paint (Ordinary tint) over a coat of pink primer including preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth complete all as specified and directed by Engineer-in-Charge.
M & L for applying one coat of synthetic enamel paint including preparation of old wooden surface of any discription not otherwise discribed over 10 cm width or girth, complete all as specified and directed by Engineer-in-Charge.
M & L for applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surface over 10 cm width or girth, not otherwise described complete all as specified and directed by Engineer-in-Charge.
M & L for applying two coats of synthetic enamel paint including preparation of old steel surface over 10 cm width or girth, not otherwise described complete all as specified and directed by Engineer-in-Charge.
S & F 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed complete all as specified and and directed by Engineer-in-Charge.
M&L for treatment of soil under existing floors using emulsion @ one litre per litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement :2 coarse sand) to match the existing floors complete all as specified and directed by Engineer-in-Charge.
M&L for treatment of voids in masonry using chemical emulsion one litre per hole, at 300mm intervals including drilling holes at 45 degree and replugging them with cement mortar 1:2 to match the existing floors complete all as specified and directed by Engineer-in-Charge.
M&L for treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.50 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150 mm centre to centre and sealing the same complete all as specified and directed by Engineer-in-Charge.
M & L (Brushbond RFX) Elastomeric polymer modiffied cemtentitious waterproofing coating used for waterproofing of existing and new maked bricks surface complete all as specified and directed by Engineer-in-Charge.
M & L Cutting out bricks, forming toothing for, and bonding new into old work including value of new materials entering old walls and jointing and pointing (measured on vertical face in contact with old wall only) in CM 1:4 built in cement mortar complete all as spd and dir by engineer-in-Charge.
Cleaning of roughened surface of sunken floor by brushing with wire brush to remove all dirt and applying a coat of cement slurry with 3.00 kg of cement per sqm and rendering 15mm thick in CM 1:3 using WPC finished rough (Sunken floor/Wall) and then applying two course treatment as follow:- (i) Applying bitumen primer @ 0.40 Kg/Sqm. (ii) Laying APP (Atactic polypropylene) modified membrance 3mm thick and weighting not less than 3.50 kg/Sqm with 100 GSM/Sqm non woven polyster mat as centre core reinforcement , laid with 75mm side over lap and 100mm end over lap sealed and finsihed neat. (iii) 40mm bore GI pipe for Spout pipe length 0.75m.
M & L for broken bricks loose filling with aggregates of gauge 40 to 80mm in sunken protion complete all as specified and directed by Engr-in-charge by engineer-in-Charge.
S & F in repairs 75x125mm dia of PVC (SWR) floor trap, plain with grating incl jointing with solvent cement complete all as specified and directed by engineer-in-Charge.
S & F in repairs 125/110 mm dia of PVC (SWR) Gully trap, plain with grating incl jointing with solvent cement complete all as specified and directed by engineer-in-Charge.
Boring holes through cooking platform lining for pipes ,etc n'exc 50mm dia and making good complete all as specified and directed by Engr-in-charge.
Excavation in trenches not exceeding 1.5 M wide and not exceeding 1.5 M in depth for foundation, manholes, etc n.exc 10 Sqm plan and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Demolition and breaking up drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar including concrete bedding and haunching complete all as specified and directed by Engineer-in-Charge.
M&L for 150 mm dia SGSW drain pipes grade ‘A’ laid in trenches and jointed in cm 1:1 complete all as specified and directed by Engineer in charge.
M&L PCC 1:4:8 type D-2, using 40mm graded stone aggregate as in bed of drain pipe including packing under and haunching against the sides of pipes after they are laid and tested for the 150mm dia of pipe complete all as specified and directed by Engineer in charge.
M&L for demolition of reinforced cement concrete of any description and in any position complete all as specified and directed by Engineer in charge.
M&L for providing pre-cast cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in cover (for manholes and drains) including necessary form work set in CM 1:6 with and including demolition complete all as specified and directed by Engineer in charge. (Note :- Reinforcement shall be measured and paid separately)
M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with cli complete all as specified and directed by Engineer-in-Charge.
One cutting of Grining existing marble flooring incl polishing complete all as specified and directed by Engineer in charge.
Providing Acrylic plastic number plate of size 200mmX 200mm X 3mm and writing Room No. of height 10 to 15 cm in any style (bold/italic) and fixed to wall with screws complete all as specified & directed by Engineer in charge.
Waterproofing and damp-proofing treatments are complete all as specified & directed comprising with following (a) M &L Cutting out bricks,forming toothing for, and bonding in CM new into old work including value of new materials entering old walls complete all the specified.(b) M&L 25 mm thick Cement concrete type B-0, 1:2:4 (12.5 mm graded aggregate) as in DPC complete all as specified ( water proofing compound measured sepertely) (c) M & L Applying evenly a coat of blown type bitumen at the rate of 1.50 kg per square metre and linding with clean dry sand @ 0.05 cu. m. per sq. m complete all as specified. (d) M & L Polythene film, 50 micron thick, laid on a coat of bitumen primer complete all as specified by Engineer in charge.
Taking down carefully copper/aluminium point wiring on batten/ PVC conduit (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc, including removal and making good disturbed surfaces of walls, ceilings etc by cement/ colour /plaster to match with the existing location spot complete all as specified & directed by Engineer in charge.
M&L for point wiring concealed type with 1.50sqmm PVC FRLS insulated, unsheathed, single core, multi stranded copper conductor cable 1100 volts grade including 1.5sqmm FRLS PVC insulated unsheathed stranded copper conductor cable as earth continuity conductor drawn in and including rigid PVC conduit of suitable size but not less than 20mm dia with its accessories, sunken type pressed steel terminal box made of 1.2mm thick MS sheet/ anodised steel box painted with one coat of red oxide primer including 3.0 mm thick ISI marked plastic laminated sheet cover for fixing switches/ socket/regulators etc including cutting chases in wall as per standard engineering practice & making good the disturbed surfaces to match with existing for the one light/ fan/street/bell point controlled by 1 one way switch 5/6 Amps complete all as specified & directed by Engineer-in-Charge.
All as per item No-143 here in before but One socket outlet 5/6 Amps on independent bd controlled by one switch but not below the switch board of light points complete all as specified & directed by Engineer in charge.
All as per item No-143 here in before but One socket outlet 5/6 Amps controlled by one switch on same board with other switches complete all as specified & directed by Engineer in charge.
All as per item No-143 here in before but one socket out let 3/5 pin, 5/6 Amps controlled by one 1way switch on independent board but below the switch board of light points in same vertical plane complete all as specified & directed by Engineer in charge.
All as per item No-143 here in before but using 2.5 sqmm PVC FRLS insulated stranded copper cunductor cable and for one socket out let 3/6 pin, 15/16 Amps controlled by one 1 way switch on independent board complete all as specified & directed. NOTE-For item no 2 to 6 -: (i)The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillers etc for concealing the conduits to required depth & making good the disturbed surfaces in cement mortar 1:4 including finishing the surface to match with the existing surface.The portion of point wiring at RCC Coloumns/Beams/Ceilings etc shall be in surface conduit of suitable size fixed on surface with using PVC rawl plug and provision of covering terminal boxes/junction boxes of any shape and size with 3 mm thick bakelight laminated sheet fixed with suitable GI screws and cup washers. (ii) Fittings like switches,sockets,regulators,lamp holders,light foittings shall be measured and paid for separately under appropriate item of schedule A. (iii)The size of conduits shall be determined on permissible no of runs of wires as specified in SSR part-I clause 19.125 (B).However minimum size of conduit shall be 20 mm dia (medium grade)
Supply and fix switch piano, flush type, single pole, 5/6 Amps one way, 230 volts complete all as specified and directed by Engr-in-charge
Supply and fix switch piano, flush type, single pole, 15/16 Amps one way, 230 volts complete all as specified and directed by Engr-in-charge
Supply and fix socket outlet, 5/6 Amps, flush type, 5 pin 230 volts complete all as specified and directed by Engr-in-charge
Supply and fix socket outlet, multi-purpose 3 pin 5/6 Amps and 3 pin 15/16 Amps complete all as specified and directed by Engr-in-charge.
S&F for ceiling rose surface bakelite 62.5 x 25 mm size 3 terminals complete all as specified and directed by Engr-in-charge
S&F switch, bell push button, single pole, 5/6 Amps, one way, 230 Volts complete all as specified and directed by Engr-in-charge
Supply and fix electrical bell model city ding dong (Ding dong type) AC, 230 Volts complete all as specified & directed by Engr-in-charge.
Supply and fix lamp holder insulated body with back plate for batten fitting complete all as specified and directed by Engr-in-charge
Supply & fix rotory stepped type electronic fan regulator mini flush type 100 watt 230 Volts complete all as specified & directed by Engr-in-charge
Supply & fix in replacement, single pole and neutral sheet metal enclosure (AC box) with a two pin & earth plug and socket with one no. MCB SP of capacity 20 Amps 240 volts IK-08 As per IEC 61439-3 complete all as specified & directed by Engr-in-charge.
Supply and fixing LED Bulb 15 watt, single phase, 230 Volts AC supply suitable for lamp holder complete all as specified and directed by Engr-in-charge
Supply & fix surface/wall mounting LED batten 20 watt luminaire having extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver with mounting accessories complete with lamp holders fixed to wall/ ceiling with fixing accessories and connecting up with & including twin twisted copper flexible wire of size 0.75 sqmm from ceiling rose to fittings complete all as specified & directed.
Supply & fix, surface/ ceiling mounting type 34 watt LED luminaire PLUTO NEO PENAL 2X2 environmental friendly new generation aesthetically ultra modern recess mounting with high brightness SMD LEDs as light source with reflector cover electronic driver, connector block etc with internally prewired fixed to ceiling with fixing accessories and connecting up with & including twin twisted copper flexible wire of size 0.75 sqmm from ceiling rose to fittings complete all as specified & directed by Engr-in-charge
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-charge
Supply & fix, outdoor security light LED 36/40 watt luminaire IP 65/66 protection polyster powder coated with pressure die cast aluminium housing and robust construction with reflector cover pre anodised and flat white high transmission acrylic cover or toughened glass, natural white type with electronic driver, connector block etc with internally prewired fixed to building with and including 1.20M long bracket made out of 40mm dia light grade GI pipe bent to shape & providing clamps 2 Nos made out of 50 x 6 mm Flat iron/MS clamps & 12mm dia bolts, nuts & washers etc and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed.
Supply & fix NEW GENERATION POST TOP energy saving envirmental friendly long life 35 watt LED luminaire light fitting, IP 65 protection with reflector cover electronic driver, connector block etc with internally prewired fixed to brcket on gate with fixing accessories and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed by Engr-in-charge
Supply & fix surface mounting type bulkhead 10 watt LED luminaire ENDURA RUGBY NEO IP 65 environmental friendly, altra modern energy saving , decorative oval comprising of high brightness LEDs, connector block etc with internally prewired fixed to wall with fixing accessories and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed by Engr-in-charge. .
Taking down care fully sub main wiring / service connections of any size including batten/ conduit, and making good the disturbed surfaces of wall/ floor complete all as specified and directed by Engr-in-charge
M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 6.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 6.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed by Engr-in-charge. Notes:- Finished sub main wiring with two runs of 6.0 sqmm cable & one run of 6.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 4.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 4.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed by Engr-in-charge. Notes:- Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 4.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
Taking down distribution boards any size any type including MCB TPN/SPN/SP etc and making good the disturbed surfaces complete all as specified and directed by Engr-in-charge
Supply and fix MCB DB vertical type 4 way VTPN sheet metal enclosure 415 volts with 100 Amp fully insulated standard copper bus bar for each face & surrounded with neutral bars and two common neutral bar, two earth bar including cable ties for cable manegement suitable for housing MCCB TPN 415 Volts as incommer, IP-43, IK-09 as per IEC 61439-3 with metal doors all enclosed on standard steel sheet flush mouting type double door factory fabricated complete without MCB & MCCB but with enclosue blank plate complete all as specified and directed.
Supply and fix MCB DB sheet metal enclosure factory fabricated double door SPN 8 way with 100 amps rated copper bus bar 240 volts IP-43, IK-09 with metal doorscomplete all as specified and directed by Engr-in-charge
Supply and fix MCCB 4 pole 100 to 125 Amp Icu 16 Kilo Amp and Ics 100% of Icu with adjustable 70% to 100% and thermal magnetic release suitable for fixing in VTPN DB complete all as specified and directed by Engr-in-charge
Supply & fix Isolator SPN , 40 Amps, 240 volts, 50Hz, IP-20 as per IEC 60947-3 ISI marked complete all as specified & directed by Engr-in-charge.
Supply & fix MCB SP, 40 to 63 Amps, 'C' Curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed by Engr-in-charge.
Supply & fix MCB SP, 6 to 32 Amps, 'C' curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed by Engr-in-charge .
M & L earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm size, buried directly in ground (earth pit not less than 2.25 M deep below normal ground level) with top edge of the plate not less than 1.5 M below normal ground level connected to and including galvanised steel earth lead wire of 4 mm dia, including 15 mm bore GI light grade protection pipe upto 1 Mtr above the floor level of the buildings where main switch, DB etc, situated, earth lead wire connected to the earth plate by means of GI bolts, nuts, washers and earth plate surrounded by 150 mm thick alternate layers of charcoal or cock dust mixed with common salt 20 mm bore medium grade GI watering pipe PCC pit in PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) cover of precast RCC 1:2:4 type B-1(using 20 mm graded stone aggregate) duly reinforced with 8 mm formed or twisted bars @ 100 mm c/c both ways, GI wire mesh, GI sheet funnel necessary excavation in soft/ Looose soil and deposited the surplus soil to a distance not exceeding 50 mtr away from starting point, all as per electrical plate no:3 of SSR part-1 .
M&L for electrically disconnecting and taking down existing ceiling/Exhaust fans from any hight or in any position from existing bldg and keeping in safe custody for reuse at site after necessary repare/ servicing & painting with one coat of synthetic enable paint and writing of MES/identification No. of fans and re hanging/ re-fixing in original position but including replacement of three cor flexible copper conductor cable from ceiling rose to fan connector block of soze 0.75 Sqmm and hanging fan clamps, nuts, bolts and rubber reel bush etc & testing for proper functioning complete all as directed at site by Engr-in- Charge
Supply & Laying, testing ,cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 volt grade, with stranded aluminium conductor of size 25 Sqmm 4 core compele all as specified and as directed by Engr-in-charge
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in soft/loose/ soil for taking out/laying CI/GI pipe line and getting out soft/loose soil complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick layers complete all as specified and as directed by Engineer-in-Charge.
Removal of excavated material n.exc 50 mtr away and depositing where directed at a level n.exc 1.5 mtr above from starting point complete all as specified and as directed by Engineer-in-Charge.
Supplying and laying un-rainforced precast concrete cable cover LV type-I flat size 250 mm x 150 mm x 40 mm in trenches for protection of cable complete all as specified and directed by Engr-in-charge
M&L for sand cushioning dry fine for cable cushioning below and above the cable complete all as directed at site by Engr- in-Charge.
Supply and fixing GI Pipe 40mm Light grade , for cable protection laid in trench under road or path or fixed on pole or wall with clamps with all fittings complete all specified and as directed by Engr-in-charge.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .