Loading…
Loading…
Tender Value
₹33.4 Cr
EMD Value
₹66.9 L
Closing Date
12 Jun 2026, 2:30 pmClosed
Yes (up to 3 members)
No
Two Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
90 days
Expenditure
Capital (Works)
SNTCNTBM
15 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
SIMILAR NATURE OF WORK MEANS:Any Signal interlocking works involving EI OR RRI OR PI OR IBS OR LC GATE INTERLOCKING OR UFSBI OR TRACK CIRCUIT AFTC OR (SSDAC OR MSDAC OR HA-SSDAC) OR Automatic signalling
14 conditions
Requisite EMD and cost of tender document to be paid through payment gateway.
Documentary proof of turnover
A copy of partnership deed and affidavit for proprietorship if applicable
Statement of Deviation, if any.
Experience certificate for Similar works executed
Complete technical data and particulars of the equipment offered
Undertaking by the tenderer that "the equipment for EI / Axle Counter (SSDAC/MSDAC/HASSDAC) / AFTC/ RTU / Datalogger / UFSBI / IPS / Inverter / UPS shall be procured from RDSO approved sources and installation, testing and commissioning of the same shall also be got done from the same source including after sales support required during the warranty period" as mentioned in the eligibility criteria.
Form III to be filled and submitted by tenderers if covered under clause 17 and 18 under "conditions of tender".
Tenderer should advise the number of Engineer, Supervisors and Cable Jointers/Artisans employed by him or going to be employed with their names, qualifications, bio-data and experience in this particular trade under consideration along with the Tender
Irrevocable letters of commitment of the said supervisors and key technicians/artisans for doing the works shall be furnished along with tender papers, if they are not already in employment of the tenderer
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Provision of Electronic interlocking signalling arrangements (Both Indoor and Outdoor)and Telecommunication arrangements at Podanur Junction in connection with 1) New coaching terminal at PTJ 2) Creation of Trip Maintenance/Advance inspection Centre at PTJ 3)Interlocking of stabling line with new EI and by-pass line between CBE-IGU and 4) Development of coach maintenance facilities at PTJ.
TBM-SG-CN-2026-27-02-OT
TBM-SG-CN-2026-27-02-OT
Open
Works - General
10 Months
Chengalpattu, Tamil Nadu
₹0
₹66.9 L
20 May 2026
20 May 2026
29 May 2026
301 items across 1 schedule · ₹18,57,84,354.34 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Supply of fan less embedded industrial grade computers (Similar to Moxa V2406 or better) with a l l accessories such as key board, mouse, antivirus etc. o f industrial g r a d e as per approved Specification as recommended by latest RDSO Specification(RDSO/SPN/192 or 203 or latest) for EI | Numbers | 8.00 | 3,75,562.03 | 30,04,496.24 |
| 2 | Supply of Power Supply arrangement for VDU and Embedded PC. This includes supply of 2 N o s o f 110VDC/24DC, 10A DC-DC converter a n d 2 N o s of 110VDC/110V AC, 500VAInverter in (1+1) configuration.(as per Technical Specification enclosed) | Set | 8.00 | 2,14,096.98 | 17,12,775.84 |
| 3 | Supply and Installation of work space as per enclosed drawing No PROJ/SG/MS/70/2019 - work space (as approved by engineer in charge) with control desk for 2 monitors, 2 operators & one module to be provided for storage - should include space for housing Two nos of Embedded PCs, 2 nos FDMS and their Power supply arrangement for with proper ventilation with two chairs (as per Drawing enclosed or as per site requirement) | Numbers | 1.00 | 9,48,672.1 | 9,48,672.1 |
| 4 | "Training of Railway Personnel in installation, commissioning, testing, troubleshooting and in diagnosing faults u s i n g diagnostic tools/flow charts i n c l u d i n g s u p p l y of necessary documents. (Per Unit= 60 Man Days)" | Per Unit | 4.00 | 72,995.54 | 2,91,982.16 |
| 5 | " C a r r y i n g o u t A u t o m a t i c Factory Acceptance test for a n y station having Distributed EI configuration" | Station | 3.00 | 3,05,105.92 | 9,15,317.76 |
| 6 | "Carrying out Automatic Site Acceptance test for any station having Distributed EI configuration" | Station | 3.00 | 9,73,868.46 | 29,21,605.38 |
| 7 | "Preparation and Submission of NI drawings/ Plans, Rule Diagrams, Station Working Rules, CRS Documents, TSAA documents" | Station | 1.00 | 5,29,000.45 | 5,29,000.45 |
| 8 | "Submission of all relevent final 'As mades' of circuit diagrams, contact analysis charts, termination particulars of apparatus cases and cable termination rack, power supply arrangements, relay index board, cable plans, cable route plans, red boundary plans and all other particulars covered under various schedules. All 'As mades' shall be prepared by the Contractor in AUTOCAD 2000 or latest and submitted in CDs. One copy of the 'As mades' check print shall be submitted before Testing the circuits. The final negatives shall be made in tracing sheet (80 to 90 gsm). All 'As mades' except cable plan, cable route plan, bonding diagram & power supply diagram shall be prepared in A3 size. On approval the contractor shall submit along with the negatives, 8 copies in each, duly making booklet neatly bound. Out of 8 sets, 2 sets of drawings and other plans shall be kept in transparent plastic cover (2 sheets back to back in one plastic cover) and handed over to Railways. Also the contractor has to supply one set of As mades in 'Reproduction Film'. The approved circuit diagram will be issued by Railways in soft copy as well as two sets of hard copies. Wherever alterations to existing circuits are involved, the existing as-made circuit diagrams will be supplied by Railways either in CDs or RP film. The Contractor shall incoporate the details of all the new wirings and alterations in the CD/ RP film and submit them to Railways. Onapproval 8 copies shall be made for As-made circuit diagrams also as mentioned above" | Sheet | 2000.00 | 382.12 | 7,64,240 |
| 9 | P r e p a r a t i o n o f c i r c u i t s , location diagrams, power diagrams, cable plan, bonding plan etc in Auto Cad 200o or latest. The drawings shall b e prepared in A3/A2/U size as required by Railways. The hard copies of the documents will be supplied by Railways. The Contractor has to draw the drawings in Auto Cad very carefully a n d submit o n e copy of check print along with the soft copy in CD. The drawings shall be checked and returned by Railways indicating corrections if any. The corrections have to be made and final copy submitted in A3/ A2/ U size as required by Railways along with the final soft copy in CD. The hard copy given by Railways have to be returned back without any damage. The size of sheet given in the unit column is for the hard copy given by Railways. a) Preparation of soft copy in AUTO CADD from A3 size hard copy | Sheet | 20.00 | 218.3 | 4,366 |
| 10 | Supply of data logger with 512 digital and 96 Analog inputs as per RDSO spec .no IRS-S- 99/2006 o r latest including P o w e r Supply and Back-up arrangements(This w o r k does not includes wiring o f inputs from Relay to Intermediate tag block & from intermediate tag block to Datalogger equipment) | Numbers | 6.00 | 4,94,420 | 29,66,520 |
| 11 | "Supply o f Fault Analysis Terminal for analysis of fault and generating reports for Datalogger installed a t stations. As per Technical Specifications." | Numbers | 1.00 | 54,723.27 | 54,723.27 |
| 12 | Supply of Protocol Converter suitable for Electronic Interlocking system equipment | Numbers | 6.00 | 68,051.41 | 4,08,308.46 |
| 13 | Supply o f Dua l Card RS232 t o EI/OFC converter suitable to insert in the Datalogger Eurorack for inter-linking Datalogger/MFEP | Numbers | 6.00 | 45,367.61 | 2,72,205.66 |
| 14 | Supply of isolation transformer 600:470 ohms a s per IRS TC 76-2001 amd 1 or latest | Numbers | 6.00 | 791.12 | 4,746.72 |
| 15 | "Supply, Installation, Testing and Commissioning of Failure Alarm SMS system integrated with Datalogger. This includes a) Software and configuring the SMS features i n the NMDL/CMU. b) GSM Modem f o r E a c h Network. c)PCI Serial Port Adopter card." | Set | 1.00 | 1,42,809.29 | 1,42,809.29 |
| 16 | "Installation, testing and commissioning of 512 Digital & 96 Analog data logger. This includes transportation of materials to Site location and provision o f Ladder a n d cable trough arrangements including connection to the BRC earth. Also includes carrying out of pre- commission checklist and Networking of datalogger. (This s c h e d u l e doesn't c o v e r w i r i n g and preparation of Simulation chart)" | Numbers | 6.00 | 29,500 | 1,77,000 |
| 17 | Wiring o f Relay Inputs t o Wago Block and Wago block to Datalogger. Necessary Wagos required is included as per schedule | Per Unit | 1500.00 | 285.86 | 4,28,790 |
| 18 | Wiring of Analog Voltages from IPS Room to Datalogger. Necessary Wagos required is included as per schedule | Numbers | 150.00 | 285.86 | 42,879 |
| 19 | Installation o f Fault Analysis Terminal (for analysis o f f a u l t a n d generating r e p o r t s for Datalogger installed at stations) | Numbers | 1.00 | 23,452.83 | 23,452.83 |
| 20 | Installation of isolation transformer 600:470 ohms as per IRS TC 76-2001 or latest | Numbers | 6.00 | 339.05 | 2,034.3 |
| 21 | Supply of indicative type Surge Protection Device as per RDSO Spec. No. SPN/165/ 2023, Version 4.0 Amdt.1 or latest (Lightning and Transient surge protection for power line). The system shall have stage1 (class B) and stage 2 (class C) type against Lightning electromagnetic Impulse configuration. The protection of Type 1 and 2 against Lightning electromagnetic Impulse (LEMP) and other high surge, shall be provided at the incoming of the power line at the stations, LC gates before the power equipment's as per the instructions of Engineer in-charge at site. Supply of surge protection with Potential free contacts shall be of approved make like OBO, DEHN, PHOENIX, LPT or better make. All other miscellaneous materials required for the work shall be supplied by the contractor. (as per Technical Specification enclosed) | Numbers | 6.00 | 22,756.39 | 1,36,538.34 |
| 22 | Supply and Provision of indicative type Class D Surge Protection Device for 24V DC/48V DC ( s p a r k g a p t y p e ) , with Potential Free contacts and installed as per the instructions of t h e Engineer in charge a t site ( OBO, DEHN, PHOENIX, LPI, ZOTUP, HAKEL or better make).All other miscellaneous materials required for installation shall b e supplied b y the contractor. | Numbers | 35.00 | 6,328.8 | 2,21,508 |
| 23 | Supply and Provision of indicative type Class D SPD of Operating Voltage of 110V AC/DC with Potential Free contacts and installed as per the instructions of the Engineer in charge at site (OBO, DEHN, PHOENIX, LPI, ZOTUP, HAKEL or better make). All other miscellaneous materials required for installation s h a l l b e supplied b y the contractor. | Numbers | 35.00 | 6,830.72 | 2,39,075.2 |
| 24 | Supply and Provision of Earthing a s per RDSO Specification RDSO/SPN/197/2008 or latest (as per Technical Specification enclosed) | Numbers | 35.00 | 28,118.51 | 9,84,147.85 |
| 25 | Supply and Installation of Copper tape of size 25mm x 3mm for Down conductor from Franklin Rod to Maintenance free earth. This work includes installation of insulated stand-offs a t e v e r y 1 Mtr. interval for fixing the Copper tape. This work also includes Exothermic welding o f Copper tape t o the Franklin rod and the maintenance free earth for high conductivity. (All the materials required for the above work shall be supplied by the Contractor) | Metre | 350.00 | 690.54 | 2,41,689 |
| 26 | " S u p p l y a n d p r o v i s i o n o f Earthing arrangements for EI/MSDAC buildings as per RDSO specifications a s required for the EI system along with supply of all required materials. Earthing s h a l l be carried out as per RDSO/SPN/197/2008 and RDSO Lr .No STS/L/SSI/CA/US&S Dt 2 6 . 0 7 . 2 0 1 1 forTypical Earthing connections for EI. Painting of earthing diagram as replica of the ground on backside wall o f relay room a s p e r the instruction o f Site In-charge.(Per unit= Per goomty/station)" | Per Unit | 6.00 | 2,91,723.2 | 17,50,339.2 |
| 27 | Supply o f earth electrodes (G I) a s per Drg no SG/CN/02/13 | Numbers | 55.00 | 1,618.75 | 89,031.25 |
| 28 | Provision of earth electrodes as per drawing No.SG/CN/02/13 and earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, SM's room for block and control, and earthing of all equipments in apparatus cases, power room, relay rack, cable termination rack, control panel, signals, lever frames with MS flat 35mm X 6mm/19c cable (MS flat for closer by areas and MS flat/19c cable combination for farther areas) as per the instructions of Railway representative at site. The work includes painting of earth resistance value on the earth pit. (Supply of 19C cable is not covered in the scope of this schedule). [MS flat for earthing 35mm X 6mm, cement, GI earth electrodes, common salt, charcoal, country bricks, M sand, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 55.00 | 1,707.55 | 93,915.25 |
| 29 | "Full Location: Supply and fixing of GI Flat of size 1050x25x3mm a s given in enclosed drawing t o connect a l l cable armours to earth point with suitable nuts/bolts as given below. A) GI nuts/bolts of size 8x25mm with Two flat and one spring washer o f 23set. B ) GI nuts/bolts of size 12x40mm with two flat and one spring washer of 02set as per site incharge" | Location Box | 42.00 | 1,370.66 | 57,567.72 |
| 30 | "Half Location: Supply and fixing of GI Flat of size 550x25x3mm a s given in enclosed drawing t o connect a l l cable armours to earth point with suitable nuts/bolts as given below. A) GI nuts/bolts of size 8x25mm with Two flat and one spring washer o f 23set. B ) GI nuts/bolts of size 12x40mm with two flat and one spring washer of 02set as per site incharge" | Location Box | 20.00 | 846.75 | 16,935 |
| 31 | "Installation of 230V Class B & Class C Surge Protection Device. This includes transportation o f m a t e r ia ls t o site. Installation to be carried out a s per the direction o f R a i l w a y Engineer. Necessary copper wire for Power Wiring and connecting the earth to be supplied a s p a r t o f the schedule. All other miscellaneous materials required for installation s h a l l b e supplied b y the contractor." | Numbers | 6.00 | 9,752.74 | 58,516.44 |
| 32 | Supply o f 12-Channel E a r t h Leakage Detector a s p e r R D S O Specifications RDSO/SPN/256/2002 or latest | Numbers | 8.00 | 1,50,841.73 | 12,06,733.84 |
| 33 | Supply of DC-DC Converter of Capacity 110V DC/24-40V, 5A a s p e r RDSO Specifications RDSO/SPN/165 /2012 Ver 3.0 or latest | Numbers | 10.00 | 18,095.3 | 1,80,953 |
| 34 | Supply of DC-DC Converter of Capacity 110V DC/24-40V, 10A as per RDSO Specifications RDSO/SPN/165 /2012 Ver 3.0 or latest | Numbers | 10.00 | 21,381.6 | 2,13,816 |
| 35 | Supply and Fabrication of Power Equipment Stand at stations/Huts/Power r o o m at station. As per drawing enclosed | Numbers | 6.00 | 26,575.63 | 1,59,453.78 |
| 36 | Supply of Stackable type VRLA batteries 2V, 200Ah - 1 c e l l a s p e r RDSO Specifications IRS S: 93/96 with Amnd 1 or latest | Numbers | 240.00 | 4,074.88 | 9,77,971.2 |
| 37 | "Supply, installation and wiring of 230/24V - 1A transformer rectifier conforming to RDSO spec. IRS S 91/2014 with latest Amendment in power room for LVR" | Numbers | 6.00 | 12,335.32 | 74,011.92 |
| 38 | Supply of IPS to suit 6 Line RE station as per RDSO Specifications RDSO/SPN/165 or latest (This schedule does not include Batteries) As per drawing enclosed | Set | 5.00 | 13,07,398.11 | 65,36,990.55 |
| 39 | Supply o f L o w maintenance secondary cells of t h e following capacities with necessary inspection a s per s p e c i fi c a t i o n / drawing/ description enclosed in this document.b)Supply of Secondary cells - 2V-80AH capacity | Numbers | 302.00 | 3,379.2 | 10,20,518.4 |
| 40 | Supply o f L o w maintenance secondary cells of t h e following capacities with necessary inspection a s per s p e c i fi c a t i o n / drawing/ description enclosed in this document. e) Supply of Secondary cells - 2V-300AH capacity | Numbers | 60.00 | 9,574 | 5,74,440 |
| 41 | Supply of track feed battery charger IRS:S 89-2013 | Numbers | 83.00 | 4,375.25 | 3,63,145.75 |
| 42 | Supply of 'B type choke IRS:S 65-83 | Numbers | 166.00 | 2,855.6 | 4,74,029.6 |
| 43 | Supply, fabrication and provision of suitable power equipment stand i n the power room at stations (with more than 5 r o a d s ) usingM.S. Angles 65mm x 65mm x 8mm and MS flats 5 0 m m x 6 m m c o v e r e d with 1 0 0 m m x 5 0 m m hardwood reapers, installation of power equipments and wiring the s a m e u s i n g w i r e PVC 7/1.4mm and 3/0.75mm copper a s per approved wiring diagram, fabrication and installation of Power panel Box type using powder coated 16G MS sheet with inbuilt locking facility with a power distribution board fitted inside made of Phynolic synthetic industrial fibre base fi n e weave cotton fi b r e sheet o f size 1200mm X 1 2 0 0 m m X10mm. Terminations using circuit breakers, HRC fuse blocks and PBT terminals shall b e provided o n the phynolic sheet. DIGITAL Voltmeters, ammeters a n d by pass switches shall be fitted on the front side o f the M S power panel. This work i n c l u d e s i n s t a l l a t i o n of power d i s t r i b u t i o n d i a g r a m b o a r d using phynolic sheet 6mm thick of size 1800mm x 1200mm w i t h Aluminium grooved channel frame i n t h e relay room. T h e particulars shall b e digitally u s i n g g o o d quality laminated gum sheet. (Supply o f power equipments is not covered in this schedule).[MS angles 65mmx65x8mm, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet o f size 1200x1200x10mm, H a r d W o o d p l a n k s for reapers 100x50mm, P o w e r c o a t e d 1 6 G MS sheet, teakwood base planks 2 5 m m x 150mm and 50mm x 50mm for fixing cables, 50mm, bolts & nuts required for manufacturing p o w e r p a n e l & power rack, circuit breakers, H RC Fuses with base and carrier, ammeters, voltmeter- 3 Nos., by- pass switches for stabilisers- 63A capacity - 3 Nos., power distribution diagram board using phynolic s h e e t - 6 m m t h i c k o f size 1200X1800mm with Aluminium grooved c h a n n e l f r a m e , p a i n t s , w i r e PVC 7/1.4mm and 3/0.75mm copper, and all other miscellaneous materials required shall be supplied by the Contractor | Set | 1.00 | 2,19,668.82 | 2,19,668.82 |
| 44 | Supply, fabrication and provision of suitable power equipment stand i n the power room at stations (up to 5 roads) using M.S.Angles 65mmx65mmx8mm and MS flats 50mmx6mm covered with 100mmx50mm hardwood reapers, installation o f power equipments and wiring the same using wire PVC 7/1.4mm and 3/0.75mm copper as per approved wiring diagram, manufacture of power panel using phynolic sheet 1200mm x 1200mm x 1 0 m m and erecting i t using MS angles 25mm x 25mm x 6mm and fixing of meters, s t a b i l i z e r a n d a m m e t e r b y pass s w i t c h e s , H R C f u s e b l o c k s , PBT terminals 60mm centre and connecting t h e power equipments t o t h e power panel a s per approved power diagram, i n t h e power room. This work includes i n s t a l l a t i o n of power distribution diagram b o a r d using phynolic sheet 6mm thick of size 1200mm x 1200mm with Aluminium grooved channel frame i n the relay room. The particulars shall b e d i g i t a l l y u s i n g g o o d quality laminated gum sheet. (Supply o f power e q u i p m e n t s l i k e battery charger, transformers, transformer rectifiers, voltage stabilisers, D C - D C convertor, invertors etc., i s n o t included i n this schedule). | Set | 4.00 | 1,61,805.53 | 6,47,222.12 |
| 45 | "Supply of Modular terminal block as per RDSO specification No 18/2004 or latest which consists a s p e r following: a) 2 Conductor disconnect t y p e terminal block as per Model No wago 280-870 or similar - 6 N o s b ) E n d Plate type 280- 374 suitable for disconnect terminal of Model No wago 280-870 or similar - 1 N o c) End Stop terminal block type as per model no wago 249-117 or similar - 2 Nos d) Shorting Links (16A) as per Model wago 280-402 or similar- 1 No" | Set | 300.00 | 772.74 | 2,31,822 |
| 46 | Supply o f Modular Terminal B l o c k of 2.5sq.mm 2 IN 2 OUT type disconnect type of Wago/Phoenix make or similar along with accessories a s p e r RDSO Spec.No.RDSO/SPN/189/2004/ rev 2 or latest. | Numbers | 2000.00 | 194.95 | 3,89,900 |
| 47 | "Supply o f F U S E terminals block with LED indication upto 2.5sq.mm screw type 1 IN 1 OUT ( Suitable 400mA, 630mA, 1A, 1.6A, 2A, 4A, 6.3A, & 10A) (Without Fuse) as per RDSO Spec.No.RDSO/SPN/189/2004/ r e v 2 or latest." | Numbers | 150.00 | 219.87 | 32,980.5 |
| 48 | Supply of DIN channel for the terminal | Metre | 60.00 | 344.87 | 20,692.2 |
| 49 | S u p p l y o f E N D p l a t e s f o r modular terminal block | Numbers | 30.00 | 36.86 | 1,105.8 |
| 50 | S u p p l y o f E N D c l a m p f o r modular terminal block | Numbers | 30.00 | 26.35 | 790.5 |
| 51 | Supply of Shorting Link insulated Grey in color | Numbers | 60.00 | 21.2 | 1,272 |
| 52 | Supply o f operating tool, screw driver and stripper for modular terminal. These tools shall be of Wago/Phoenix make or similar and model suitable for the modular terminal supplied | Numbers | 3.00 | 12,246.29 | 36,738.87 |
| 53 | Supply of FUSE links of (400mA, 630mA, 1A, 1.6A, 2A, 4A, 6.3A & 10A) | Numbers | 150.00 | 61.74 | 9,261 |
| 54 | Supply o f Distilled water for topping of secondary cells to be supplied at site, IS 1106 | Litre | 200.00 | 11.08 | 2,216 |
| 55 | "Supply of distilled water plant similar to'KILBURN' make capacity 3.5 to 4.5 Lits. per hour, with two detachable heating elements of 1500W each to work on 230VAC, single phase, fitted with automatic cut-outs and removable connectors, with Stainless Steel boiling chambers, condenser pipe, toughened glass lid; Distilled water plant, tank 200 Litres capacity similar to sintex make, GI pipe 25mm dia, power plug with socket, regulating valves, jelly, cement, sand and other materials shall be supplied by the Contractor" | Numbers | 1.00 | 25,774.2 | 25,774.2 |
| 56 | "Installation of distilled water plant with provision o f w a t e r s u p p l y connection from water t a p t o w a t e r t a n k , water tank to distilled water plant using G.I Pipes 25mm dia and with regulating valve s, provision of separate power supply s o c k e t a n d wiring. This work includes fixing of 2 Nos. of rails on the w a l l a n d grouting a s instructed by Railway representative at site. (Cut rails will be supplied by Railways)." | Numbers | 1.00 | 11,745.65 | 11,745.65 |
| 57 | Installation of 12-Channel Earth Leakage Detector. This includes transportation of materials t o Site location and provision of cable trough arrangements including connection to the BRC earth.Also includes carrying out of pre-commission checklist. | Numbers | 8.00 | 13,725.36 | 1,09,802.88 |
| 58 | Installation of Power Panel for IPS Room | Numbers | 7.00 | 7,246.46 | 50,725.22 |
| 59 | Commissioning of IPS, this schedule includes arrangement o f O E M engineer f o r checking the Installation and carrying out adjustments of IPS modules a n d submission o f Pre- commissioning checklist | Set | 5.00 | 59,000 | 2,95,000 |
| 60 | Installation, wiring and testing of IPS as per RDSO Specification No. RDSO /SPN /165 or latest.This w o r k includes transporting the IPS from the Stores by loading without any damages and installation of the same at site. This also includes wiring o f a l l modules, proper earthing of equipments and all other w o r k s c o n n e c t e d f o r t e s t i n g and commissioning o f the same. Necessary p o w d e r e d c o a t e d A lu m in iu m ladder arrangements including cable trench, pipes, bolts, a n d other accessories is included in this schedule.[Earthing is not covered under this schedule] | Set | 5.00 | 77,160.07 | 3,85,800.35 |
| 61 | Fixing o f Modular terminal block/fuse block along w i t h accessories with provision of fixing h o l e s o n hylam sheet/side angles of Location B o x and fixing by Galvanized nuts and bolts. This includes fixing of DIN channel for cable termination on Modular terminal | Numbers | 1000.00 | 28.97 | 28,970 |
| 62 | Supply o f 2 4 C o r e x 1 . 5 Sq.mm PVC i n s u l a t e d Armoured, unscreened underground Railway Signalling copper cable as per IRS: S-63/2014 REV.4 | Metre 80000.00 | — | 388.15 | 3,10,52,000 |
| 63 | Supply of 12Cx1.5 SQMM PVC insulated Armoured, unscreened underground Railway Signalling copper cable a s per IRS: S-63/2014 REV.4 | Metre 55000.00 | — | 215.92 | 1,18,75,600 |
| 64 | "Supply o f 2x2.5 sq.mm P V C insulated Armoured, unscreened, underground Railway Signalling Copper cable a s per spec IRS.S.63/2014(Rev.4.0) or latest" | Metre 23500.00 | — | 98.76 | 23,20,860 |
| 65 | S u p p l y o f 2 x 0 . 5 S q m m (16/0.20) Flexible Annealed Tinned Copper (ATC) PVC Insulated T w i n Tw i s t e d Un Sheathed Cable IRS:S: 76/89 w i t h all latest amendments (Red & Black) | Metre | 500.00 | 15.34 | 7,670 |
| 66 | "Supply o f 1x0.5 Sq.mm (16/0.20mm) Flexible ATC PVC Insulated Unsheathed Single Core Cable as per IRS:S: 76/89 with all latest amendments" | Metre | 500.00 | 7.08 | 3,540 |
| 67 | Supply of 16 Sq.mm multistrand Flexible APC PVC insulated copper cable a s per IS 694 | Metre | 1000.00 | 228.14 | 2,28,140 |
| 68 | Supply of 35 Sq.mm multistrand Flexible APC PVC insulated copper cable a s per IS 694 | Metre | 1000.00 | 475.77 | 4,75,770 |
| 69 | S u p p l y o f 7 0 s q . m m m u l t i strand Flexible APC PVC insulated copper cable a s per IRS:S: 76/89 with all latest amendments. | Metre | 500.00 | 814.2 | 4,07,100 |
| 70 | " S u p p l y o f 6 0 C x 1 m m S o l i d PVC Insulated, Binder Ta p e d a n d PVC Sheathed Unarmoured Cable as per IRS:S: 76/89 with all latest amendments" | Metre | 2500.00 | 696.2 | 17,40,500 |
| 71 | S u p p l y o f Underground j e l l y fi l l e d 6 QUAD, 0.9MM D i a a s p e r spe c IRS:TC 30-05 with amd 5 or latest | Metre 43000.00 | — | 301.05 | 1,29,45,150 |
| 72 | Supply of 24 Fibre armoured OFC cable as per R D S O Specification RDSO/SPN/TC/ 110/2020 Rev. 0 or latest | Metre | 5000.00 | 95.23 | 4,76,150 |
| 73 | Supply of 48 Fibre armoured OFC cable as per R D S O Specification RDSO/SPN/TC/110/2020 Rev. 0 or latest | Metre 40000.00 | — | 126.32 | 50,52,800 |
| 74 | Supply of Polythene Insulated Polythene S h e a t h e d a r m o u r e d J e l l y Filled Telephone Cable with Poly-AL Moisture Barrier, 20 Pairs, 0 . 6 3 M M Conductor Diameter as per RDSO Specification No. IRS:TC-41/97 with amendment 1 or latest | Metre | 2000.00 | 258.2 | 5,16,400 |
| 75 | Supply of Polythene Insulated Polythene S h e a t h e d a r m o u r e d J e l l y Filled Telephone Cable with Poly-AL Moisture Barrier, 50 Pairs, 0 . 6 3 M M Conductor Diameter a s perRDSO Specification No. IRS:TC-41/97 with amendment 1 or latest | Metre | 1500.00 | 354.74 | 5,32,110 |
| 76 | Supply of FCPC To SCPC 5 meter long patch cords with 0 d b adaptors a s TEC spec G/OJC-O1/03 JAN 99 or latest. | Metre | 30.00 | 832.51 | 24,975.3 |
| 77 | "Supply of OFC Patch cord (FC-PC/SC- PC/LC- PC to FC-PC/SC-PC/LC-PC so as to suit for switches and FMS supplied)" | Metre | 30.00 | 374.03 | 11,220.9 |
| 78 | supply of switch board cable, finolex/Deltron make o r better 0.5mm, 20 pair conforming to IRS/TC/24-91 | Metre | 3000.00 | 102.81 | 3,08,430 |
| 79 | Supply of UTP Cable /CAT6/6A cable ETL or UL or CE3P certified panduit or Systimax or R&M o r A M P o r Molex or Krone Or D-LinkMakes | Metre | 3300.00 | 34.73 | 1,14,609 |
| 80 | Supply of PVC insulated, unsheathed, Flame retarding t y p e S i n g l e core fl e x i b l e wire 16/0.2 m m d i a . With annealed, tinned copper conductor of colour code ( Red =50%,Black=50%,) a s p e r IRS-S-76/89 Amd- 3(with amdt. upto date if any). | Metre 10000.00 | — | 6.83 | 68,300 |
| 81 | S u p p l y a n d fi x i n g o f 2 0 p a i r Krone module housed in MS box and termination of Cables | Numbers | 5.00 | 3,962 | 19,810 |
| 82 | Supply and fixing of 20 pair CT box and termination of cables | Numbers | 9.00 | 4,761.16 | 42,850.44 |
| 83 | "Supply of 10way Annunciator with Push button switches and having conference facility. M o d e l N o A M - 1 0 s i m i l a r to Epsilon, Telelinks or better" | Numbers | 1.00 | 17,790.89 | 17,790.89 |
| 84 | Supply a n d provision o f normal joint using Thermo shrink jointing kit (RDSO s p e c s No TC/77/2012 ( Re v. 3 ) with amendment No.1&2 o r latest.& jointing k i t t o be inspected b y RDSO) f o r 4/6 q u a d cable normal j o i n t . The work includes excavation of joint p i t o f size 1mX1.5mX1.5m and closing t h e same after completion of cable joint as per the instruction of Railway representative at site. | Numbers | 28.00 | 4,628.91 | 1,29,609.48 |
| 85 | Supply and provision o f derivation joint complete f o r 6 Q u a d c a b l e s using thermoshrink jointing kit for LC's/stations | Numbers | 4.00 | 4,901.27 | 19,605.08 |
| 86 | Supply and installation of 24 Fibre Joint enclosure f o r armoured optic a l fibre cable conforming t o RDSO spec.RDSO/SPN/TC/68/2014 rev2.0 or latest | Numbers | 8.00 | 13,647.37 | 1,09,178.96 |
| 87 | Supply and installation o f 4 8 fibre Joint enclosure f o r armoured optic a l fibre cable conforming to RDSO spec.RDSO/SPN/TC/68/2014 rev2.1 or latest | Numbers | 20.00 | 20,060 | 4,01,200 |
| 88 | Supply of RCC cable markers (Supply of RCC cable markers a s p e r drawing No.CSTE/CN/OFC/1. The lettering on the cable marker shall be "SIG" / "TELE" / "OFC" as per the instructions of Railway representative a t site.) as per drawing enclosed | Numbers | 330.00 | 262.65 | 86,674.5 |
| 89 | Preparation of Cement concrete for covering of GI Pipes/cables. Providing & Laying in position cement concrete of specified proportion including c o s t of cement, centering a n d shuttering with 1:3:6 composition 1 Cement: 3 Sand: 6 grade stone aggregate 25mm nominal size) (Cement, M-Sand, stone jelly of 25mm and all o t h e r m i s c materials r e q u i r e d f o r the work should be supplied by Contractor). | cum | 2000.00 | 9,361.46 | 1,87,22,920 |
| 90 | Laying o f STP/OFC/Power Cable/ switch board (10 pair/ 20 pair/50 pair) Cables in 1" PVC conduit/case c a p i n g and clamping on the wall/Roof tops/ Shelters with suitable clamping a n d hose t o be provided where ever bends/ curves (PVC c o n d u i t / Case capping and other accessories to be supplied by the contractor) | Metre | 3500.00 | 37.3 | 1,30,550 |
| 91 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. (Laying of cables is not included in this schedule) | Metre 13000.00 | — | 64.1 | 8,33,300 |
| 92 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 0.5 Mtrs a n d t o a width o f 0 . 3 Mtrs. (Laying of cables is not included in this schedule.) | Metre | 1000.00 | 32.05 | 32,050 |
| 93 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.5 Mtrs. (Laying of cables is not included in this schedule.) | Metre | 1000.00 | 79.51 | 79,510 |
| 94 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 0.5 Mtrs and to a width of 0.5 Mtrs. (Laying of cables is not included in this schedule.) | Metre | 500.00 | 39.82 | 19,910 |
| 95 | Breaking o f Platform concrete having 0.3 feet thickness - 0.5 feet thickness and to a width o f 0 . 3 M t r using cutter machine and removal o f RC C slabs on the Passenger Platform, trenching t o a d e p t h o f 0 . 6 m to accommodate the additional cables, replacing the slabs removed after the cables are laid and r e p l a s t e r i n g w i t h cement mortar, refilling the trench by ramming and consolidating it as per the instructions of Railway Representatives at site. (Laying o f c a b l e s i s n o t i n c l u d e d i n this schedule). | Metre | 400.00 | 2,224.44 | 8,89,776 |
| 96 | Excavation of trench along route of existing cable duct, opening the slabs to accommodate additional c a b l e laying, REPOSITIONING the slabs removed after the cables are laid and PLASTERING with cement mortar, and refilling the trench by ramming and consolidating it as per the instructions of Railway Representatives a t s i t e . ( L a y i n g of cables is not included in this schedule.) [Cement,M Sand and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Metre | 500.00 | 161.92 | 80,960 |
| 97 | Excavation of trench to a depth of 1 Mtr. for track crossing of cables, refilling of trench by ramming and consolidating i t a s p e r the instructions of Railway representative at site after l a y i n g o f D W C / RC C p i p e s . During excavation o f t r e n c h , i t h a s t o be ensured that the excavated soil does not mix with the ballast available. The depth o f 1 m trench shall b e fro m the bottom o f sleepers for track crossings. Laying o f cables and DWC pipes is not included in this schedule. (Supply of DWC/RCC pipes with couplers/collars is not included in this schedule). | Metre | 2000.00 | 385.45 | 7,70,900 |
| 98 | Excavation of trench to a depth of 1 Mtr. for road crossing of cables, laying of DWC/ RCC pipes with collar/ coupling, refilling of trench by r a m m i n g and consolidating it and resurfacing it to the original position. Laying of cables is not included in this schedule. (Supply of DWC/RCC pipes with couplers/collars is not included in this schedule). | Metre | 100.00 | 501.03 | 50,103 |
| 99 | Provision of GI pipes (50/100mm dia) for cable laying with offset at both ends and with couplings over RCC bridges, drainage, culverts, and girder bridges. For RCC bridges, drainage, and culverts, the pipes shall be mounted on concrete masonry supports of size 300mm x 300mm x 300mm at an interval of 2 meters. For girder bridges, the pipes shall be fixed on suitable MS clamps at an interval of 2 meters. The ends of the pipes shall be closed with brick masonry abutments to ensure that no cable is exposed. The work shall be carried out as per the instructions of the Railway representative at the site. (Supply of GI pipes with couplings and laying of cables is not included in this schedule).Stone jelly (20/25mm size), bricks, sand, cement, MS angles, flats, bolts, nuts for manufacturing and fixing clamps, bricks, M sand, cement, and other miscellaneous materials for the work shall be supplied by the contractor. | Metre | 620.00 | 208.54 | 1,29,294.8 |
| 100 | Provision of GI pipes 50mm/100mm dia on excavated trenches/platforms/over the ground without abutments and supports | Metre | 108.00 | 118.22 | 12,767.76 |
| 101 | Provision of GI pipes (50/100mm dia) for cable laying in hard rocky area with off sets at b o t h e n d s d u l y supported by concrete blocks of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall b e closed with brick masonry abutments work so that no cable is exposed, The work shall be carried o u t a s p e r the instructions of Railway representative at site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule). [Stone jelly of size 20/25mm, bricks, sand, cement, a n d a l l other miscellaneous materials required for the w o r k s h a l l be supplied by the Contractor]. | Metre | 3000.00 | 182.87 | 5,48,610 |
| 102 | L a y i n g o f signaling/power/ telecommunication cables a s p e r cable plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc. (Supply of cables is not included i n this schedule). | Metre 246500.00 | — | 18.18 | 44,81,370 |
| 103 | "Refilling of cable trench 1m depth by 0.3m width throughout, with earth after laying of cables, a n d consolidating the trench by ramming and levelling." | Metre 13000.00 | — | 15.4 | 2,00,200 |
| 104 | "Refilling of cable trench 0.5m depth by 0.3m width throughout, with earth after laying of cables, and consolidating the trench by ramming and leveling." | Metre | 1000.00 | 7.77 | 7,770 |
| 105 | "Refilling of cable trench 1m depth by 0.5m width throughout, with earth after laying of cables, a n d consolidating the trench by ramming and levelling." | Metre | 1000.00 | 19.29 | 19,290 |
| 106 | "Refilling of cable trench 0.5m depth by 0.5m width throughout, with earth after laying of cables, and consolidating the trench by ramming and levelling." | Metre | 500.00 | 9.3 | 4,650 |
| 107 | "Digging of pit to a depth of 800mm of size 300mmX300mm, c a s t i n g of concrete foundation o f size 300mmX300mmX300mm and Placing of RCC cable markers on top of the foundation a n d refilling t h e p i t and consolidating i t b y ramming. The cable markers shall be provided at an interval of 20 Mtrs. within station limits and 50 Mtrs. outside station limits throughout the cable route, diversions a n d also at every track/road crossing." | Numbers | 330.00 | 123.35 | 40,705.5 |
| 108 | Excavation o f cable coil pit t o a size of 1.5mx1.5m and depth a s instructed by Railway representative at site, for coiling the cables in rear of relay rooms/ A F TC huts, apparatus cases e t c . The work includes coiling t h e underground cables and placing closely one layer of country bricks of size approx. 220mm x 100mm x 60mm breadth wise above the cables to cover all the cables in the cable pit, closing and consolidating the pit by ramming and levelling.[Country bricks of size 220mmx100mmx60mm (approximately) shall be supplied by the Contractor]. | cum | 100.00 | 949.05 | 94,905 |
| 109 | Cutting o f rock t o a depth o f 2 0 0 mm and width of 200 mm where rock is visible from surface to a depth more than 300 mm up to 550mm, excavation of trench with width 300mm above rock concreting 200mmx200mm after laying of cable with / cement: 2 sand : 4 graded stone aggregate 20mm nominal size and curing of concrete to the required number o f days, refilling with excavated soil ramming and consolidation except i n bridges, c u l v e r t s , l e v e l crossings, track c r o s s i n g s , c a b l e p i t s , r o c k y soil including marking o f cable alignment, clearing of debris etc., complete to the finished item of work as directed by site in charge. D r g No.SK/CN/NEW/3. All thematerial is to be arranged by contractor | Metre | 1000.00 | 314.85 | 3,14,850 |
| 110 | "Road crossing/ Track Crossing through Horizontal Drilling at approximately depth of 1.5 to 2m below the formation level of the earth including insertion of HDPE pipe/DWC pipe along with couplers, drawl of cable (or) direct drawl o f cables e t c . (Note: T h e pilot used for HDD should be of sufficient size to suit insertion of HDPE /DWC pipe o f size 120mm (outer dia.) or direct drawl of three cables (Signalling/Power/Quad/OFC) or three nos.of 40mm dia HDPE pipe or any other combination a s directed b y t h e site engineer) ( Supply o f HDPE pipe i s not covered in this schedule)" | Metre | 1250.00 | 1,351.45 | 16,89,312.5 |
| 111 | Blowing/Drawing o f O F C cable/Power c a b l e / S i g n a l l i n g c a b l e inside permanently solid lubricated HDPE Pipe already laid. This work includes necessary duc t integrity test for solid lubricated H D P E pipe. ( This includes Tr a n s p o r t a t i o n o f m a t e r i a l s from nominated stores to site) | Metre 45000.00 | — | 23.43 | 10,54,350 |
| 112 | Supply of Main LED Signal Aspect - Green as per R D S O Specifications No.RDSO/SPN/199/2010 Rev1.1 or latest | Numbers | 35.00 | 10,030 | 3,51,050 |
| 113 | Supply of Main LED Signal Aspect - Yellow as per RDSO Specifications RDSO/SPN/199/2010 Rev1.1 or latest | Numbers | 50.00 | 8,850 | 4,42,500 |
| 114 | Supply of Main LED Signal Aspect - Red as per RDSO Specifications RDSO/SPN/199/2010 Rev1.1 or latest | Numbers | 60.00 | 9,233.5 | 5,54,010 |
| 115 | Supply o f subsidiary S i g n a l A s p e c t - Route LED a s p e r RDSO Specifications S P E C I F I C A T I O N NO. RDSO/SPN/153/2023 Revision 5.0 or latest | Numbers | 150.00 | 5,703.33 | 8,55,499.5 |
| 116 | Supply of subsidiary Signal Aspect - Calling on L E D a s p e r RDSO Specifications SPECIFICATION NO. RDSO/SPN/153/2023 Revision 5.0 or latest | Numbers | 55.00 | 5,726.13 | 3,14,937.15 |
| 117 | Supply o f subsidiary S i g n a l A s p e c t - Shunt LED a s p e r R D S O Specification S P E C I F I C A T I O N NO. RDSO/SPN/153/2023 Revision 5.0 or latest | Numbers | 55.00 | 5,740.7 | 3,15,738.5 |
| 118 | Supply o f Multi L a m p Route indicator (LED Double Digit) f r o m 1 t o 9 with w h i t e LED (With Housing) as per technical specification | Numbers | 2.00 | 64,900 | 1,29,800 |
| 119 | S u p p l y a n d p r o v is io n o f Screening arrangement for Signals i n R E area as per standard p r a c t i c e . T h e work comprises of providing MS angle frame and wire mesh in order to avoid close proximity of OHE wires. The work also includes provision of earthing wire using 4 S W G G I w i r e s f r o m the screening arrangement up to surface base as per t h e instructions o f Railway representative at site.[All materials required for this work shall be supplied by the Contractor]. | Numbers | 2.00 | 1,880.71 | 3,761.42 |
| 120 | S u p p l y o f C o l o u r l i g h t S i g n a l pole 140mm dia, 4 . 6 m / 3 . 6 m t a l l with necessary inspection a s per s p e c i fi c a t i o n / drawing/ description enclosed in this document. a)Supply of colour light Signal pole 4 . 6 m tall and 140 mm dia(Galvanised) | Numbers | 30.00 | 5,841 | 1,75,230 |
| 121 | S u p p l y o f C o l o u r l i g h t S i g n a l pole 140mm dia, 4 . 6 m / 3 . 6 m t a l l with necessary inspection a s per s p e c i fi c a t i o n / drawing/ description enclosed in this document. b)Supply of colour light Signal pole 3 . 6 m tall and 140 mm dia (Galvanised) | Numbers | 15.00 | 4,737.7 | 71,065.5 |
| 122 | Supply of surface base to suit CLS Signal p o l e 1 4 0 m m d i a w i t h necessary inspection as per specification/ drawing/ description enclosed in this document. | Numbers | 30.00 | 6,814.5 | 2,04,435 |
| 123 | Supply of ladder with platform and shoes to suit CLS pole 4.6m/ 3.6m tall, with necessary i n s p e c t i o n a s per specification/ drawing/ description enclosed i n this document. a)Supply of l a d d e r w i t h p l a t f o r m ( 4 . 6 m ) for CLS(Galvanised) | Numbers | 30.00 | 5,698 | 1,70,940 |
| 124 | Supply of ladder with platform and shoes to suit CLS pole 4.6m/ 3.6m tall, with necessary i n s p e c t i o n a s per specification/ drawing/ description enclosed i n this document. b)Supply of l a d d e r w i t h p l a t f o r m ( 3 . 6 m ) for CLS(Galvanised) | Numbers | 15.00 | 5,494.5 | 82,417.5 |
| 125 | Supply of post type shunt signal - complete with hood etc., with necessary inspection as per specification/ drawing/ description enclosed in this document. | Numbers | 30.00 | 5,087.5 | 1,52,625 |
| 126 | Supply o f Ground type shunt signal - complete with surface base, signal pole, hood etc., with necessary inspection as per specification/ drawing/ description enclosed in this document. | Numbers | 35.00 | 7,463.5 | 2,61,222.5 |
| 127 | Supply of Colour Light Signal Multi Unit type- complete for 4/ 3/ 2 aspect with mounting socket, w i t h necessary inspection as per specification/ drawing/ description enclosed in this document. a)Supply o f colour light Signal unit (4 aspect) | Numbers | 2.00 | 19,470 | 38,940 |
| 128 | Supply of Colour Light Signal Multi Unit type- complete for 4/ 3/ 2 aspect with mounting socket, w i t h necessary inspection as per specification/ drawing/ description enclosed in this document. b)Supply of colour light Signal unit (3 aspect) | Numbers | 25.00 | 16,874 | 4,21,850 |
| 129 | Supply of Colour Light Signal Multi Unit type- complete for 4/ 3/ 2 aspect with mounting socket, w i t h necessary inspection as per specification/ drawing/ description enclosed in this document. c)Supply of colour light Signal unit (2 aspect) | Numbers | 25.00 | 14,278 | 3,56,950 |
| 130 | Supply of Junction type route indicator - 5 unit arm - 1/ 2/ 3/ 4/ 5/ 6 way with mounting sockets, with necessary inspection as per specification/ drawing/ description enclosed in this document. a) Supply of Junction type route indicator - 1 way | Numbers | 11.00 | 15,121.7 | 1,66,338.7 |
| 131 | Supply of Junction type route indicator - 5 unit arm - 1/ 2/ 3/ 4/ 5/ 6 way with mounting sockets, with necessary inspection as per specification/ drawing/ description enclosed in this document. b)Supply of Junction type route indicator - 2 way | Numbers | 6.00 | 18,691.2 | 1,12,147.2 |
| 132 | Supply of Junction type route indicator - 5 unit arm - 1/ 2/ 3/ 4/ 5/ 6 way with mounting sockets, with necessary inspection as per specification/ drawing/ description enclosed in this document. c)Supply of Junction type route indicator - 3 way | Numbers | 1.00 | 22,260.7 | 22,260.7 |
| 133 | Supply of Calling On Signal / 'A' marker light - complete with necessary inspection as per specification/ drawing/ description enclosed in this document. a)Supply of Calling On Signal | Numbers | 20.00 | 3,663 | 73,260 |
| 134 | Supply of Off-set brackets - large/ small made of cast iron with necessary inspection as per specification/ drawing/ description enclosed in this document. a)Supply of Off set bracket - large | Numbers | 40.00 | 3,569.5 | 1,42,780 |
| 135 | Supply of Off-set brackets - large/ small made of cast iron with necessary inspection as per specification/ drawing/ description enclosed in this document. b)Supply of Off set bracket - small | Numbers | 30.00 | 2,645.5 | 79,365 |
| 136 | Supply o f cable termination b o x (FRP type) with necessary inspection a s per s p e c i fi c a t i o n / d r a w i n g / description enclosed in this document. | Numbers | 13.00 | 7,788 | 1,01,244 |
| 137 | Supply of Signal post telephone with facility of paging and talk-back including voice communication equipment with suitable switching arrangement a t the Signal post and a t SM 's r o o m a s per specification enclosed in this document. This includes drawl of tail cable through GI pipe 25mm dia and 2 mtrs long duly clamped to Signal post w i t h b e n d as required at site, termination of tail cable at one end in the apparatus case and other end in the console. In the SM's room, console shall be fixed on a table top. The wiring shall be done using wire PVC 16/0.2mm copper. [Talk-back equipment complete including housing box, wire PVC 16/0.20mm and all other miscellaneous materials required for the w o r k s h a l l b e s u p p l i e d b y the Contractor]. | Numbers | 6.00 | 11,897.35 | 71,384.1 |
| 138 | S u p p l y o f p l u g - i n t y p e , S t y l e QL1, Magnetically Latched Neutral Line 24V DC, 11F/4B contacts Re l a y complete w i t h plug board (base plate), connectors and retaining clips and conforming to BRS 935A and RDSO Spn. N o I R S S 3 4 a n d S - 2 3 o r latest. The interlocking code f o r this unit shall be "ABDEG" | Numbers | 80.00 | 7,076.52 | 5,66,121.6 |
| 139 | Supply of Relay Non - AC immune plug in type Style 'QN1K' DC neutral line, 24V 1000 ohms 6F.6B contacts front contacts metal to carbon & back contacts metal to metal/carbon complete with plug board retaining clip and connectors conforming to BRS:930, IRS:S- 34 & IRS:S-23 and RDSO Spec. STS/E/Relays/UEA(PI) dt. 30.5.97 (Annexure-1) (as applicable). The interlocking code for this unit shall be BDEKX. | Numbers | 10.00 | 4,720 | 47,200 |
| 140 | Supply of Relay, AC Immune, plug-in- type, Style 'QNA1K', DC Neutral line, 24V, 1000 ohms 6F.6B, contacts, front contacts metal to carbon and back contacts metal to carbon, complete with plug board, retaining clip & connectors conforming to BRS:931A, IRS:S60, IRS:S 34, IRS:S 23 & RDSO Spec.No. STS/ E/Relays/UEA (PI) dt.30.05.97 (Annexure-II) (as applicable). The interlocking code for this unit shall be CDEKY. | Numbers | 10.00 | 5,890.8 | 58,908 |
| 141 | Supply of Plug in Type Q-Series Relay QBAT (2F/2B)(Miniature, Tractive armature, AC Immune, D.C Biased Track Relay) A.C. immunity level o f 8 0 Volt A.C, coil nominal resistance o f 9 Ohms, confirming t o BRS spec n o . 9 3 9 A & 966F2 and RDSO specification No. 8 4 / 8 8 o r latest. The interlocking code for this unit shall be "ABEJX" | Numbers | 10.00 | 9,858.79 | 98,587.9 |
| 142 | Supply of KLCR relays 24V, ACI (Supply of Key Lock Checking Relay (KLCR) with one number K-50 neutral Relay to work on 24V DC n o n A C immunized a s per specification No.RDSO/SPN/219/2016 Ver 1.0 with Amdt- 1 or latest (with one extra ward plate and with case) contact configuration-4F/4B and as per IRS:S- 23, IRS:S@58"44@ IRS:46 or latest. | Numbers | 30.00 | 10,722.72 | 3,21,681.6 |
| 143 | Supply of Relay, Non-AC Immune, plug- in type , Style 'QN1',DC neutral line, 24V, 8F.8B contacts front and back contacts metal to carbon with plug board , retaining clip & connectors confirming to BRS:930, IRS:S 34& IRS:S 23 or latest. The interlocking code for this unit shall be ABDEF. | Numbers | 480.00 | 4,366.63 | 20,95,982.4 |
| 144 | Supply of Relay, AC Immune, plug-in- type, Style 'QNA1', DC Neutral line, 24V, 8F.8B contacts, front and back contacts metal to carbon, with plug board, retaining clip and connectors confirming to BRS:931A, IRS:S 60, IRS:S 34 and IRS:S 23 or latest. The interlocking code for this unit shall be ABDGH. | Numbers | 600.00 | 4,639.03 | 27,83,418 |
| 145 | Supply o f Relay rack universal type as per drg.No.S&T/ M F T / 2 9 1 with scaffolding, POWDER C O A T E D with stainless steel nuts and bolts for fixing t h e r a c k s . Supporting angles, frame mounting triangle base with 'J' bolts and insulation o f r e q u i r e d numbers complete t o suit Q N 1 / K-50 p r e wired tag blocks with suitable inner frames. b) 2 way | Numbers | 9.00 | 16,459.48 | 1,48,135.32 |
| 146 | Supply of electronic time delay units (120/60 secs) w i t h p l u g boards, connectors and retaining c l i p s with n e c e s s a r y i n s p e c t i o n as per s p e c i fi c a t i o n / d r a w i n g / description enclosed in this document. | Numbers | 10.00 | 2,742.03 | 27,420.3 |
| 147 | Supply of lamp proving relays(QECX-61) for a)LED aspects w i t h p l u g boards, connectors and retaining clips with necessary inspection as per specification/ | Numbers | 245.00 | 5,901.5 | 14,45,867.5 |
| 148 | Supply of QBCA1 - heavy duty contact relays with necessary inspection a s per specification/ | Numbers | 63.00 | 6,613.75 | 4,16,666.25 |
| 149 | Supply of Computer based Relay Testing Kit suitable for testing all types of Relays | Numbers | 1.00 | 3,54,000 | 3,54,000 |
| 150 | Manufacture a n d supply o f M . S . relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing o f plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Ty p e F5, wiring and termination as per approved c i r c u i t d i a g r a m a n d painting the particulars.[Wire PVC copper, 3/0.75mm and 16/0.2mm c o p p e r , Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6mm brass bolts and nuts, paints, soldering materials, resistors, condensers and all other miscellaneous materials required for the work shall be supplied by the contractor]. a)Wiring of Signal/ point/ LC control circuit (up to 4 relays/Plug in type) | Set | 15.00 | 4,945.51 | 74,182.65 |
| 151 | Manufacture a n d supply o f M . S . relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing o f plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Ty p e F5, wiring and termination as per approved c i r c u i t d i a g r a m a n d painting the particulars.[Wire PVC copper, 3/0.75mm and 16/0.2mm c o p p e r , Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6mm brass bolts and nuts, paints, soldering materials, resistors, condensers and all other miscellaneous materials required for the work shall be supplied by the contractor]. b)Wiring of Signal/ Point/ LC control circuit (up to 8 relays/plug in type) | Set | 13.00 | 8,786.26 | 1,14,221.38 |
| 152 | Manufacture a n d supply o f M . S . relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing o f plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Ty p e F5, wiring and termination as per approved c i r c u i t d i a g r a m a n d painting the particulars.[Wire PVC copper, 3/0.75mm and 16/0.2mm c o p p e r , Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6mm brass bolts and nuts, paints, soldering materials, resistors, condensers and all other miscellaneous materials required for the work shall be supplied by the contractor]. c)Wiring of Signal/ Point/ LC control circuit (up to 12 relays/plug in type) | Set | 3.00 | 11,355.02 | 34,065.06 |
| 153 | Manufacture a n d supply o f M . S . relay frames of suitable size to hold up to 4/ 8/ 12/ 20 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing o f plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Ty p e F5, wiring and termination as per approved c i r c u i t d i a g r a m a n d painting the particulars.[Wire PVC copper, 3/0.75mm and 16/0.2mm c o p p e r , Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6mm brass bolts and nuts, paints, soldering materials, resistors, condensers and all other miscellaneous materials required for the work shall be supplied by the contractor]. d)Wiring of Signal/ Point/ LC control circuit (up to 20 relays/Plug in type) | Set | 6.00 | 13,597.41 | 81,584.46 |
| 154 | Supply of QTA2 - track relays with plug boards, connectors a n d retaining clips with necessary inspection as per specification | Numbers | 73.00 | 4,070 | 2,97,110 |
| 155 | Supply o f QSPA1 type relays with plug boards, connectors a n d retaining clips with necessary i n s p e c t i o n a s per specification/drawing/ | Numbers | 78.00 | 7,139 | 5,56,842 |
| 156 | Supply of relay rack to hold 168 relays, with necessary inspection, a s per specification/drawing | Numbers | 12.00 | 40,700 | 4,88,400 |
| 157 | Supply o f powder coated FTOT o f 500 capacity | Numbers | 5.00 | 50,593.8 | 2,52,969 |
| 158 | Supply o f powder coated FTOT o f 210 capacity | Numbers | 2.00 | 41,627.08 | 83,254.16 |
| 159 | Fabrication and Supply of box suitable for 8 Nos of KLCRs | Numbers | 2.00 | 28,143 | 56,286 |
| 160 | Fabrication and Supply of box suitable for 4 Nos of KLCRs | Numbers | 15.00 | 15,009.6 | 2,25,144 |
| 161 | Erection of Relay Rack 1way/2way/4way with scaffolding suitably concreting tri- pod bases using J-bolts, fixing rack supporting of size 50x50x6mm on to the wall. Reel insulators are t o b e provided f o r insulating the r a c k f r o m the scaffolding & tri-pod bases.(Payment based o n number o f equivalent 1way relay racks) (per Unit = Per 1way Relay Rack) | Per Unit | 12.00 | 596.38 | 7,156.56 |
| 162 | Concreting and e r e c t i o n o f cable termination rack 500/210/140 Terminals capacity on teakwood base frame of size 50mmx150mm of suitable length and width with rectangular slot in the centre for taking in the cables and painting as p e r standard practice.(Supply o f cable termination racks a r e not included in this schedule).[Foundation b o l t s and nuts with washers, cement, sand, stone j e l l y , t e a k w o o d base frame 50mmx150mm of suitable length and breadth, paint, varnish a n d a l l other miscellaneous materials required for the work shall be supplied by the contractor]. a)Concreting and erection of cable termination rack 140/210 capacity | Numbers | 4.00 | 9,752.74 | 39,010.96 |
| 163 | Concreting and e r e c t i o n o f cable termination rack 500/210/140 Terminals capacity on teakwood base frame of size 50mmx150mm of suitable length and width with rectangular slot in the centre for taking in the cables and painting as p e r standard practice.(Supply o f cable termination racks a r e not included in this schedule).[Foundation b o l t s and nuts with washers, cement, sand, stone j e l l y , t e a k w o o d base frame 50mmx150mm of suitable length and breadth, paint, varnish a n d a l l other miscellaneous materials required for the work shall be supplied by the contractor]. b)Concreting and erection of cable termination rack -500 terminal capacity | Numbers | 5.00 | 13,668.26 | 68,341.3 |
| 164 | Fixing o f P B T terminal block/ P B T fuse block, rubber grommets, clamping of cables using teakwood c a b l e clamps and base planks, termination o f cables, provision of ND type fuses o f required capacities, provision o f copper b u s bar for supply terminals, wiring, provision of termination particulars diagram board u s i n g plywood of thickness 1 2 m m - teakwood fi n i s h o f size 1800mm x 1 2 0 0 m m w i t h Aluminium grooved channel frame i n t h e relay room. The blank spaces over the top of the cable termination rack shall b e covered with p h y n o l i c s h e e t o f t h i c k n e s s 3mm wherever required. The termination and cable core particulars shall b e painted o n t h e PVC/ nylon sleeves. T h e work a l s o includes identification of cables using aluminium tags provided on each cable with letters punched neatly. (Supply of PBT terminal blocks 25mm & 60mm centers a n d P B T Fuse blocks is not covered in the schedule) [Wire PVC 3/0.75mm copper, brass bolts and nuts a n d w a s h e r s , f o r fi x i n g PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper b u s b a r s , teakwood 5 0 m m x 50mm for c a b l e clamps, 2 5 m m x 1 0 0 m m f o r base planks, p h y n o l i c s h e e t 6 m m t h i c k o f size 1200mm x 1800mm with aluminium grooved channel frame, phynolic sheet 3 m m thick, paint a n d a l l other m i s c e l l a n e o u s materials shall be supplied by the Contractor]. a)Fixing of PBT terminal blocks (25mm/60mm centre) and termination (Per Unit = Per Terminal Block) | Per Unit | 4400.00 | 167.99 | 7,39,156 |
| 165 | Fixing o f P B T terminal block/ P B T fuse block, rubber grommets, clamping of cables using teakwood c a b l e clamps and base planks, termination o f cables, provision of ND type fuses o f required capacities, provision o f copper b u s bar for supply terminals, wiring, provision of termination particulars diagram board u s i n g plywood of thickness 1 2 m m - teakwood fi n i s h o f size 1800mm x 1 2 0 0 m m w i t h Aluminium grooved channel frame i n t h e relay room. The blank spaces over the top of the cable termination rack shall b e covered with p h y n o l i c s h e e t o f t h i c k n e s s 3mm wherever required. The termination and cable core particulars shall b e painted o n t h e PVC/ nylon sleeves. T h e work a l s o includes identification of cables using aluminium tags provided on each cable with letters punched neatly. (Supply of PBT terminal blocks 25mm & 60mm centers a n d P B T Fuse blocks is not covered in the schedule) [Wire PVC 3/0.75mm copper, brass bolts and nuts a n d w a s h e r s , f o r fi x i n g PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper b u s b a r s , teakwood 5 0 m m x 50mm for c a b l e clamps, 2 5 m m x 1 0 0 m m f o r base planks, p h y n o l i c s h e e t 6 m m t h i c k o f size 1200mm x 1800mm with aluminium grooved channel frame, phynolic sheet 3 m m thick, paint a n d a l l other m i s c e l l a n e o u s materials shall be supplied by the Contractor]. b)Termination using P B T fuse block in cable termination rack (Per Unit = Per Fuse Block) | Per Unit | 350.00 | 201.27 | 70,444.5 |
| 166 | Concreting and erection of Relay racks- 168/56 relay capacity using 'J' type bolts a n d painting o f relay rac k a s p e r the instructions of Railway representative at site.(Supply o f r e l a y r a c k i s not covered i n this schedule).['J' type bolts and nuts with washers, nylon bushes, concreting materials, paint and all other miscellaneous materials required for the w o r k s h a l l b e s u p p l i e d b y the Contractor]. a)Concreting and erection of relay rack - 168 capacity | Numbers | 14.00 | 6,818.18 | 95,454.52 |
| 167 | Fixing o f plug boards, 5 0 w a y terminal blocks with 2BA terminals, and wiring of r e l a y s a s p e r t h e a p p r o v e d circuit diagram using w i r e P V C 16/0.2mm copper. Suitable wire supporting tray with cover made of PVC shall be provided horizontally a n d vertically in the relay racks.. While running the wires on the aluminium ladder proper care shall be taken t o p r o v i d e smooth materials like rubber beading in the openings on Phynolic sheets, to avoid damage to wires. The work also includes w i r i n g o f contacts f o r data l o g g e r a n d terminating t h e m i n tag blocks, provision of relay index board. ( S u p p l y o f r e l a y s , p l u g boards, connectors and retaining c l i p s i s not covered i n this schedule). [Wire PVC 1 6 / 0 . 2 m m c o p p e r , t a g blocks, 2BA terminals, h a r d w o o d p l a n k o f size 600mmx 900mmx25mm w ith decolum fi n i s h , M S a n g l e s o f size 25mmX25mmX6mm, relay fixing bolts and nuts, teakwood plank 25mm thick for fixing resistors a n d condensers, p h y n o l i c sheet 6mm t h i c k o f size 1 2 0 0 m m X 1 8 0 0 m m with aluminium grooved channel frame f o r relay index b o a r d , p a i n t s , s o l d e r i n g materials, b u n c h i n g t h r e a d , w i r e wound resistance, condenser, w ire supporting tray with cover of suitable size made of PVC, paint, varnish and a l l other miscellaneous materials required for t h e w o r k s h a l l b e supplied by the Contractor]. | Per Relay | 25.00 | 1,045.76 | 26,144 |
| 168 | Fi x i n g o f additional p l u g boards, 50 ways terminal b l o c k s a n d w i r i n g of additional relays a s p e r t h e approved c i r c u i t diagram using wire PVC 16/0.2mm copper. Additional wire supporting tray with cover made of PVC s h a l l b e provided wherever required. Alterations to Relay particulars shall be incorporated in the relay Index board. ( S u p p l y o f r e l a y s , p l u g boards, connectors and retaining clips a n d 50 w a y terminal boards i s n o t covered in t h i s schedule).[Wire PVC 16/0.2mm copper, 2 BA terminals, teakwood plank 2 5 m m t h i c k for fixing resistors and c o n d e n s e r s , soldering materials, b u n c h i n g t h r e a d , w i r e wound resistance, condenser, w ire supporting tray with cover of suitable size made of PVC, paint, v a r n i s h a n d a l l other miscellaneousmaterials required for the work shall be supplied by the Contractor ] | Per Relay | 50.00 | 726.5 | 36,325 |
| 169 | Carrying out alterations t o t h e existing relays in the relay racks/apparatus cases as per the approved circuit diagram using wire PVC 16/0.2mm c o p p e r. T h e w o r k includes painting alterations and releasing the unwanted wires carefully without disturbing the existing wiring.[Wire P V C 16/0.2mm copper, soldering materials, bunching threads, condensers, resistances and teakwood plank for fixing them and all other miscellaneous materials required f o r t h e w ork shall b e supplied by the Contractor]. | Per Relay | 75.00 | 695.67 | 52,175.25 |
| 170 | Provision o f Interconnections between relay racks, cable termination racks, SM's control panel, battery room, power room, termination and wiring. The work involves laying of underground cables in the duct as well as with clamping arrangements o n the walls, supply and fixing of aluminium ladders and supports with 3mm thick phynolic sheet for running the cables in the relay room. Interconnection shall be carried out with signaling m u l t i c o r e c a b l e (skinned/ unskinned) and power cables as per the instructions of Railway representative at site. The w o r k a l s o include t e r m i n a t i o n o f the interconnection cables on 50 way terminals in the relay rack/ control panel, cable termination r a c k e t c . A f t e r the interconnection cables are laid, the ducts shall b e filled w i t h M s a n d a n d closed. Wherever required the cables shall be taken to other floors in the building b y clamping them on MS angles and flats grouted on the walls.(Supply o f interconnection cables is not included in this schedule). [ 2 B A t e r m i n a l s , A l u m i n i u m ladder a r r a n g e m e n t s using 37mmx37mmx5mm aluminium angles a n d 25mmx6mm aluminium flats, aluminium supports, phynolic s h e e t - 3 m m t h i c k f o r b o t t o m of aluminium ladders, M S angles and flats, bolts and nuts, concreting materials, and all other materials required for the work shall be supplied by the contractor]. b)Provision o f interconnection - more than 5 roads (same floor) | Lumpsum | 1.00 | 1,47,833.5 | 1,47,833.5 |
| 171 | Provision o f Interconnections between relay racks, cable termination racks, SM's control panel, battery room, power room, termination and wiring. The work involves laying of underground cables in the duct as well as with clamping arrangements o n the walls, supply and fixing of aluminium ladders and supports with 3mm thick phynolic sheet for running the cables in the relay room. Interconnection shall be carried out with signaling m u l t i c o r e c a b l e (skinned/ unskinned) and power cables as per the instructions of Railway representative at site. The w o r k a l s o include t e r m i n a t i o n o f the interconnection cables on 50 way terminals in the relay rack/ control panel, cable termination r a c k e t c . A f t e r the interconnection cables are laid, the ducts shall b e filled w i t h M s a n d a n d closed. Wherever required the cables shall be taken to other floors in the building b y clamping them on MS angles and flats grouted on the walls.(Supply o f interconnection cables is not included in this schedule). [ 2 B A t e r m i n a l s , A l u m i n i u m ladder a r r a n g e m e n t s using 37mmx37mmx5mm aluminium angles a n d 25mmx6mm aluminium flats, aluminium supports, phynolic s h e e t - 3 m m t h i c k f o r b o t t o m of aluminium ladders, M S angles and flats, bolts and nuts, concreting materials, and all other materials required for the work shall be supplied by the contractor]. c)Provision o f interconnections -more than 5 roads (different floors) | Lumpsum | 1.00 | 1,75,746.3 | 1,75,746.3 |
| 172 | S u p p l y o f a s p i r a t i o n t y p e smoke detector. Highly sensitive smoke aspiration system for Monitoring of r o o m s a n d equipment's for earliest possible fire detection For Relay rooms a s p e r R D S O spec No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 5.00 | 7,08,081.12 | 35,40,405.6 |
| 173 | S u p p l y o f s i n g l e L o o p Analog addressable Fire A l a r m s y s t e m with loo p capacity of connecting maximum 50 devices. The panel shall have a built i n power supply and battery charger R D S O Spec. No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 5.00 | 3,11,682.08 | 15,58,410.4 |
| 174 | Supply of Multi Sensor detector Dual Optical/ Thermal a s p e r RDSO specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 90.00 | 16,042.23 | 14,43,800.7 |
| 175 | S u p p l y o f Addressable S i n g l e action indoor manual call point with back box (RED) as per RDSO specification No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 5.00 | 9,494.38 | 47,471.9 |
| 176 | Supply of Sounder having range of 81 dbA to 92 d b A a s p e r RDSO specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 5.00 | 11,420.51 | 57,102.55 |
| 177 | S u p p l y o f I n t e l l i g e n t addressable Monitor module a s p e r RDSO specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 20.00 | 9,494.38 | 1,89,887.6 |
| 178 | Supply of Intelligent addressable control m o d u l e a s p e r R D S O specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 1.00 | 9,494.38 | 9,494.38 |
| 179 | Supply o f Auto-dialer f o r S M S alarm generation & routing in case of Fire Alarm to concerned perso ns a s per RDSO No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 5.00 | 43,931.48 | 2,19,657.4 |
| 180 | Supply of 2core 1.5sq.mm FRLS Copper unarmoured cable a s per RDSO specifications No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Metre | 1200.00 | 296.94 | 3,56,328 |
| 181 | S u p p l y o f L H S C a b l e R D S O Spec. No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Metre | 250.00 | 2,246.07 | 5,61,517.5 |
| 182 | Supply of L H S control module. RDSO Spec. No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 5.00 | 1,55,660.6 | 7,78,303 |
| 183 | Supply and Installation of Air sampling CPVC Pipes with all required accessories for Aspiration system) | Set | 5.00 | 76,137.76 | 3,80,688.8 |
| 184 | S u p p l y o f B I S l i s t e d Semi-automatic Stainless Steel preventive device with UL approved c l e a n g a s w i t h Auto manual Reverse Stainless Steel valve ' N A S A 400 MAR' or similar having capacity of 4kg, and made o f stainless s t e e l 3 0 4 g r a d e with Indian Railway logo put on each unit. | Per Unit | 10.00 | 35,219.46 | 3,52,194.6 |
| 185 | Supply O f movable tender a t doorstep with UL approved having capacity of 10kgs made of SS 304 grade with Indian Railway logo put on each unit and clean gas shelf life with 10 years warranty for leakage. Note: Warranty of OEM and Test certificates of a n y NABL approval L A B f o r clean gas along with the offer. | Per Unit | 2.00 | 1,03,181.84 | 2,06,363.68 |
| 186 | Supply o f Relay Module a s p e r RDSO specification No.RDSO/SPN/217/2021 Ver.3.0 or latest. | Numbers | 5.00 | 9,867.99 | 49,339.95 |
| 187 | Supply of TCIP Module /Networking card for interfacing t h e F i r e A l a r m and Detection systems | Numbers | 5.00 | 30,881.44 | 1,54,407.2 |
| 188 | Supply, installation, configuring, testing and commissioning o f remote monitoring software along with license f o r 9 9 control panels a s per No.RDSO/SPN/217/2021 Ver.3.0 or latest.. This includes necessary gateway card and network interface card for the system fully functional a s desired by railways. (software suitable for 8 stations) | Lumpsum | 5.00 | 5,21,517.86 | 26,07,589.3 |
| 189 | Installation, testing a n d commissioning charges o f fi r e alarm system including programming of devices and fire alarm panel | Set | 1.00 | 95,933.57 | 95,933.57 |
| 190 | Supervision, programming,testing & Commissioning o f Aspiration smoke detection | Set | 1.00 | 83,751.53 | 83,751.53 |
| 191 | Supply of Handheld True RMS Multi Meter, as per Technical specification | Numbers | 5.00 | 23,192.34 | 1,15,961.7 |
| 192 | Supply of Handheld True RMS clamp Meter, as per Technical specification | Numbers | 5.00 | 33,510.29 | 1,67,551.45 |
| 193 | Supply o f O T D R (mini) w i t h standard accessories f o r 1310/1550nm w i t h all standard accessories as per TEC specification GR/OTD-02/02 Jan 2005 or latest, ( this item should have valid TEC approval certificate) as per Technical specification | Numbers | 1.00 | 3,07,856.22 | 3,07,856.22 |
| 194 | S u p p l y o f D i g i t a l I n s u l a t i o n tester (Megger) 50V-500V/1000 mega ohm battery operated with a l l complete accessories, a s per Technical specification | Numbers | 2.00 | 11,844.52 | 23,689.04 |
| 195 | Supply o f Cable Route Tracer a s per Technical specification | Numbers | 2.00 | 5,78,788.99 | 11,57,577.98 |
| 196 | Supply of Portable Cable Fault Locator as per Technical specification | Numbers | 1.00 | 1,86,694.53 | 1,86,694.53 |
| 197 | Supply of Digital Earth clamp Tester as per Technical specification | Numbers | 1.00 | 71,129.79 | 71,129.79 |
| 198 | Supply o f Hand Held Thermometer, as per Technical specification | Numbers | 1.00 | 8,437 | 8,437 |
| 199 | Supply o f O F C P o w e r Meters, a s per Technical specification | Numbers | 1.00 | 47,200 | 47,200 |
| 200 | Supply of Laser source and Power meter w i t h accessories a s p e r Technical specification | Numbers | 1.00 | 40,710 | 40,710 |
| 201 | Supply o f Rodometer a s p e r Technical specification | Numbers | 1.00 | 4,252.24 | 4,252.24 |
| 202 | S u p p l y o f B a t t e r y Te s t e r a s per Technical specification | Numbers | 5.00 | 715.95 | 3,579.75 |
| 203 | Supply of Hydrometer | Numbers | 10.00 | 228.94 | 2,289.4 |
| 204 | Supply of Double walled corrugated pipe - 103.5mm inner dia & 120mm outer dia conforming t o specification N o . IS 14930(Part 2 ) : 2 0 0 1 w ith o n e coupler for every 6 m o f pipe a s p e r Technical specification | Metre | 2000.00 | 365.19 | 7,30,380 |
| 205 | Supply of GI pipes - 50mm dia -3.65mm thick as per Technical specification | Metre | 250.00 | 457.88 | 1,14,470 |
| 206 | Supply of GI pipes - 100mm dia-4.5mm thick as per Technical specification | Metre | 1500.00 | 1,119.16 | 16,78,740 |
| 207 | S u p p l y o f High-Density Polyethylene Pipes (HDPE) of 110 mm Outer Dia, 10 mm Wall Thickness, along with one coupler for every 6 M e t e r s a s per specification N o . I S 4984: 2016 with l a t e s t a m e n d m e n t s a n d Material Grade:PE 80 | Metre | 1250.00 | 853.55 | 10,66,937.5 |
| 208 | Supply and laying of PVC Warning Tape colour Orange, width of 250mm (10") by p r i n t i n g w i t h b l a c k l e t t e r s 'Indian RailwaySignal/Telecom/OFC Cable' on both sides | Metre | 5000.00 | 46.15 | 2,30,750 |
| 209 | Supply of Electronic Cable Route Marker 3M make or similar, Model: RFID (1421) and installation, c a b l e d e t e c t io n of capacity to detect the cable upto 5 feet depth. | Numbers | 250.00 | 2,441.72 | 6,10,430 |
| 210 | S u p p l y o f H D P E P i p e 4 0 m m (outer dia)/33 mm (inner dia) with couplers | Metre 45000.00 | — | 60.93 | 27,41,850 |
| 211 | S u p p l y a n d Installation o f Wall/Rack m o u n t a b l e 2 4 F i b r e management system (FMS) c o n f o r m i n g to RDSO/SPN/TC- 37/2000(rev-3 amdt-1 or latest similar to COMMSCOPE m ak e or better, suitable for splicing and front patching 24F cable with all accessories and terminating the optical fibre cable with splicing and front patching in FMS in the Location Box. This includes Supply and Provision of 4 nos of Patch cords of required length ( A l l other materials required for splicing are to be supplied by contractor ) | Numbers | 2.00 | 18,686.74 | 37,373.48 |
| 212 | S u p p l y a n d Installation o f Wall/Rack m o u n t a b l e 4 8 F i b r e management system (FMS) c o n f o r m i n g to RDSO/SPN/TC- 37/2000(rev-3 amdt-1 or latest similar to COMMSCOPE m ak e or better, suitable for splicing and front patching 48F cable with all accessories and terminating the optical fibre cable with splicing and front patching in FMS in the Location Box. This includes Supply and Provision of Wooden Plank, L clamps and 4 nos o f Patch cords of required l e n g t h (All other materials required for splicing are to be supplied by contractor) | Numbers | 25.00 | 32,885.01 | 8,22,125.25 |
| 213 | Supply and Installation of 19", 6U rack of size 600mm x 600mm w i t h complete accessories | Numbers | 4.00 | 4,936.26 | 19,745.04 |
| 214 | Supply a n d Installation o f surface Wall mountable type 1 9 i n c h 1 2 U network Rack with front glass door with lock and rack fixing multipoint AC Power trip & all accessories (Power extension board with one set of MCB, exhaust fan, cable manager) | Numbers | 6.00 | 6,761.51 | 40,569.06 |
| 215 | Supply and Installation of covered 19inch Racks of size 1950mm x600mm x 600mm or higher (Make: HCL/ Vero/President/ Rittal/ Puncom or better) complete with all fittings including DC Fans (24V/48V)-2nos, separator sheet/ plate to keep testing equipment-1no and AC power distribution panel ( Horizontal fitting) with power sockets and fuse protection ( min 6 nos of 230V - 15/5A combined and other accessories | Numbers | 1.00 | 65,734.12 | 65,734.12 |
| 216 | Supply of nylon Insulations for IRS point machine | Set | 20.00 | 1,671.75 | 33,435 |
| 217 | Supply of track lead junction box - FRP type with 4 terminals and stumps with necessary inspection a s per s p e c i fi c a t i o n / drawing/ description enclosed in this document. | Numbers | 272.00 | 1,622.5 | 4,41,320 |
| 218 | Supply of Track Feed Resistance | Numbers | 92.00 | 287.77 | 26,474.84 |
| 219 | Supply of Bond Pins (pack of 100) | Numbers | 2.00 | 191.85 | 383.7 |
| 220 | Supply of gauge Tie Plate Insulation | Set | 90.00 | 210.72 | 18,964.8 |
| 221 | Supply o f P B T terminals 25mm/ 60mm c e n t r e a n d P B T F u s e b l o c k s with necessary inspection a s per s p e c i fi c a t i o n / drawing/ description enclosed in this document. a)Supply of PBT terminals 25mm centre. | Numbers | 8500.00 | 61.44 | 5,22,240 |
| 222 | Supply o f P B T terminals 25mm/ 60mm c e n t r e a n d P B T F u s e b l o c k s with necessary inspection a s per s p e c i fi c a t i o n / drawing/ description enclosed in this document. b)Supply of PBT terminals 60mm centre. | Numbers | 2000.00 | 93.02 | 1,86,040 |
| 223 | Supply o f P B T terminals 25mm/ 60mm c e n t r e a n d P B T F u s e b l o c k s with necessary inspection a s per s p e c i fi c a t i o n / drawing/ description enclosed in this document. c)Supply of PBT fuse block without ND fuse | Numbers | 450.00 | 103.84 | 46,728 |
| 224 | Supply of apparatus cases (full/ half/ quarter size) to suit Southern Railway standard with necessary inspection as p e r specification/ drawing/ description enclosed i n this document a)Supply of apparatus case - Full size | Numbers | 42.00 | 18,821 | 7,90,482 |
| 225 | Supply of apparatus cases (full/ half/ quarter size) to suit Southern Railway standard with necessary inspection as p e r specification/ drawing/ description enclosed i n this document b)Supply of apparatus case - Half size | Numbers | 20.00 | 15,576 | 3,11,520 |
| 226 | Supply a n d installation o f yard layout diagram board in the station master's room. The b o a r d s h a l l b e m a d e of Phynolic synthetic industrial fibre base fi n e weave cotton fi b r e b o a r d (matt fi n i s h ) 6 m m thick size 1 8 0 0 m m X 1 2 0 0 m m w i t h aluminium channel frame. The yard layout shall be neatly painte d a n d fi x e d a s instructed by Railway representative at site.[All materials required for the work shall be supplied by the Contractor]. | Numbers | 1.00 | 16,722.15 | 16,722.15 |
| 227 | Manufacture and supply of teak wood tool box of size 1000X750X100mm made of 25mm thick teak wood persplex sheet fronted 6mm (Colourless) fixed on the wall at a convenient location as instructed by Railway representative at site. The board should have provision of pad lock and locking arrangements and shall be equipped with the following tools[reputed make]: a. Digital Mulltimeter similar to Model No. Rish Multi 18S with suitable carrying case and test probes. b. Centre zero ammeter 30-0-30 Amps - 1 No. c. Screw drivers of different types and sizes with common handle - 1 set d. Spanner double ended 33mm - 1 No. e. Spanners double ended 3/8x1/2" - 1 No. f. Spanners double ended 5/8x3/4" - 1 No. g . Spanners double ended 7/8x1" - 1 No. h. Hammer 1 1/2 lbs ball pane - 1 No. i. Hacksaw frame - 1 No. j. Adjustable screw spanner 12" - 1 No. k. Insulated cutting pliers- 1 No. l. Insulated nose plier- 1 No. m. Electric soldering iron 230V 60W Soldron/Philips make - 1 No. n. Electric soldering iron 110V 35W Soldron/Philips make - 1 No. o . Megger 500V/ 500Mohms. with Probe- 1 No. The above tools shall be purchased from Reputed manufacturers only in consultation with the Railway representative at site.[Teak w oo d tool b o x made o f 2 5 m m teak wood plank, perspex sheet, all t h e tools mentioned above, padlock and other miscellaneous items shall be supplied by the Contractor]. | Set | 5.00 | 29,185.6 | 1,45,928 |
| 228 | Supply o f magneto telephone handle type and supply o f Ni-cad power pack 4V-2.2AH with charger to work on 110VAC | Numbers | 15.00 | 8,106.7 | 1,21,600.5 |
| 229 | S u p p l y a n d installation o f teakwood glass fronted b o x o f s i z e 3 0 0 m m x 600mm x 75mm with hooks to keep various keys with description engraved on the tags. [TW Glass fronted box of size 300mmx600mmx 75mm with built in lock, hooks, engraved tags and all other miscellaneous materials required for the work shall b e supplied b y the Contractor]. | Numbers | 2.00 | 7,505.45 | 15,010.9 |
| 230 | Supply of 3/0.75mm or 4 Sq.mm Copper cable(per unit=100 mtrs) APC) | Per Unit | 50.00 | 3,459.5 | 1,72,975 |
| 231 | Supply of ND Fuse of various capacities (Per unit=Per fuse) | Per Unit | 300.00 | 37.74 | 11,322 |
| 232 | "Supply and provision of Rubber mat of not less than 6mm thick and with an insulation to withstand 650VAC, o n the fl o o r o f relay room e t c a t places as indicated b y railway representative at site." | Square Foot | 500.00 | 144.86 | 72,430 |
| 233 | Supply of External Solid-state Drive (SSD) of 1TB capacity. | Numbers | 1.00 | 15,498.45 | 15,498.45 |
| 234 | Excavation o f p i t , erection o f cable termination boxes on rails and concreting as per Drg. No.SG/CN/02/8, drilling of suitable holes in the box, fixing of 2 Nos. of GI pipes 32mm dia a n d 300mm l o n g a t t h e bottom with clamp nuts - 12 mm thick, one at the inner side and another at the outer side for each pipe for cable entry and one GI pipe 150mm long 32mm dia for drawl of jumper wires for Point machines etc., fixing of hardwood plank 37mm thick on the bottom, provision of one EWS lock, and painting the boxes i n s i d e and outside with one coat of red-oxide and two coats of aluminium paints. | Numbers | 13.00 | 5,029.69 | 65,385.97 |
| 235 | Installation of combined type point machine-IRS t y p e a n d connecting all ground connections including wiring and termination in point machine and interconnections between point machine and CT box through PVC hose p i p e w i t h 3/0.75mm and 7/1.40mm copper w i r e a n d painting. This work i n c l u d e s p r o v i s i o n o f insulatio n to stretcher bars, throw b a r l u g a n d "D" bracket wherever required, cutting of notches on the point machines covers to suit crank handle configuration. (Combined type point machine with ground connection, uninsulated stretcher bar, throw bar lug and 'D' brackets will be supplied by Railways. [All types of insulations connected to point work, coal bengal, all type of bolts and nuts, washers spring/flat wire PVC 7/1.4mm copper, PVC hope pipe, paints, PVC/nylon sleeves and all other miscellaneous materials required for t h e w o r k s h a l l b e supplied by the Contractor]. | Numbers | 36.00 | 16,383.88 | 5,89,819.68 |
| 236 | Installation of Signal post telephone (paging and talk back) | Numbers | 6.00 | 5,392.75 | 32,356.5 |
| 237 | Fixing and wiring of platform repeaters. The work involves fi x i n g o f platform repeater using suitable fixing arrangements at places indicated, wiring the same and painting as per the instructions of Railway representative at site. T h e signal shall be connected to the apparatus case using cables neatly c l a m p e d . T h e w o r k also includes provision of one EWS lock. (Laying of cable is not included in the scope of this work.) (Supply of repeater signals and cables is not included in this schedule). [Wire PVC 3/0.75mm copper, paint, EWS l o c k a n d a l l o t h e r miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 3.00 | 6,063.56 | 18,190.68 |
| 238 | F i l l i n g e a r t h a r o u n d location boxes/signal foundations for a width of 0.5m on all sides, up to a level 150mm b e l o w t h e foundation top. T h i s work i n c l u d e s consolidation of earth by watering and ramming.The earth shall b e t a k e n from Railway premises as instructed by Railway representative at site. | cum | 210.00 | 231.3 | 48,573 |
| 239 | E x c a v a t i o n o f p i t , c a s t i n g concrete foundation as per Drg.No.SG/CN/02/9 using metallic templates, for erection of colour light signals up to 4 aspects. [Foundation b o l t s , c e m e n t , M sand, stone jelly of size 20/25mm dia and all other miscellaneous materials required f o r the work shall be supplied by the Contractor]. | Numbers | 30.00 | 9,213.28 | 2,76,398.4 |
| 240 | "Erection o f surface base, signal pole, mounting o f colour light signal u p t o 4 aspects complete on Signal pole/ Off-set bracket, (for LED/ filament bulbs) with lenses, triple pole lamp holder, filament s w i t c h i n g u n i t s , C L S transformer, current regulators (whichever is applicable), fixing of ladder with platform complete and concreting of ladder shoe, fixing o f number plates, m a r k e r b o a r d , l e n s g u a r d , fi x i n g of speed limit board wherever necessary, termination o f t a i l cable s, w i r i n g of signal unit w i t h P V C w i r e 3/0.75mm copper, provision of EWS locks, and painting of one coat o f r e d oxide and two coats of aluminium/ enamel paints. When the aspect is fixed on Offset bracket using 'U' bolts and nuts, a through bolt shall be provided by drilling a hole in the signal pole t o prevent the offset bracket from sliding down. (Supply of surface base, Offset bracket, CLS pole, CLS aspects complete, ladder with shoes and platform, Speed limit board, LED aspects, current regulators, lamp holders, lamps, filament switching unit and CLS transformer is not covered in this schedule).['U' bolts and nuts, through bolts and nuts, cement, stone jelly 20/25mm dia, M sand, Signal Collar Rings, wire PVC 3/0.75mm copper, lens- guard, all fixing bolts and nuts, lead w o o l , p a i n t s P V C / N y l o n sleeves, enameled n u m b e r p l a t e s . enameled marker boards, EWS locks, and all other miscellaneous materials for the work shall be supplied by the Contractor]." | Numbers | 120.00 | 8,287.08 | 9,94,449.6 |
| 241 | "Excavation of pit and casting concrete foundation a s per Drg, No.SG/CN/02/10 using metallic templates, for erection of ground type colour light shunt signal. [Foundation bolts and nuts, cement, M sand, stone jelly o f size 20/25mm and all other miscellaneous materials for the work shall be supplied by the Contractor]." | Numbers | 35.00 | 4,645.17 | 1,62,580.95 |
| 242 | "Erection o f Ground type shunt signal complete including surface base, signal pole, LED aspects/ lenses, bulbs with holders (whichever is applicable), fixing o f lens guards, n u m b e r plate, termination o f tail cables, w i r i n g of signal u n i t w i t h P V C wire 3/0.75mm copper, provision o f E W S locks and painting o f o n e coat o f r e d oxide and two coats o f Aluminium/ enamel paint. (Supply o f Ground t y p e s h u n t signal complete including surface base, signal pole, LED aspects, holder, bulbs, and lenses is not covered i n this schedule). [ W i r e PVC 3/0.75mm c o p p e r , lens guards, E W S locks, Enameled number plates, bolts and nuts, lead wool, paints and all other miscellaneous materials shall be supplied by the Contractor]." | Numbers | 35.00 | 3,170.44 | 1,10,965.4 |
| 243 | Fixing of Offset brackets using 'U' bolts and nuts, erection o f Post type shunt Signals, termination o f tail cables and w i r i n g using wire P V C 3/0.75mm c o p p e r , provision of EWS l o c k and painting o f o n e coat o f red-"oxide and two coats of aluminium/ enameled paint. The work also includes drilling suitable holes o n t h e C L S p o s t and provision o f a through bolt with nut to prevent the Off-setbracket from slipping down." | Numbers | 50.00 | 2,306.03 | 1,15,301.5 |
| 244 | Fixing of junction type route indicators - 1 way t o 6 ways - complete/ fixing of additional l i m b t o t h e existing route indicators, termination o f t a i l cables, wiring as per approved circuits diagram using wire PVC 3/0.75mm copper, provision of required No of EWS locks, wire mesh, and painting.(Supply of junction t y p e R o u t e Indicators - complete and additional limb is not covered in t h i s schedule).[3/0.75mm wire PVC, fixing bolts and nuts, EWS locks, w i r e m e s h , PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor]. a)Fixing a n d w i r i n g of direction type route indicator - 1 way | Numbers | 10.00 | 2,238.04 | 22,380.4 |
| 245 | Fixing of junction type route indicators - 1 way t o 6 ways - complete/ fixing of additional l i m b t o t h e existing route indicators, termination o f t a i l cables, wiring as per approved circuits diagram using wire PVC 3/0.75mm copper, provision of required No of EWS locks, wire mesh, and painting.(Supply of junction t y p e R o u t e Indicators - complete and additional limb is not covered in t h i s schedule).[3/0.75mm wire PVC, fixing bolts and nuts, EWS locks, w i r e m e s h , PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor].b)Fixing a n d w i r i n g of direction type route indicator - 2 way | Numbers | 5.00 | 2,460.04 | 12,300.2 |
| 246 | Fixing of junction type route indicators - 1 way t o 6 ways - complete/ fixing of additional l i m b t o t h e existing route indicators, termination o f t a i l cables, wiring as per approved circuits diagram using wire PVC 3/0.75mm copper, provision of required No of EWS locks, wire mesh, and painting.(Supply of junction t y p e R o u t e Indicators - complete and additional limb is not covered in t h i s schedule).[3/0.75mm wire PVC, fixing bolts and nuts, EWS locks, w i r e m e s h , PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor].c)Fixing a n d w i r i n g of direction type route indicator - 3 way | Numbers | 1.00 | 2,679.26 | 2,679.26 |
| 247 | Fixing of Offset brackets using 'U' bolts and nuts, erection of Calling On Signals/ 'A' marker lights, termination of tail cables and wiring u s i n g w i r e PVC 3/0.75mm copper, provision o f EWS lock, number plates/ marker boards and painting. The work also includes drilling suitable h o l e s o n t h e CLS post and provision of a through bolt with nut to prevent the Off-set bracket from slipping down.(Supply o f C a l l i n g on S i g n a l / ' A ' marker light, LED aspects/holders & b u l b s a n d Off set brackets is not covered in this schedule).['U' bolts a n d nuts, through b o l t s w i t h nut, wire P V C 3/0.75mm copper, E W S lock, Enameled number plates, w ire mesh, PVC/Nylon sleeves, p a i n t s a n d a l l other miscellaneous materials shall be supplied by the contractor]. | Numbers | 20.00 | 2,081.25 | 41,625 |
| 248 | Releasing o f existing t a i l c a b l e s and drawl of new tail cables for colour light signals up to f o u r aspec ts w i t h or without route indicator, post type shunt signal and Calling on signals, termination o f n e w t a i l cables and w i r i n g u s i n g w i r e P V C 3/0.75mm copper. This work includes drawl of new tail cables into the signal post duly releasing the existing tail cables from the relevant signals and re-surfacing t h e earth excavated as instructed by Railway representative at site. [Wire PVC 3/0.75mm copper, paints and all other miscellaneous materials shall be supplied by the Contractor]. | Per Unit | 5.00 | 1,524.86 | 7,624.3 |
| 249 | "Removal of existing CLS units, fixing of new CLS units with LED aspects/ lamps, holders etc., up to four aspects, directly or using off set brackets duly drilling holes on the signal poles, provision of E W S l o c k s wherever necessary, termination o f t a i l cables and wiring using wire PVC3/0.75mm copper and painting of aspect. The new tail cables shall be taken through the signal poles and the unwanted cables duly released" | Numbers | 5.00 | 10,296.64 | 51,483.2 |
| 250 | Excavation o f p i t a n d construction of masonry platform a s p e r drawing No. SG/CN/02/12 with country bricks o f size 220mmx 100mmx60mm (app) a t the foot of signal post telephones as per the instructions of Railway representative at site.[Country bricks of size 220mmx100mmx60mm (app), cement, M sand a n d a l l o t h e r miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 5.00 | 5,355.94 | 26,779.7 |
| 251 | Hot dip Galvanization of signal post and ladder (4.6m tall, 140 mm dia /3.60 m tall,140 mm dia), clamps, point roddings and other m a t e r i a l s r e l a t e d to Signalling. Minimum DF thickness shall be 80 microns. Transportation of m a t e r i a l s f r o m site/stores to galvanization workshop a n d b a c k to s i t e / s t o r e s n o t i n c l u d e d i n this schedule.Transportation charges will be a s per "relevant S O R schedules. Test certificate showing t h e D F T , t y p e of galvanization, materials used etc., from galvanizing firm for each batch to be submitted.(Unit i s calculated based on the weight of the Signal poles, ladders, clamps, rodding's etc.,)" | Kg | 500.00 | 25.31 | 12,655 |
| 252 | Provision of DC Single/ Double rail track circuit to suit RE/ Non-RE areas as per approved signaling plan using Plug-in type track relays. This work includes provision of double bonding, and parallel jumpers, provision of bond wire clips, provision of track lead connections using 2c X 2.5 sq.mm cable, provision of TLD boxes 2 Nos. at Relay end, 2 Nos. at Feed end and 2 No's for parallel jumpers as necessary to suit layouts, for each Track Circuit, and termination of jumpers and tail cables in track lead junction boxes, installation of relays, track feed battery chargers to charge up to 4 cells, track feed resistance, 'B' type choke' and secondary cells - 80 AH capacity in apparatus cases and wiring with wire PVC 3/0.75mm copper. The work also includes painting of track Circuit No. with Feed end/ Relay end details on the TLD boxes. The work also includes provision of insulations for gauge tie plates and nose crossing plates wherever required. (Provision of rail joint insulation is not covered in this schedule.)(Uninsulated gauge type plate and nose crossing plate will be supplied by Railways. Supply of track feed battery charger, 'B' type choke, track relays, un-charged secondary cells (2V - 80AH), TLD boxes with stumps,2cX2.5 sq.mm cable, is not covered in this schedule). a)Provision of track circuit in RE/Non RE area (point zone) | Numbers | 48.00 | 8,914.5 | 4,27,896 |
| 253 | Provision of DC Single/ Double rail track circuit to suit RE/ Non-RE areas as per approved signaling plan using Plug-in type track relays. This work includes provision of double bonding, and parallel jumpers, provision of bond wire clips, provision of track lead connections using 2c X 2.5 sq.mm cable, provision of TLD boxes 2 Nos. at Relay end, 2 Nos. at Feed end and 2 No's for parallel jumpers as necessary to suit layouts, for each Track Circuit, and termination of jumpers and tail cables in track lead junction boxes, installation of relays, track feed battery chargers to charge up to 4 cells, track feed resistance, 'B' type choke' and secondary cells - 80 AH capacity in apparatus cases and wiring with wire PVC 3/0.75mm copper. The work also includes painting of track Circuit No. with Feed end/ Relay end details on the TLD boxes. The work also includes provision of insulations for gauge tie plates and nose crossing plates wherever required. (Provision of rail joint insulation is not covered in this schedule.)(Uninsulated gauge type plate and nose crossing plate will be supplied by Railways. Supply of track feed battery charger, 'B' type choke, track relays, un-charged secondary cells (2V - 80AH), TLD boxes with stumps,2cX2.5 sq.mm cable, is not covered in this schedule). b)Provision of track circuit in RE/Non RE area (other than point zone) | Numbers | 23.00 | 7,145.44 | 1,64,345.12 |
| 254 | Alteration t o existing D C Track Circuits to suit R E / N o n R E standard a s per approved signaling p l a n . T h i s work includes provision of d o u b l e bonding and parallel jumpers, provision o f bond wire clips, wherever required, shifting of relay end and feed end equipments and re-wiring them, provision of track lead connections wherever necessary using 2c x 2.5 sq.mm cable. a)Alteration to existing track circuits at feed end | Numbers | 10.00 | 4,234.65 | 42,346.5 |
| 255 | Alteration t o existing D C Track Circuits to suit R E / N o n R E standard a s per approved signaling p l a n . T h i s work includes provision of d o u b l e bonding and parallel jumpers, provision o f bond wire clips, wherever required, shifting of relay end and feed end equipments and re-wiring them, provision of track lead connections wherever necessary using 2c x 2.5 sq.mm cable b)Alteration to existing track circuits at relay end | Numbers | 10.00 | 3,850.31 | 38,503.1 |
| 256 | Excavation o f p i t , c a s t i n g concrete foundation a n d erection o f apparatus case full size as per Drg. No.SG/CN/02/6 and fixing of 2 Nos. of 'E' type locks, one for the front door a n d another for the back door, fixing o f one hard wood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule). [Foundation bolts & nuts, 'E' type locks, cement, M sand, stone jelly of size 20/25 mm, hardwood plank of 37mm thick, paints, varnish, fixing bolts & nuts and a l l other miscellaneous materials required f o r thework shall be supplied by the Contractor.] | Numbers | 42.00 | 11,333.1 | 4,75,990.2 |
| 257 | "Excavation o f pit, casting concrete foundation a n d erection o f apparatus case half size as per Drg, No.SG/CN/02/7, fixing one 'E' type lock f o r t h e f r o n t d o o r and latching arrangement for the back door, and fi x i n g o f o n e hardwood s h e l f plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule).[Foundation bolts and nuts, cement, 'E' type locks, M sand, stone jelly of size 20/25mm,37mm hard wood planks, latching ""arrangements, paints, varnish, fixing bolts & nuts and all other miscellaneous materials required for t h e w o r k s h a l l b e supplied by the Contractor]""" | Numbers | 20.00 | 8,787.04 | 1,75,740.8 |
| 258 | Excavation o f p i t , erection o f cable termination boxes on rails and concreting as per Drg. No.SG/CN/02/8, drilling of suitable holes in the box, fixing of 2 Nos. of GI pipes 32mm dia a n d 300mm l o n g a t t h e bottom with clamp nuts - 12 mm thick, one at the inner side and another at the outer side for each p i p e f o r c a b l e throughing, fixing of hardwood plank 37mm thick on the bottom, provision of one EWS lock, and painting the boxes i n s i d e and outside with one coat of red-oxide and t w o coats o f aluminium paints.(Supply o f C T b o x e s i s n o t covered i n this schedule. Rails o f different length shall be supplied by Railways. The contractor shall cut lengthy rails wherever required.)[Cement, M sand, stone jelly o f size 20/25mm, p a i n t , varnish, GI P i p e s 32mm dia with clamp nuts - 12mm thick - 2 Nos. for e a c h pipe, fixing bolts and nuts with washers, EWS locks, paints and all other miscellaneous materials shall be supplied by the Contractor]. | Numbers | 5.00 | 4,999.16 | 24,995.8 |
| 259 | Fabrication and erection of rail staging, concreting, construction o f stock brick, masonry support, supply a n d provision of concrete slabs 3 Nos. of size 300mm x 1700mm x 8 0 m m f o r platform on stage support for erecting apparatus case full size on embankment and c a s t i n g concrete foundation and erection of apparatus case full size over t h e compacted e a r t h and masonry , fixing 2 Nos. of 'E' type locks, one for the front door and another for the back door, supply and fixing of one hardwood shelf plank of 37mm thick and painting the boxes inside a n d outside with one c o a t of red-oxide a n d t w o c o a t s of aluminium paints. | Numbers | 2.00 | 20,609.19 | 41,218.38 |
| 260 | Fabrication and erection of rail staging, concreting, construction o f stock brick, masonry support, supply a n d provision of concrete slabs for platform, 3 Nos. of size 300mm x 1000mm x 8 0 m m for platform stage support f o r apparatus c a s e h a l f size on embankment and c a s t i n g concrete foundation and erection of apparatus case half size over the compacted earth and masonry work , fixing 1 No. of 'E' type locks, for the f r o n t d o o r a n d t h e latching arrangements f o r t h e b a c k d o o r and fixing one H . W shelf p l a n k o f 37mm thick and painting the boxes inside and outside with one coat o f red-oxide and t w o coats of aluminium paints.(Supply of apparatus case is not included in this schedule. Rails o f different lengths will b e s u p p l i e d b y R a i l w a y a n d the Contractor has to cut the rails to required lengths). | Numbers | 2.00 | 16,011.2 | 32,022.4 |
| 261 | Excavation of pit in and around the existing location boxes v e r y carefully without damaging t h e working cables a n d shifting and turning the location boxes to clear of the infringement as instructed b y t h e Railway representative a t s i t e . T h e work includes ensuring the safety of the signaling system, releasing t h e cable coils t o give access for shifting/turning the location boxes. Necessary masonry work and earth work in and around the location b o x e s t o the required level shall be done as instructed by the Railway representative a t s i t e . I f the e x i s t i n g e a r t h connections t o the location boxes are disturbed, the earth wires shall be properly re-connected. a) Shifting of apparatus case (full) | Numbers | 3.00 | 5,348.81 | 16,046.43 |
| 262 | Excavation of pit in and around the existing location boxes v e r y carefully without damaging t h e working cables a n d shifting and turning the location boxes to clear of the infringement as instructed b y t h e Railway representative a t s i t e . T h e work includes ensuring the safety of the signaling system, releasing t h e cable coils t o give access for shifting/turning the location boxes. Necessary masonry work and earth work in and around the location b o x e s t o the required level shall be done as instructed by the Railway representative a t s i t e . I f the e x i s t i n g e a r t h connections t o the location boxes are disturbed, the earth wires shall be properly re-connected. b) Shifting of apparatus case (half) | Numbers | 3.00 | 3,545.06 | 10,635.18 |
| 263 | Termination o f new main/tail cables on the existing terminals/ fuse blocks in apparatus cases/ batte ry b o x e s / CT boxes/ cable termination racks a s per approved circuit diagram. The terminal p a r t i c u l a r s a r e to be repainted /corrected o n t h e doors of apparatus cases/ battery boxes/ cable termination boxes and FTOT index board as instructed by Railway representative at site. This w o r k includes closing the opening created for entry of new cables i n the apparatus cases w i t h masonry brick work and sealing the bottom of the apparatus cases/ c a b l e termination racks with cable compound.[Paints, wire PVC 3/0.75mm and 16/0.2mm copper, sealing compound, bricks, cement, M sand and all other required miscellaneous materials s h a l l be supplied b y the contractor].(Per Unit = Per Terminal block) | Per Unit | 1000.00 | 73.59 | 73,590 |
| 264 | Termination of main, tail, Signaling and p o w e r cables a n d internal w i r i n g on terminal/ fuse blocks i n n e w apparatus cases, cable termination boxes a n d in gate Lodges e x c l u d i n g cable termination r a c k at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base p l a n k , fi x i n g o f P h y n o l i c synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood items, fixing of terminals/ fuse blocks o n t h e terminal b o a r d , d r i l l i n g of necessary holes, termination o f cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagra m a n d cable plan, painting o f particulars o n sleeves andalso on the inner side of the doors of apparatus cases. After terminations are "over, t h e side openings o f apparatus case foundation s h a l l b e closed with brick work, cement plastered, the inter- space filled with M sand up to base level and the bottom surface shall b e sealed with sealing compound.(Supply of PBT terminals and Fuse blocks is not covered i n t h i s schedule)." a ) Te r m i n a t i o n o n 2 5 / 6 0 m m PBT terminals (new location)(Phynolic sheet) (Per Unit = Per Terminal block) | Per Unit | 6250.00 | 172.14 | 10,75,875 |
| 265 | Termination of main, tail, Signaling and p o w e r cables a n d internal w i r i n g on terminal/ fuse blocks i n n e w apparatus cases, cable termination boxes a n d in gate Lodges e x c l u d i n g cable termination r a c k at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base p l a n k , fi x i n g o f P h y n o l i c synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood items, fixing of terminals/ fuse blocks o n t h e terminal b o a r d , d r i l l i n g of necessary holes, termination o f cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagra m a n d cable plan, painting o f particulars o n sleeves andalso on the inner side of the doors of apparatus cases. After terminations are "over, t h e side openings o f apparatus case foundation s h a l l b e closed with brick work, cement plastered, the inter- space filled with M sand up to base level and the bottom surface shall b e sealed with sealing compound.(Supply of PBT terminals and Fuse blocks is not covered i n t h i s schedule)." b)Termination o n P B T fuse block (new location) (Phynolic sheet)(Per Unit = Per Fuse block) | Per Unit | 800.00 | 209.93 | 1,67,944 |
| 266 | Termination of main, tail, Signaling and p o w e r cables a n d internal w i r i n g by fixing additional terminals/ fuse blocks o n the existing terminal boards of apparatus cases, cable termination boxes etc. T h e work includes fixing of all new cables by teakwood clamp on teakwood b a s e p l a n k , varnishing all teakwood items, fixing of terminals/ fuse blocks, o n t h e existing terminal boards, drilling o f necessary holes, t e r m i n a t i o n of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagra m a n d cable plan, painting o f particulars o n sleeves and also on the inner side o f the doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation s h a l l b e closed with brick work, cement plastered, the inter- space filled with M sand up to base level and the bottom surface shall b e sealed w ith sealing compound. a)Termination o f cables o n 25/60mm PBT terminals (existing location)(Per Unit = Per Terminal block) | Per Unit | 750.00 | 151.09 | 1,13,317.5 |
| 267 | Termination of main, tail, Signaling and p o w e r cables a n d internal w i r i n g by fixing additional terminals/ fuse blocks o n the existing terminal boards of apparatus cases, cable termination boxes etc. T h e work includes fixing of all new cables by teakwood clamp on teakwood b a s e p l a n k , varnishing all teakwood items, fixing of terminals/ fuse blocks, o n t h e existing terminal boards, drilling o f necessary holes, t e r m i n a t i o n of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagra m a n d cable plan, painting o f particulars o n sleeves and also on the inner side o f the doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation s h a l l b e closed with brick work, cement plastered, the inter- space filled with M sand up to base level and the bottom surface shall b e sealed w ith sealing compound. b)Termination o f cables o n P B T f u s e block (existing location)(Per Unit = Per Fuse block) | Per Unit | 100.00 | 188.86 | 18,886 |
| 268 | Charging a n d installation o f secondary cells of t h e following capacities, on existing battery stand/ RCC slabs in the battery room. T h e w o r k involves charging of secondary cells, fixing and connecting the batteries with strips, manufacture and fixing of teakwood terminal b o x , termination of cables, wiring with suitable wire PVC 7/1.40mm and 3/0.75mm copper through suitable PVC pipes/ casing properly clamped, provision o f battery particulars board made of phynolic sheet 6mm thick of size 900mm x 1200mm with Aluminium grooved channel frame i n t h e relay room. T h e particulars shall b e digitally u s i n g good quality "laminated gum sheet, provision of hydrometer -1 No. on a s t a n d a n d battery tester-1 No. Charging o f secondary cells shall be done by the contractor through reputed agencies.(Supply of secondary cells is not covered in this schedule). [ Te a k w o o d p l a n k 2 5 m m t h i c k for manufacturing termination b o x with locking facility, wire P V C 7/1.4mm and 3/0.75mm copper, anti-corrosive paint, varnish, PVC pipes/ casing, and all other miscellaneous materials required for t h i s w o r k s h a l l be supplied by the contractor]." b)Installation o f 2V-200AH cell o n existing stand/ slabs(Per Unit = Per Cell) | Per Unit | 60.00 | 869.41 | 52,164.6 |
| 269 | Charging a n d installation o f secondary cells of t h e following capacities, on existing battery stand/ RCC slabs in the battery room. T h e w o r k involves charging of secondary cells, fixing and connecting the batteries with strips, manufacture and fixing of teakwood terminal b o x , termination of cables, wiring with suitable wire PVC 7/1.40mm and 3/0.75mm copper through suitable PVC pipes/ casing properly clamped, provision o f battery particulars board made of phynolic sheet 6mm thick of size 900mm x 1200mm with Aluminium grooved channel frame i n t h e relay room. T h e particulars shall b e digitally u s i n g good quality "laminated gum sheet, provision of hydrometer -1 No. on a s t a n d a n d battery tester-1 No. Charging o f secondary cells shall be done by the contractor through reputed agencies.(Supply of secondary cells is not covered in this schedule). [ Te a k w o o d p l a n k 2 5 m m t h i c k for manufacturing termination b o x with locking facility, wire P V C 7/1.4mm and 3/0.75mm copper, anti-corrosive paint, varnish, PVC pipes/ casing, and all other miscellaneous materials required for t h i s w o r k s h a l l be supplied by the contractor]." d) Installation o f 2V- 4 0 / 8 0 A H c e l l o n existing stand/ slabs(Per Unit = Per Cell) | Per Unit | 32.00 | 615.08 | 19,682.56 |
| 270 | Provision of signaling arrangement during Non-Interlocked working of Signals and Points, such as erection and wiring of temporary relay racks and wiring of relays, SM's slide instruments, wiring alterations in the cable termination rack, apparatus cases, signals, Control panel etc, as per the instructions of Railway representative at site.(Supply of relay rack, relays, and SM slide instrument is not included in this schedule).[All other miscellaneous materials required for the work shall be supplied by the Contractor]. | Station | 1.00 | 33,631.06 | 33,631.06 |
| 271 | Provision o f P A system a n d Magneto telephone communication a t stations/ tents as per the instructions o f Railway representative a t site. T h e P A system and magneto telephones will be returned to the contractor a f t e r the completion o f NI working. Signalling cables available m a y be used for the communication.(Hiring o f P A system equipments and magneto telephones s h a l l b e d o n e b y the Contractor)[All other miscellaneous materials required f o r t h e w ork shall b e supplied b y the Contractor]. (Per Unit= Per set per day) | Per Unit | 8.00 | 1,637.25 | 13,098 |
| 272 | Hiring o f tarpaulin tents a n d providing the same a t places a s instructed by Railway representative at site. The spacing inside the tent shall be app 8ft x 8 ft. Each tent shall be provided with a table, chair, t u b e lights and pedestal f a n . Drinking water i n cans.The tents shall be fixed firmly t o withstand rain, strong wind etc.(Per Unit = Per tent per day) | Per Unit | 3.00 | 1,328.3 | 3,984.9 |
| 273 | Fixing o f Annunciator a t SM's Room as required by Railways, wiring it as per circuit diagram a n d p a i n t i n g of p a r t i c u l a r s . The work includes connecting 1 No. of magneto telephone with Ni-cad power pack 4V-2.2AH with c h a r g e r t o w o r k o n 1 1 0 V A C and connecting t h e annunciator t o the different telephone c i r c u i t s . The particulars o f the circuits a n d the ringing codes shall be painted on the top of the annunciator box.(Supply of annunciator is not included in this schedule)."[Magneto telephone handle type with Nicad power pac k 4V-2.2AH with charger t o work on 110VAC, wire P V C 16/0.2mm copper, paint a n d all other miscellaneous materials required f o r t h e w ork shall b e supplied by the Contractor]." | Numbers | 1.00 | 4,094.05 | 4,094.05 |
| 274 | Installation of magneto telephones with Nicad pack | Numbers | 12.00 | 3,322.6 | 39,871.2 |
| 275 | Casting concrete foundation and erection and painting of boards with 'LEGEND' such as "Draw close if signal is at on" at the required places as per the Signalling plan. The work involves concreting of rail post to a size of 600mm x 600mm x 900mm and fixing the board to the rail using MS clamps, bolts and nuts. (Supply of boards is not covered in this schedule. Rails of different lengths will be supplied by Railways and the Contractor has to cut them to the required lengths) [Stone jelly of size 20/25mm dia, M sand, cement, M.S.flats, fixing bolts and nuts, paint and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 15.00 | 3,972.14 | 59,582.1 |
| 276 | Provision of HDPE Pipe of dia 40/33 mm | Metre 45000.00 | — | 26.11 | 11,74,950 |
| 277 | Laying of DWC/Split DWC Pipes for Track Crossing/Road Cutting/Trenches | Metre | 2000.00 | 42.46 | 84,920 |
| 278 | "Releasing of existing relay racks/ cable termination r a c k s a l o n g w i t h a l l the terminals, fuse b l o c k s , r e l a y s , with jacks, holding clips etc., 50 way boards, terminals, connecting wires, cables etc., carefully without causing any damage, accounting and stacking them neatly at a place as instructed by Railway representative a t site. After releasing, t h e floor shall b e levelled and cement plastered" | Rack | 5.00 | 1,977.19 | 9,885.95 |
| 279 | Releasing of existing Route Indicators of different types including tail cables, carefully without causing any damage, accounting and stacking them neatly at a place as instructed by Railway representative at site. | Numbers | 16.00 | 1,541.51 | 24,664.16 |
| 280 | "Breaking of concrete and releasing of STOP board/Warning board/ LEGEND boards along with rails, accounting and stacking them neatly a t a p l a c e as instructed by Railway representative at site. Also the resultant pits shall b e re- surfaced and consolidating by ramming and levelling" | Numbers | 15.00 | 1,580.36 | 23,705.4 |
| 281 | Releasing o f existing point lay-out with facing point lock,split stretchers, electrical detector, lock bars, point/trap indicators cranks, r o d s e t c . , carefully w i t h o u t D a m a g i n g the materials, accounting and stacking them neatly at a place as instructed by Railway representative at site. | Set | 5.00 | 2,852.7 | 14,263.5 |
| 282 | Removal o f obstructing sleepers, and rails available in the path of cable trench (Above the ground) | Numbers | 200.00 | 235.47 | 47,094 |
| 283 | Removal o f obstructing sleepers, and rails available in the path of cable trench (buried inside ground) | Numbers | 30.00 | 3,205.7 | 96,171 |
| 284 | Jungle cutting along with the cable route | Metre | 5000.00 | 5.84 | 29,200 |
| 285 | Releasing o f existing apparatus cases (Full/ Half/ Q u a r t e r s i z e ) without damage after releasing the shelf planks, Terminal blocks, Fuse Blocks, Terminal Boards, Relays o f a l l t y p e s EKTs, Secondary Cells, power equipments, 'E' t y p e l o c k s , e t c . , and breaking the concrete foundation. After releasing, the resultant pits are to be closed and consolidated by ramming and levelling. T h e r e l e a s e d m a t e r i a l s s h a l l be accounted and stacked a t a place as instructed by Railway representative at site. | Numbers | 60.00 | 3,006.71 | 1,80,402.6 |
| 286 | Breaking o f concrete and releasing the existing cable termination boxes, after releasing t h e b a s e p l a n k , Terminal blocks, Fuse Blocks, Terminal Boards, c u t rails, pipes, e t c . , c l o s i n g the resultant p i t s and consolidating i t by ramming a n d levelling. The released m a t e r i a l s s h a l l b e accounted and stacked neatly at a place as instructed by Railway representative at site. | Numbers | 50.00 | 2,004.94 | 1,00,247 |
| 287 | Dismantling and releasing of existing Colour light Signals complete (upto 4 aspects) with or w i t h o u t Route Indicators, c a l l i n g on signals, shunt signals etc., carefully without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. The work includes breaking the c o n c r e t e f o u n d a t i o n , c l o s i n g the resultant p i t and resurfacing it by ramming and levelling. | Numbers | 28.00 | 3,083.03 | 86,324.84 |
| 288 | Dismantling a n d releasing o f existing Point machines ( a l l t y p e s ) including ground connections a n d other accessories available complete without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. | Numbers | 10.00 | 2,698.69 | 26,986.9 |
| 289 | Releasing of Secondary cells and battery stands available i n t h e battery room along with connecting strips, wires and terminal boxes carefully without causing any damage to t h e batteries, accounting and stacking them neatly at a p l a c e a s instruc te d by Railway representative a t site. After releasing any holes in the walls/ flooring shall be filled with cement mortar and plastered. | Set | 55.00 | 5,395.99 | 2,96,779.45 |
| 290 | "Releasing of existing ground type shunt signals along with surface base, signal post etc carefully without any damage, accounting and stacking them neatly at a place a s instruc te d b y Railway representative a t site. T h e w o r k also i n c l u d e s b r e a k i n g a n d r e m o v a l of concrete foundation and refilling o f the resultant pit by ramming and levelling." | Numbers | 15.00 | 2,196.41 | 32,946.15 |
| 291 | Releasing of existing TLD boxes with stumps and terminals after releasing all the bond wires. The released materials shall be accounted and stacked neatly at a place as instructed by Railway representative at site. | Numbers | 230.00 | 159.29 | 36,636.7 |
| 292 | Releasing of all power equipments including equipment stands, terminal boards, power panel etc., i n t h e power r o o m carefully without c a u s i n g any d a m a g e t o the equipments after disconnecting all the supply wires. The released equipments shall be accounted and stacked at a place as instructed by Railway representative at site. After releasing any holes in the walls/flooring shall b e filled with cement mortar and plastered. | Set | 1.00 | 12,640.13 | 12,640.13 |
| 293 | Survey o f Cable Route and Preparation of Cable Route Plan | Kilometre | 12.00 | 716.01 | 8,592.12 |
| 294 | Provision of one skilled and 2 unskilled staff round t h e c l o c k t o a t t e n d the teething trouble of the installation along with SSE/JE after t h e installation has been brought into commissioning. The w o r k i n c l u d e s routine maintenance, failure restoration as per the direction of the SSE/JE | Month | 6.00 | 73,903.01 | 4,43,418.06 |
| 295 | Videography of cable Route | Kilometre | 10.00 | 519.85 | 5,198.5 |
| 296 | Providing the services of Computer oriented technical m a n p o w e r to c a r r y o u t w o r k s like Drawing, c o m p u t a t i o n , w r i t e u p e t c . , using computer, using software like AUTOCAD, MS Office etc., for 08.00 hrs i n a d a y w i t h all expenses of transportation, accommodation, food, consumables e t c . , w i t h a l l ascents, descents, t a x e s , o c t r o i , c e s s , fees, duties, duties with contractors cost etc., as per special conditions/ specifications/ regulations and as directed by Engineer-in-charge. Note: The person engaged for providing the services shall b e convergent w ith computer working knowledge in above software. | Man- Days | 150.00 | 913.28 | 1,36,992 |
| 297 | Protection adjustments and re-instating of S&T gears by deputation of Helpers/Unskilled Labour for executing additional S&T portion of the works. The w o r k can involve fixing, releasing, dismantling, replacement,excavation, clearing of vegetation, loading and unloadingof material and assisting skilled persons etc as per instruction of Railway representative. | Man- Days | 300.00 | 847.59 | 2,54,277 |
| 298 | Protection, adjustment a n d reinstating of S&T g e a r s b y d e p u t a t i o n of Fitter/Wireman/Painter/Welder/ Mason/Cable Jointer (Skilled Labour or Te c h n i c i a n ) etc., for executing additional S & T portion of works. The w o r k c a n i n v o l v e fixing, releasing, dismantling, replacement, painting or alteration of various signallilng assets or p a r t s , termination o f c a b l e s , minor patch work on damages at location box, Plastering, Concreting brick work, wiring alterations, cable jointing e t c a s per instruction of Railway representatives at size. | Man- Days | 90.00 | 1,073.45 | 96,610.5 |
| 299 | Transportation of Signalling materials by road a s per the instructions o f Railway representative a t site. T h e w o r k also includes loading a n d unloading o f the materials a)Transportation o f Signalling materials upto 100kms | MT-Km | 1100.00 | 22.75 | 25,025 |
| 300 | Transportation o f Signalling materials more than 100km | MT-Km | 500.00 | 13.91 | 6,955 |
| 301 | Engaging mechanical excavators like JCB or other machineries for regarding and levelling the formation, dismantling a n y infringing structures, clearing and removing debris etc., with all leads and l i f t s e t c . , complete and a s p e r the instruction of Railway representative at site. | Hour | 110.00 | 1,202.5 | 1,32,275 |
| Schedule total | ₹18,57,84,354.34 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
ACS1.pdf
ATTACHMENT
ACS2.pdf
ATTACHMENT
ACS3.pdf
ATTACHMENT
ACS4.pdf
ATTACHMENT
ACS5.pdf
ATTACHMENT
ACS6.pdf
ATTACHMENT
ACS7.pdf
ATTACHMENT
ACS8.pdf
ATTACHMENT
ACS9.pdf
ATTACHMENT
ACS10.pdf
ATTACHMENT
ACS11.pdf
ATTACHMENT
GCC_April-2022.pdf
ATTACHMENT
JPO Ann
ATTACHMENT
SOR2022.pdf
ATTACHMENT
PTJ Coaching Terminal Tentative SIP
ATTACHMENT
PTJyardESP-approved.pdf
ATTACHMENT
PTJ_CT_TenderDocument.pdf
ATTACHMENT
jpo_ann_to_cir_17-2013_41.pdf
ATTACHMENT
PTJcoachingTerminal-Tentative-SIP.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .