GE (SOUTH) PATHANKOT
REPR OF INT ELCTC SYSTM CELNG EXUST VENTI FANS OF OTMMD ACCN CNVNTONL INT LIGHT FTNG WITH ENERGY SAVING LED LIGHT FTING LIGHTG PROTN SYSTM BUILD ERTHN WNDOWSPLITAC STORAGE WATER HETR DSERT COLER AND OTHER ALED WORKS AT BHADORIYA COMPLX UNDER GE S PTK
2022_MES_542433_1
GES/PKT/T-30/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (SOUTH) PATHANKOT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (SOUTH) PATHANKOT
₹86,000
Yes
25 Oct 2022
1 Aug 2022
1 Sept 2022
1 Aug 2022
30 Aug 2022
16 Aug 2022
Amount
Dismantling and taking out burnt winding by cutting, cleaning slots and re-winding of AC ceiling fan motor 1200mm of any make of fan with super enameled copper winding wire of existing gauge including, sleeve work, varnishing with E class insulation varnish, complete all as spd and directed including taking down & refixing the same (Note :- (i) Doctor brand or equivalent ISI brand varnish shall only be used), (ii) Motor shall be wound with machine only.(iii) BIC/HTP or DEVIDYAL, make super enameled copper winding wire shall only be used.
Dismantling and taking out burnt winding by cutting, cleaning slots and re-winding of AC ceiling fan motor 1400mm of any make of fan with super enameled copper winding wire of existing gauge including, sleeve work, varnishing with E class insulation varnish, complete all as spd and directed including taking down & refixing the same(Note :- (i) Doctor brand or equivalent ISI brand varnish shall only be used), (ii) Motor shall be wound with machine only.(iii) BIC/HTP or DEVIDYAL, make super enameled copper winding wire shall only be used.
Replacement of old unserviceable gun metal bush of ceiling fan complete all as spd and directed.
Replacement of old unserviceable capacitor AC 400/415 volts 2.5 mfd ISI marked complete all as spd.
All as per Srl item 4 above but 3.15mfd complete all as spd.
Replacement of old unserviceable ball bearing suitable for 1200/1400 mm sweep complete. Make NBC/SKF (bearing with 8 balls shall only be used) complete all as spd.
Replacement of old unserviceable shackle assy kit (rubber real -01, MS split clamp two Nos, nuts and bolts washers 2 Nos & split pin -02 Nos) suitable for ceiling fan 1200/1400mm sweep complete all as specified and directed.
Replacement of old unserviceable fan blades, ISI Marked, suitable for 1200/1400mm sweep ceiling fan of any make complete all as spd.
Repalcement of old unserviceable MS down rod of appropriate External dia of ceiling fan complete (length of rod not less than 45cm and not more than 60cm and 15 mm dia) complete all as spd.
S&F Canopy for ceiling fan as per existing sample complete all as specified and as directed.
S&F PVC Two way connector for ceiling fan complete all as specified and directed.
Replacement of old unserviceable steel screw (to be used for fixing of fan blade) as per sample/ site requirement/ Make of fan complete all as spd.
Servicing of ceiling fans of capacity 1200/1400mm including taking down from site, dismantling, cleaning, greasing/ oiling of bush and bearings, replacement of set of split pins, cotter pins, blade screws and refixing to the existing site after servicing complete all as directed by Engr-in-Charge. (Unserviceable parts if any will be measured and paid seperately).
S&F cable PVC insulated and overall sheathed with flexible copper conductor Single core of size 1.0 sqmm complete all as specified and directed.
Dismantling and Re-winding of exhaust fan/industrial fan motor 250-300 mm sweep any make of fan with super enameled copper winding wire of suitable gauge as per existing including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections fan complete all as spd and directed (Note :- (i) Doctor brand or equivalent ISI brand varnish shall only be used).(ii) Motor shall be wound with machine only.(iii) BIC/HTP or DEVIDYAL, make super enameled copper winding wire shall only be used.
All as per Srl item 15 above but 350mm-450mm sweep complete all as spd and directed.
Dismantling of wall/pedestal fan of any sweep, repair the same by cleaning, overhauling, necessary lathe work (grinding & polishing) etc and taking out existing burnt out winding wire of motor and rewinding the same with super enamelled bare insulated copper winding wires as per existing gauge and turn to achieve desired RPM including necessary insulating materials, insulating varnishing, cleaning and reassembling the wall/pedestal fan after replacement of unserviceable minor parts such as frame nut, knob, regulator switch clamp of cendenser etc as required for smooth functioning of the fan and Replacement of unserviceable major parts like capacitor, bearing, bush etc and testing complete on completion and re-fixing the fan in existing position including provn of twin twisted flexible copper stranded conductor wire of size 23/0.0076 Sqmm of required length complete as directed by the Engineer-in-Charge (Note : (a) Replacement of unserviceable major parts like capacitor, bearing, bush etc shall be measured and paid separately as "Supply only" under respective items of this Schedule. (b) Unit quoted rate shall deemed to be inclusive of transportation of fan to workshop form MES store yard)
S&F louver, suitable for exhaust fan of any make and size upto 300-350 mm, fixed in repair complete all as specified and as directed.
All as per items 18 above but of size 400 mm-450 mm
Removing old paint by scraping with sand paper including washing and filling cavaties with filter and applying two coats of painting to ceiling fan 1200-1400mm sweep at site with synthetic enamel paint by spray painting Complete all as specified and directed.
Removing old paint by scraping with sand paper including washing and filling cavaties with filter and applying two coats of painting to exhaust fan/wall mounting fan/Padestial Fan of any sweep at site with synthetic enamel paint by spray painting Complete all as specified and directed.
S&F in repair ceiling fans 1200 mm Sweep Ceiling Fan, Energy Saving, BLDC Motor without romote complete with canopy, blades, down rod, split pin etc complete of approx wattage 30 to 32 Watt rated suitable for operation on AC 220-240 V AC, 50 HZ, PF >0.95, Air delivery approx 230 cum/min including dismantling old UNSV fan and depositing to MES store yard.
S&F in repair Ventilation fan AC sinlge phase 230/240 volts of size 200 to 250 mm sweep PVC body with louvre including connecting to ceiling rose and dismantling old UNSV fan and depositing to MES store yard all as specified and directed.
S&F Exhaust fan AC sinlge phase 230/240 volts of size 300 mm sweep steel body with louvre including connecting to ceiling rose and dismantling old UNSV fan and depositing to MES store yard all as specified and directed.
S&F Exhaust fan AC sinlge phase 230/240 volts of size 450 mm sweep steel body with louvre including connecting to ceiling rose and dismantling old UNSV fan and depositing to MES store yard all as specified and directed.
S&F in repair wall mounted fan 400 mm Sweep Energy Saving, copper wounded Motor, three speed control complete suitable for operation on AC 220-240 V AC, 50 HZ, PF >0.95, Air delivery approx 230 cum/min including dismantling old UNSV fan and depositing to MES store yard
Disconnecting the inlet/outlet water connections and electric connections of Storage storage type electric water heater of capacity 25 Ltrs capacity, taking down carefully from wall after unscrewing nut/bolts ,checking the outer body for any cracks and strip opening the same carefully for thorough inspection of serviceablity/functionality of parts such as internal tank, syphon assembly, thermostat switch, heating element, glass wool etc, servicing complete and re-assembling and re-fixing after repair,fixing to wall testing, installation and commissioning all as directed. Note: (a) The spares required for replacemeny shall be measured and paid under relevant Schedule items of Sch here-in-after.
Supply only internal SS tank of storage type electric water heater of 25 ltr capacity complete with syphon –assembly, 1.5 KW/2.0 KW element , rubber gasket , thermostat switch , all as specified and directed for carrying out repairs under relevant item No.27 . Note :- The tank shall be tested at site and shall be able to with stand requisite pressure . Necessary testing equipment shall be arranged by the contractor . Tank with stud type round element shall only be used . (Triangular element shall not be allowed .)
Supply only syphon assembly made out of SS of 25 ltr capacity including necessary studs screws and rubber gasket/washers matching with existing/new inner tank complete all as spd and directed for carrying out repairs under relevant item No.27.
Supply only thermostat switch ISI marked for storage type electric water heater AC 230 volt adjustable range from 0-90 degree Celsius ) for carrying out repairs under relevant item No.27
Supply only cup/triangular type storage type electric water heater element AC 230 volt, of rating 1500/2000 watt for carrying out repairs under relevant item No.27.
Supply only outer body suitable for 25 ltr storage type electric water heater made out of MS sheet factory made complete with fixing bracket matching with existing complete all as specified and directed for carrying out repairs under relevant item No.27
Supply only glass wool of 25 ltrs capacity storage type electric water heater complete all as specified and directed for carrying out repairs under relevant item No.27
Supply only indicator lamp square/round type suitable for storage type electric water heater 25 ltr all as per sample AC 230 Volt for carrying out repairs under relevant item No.27
Supply and replacement cable flexible PVC insulated, PVC sheathed, copper conductor, 3 core 70/.0076mm.
S&F sheet metal enclouser single pole and neutral with a 2 pin and earth plug and socket 20 A 240V complete with one single pole MCB of capacity 20 A complete all as specified and directed.
De-scaling of storage type electric water heater of capacity 25 ltr after taking down the storage type electric water heater from wall, strip opening the assembly, de-scaling the syphon assembly and refixing the assembly and re-installation of storage type electric water heater complete all as directed.
S&F PVC connection 15 mm size with PTMT nuts of length 450 mm ISI Marked all as specified and as directed.
Replacement of spring loaded air release valve ISI marked suitable for 25 ltrs capacity storage type electric water heaters.
Replacement of safety valve/ dead wt. valve ISI marked suitable for 25 Ltrs capacity storage type electric water heaters.
S&F pillar taps, cast copper alloy with capastan heads, chromium plated, screwed down high pressure with lettered ‘Hot or Cold’ with long screwed shanks and fly nuts, screwed for iron pipe and fixed fancy type of size 15 mm.
S&F gun metal glove or gate valves with iron wheel head, screwed both ends for iron pipe and fixed of size 15mm.
S&F anchor bolt 12mmX100mm long complete all as spd and directed (Note:- Anchor bolt shall be grouted with hammer drill only)
Preparing the old surface by rubbing/scratching the old paint and providing the one coats of synthetic enameled paint through spray paining of 25 ltr storage type electric water heater.
S&F brass non return valve suitable for 25 ltr storage type electric water heater of size 15 mm.
S&F bottom cover plate of storage type electric water heater of capacity 25 ltr complete with MS screw all as per sample.
Dismantling of Insulated hot water storage tank of capacity up to 500 Ltrs connected Solar Evacuated collectors/ flat collectors and cold water tank with GI fittings & PVC pipe connection. Servicing,Testing, Commissioning & descaling of Hot water storage tank removing of corrosion/dust, replacement of UNSV PVC pipe after re-fixing the same.
Service and descaling of Solar Evacuated tube Collector/ Flat collectors with sulphuric acid by forcefully injecting the hot chemical into collector for number of times to clean the Solar Solar Evacuated tube Collector/Flat Plate Collector and assembled the same.
S&F in replacement of Evacuated tube collector for Solar Water Heater of capacity Upup 500 LPD of suitabale size as per sample approved by Engineer -in-charge on the gound.
Replacement of heating element 2/3 KW suitable for stand by back up supply to solar water heater.
M & L for replacement of unserviceable stop valves and S & F stop valves , cast copper allow, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or fixed Size 15mm ISI mark.
Dismantling old unserviceable storage type electric water heater and depositing it to MES store yard. Supply, install, testing and commissioning of storage type electric water heater of 25 ltr capacity, BEE 5 star rated suitable for 8 bar pressure with nano polymer coated tank, incoloy heating element, rust proof ABS body etc complete all as specified and directed.(Note : Rate quoted deemds to be inclusive of anchor bolt, and pvc connetion)
Dismantling old unserviceable storage type electric water heater and depositing it to MES store yard. Supply, install, testing and commissioning of storage type electric water heater of 50 ltr capacity, BEE 5 star rated suitable for 8 bar pressure with nano polymer coated tank, incoloy heating element, rust proof ABS body etc complete all as specified and directed. (Note : Rate quoted deemds to be inclusive of anchor bolt, and pvc connetion)
Supply only wiring for desert cooler including all accessories all complete diected for carrying out repairs under relevant item.
Supply only blower motor of single way shaft 240 Volts 50 c/s of suitable capacity for desert cooler of capacity 3000 CFM to 5000 CFM single way shaft 240 Volts 50 c/s complete all as specified and directed for carrying out repairs under relevant item.
Supply only water circulation pump suitable for desert cooler of capacity 3000 CFM to 5000 CFM 240 volts 50 c/s single phase complete all as specified and directed for carrying out repairs under relevant item.
Supply only Khaskhas pad honey bee type (set of 3) for Desert Cooler of any capacity ( Set of three) complete all as specified and directed for carrying out repairs under relevant item.
Removing the old paint from the body of desert cooler making the body dust proof and preparing the surface and painting the desert cooler with one coats of synthetic enamel paint of superior quality over a coat of Red Oxide primer all as specified.
Removing the old rusted base tub of desert cooler of 3000 to 5000 cfm capacity and fabrication of base tray and top cover made of PGI sheet of minimum 0.8 mm thick sheet and fixing in position using necessary nuts, bolts and washers all as specified and directed.
S&F in replacement of existing UNSV galvanized iron top cover of minimum 0.8 mm thick sheet per and providing new one of existing size, gauge and shape ,nuts and bolts suitable for 3000 to 5000 cfm capacity Desert Cooler complete all as specified and directed
S&F in replacement of existing UNSV galvanized iron side pillar of minimum 0.8 mm thick sheet as per and providing new one of existing size and shape ,nuts and bolts suitable for 3000 to 5000 cfm capacity Desert Cooler complete all as specified and directed by Engr-in-Charge
S&F in replacement of existing UNSV galvanized iron side shutter of minimum 0.8 mm thick sheet as per and providing new one of existing size and shape ,nuts and bolts suitable for 3000 to 5000 cfm capacity Desert Cooler complete all as specified and directed by Engr-in-Charge.
M&L in replacement of Fan blade hub assly only for Blower motor of desert cooler made of alloy/ Forged steel suitable for 3000 to 5000 cfm capacity Desert Cooler complete all as specified and directed
M&L in replacement of Leg set complete for fixing blower motor for desert cooler complete with all necessary fixing/Fastening arrangements(As per sample) suitable for 3000 to 5000 cfm capacity Desert Cooler complete all as specified and directed
M&L in replacement of water distributor and PVC pipe connection for water connection of desert cooler 3 piece (length not less than 35 cm each piece) (As per sample) suitable for 3000 to 5000 cfm capacity Desert Cooler complete all as specified and directed
M&L in replacement of Capacitor of capacity 4mfd suitable for desert cooler complete all as specified and directed
Dismantling old defective desert cooler and depositing to MES store yard. Supply, install, test and commissioning of desert cooler electric driven, single phase of approx minimum size 575x575x800 mm made out of 0.8 mm thick GI sheet for body, with water tank of capacity 50 Ltr made out of 1 mm thick and with front grills and side direction grills, suitable for minimum air Delivery- 4000 Cum/hr,approx 450 mm sweep fan size with mild steel curved blades duly painted with synthetic anti corrosive paint, fitted to body including prewired electric 4 speed switch control and one 6Amps piano switch. Water immersed pump of suitable capacity 1300 RPM rated suitable for 230 volts, 50 Hz AC supply and one 6 Amps piano switch with fan motor of minimum capacity 105 watt, 1400RPM, 230 volts, 50 Hz and water inlet pipe with brass float valve of size 15mm and outlet with brass drain plug of 20mm .The pad of 3 sides shall be of honeycomb type, including stand of minimum height 900 mm made out 25mmx25mmx3mm MS angle iron , duly coated with weather proof paint of black colour
S&F plug top polycarbonate 3 pin, 5Amp all as specified and directed by Engr-in-Charge
S&F PVC insulated and PVC sheathed 3 Core copper conductor flexible round cable of 02 Sq mm all as specified and directed by Engr-in-charge
Taking down carefully aluminum/copper point wiring (light fan socket or power) complete with fitting such as switches, tube lights, ceiling rose, pendants, regulators, MCB DB, MCB'S, Main switch from control board and making good disturbed surfaces of walls, floor to match with existing specification complete and all as specified and directed.
M&L for point wiring with FRLS PVC insulated fire retardant stranded copper conductor cable of 1.5 sqmm in FRLS PVC concealed conduit heavy duty and pressed steel terminal boxes (for mounting switches /sockets/ regulators/ceiling roses etc ) made of not less than 16 gauge MS sheet and 6cm depth covered with 3mm thick laminated bakelite sheet fitted with brass screw and washers and drawing 1.5 sqmm PVC insulated fire retardant stranded copper conductor cable as earth continuity wire in green colour connected to common earth and each terminal box/fitting all as specified and directed by Engr-in-Charge.( In ceiling Portion surface conduit wiring shall be carried out.) Note: The quoted rate inclusive for the following :- (a) Proper colour coding is to be followed as per IS Specification. (b) Test certificates of cables to be submitted before commencement of work/ claiming for payment.(c) wiring shall be concealed/ on surface with rigid PVC conduit medium grade as per site requirement.(d) Electric Wiring test sheet before and after completion of wiring to be submitted before claiming payment
All as per srl item 73 above but for one light point controlled by 2 nos two way switches.
All as per srl item 73 above but for one 3 pin 5A socket outlet independent board.
All as per srl item 73 above but for one 5A socket outlet on the same board
All as per srl item 73 above but for one 5A socket outlet below the board.
All as per srl item No 77 above but for 15/16 Amps socket out let independent with 4.0 sqmm copper conductor.
M & L for replacement of existing un-serviceable switch with switch piano polycarbonate body flush button single pole two way 5 amps, 230 volts.
M & L for replacement of existing un-serviceable switch with switch piano polycarbonate body flush button single pole two way 15 amps, 230 volts.
M & L for replacement of existing old u/s switch with switch piano polycarbonate body type single pole one way 5/6 Amp, 230 volts.
M & L for replacement of existing old u/s switch socket combination with socket combination Polycarbonate body 2 in 1, 3 pin, 5 Amp and 15 Amp flush type all as specified and directed.
M&L for replacement of existing old u/s switch socket combination with socket combination Polycarbonate body ,5 pin , 5 Amp flush type all as specified and directed.
M&L for replacement of existing old u/s socket outlet with socket outlet Polycarbonate body , 5 pin 5 Amp flush type all as specified and directed.
M&L for replacement of existing old u/s bell push with bell push polycarbonate body type 5/6 Amp, 230 volts.
M&L for bell electric heavy duty Ding Dong type 230 volts single pole complete and all as specified.
M&L for replacement of existing old u/s fan regulator with fan regulator electronic, step type hum free suitable to control speed of fan from 0 to 100% and connecting electrically all as required or directed
M&L for replacement of existing old u/s ceiling rose with ceiling rose Polycarbonate body surface bakelite 2 to 3 terminals, 230 volts.
S&F for replacement of existing old u/s lamp holder with lamp holder batten type polycarbonate body with back plate for batten fitting all as directed.
M&L for Modular point wiring with FRLS PVC insulated fire retardant stranded copper conductor cable of 1.5 sqmm in FRLS PVC concealed conduit heavy duty and pressed steel terminal boxes (for mounting switches/sockets/ regulators/ ceiling roses etc)made of not less than 16 gauge MS sheet and 6cm depth covered with 3mm thick laminated bakelite sheet fitted with brass screw and washers and drawing 1.5 sqmm PVC insulated fire retardant stranded copper conductor cable as earth continuity wire in green colour connected to common earth and each terminal box/fitting all as specified and directed by Engr-in-Charge.( In ceiling Portion surface conduit wiring shall be carried out.) Note: The quoted rate inclusive for the following :- (a) Modular inner and outer frame plate shall be included in quoted rates (b) Proper colour coding is to be followed as per IS Specification. (c) Test certificates of cables to be submitted before commencement of work/ claiming for payment.(d) wiring shall be concealed/ on surface with rigid PVC conduit medium grade as per site requirement.(e) Electric Wiring test sheet before and after completion of wiring to be submitted before claiming payment
All as per srl item 90 above but for one 3 pin module socket out let 5/6 Amps on same board.
All as per srl item 90 above but for one module socket out let 5/6 Amps on Independent board.
All as per srl item 90 above but for one module socket out let 5/6 Amps on below the board.
All as per srl item 93 above but for 15/16 Amps socket out let independent with 4 sqmm copper conductor.
M&L for replacement of existing un-serviceable switch piano with Modular switch 1 way 6A, 1 module ISI marked complete all as spd and directed complete all as spd and directed.
M&L for replacement of existing un-serviceable switch piano with Modular switch 2 way 6A, 1 module ISI marked complete all as spd and directed complete all as spd and directed.
M&L for replacement of existing un-serviceable switch piano with Modular switch 1 way 16A, 1 module ISI marked complete all as spd and directed complete all as spd and directed.
M&L for replacement of existing un-serviceable bell push with Modular bell push 6A, 1 module ISI marked complete all as spd and directed complete all as spd and directed.
M&L for replacement of existing un-serviceable socket outlet with Socket, 6A - 2/3 pin combined 2 module complete all as spd and directed complete all as spd and directed.
M&L for replacement of existing un-serviceable socket outlet with Socket, 16A - 2/3 pin combined 2 module complete all as spd and directed complete all as spd and directed.
M&L for replacement of existing un-serviceable fan regulator with modular fan regulator step type 120 watts 2 module complete all as spd and directed complete all as spd and directed.
M & L for replacement of existing old u/s submain wiring with two single core PVC insulated flexible copper conductor cable of size 4 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 4 Sqmm as earth lead in and including concealed PVC conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed.
M & L for replacement of existing old u/s submain wiring with two single core PVC insulated flexible copper conductor cable of size 6 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 6 Sqmm as earth lead in and including concealed PVC conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed. Note: The quoted rate inclusive for the following :- (a) Proper colour coding is to be followed as per IS Specification. (b) Test certificates of cables to be submitted before commencement of work/ claiming for payment.(c) wiring shall be concealed/ on surface with rigid PVC conduit medium grade as per site requirement.(d) Electric Wiring test sheet before and after completion of wiring to be submitted before claiming payment
M & L for replacement of existing old u/s tube light fitting with energy saving decorative batten type fitting with LED tube rod 18/20 watt energy efficient tube light fittings LED complete with 4 feet long channel type made out of CRCA sheet powder coated complete with housing with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting (fittings shall be fitted on two plastic square/ round block. Note power factor should not be less than 0.90.
S&F LED Bulk head light fitting 1 X 13.5watts cool Daylight (CDL) round type premium quality diffuser for even distribution of light complete , connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm all as required.
M & L for replacement of existing old u/s mirror light fittings with sleek energy efficient decorative LED mirror light 10 watts, 2 feet with diffuser complete with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceilling rose/PVC connector to light fittings ( fittings shall be fitted on two plastic square/round block. Note power factor should not be less than 0.90.
S&F LED Lamp 230 volts,50 Hz,inverter LED 10 watt ,lumen 900 lm, Charging time 8 to 10 Hours, backup time 04 Hrs, operating temperature -10 to 50 degree celcius,back time 04 Hours, complete all as specififed and direccted.
M & L for replacement LED lamp 7 watt , 230 volts retrofit type complete all as spd and directed by Engr-in-chrage.
M & L for replacement LED lamp 15 watt , 230 volts retrofit type complete all as spd and directed by Engr-in-chrage.
M & L for replacement LED lamp 12 watt , 230 volts retrofit type complete all as spd and directed by Engr-in-chrage.
S&F in replacement sheet metal enclosure 4 way , with SPN DB's (grouted in walls) double door type IP-43 Protection. Isolated Neutral,Door earthing, cement spill protector, IK-08 complete including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge (Outgoing MCB will be measured separately).
S&F in replacement sheet metal enclosure 8 way, with SPN DB's ( grouted in walls) double door type IP-43 Protection. Isolated Neutral,Door earthing, cement spill protector, IK-08 complete including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge (Outgoing MCB will be measured separately).
S&F in replacement sheet metal enclosure 12 way, with SPN DB's (grouted in walls) double door type IP-43 Protection. Isolated Neutral,Door earthing, cement spill protector, IK-08 complete including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge (Outgoing MCB will be measured separately).
S&F in replacement of existing old u/s MCB SPN with MCB SPN C curve ,240 volts any rating from 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables.
S&F in replacement existing unsv distribution board iron clad, with double door 4 way with IP-54,1K-09 protection, cemet spill prptector suitable for MCCB as incommer AC 415 Volts three pole with thermal release adjustable type (80% to 100 % ) and MCB as outgoing ,complete with appropriate size copper bus bar and neutral link complete with one MCCB 3 pole 415 Volts 100 Amps rating with rupturing cap 25 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge (Outgoing MCB will be measured separately).
M&L for Replacement of unserviceable MCCB 100 Amps current carrying capacity 16 KA, AC 415 Volts three pole complete all as specified and directed. including dismentling the existing with all connections & fixing the new with all connections all as directed by Engg-in-charge.
S&F in replacement MCB single pole 240 volts any rating 6 to 32 amps, with rupturing capacity 10 KA, complete all as specified and as directed.
M&L for Replacement of unserviceable MCCB 100 Amps current carrying capacity 16 KA , AC 415 Volts three pole complete all as specified and directed. including dismentling the existing with all connections & fixing the new with all connections all as directed by Engg-in-charge.
S&F in replacement MCB single pole 240 volts any rating 6 to 32 amps, with rupturing capacity 10 KA, complete all as specified and as directed.
Repair, maint and making the continuity of supply after rectifying the defects of the electrical items such as switches, replacement of fuse wires, distribution boards, MCB (light/power), lamp holders (bracket/ pandents/ batten), bell/buzzer, push button, ceiling rose, capacitors, geyser, fans etc and other similar electrical items/fittings etc. including providioning of small pieces of electrical wire if required of size 1.5 sqmm to 2.5 sqmm single core and length not exceding 0.50 mtrs complete all as specified and directed by Engineer-in-Charge. (Note :- (i) any accessories found unserviceable that shall be paid as supply only under respective items of this Sch 'A' . (ii) One job only will be considered for each bldg/Qtr per day irrespective of the No of points made serviceable.(iii) The area for attending the complaints are Entire Bhadoriya complex (iii) Each complaint attended/rectified shall be measured as one job. (iv) The contractor shall depute necessary man power on daily basis for rectifying the jobs including sundays and holidays.(v) The contractor should deploy the manpower from the day of exceptance of contractor, (vi) Fine for Rs 500 per day shall be chraged to the contractor for not deploying of man power on any day.
S&F socket outlet Polycarbonate body 2 in 1, 3 pin 15 Amp flush type all as specified and directed.
S&F socket outlet Polycarbonate body , 5 pin 5 Amp flush type all as specified and directed.
S&F in repair of Hylum sheet 5x5 to 10 x 12 inches for fixing of switches, sockets etc including cutting for fixing on existing or new sunken box with brass screw complete all as specified and directed by Engr-in-charge
Supply & fixing in repair of pressed steel terminal boxes (for mounting switches /sockets/ regulators/ceiling roses etc ) made of not less than 16 gauge MS sheet and 6cm depth of size 4x4 to 10 x 12 inches for fixing bakelite sheet of suitable size complete all as specified and directed by Engr-in-charge
S&F in repair ceiling rose Polycarbonate body surface bakelite 2 to 3 terminals, 230 volts.
Supply only FRLS PVC insulated fire retardant stranded copper conductor cable of 1.5 sqmm , cut to size all as required at site.
Supply only FRLS PVC insulated fire retardant stranded copper conductor cable of 2.5 sqmm , cut to size all as required at site.
Supply only FRLS PVC insulated fire retardant stranded copper conductor cable of 4.0 sqmm , cut to size all as required at site.
Supply only FRLS PVC insulated fire retardant stranded copper conductor cable of 6.0 sqmm , cut to size all as required at site.
S&F in replacement of old u/s service cable size 6 sqmm, twin core multistranded 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service with galvanised steel wire complete all as spd and directed.
All as per srl item 130 above but for service cable of size 10 sqmm,complete all as spd and directed.
All as per srl item 130 above but for service cable of size 16 sqmm,complete all as spd and directed.
Taking down old unserviceable security light fittings from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 2500 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 25 watt, complete using bracket of suitable size fixed on wall with clamps, including making connection with 03 core copper cable of size 1.5 Sq mm all as specifed and directed by Engr-in-Charge
S&F AC single phase 10-60A Net Meter DLMS compiance of accuracy class 1.0, 240V 50 Hz, with backlit LCD, Optical port (measures Import KWh, Export kWh, net kWh, V,I,kW, 6 month history of Energy), with Rs232 Port including dismatling of existing meter and deposting it yto MES store Yard, making all necessary input and output connection of the new energy meter. Complete ass as specified by Engr-in-charge.
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below normal ground level )with top edge of the plate not less than 1.5 Mtr below normal ground level connecting with galvanized iron GI earth wire 4mm dia by means of bolt nut check nuts and washers of galvanized iron and provision of GI tubing medium grade (ISI marked)of size 15mm for protection of GI earth wire upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing). and dismantling old defective earthpit.
M&L earthing with steel earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing). and dismantling old defective earthpit.
M&L for fixing in repairs Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required with galvanised iron strip 32x6 mm including dismantling old one.
M&L for fixing in repairs Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required with 4mm dia galvanised iron or steel wire including dismantling old one.
Cutting the tarmac / hard standings and excavating in trenches across the road for laying cable including making good the excavated portion by means of PCC 1:3:6, type C1 matching with the surroundings all as directed.
S&F in repair Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete with saddles and insulators made out of porcelain and fixing screws for roof conductor/down conductor including nut bolts& washers drilling and riveting for joints of suitable size as required at site all as specified and directed by Engr -in- Charge. Note :- Porcelain insulators are to be fixed at an interval of not more than 75 cm
S&F in repair Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete with saddles and insulators made out of porcelain and fixing screws for roof conductor/down conductor including nut bolts& washers drilling and riveting for joints of suitable size as required at site all as specified and directed by Engr -in- Charge. Note :- Porcelain insulators are to be fixed at an interval of not more than 75 cm
S&F in repair air termination single pointed aluminium rod 12mm dia and 300 mm long for fixing on GI pipe medium grade 40mm dia pipe duly making suitable fixing arrangement of one end of air termination rod all as specified and directed by engr-in-charge. Note: GI pipe required will measured and paid separately.
M&L for plain Cement concrete 1:2:4 type B-1, (Using 20 mm graded aggregate) as in foundation block for fixing GI pipe for installation of air termination rod etc. complete all as specified Note:- Unit rates includes for provn of form work for rough finished surfaces and finishing the exposed surfaces with 5 mm thick rendering in CM 1:3 all specified.
S&F in repair GI pipe medium grade 40 mm dia for fixing Aluminium strip 25x3.15 mm on roof for lightening protection duly drilling 2 Nos holes on Aluminum strip and GI pipe on one end and fixing with screws/suitable size of bolts & nuts complete all as specified. Note: GI Strip required will measured and paid separately.
S&F in repair Test point terminal block made aluminum strip 25 x 3.15 mm of size 75x75 drilled and screwed on insulators compleete all as specified and directed.
S&F in repair Porcelain insulators fixied with two number of nuts and fixing of down/roof conductors including taking down of old ones complete all as specified and directed by Engr-In-Charge
M&L for complete repair to 1.5 TR/ 2 TR Capacity out door unit of Split type AC Unit, including taking down all the components tinkering the rusted portion, renewal of complete rusted sheet metal parts, with the same thickness M.S. sheet as per the existing size & shape including cutting, bending welding, drilling etc., including renewal of all nut & bolts sheet metal screws, mounting legs, rubber bushes, and cleaning & prepare the surface thoroughly, applying two coat of synthetic enamel paint over a coat of red oxide primer fixing of all components, brazing the refrigeration piping and shifting to its original position and connecting up all electrical connections and testing all as specified as directed by Engineer-in-Charge. Note : Rate quoted is deemed to be inclusive of cutting, welding, brazing, sealing the refrigerant tubing, replacement of strainer, CTC, Nitrogen gas, Refrigerant gas, required to and from Transportion and Handling. M/L for spares will be measured and paid separately
M&L for taking down the damage condenser fan blade of 1.5/2 TR split/Window type AC’s of any make and supply & fixing suitable new fan blade and testing & commissioning the unit.
M&L for taking down the damaged blower unit of any make split/Window AC and supply and fixing of new blower unit of suitable type and testing & commissioning the unit.
M&L for complete scraping out the crusting painting of the complete body of out door unit metallic surface, cleaning the surface thoroughly, apply putty / metal paste, prepare the surface, apply 2 coat of synthetic enamel paint over a coat of red oxide primer for 1.5 / 2TR capacity split type AC’s.
M&L for cleaning flushing the refrigeration system thoroughly with CTC, and Nitrogen gas, leak testing and locating the leaks, rectifying the leaks, by brazing the joints, replacing the damaged copper pipes, silver rod/ copper. Pressure testing, dehydrating, vaccumissing, gas charging testing & commissioning the system the work includes required strainer, N2 gas, Refrigeration gas and transportions Handling the unit. All as specified as directed by Engineer-in-Charge.
1.5 /2 TR Capacity
M&L for taking down the unserviceable temperature sensor probes and supply & fixing new sensor probe suitable for any type, make split/Window type AC’s and testing & commissioning.
M&L for taking down the defective unserviceable printed circuit Board and S/F of new printed circuit board for any make split/window type AC unit.
M&L for taking down the defective unserviceable sealed fan motor & S&F new fan motor of the same capacity & size to suit the split/window AC unit of any make and capacity of 1.5 / 2 TR all as per existing at site
M&L for taking down the damaged air filter set and S/F of new air filter set for split/window type AC’s of 1.5 / 2TR capacity.
M&L for taking down the defective unserviceable starting/ running capacitors 80/100 MFD 230V / 50Hz and supply and Fixing the new starting capacitor of the same capacity to split / window type AC’s and testing.
M&L for taking down the defective unserviceable starting relay and supply and fixing new rely suitable for 1.5/2TR Window / Split type AC’s and Testing.
M&L for taking down the defective unserviceable Thermostatic switch and S/F new thermostatic suitable for window type AC’s and Testing.
M&L for taking down the damaged drain pipe and S/F of new insulated drain pipe suitable for split type AC’s.
M&L for taking down the defective capillary tube set and supply & Fixing new suitable capillary set for split type AC’s.
M&L for taking down the rusted out door unit stand and supply & fixing the stand with required anchor fastner and nut & bolts and rubber bushes for 1.5 / 2 TR Split unit.
M&L for taking down the burned out door unit fan motor and rewinding, overhauling renewal of worn out shaft & bushes, and fixing to the unit, of 1.5 / 2 TR Split units.
M&L for taking down the defective remote control unit and S/F of new remote control unit for split/ window type AC of 1.5 / 2 TR of any make and testing.
M&L for taking down the defective definite purpose magnetic contactor of the split/window AC’s of any make, and supply & fixing of new contactor of 240 VAC. 30 Amps 50 Hz, and coil volt of 208/240V 50/60Hz and Testing.
M&L for taking down the defective unserviceable sealed motor of indoor unit of any make split unit of 1.5/2 TR capacity and S/F new fan motor suitable for Split type AC’s.
M&L for taking down the defective starting capacitor of split / window type AC’s and supply & fixing the new starting capacitor of 80/100 MFD 230V, 275SV-50Hz and Testing for 1.5/2TR AC Unit.
M&L for taking down the burned wiring kit and supply & fixing and testing of new wiring kit suitable for 1.5/2TR split and window type Ac unit.
M&L for taking down by disconnecting water connections and shifting elective water cooler to work shop, taking down the defective sealed compressor and replacing with new compressor, the work includes flushing the complete system condenser, cooling coil with Nitrogen, removal all carbon, oil & dirt, brazing & inter connecting the refrigeration lines, de-hydrating, purging with refrigerant, vaccumissing and charging of R22 / 134a Refrigerant and testing & commissioning and shifting to original location and connecting up the electrical & water connection for the following capacity water coolers. All as specified as directed by Engineer-in-Charge.
40/60/80 Ltrs. capacity water cooler
120/150 Ltrs. capacity water cooler
M&L for charging the water cooler of the following capacitor including taking down, transporting to workshop flushing out the cooling coil, condenser, brazing the refrigerant lines, replacing of liquid line copper strainer, leak testing, purging with refrigerant, vaccumissing and charging of R22/R 134a gas, testing & commissioning and shifting to the location and connecting up the electrical & water connection. All as specified as directed by Engineer-in-Charge.
a) 40/60/80 Ltrs. capacity water cooler
b)120/150 Ltrs. capacity water cooler
M&L for to the water cooler tank and cooling coil by dismantling the water cooler and carried out the lead soldering to cooling coil to the tank outer surface where ever the detached portion and rectify the leaks portion and re-assembly the water cooler of any capacity.
M&L for taking down the damaged thermal insulation of the water cooler, and renew the thermal insulation as per the existing thickness and assembling the body with necessary sheet metal screws etc., for any capacity water coolers.
M&L for taking down the defective starting relay and S/F of new starting relay for any capacity water cooler.
M&L for taking down the defective overload relay and S/F of new over load relay suitable for any capacity water cooler.
M&L for taking down the defective Running capacitor and Supply & Fixing new running capacitor 20/10 MFD, 440 VAC 50/60 Hz suitable water cooler.
M&L for taking down the defective starting capacitor and Supply & Fixing new starting capacitor 60/80 MFD, 230V, 270SU-50 Hz for water cooler upto 120 Ltrs. Capacity.
M&L for taking down the defective Running capacitor and Supply & Fixing new running capacitor of 25/36 MFD, 440 VAC, 50/60 Hz suitable for 150 Ltrs. Capacity water cooler.
M&L for taking down the defective thermostatic switch and Supply and Fixing of new thermostatic switch for water coolers.
S&F of Left/Punch cook for water cooler of any capacity.
S&F for float valve for water cooler of any capacity
M&L for taking down the damaged drain connections and drain pipe and S/F of new drain connection & pipe with necessary clamps, Nipple, coupling etc., for any capacity water cooler.
M&L for taking down the defective unserviceable sealed fan motor and S/F new fan motor with suitable capacitor for water cooler upto 40/80, 60/120 ltrs. Capacity.
M&L for taking down the damaged condenser fan blade and supply and fixing of new fan blade suitable for 40/60/80 water coolers.
M&L for taking down the corroded air cooler condenser and supply and fixing of new air cooled condenser with necessary brackets and fixing arrangements including welding brazing etc., for water cooling 40/60/80 Ltrs. Capacity.
M&L for taking down the complete corroded sheet metal body of out door unit of split unit and supply and fixing of new out door unit suitable 1.5 TR split unit the work includes dismantling the components and reassembly and fixing to the existing location and testing for any make of split unit.
M&L for taking down the corroded air cooled condenser and supply and fixing of new air cooled condenser suitable for 1.5 TR Split Ac
Material and Labour for complete carryout the servicing to Split/Window type AC’s including taking down from the position, dismantling the sheet metal parts, blowing out the dust, carryout the chemical cleaning to chocked cooling coil & condenser coil, by spray the dilated chemical cleaning agent, till remove complete chocking, flushing across the coils, cleaning all the sheet metal parts, filter, grill and fixing all the dismantled parts with sheet metal screws, lubricating the fan motor bush / bearing, checking all the electrical connections, renew any burned legs / clip and fixing back to position and testing.(Note: Gas Charging if required will be measured and paid seperately).
Supply and charging refrigerant R-22 complete one time for topping up or making full qty including plugging the leakage complete and as directed.
Supply and charging the refrigerator gas R-134A / R-34A /R-407/any environmental friendly refrigerant gas complete all as specified and as directed.
Supply and charging compressor oil suitable for AC's, water cooler ,Refrigerator and deep freezer complete including testing etc, complete all as specified and as directed.
Removing the old paint of the body of refrigerator of any capacity and making the body dent proof and preparing the surface and Painting the refrigerator with 2 coats of synthetic enameled paint of superior quality to match with existing paint with spray painting complete all as specified and directed.
S & Fixing in replacement Refrigirator of capacity 310 Ltrs complete
S & Fixing in replacement & commis-sioning of Metal Top Deep Freezer single phase 240 volt, 50 Hz of 300/320 Ltr including dismantiling of old unsv deep freezer of any size and depositing to MES Store yard
S&F in replacement of existing UNSV sealed Compressor unit for Refrigerator of capacity 165 to 185 Ltrs including Gas charging.
S&F in replacement of existing UNSV sealed Compressor unit for Refrigerator of capacity 285 to 320 Ltrs including Gas charging.
S&F in replacement of existing UNSV cooling Thermostat switch suitable for refrigerator/deep freezer of any capacity.
M&L for taking down the complete corroded sheet metal body of out door unit of split unit and supply and fixing of new out door unit suitable 1.5 TR split unit the work includes dismantling the components and reassembly and fixing to the existing location and testing for any make of split unit.
S&F AC single phase 10-60A Net Meter DLMS compiance of accuracy class 1.0, 240V 50 Hz, with backlit LCD, Optical port (measures Import KWh, Export kWh, net kWh, V,I,kW, 6 month history of Energy), with Rs232 Port including dismatling of existing meter and deposting it yto MES store Yard, making all necessary input and output connection of the new energy meter. Complete all as specified & directed.
Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.
M/s. Aggarwal Engineers
JAI DURGA CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .