Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.9 LAccepted-AOC P O WEST SRIPURIA DIST TINSUKIA ASSAM PIN 786 145 | TINSUKIA | ASSAM | 786145 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹25.3 L+₹1.4 L (5.84%)Rejected-Finance DINJAN TINALI P O DINJAN DIST DIBRUGARH ASSAM E 27 CWE DINJAN | DIBRUGARH | ASSAM | 785675 | L2 | Rejected-Finance Higher bid value | |
| 3 | L3₹26.4 L+₹2.5 L (10.4%)Rejected-Finance KAJANIBARI DINJAN PO DINJAN DIST TINSUKIA ASSAM786189 | DINJAN | TINSUKIA | ASSAM | 786189 | L3 | Rejected-Finance Higher bid value | |
| 4 | L4₹26.7 L+₹2.8 L (11.8%)Rejected-Finance NO 1 RANGAJAN VILLAGE PO BOKULONI CHARIALI MAUZA TIPLING SUB DIVISION TENGAKHAT DIST DIBRUGARH ASSAM 786191 | DIBRUGARH | ASSAM | 786191 | L4 | Rejected-Finance Higher bid value | |
| 5 | L5₹27.6 L+₹3.7 L (15.7%)Rejected-Finance P O WEST SRIPURIA DIST TINSUKIA ASSAM PIN 786 145 | TINSUKIA | ASSAM | 786145 | L5 | Rejected-Finance Higher bid value |
Tender Value
₹23.3 L
EMD Value
₹46,600
Closing Date
25 Aug 2022, 6:00 pmClosed
GE DINJAN
GE DINJAN, PANITOLA (PO), DIBRUGARH (DIST), ASSAM
SPECIAL REPAIR TO TOILET AND BATHROOM IN BLDG NO. P-42, 43 AND 44 (OR LIVING ACCN) OF 103 ENGR REGT AND CERTAIN MINOR WORKS UNDER GE DINJAN
2022_MES_543435_1
C/8470/E8
Open Tender
Civil Works
Item Rate
180 days
DINJAN MIL STN
AS PER TENDER DOCUMENT
9 documents required · 9 mandatory
₹500
GE DINJAN
₹46,600
Yes
17 Sept 2022
4 Aug 2022
27 Aug 2022
4 Aug 2022
25 Aug 2022
18 Aug 2022
Amount
Surface dressing not exceeding 15 cm deep and getting out in soft/loose soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, or for shafts, wells, cesspits, manholes, pier holes, or laying of cables, poles, etc area not exceeding 10 Sqm on plan and getting out in soft/loose soil complete all as specified and as directed.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and as directed.
Removal of surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above starting point complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed.
Taking down chowkhats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutters from the frames) complete all as specified and as directed
Demolition of brickwork or stone/ boulder masonry, built in Cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlars facings, dressed stonework and precast concrete articles complete all as specified and as directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed
Dismantling 100mm internal dia of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required complete all as specified and as directed.
M&L for hardcore of brocken stone/brick of gauge not exceeding 63 mm, deposited, spread, and leveled in layers not exc 15 cm thick, watered and rolled / rammed to a true surfaces complete all as specified and as directed.
M&L for PCC type D2 (1:4:8), (using 40mm graded broken stone aggregate) as in foundations, filling and mass concrete, sub base of floor pole etc complete all as specified and as directed.
M&L for 100mm thick PCC type C2 (1:3:6), (using 40mm graded crushed stone aggregate) as in sub base etc complete all as specified and as directed.
M&L for 75 mm thick, plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in plinth protection/ hard standing etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand (1:2) complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete all as specified and as directed.
M&L for 15 mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar (1:6) including finished the surface even and smooth without using extra cement complete all as specified and as directed.
M&L 15 mm thick rendering on other than fair faces of brick work or concrete surfaces in cement mortar (1:4) including finished the surface even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 5 mm thick in cement mortar (1:3) on concrete surfaces as in ceilings (sunshed, chajja etc) and finishing surfaces even and smooth without using extra cement complete all as specified and as directed.
M&L for coloured glazed ceramic tiles of size 350x250x7mm / 450x 350 x 7 mm thick in vertical surface (such as dado/ skirting/ and facia of side bldg) jointed in neat cement slurry and pointed in white or colour cement to match including over 10 mm thick back coat of cement mortar in (1:4) complete all as specified and as directed.
M&L for non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed or bedding layer of cement mortar in (1:6) for laying floor finishes complete all as specified and as directed
M&L for non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed or bedding layer of cement mortar in (1:6) for laying floor finishes complete all as specified and as directed
M&L for chequered cement concrete tiles of size 25cm x 25cm x 22mm thick, as in floors etc, and set & jointed in neat cement slurry and pointed in grey cement and pigments to match with the shade of tiles including 15 mm thick screed bed in cement mortar (1:6) complete all as specified and as directed.
M&L for preparation of new plastered surfaces and applying three coats of white wash on ceiling complete all as specified and as directed.
M&L for preparation of old plastered surfaces and applying one coat of white wash on ceiling complete all as specified and as directed.
M&L for preparation of new plastered surfaces and applying three coats of white wash on wall complete all as specified and as directed.
M&L for preparation of new plastered surface of walls etc and applying two coats of cement base paint over alkali resistant priming paint including complete all as specified and as directed.
M&L for preparation of old decorated plastered or unplastered surfaces of wall cornices etc by brooming down or steel wire brushing, scraping down, the surfaces covered by smoke soot, growth of moulds and moos, efflorescent, having oil and greases spots and applying one coat of cement base paint (white or tinted) complete all as specified and as directed.
S&F for 4 mm thick figured glass, pin head type and glazing with oil putty in squares exceeding 0.5 sqm in each pane complete all as specified and as directed.
S&F in repairs galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed.
S&F for anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
S&F for anodised aluminium window and ventilator shutters with frame, fixed type, without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc including 5mm thick, tinted sheet glass & aluminium anodised handle, tower bolt of suitable size, etc complete all as specified and as directed.
S&F for factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing complete all as specified and as directed.
S&F for factory made solid panel PVC door shutter, 30 mm thick (style) consisting of frame, made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing in SSR Part II 2020 complete all as specified and as directed.
S&F for 100mm long butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and as directed.
S&F for 200 mm long, aluminium anodised barrel tower bolts of extruded section complete all as specified and as directed.
S&F aluminium handle 150 mm long cast type, anodised extruded fabricated type complete all as specified and as directed.
M&L for rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of capacity 1000 ltrs hoisted and fixed in position all as specified in SSR Part-1 including dismantling water tank and removing to store complete all as specified and as directed.
S&F in repair 20 mm bore dia of pipe, Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 20 mm - 210 gms) complete all as specified and as directed.
S&F in repair 20 mm bore, gun metal, gate valve with iron wheel head, screwed both ends for iron pipes and fixed complete all as specified and as directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exceeding 10 cm but not exceeding 20 cm girth complete all as specified and as directed.
S&F in repair 15 mm bore dia bib taps, chromium plated cast copper alloy, fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F in repair 15 mm bore dia stop valves (concealed type), chromium plated cast copper alloy, fancy type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F in repair 15 mm bore dia pillar taps, chromium plated, cast copper alloy, fancy type, with capstan heads, screwed down high pressure, with or without lettered 'Hot' or cold with long screwed shanks and fly nuts screwed for iron pipe complete all as specified and as directed.
S&F for PVC connections 15mm size with PTMT nuts of length 450 mm long complete all as specified and as directed.
M&L for 75 mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement including disconnection of old existing trap, and connected with existing water pipe complete all as specified and directed.
S&F for 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
S&F for 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall complete all as specified and as directed.
S&F for 110 mm bore PVC (SWR) bends any radius complete all as specified and as directed.
S&F for 110 mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and as directed.
S&F for 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
S&F for 75 mm bore PVC (SWR) bends any radius complete all as specified and as directed.
Drilling and tapping cast iron water mains (in position) for branch connections of the internal dia of 20mm bore GI pipe complete all as specified and as directed.
Supply and laying, CPVC pipe of 20mm outer dia, SDR 11& Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. tranches complete all as specified and as directed.
Supply and laying, CPVC pipe of 25mm outer dia, SDR 11& Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. tranches complete all as specified and directed.
Supply and laying, CPVC pipe of 32mm outer dia, SDR 11& Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. tranches complete all as specified and directed.
S&F for PVC low level flushing cistern, 10 liter capacity, valveless, symphonic action type with inlet, ball valve, float and handle incl bracket, PVC connection pipe and flush pipe of polyethylene of low or high density complete all as specified and as directed.
S&F for vitreous china squatting pan Orissa pattern of size 580mmx440 mm white, with integral foot rests connected with 'P' or 'S' trap (excluding flushing cistern and flush pipe) and provn of lime concrete bedding complete all as specified and as directed.
S&F in repair vitreous china wash hand basin white flat back size 550x400mm excluding taps, waste chain and plug and porcelain stopper including cutting for and pinning in ends of brackets or erecting stand (exclusive of fixing of supply and waste pipe) complete all as specified and as directed.
S&F in repair vitreous china bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), (excluding flushing cistern, flush pipe and waste pipe) including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe (exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and as directed.
M&L for precast cement concrete (1:2:4), type B1, (using 20 mm graded aggregate) as in landings, cover slabs of manhole, septic tank etc, and similar articles with plain faces set in cement mortar 1:4 including necessary formwork, moulds etc and incl taking out/removal of existing unserviceable cover slab from manhole /septic tank complete all as specified and as directed. Note : Reinforcement shall be measured and paid separately.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Cleaning of manholes of any type including taking out accumulated semiliquid, sludge and other deposits such as broken bricks , silt etc from manholes of depth not exceeding 1.5 m, and removing the same to a distance not exceeding 50 m and burried under ground (minimum 30 cm below ground level) including necessary excavation of pits in soft / loose soil and returning, filling in including sprinkling of bleaching powder at the rate of 0.20 kg/Sqm and dressing of surplus soil around to slope, complete all as specified and directed. Note : (i) Volume of Manholes cleaned shall be measured for payment purpose. (ii) Depth of foul water and effluences including night soil, excreta, sludge, etc shall be measured before commencement of dewatering/ cleaning of Septic tank in presence of Engr-in-Charge.
Cleaning of blocked drain pipes (SGSW/hume pipe) up to 150 mm bore by rodding from manholes and well flushing with water after cleaning the same and disposing off the deposited sludge, etc obtained from inside pipes to a distance exceeding 50m but not exceeding 200m burried under ground (minimum 30 cm below ground level) including necessary excavation of pits in soft/loose soil and returning, filling in including sprinkling of bleaching powder at the rate of 0.20 kg/Sqm and dressing of surplus soil around to slope complete all as specified and as directed.
Taking down carefully unserviceable aluminium/copper point wiring (light, fan, socket or power) complete, (fitting such as switches, ceiling roses, pendants, regulators, sockets, etc to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed.
M&L for concealed point wiring complete with 1.5 sqmm FRLSH, PVC insulated multi stranded copper conductor single core cable 1100 volts grade, drawn into non metallic PVC rigid conduit medium grade of 20mm dia and conduit accessories and fittings like bend, elbows, crosses wall crossing etc. including cutting, chasing and pinning fixed on wall, floor, roof and including provision of PVC insulated FRLS 1.5 sqmm copper conductor for earth continuity and connected to common earth dolly and modular metal flush boxes concealed in wall and modular cover plate with frame for housing the switches socket outlet, fan regulator etc, including testing on completion for one light/ fan point/ bell buzzer point controlled by one way 6 Amp modular switch complete all as specified and as directed. Note : Cost of PVC conduit, cover plate and box of suitable module, cutting chases of wall, making good disturbed wall surfaces including finishing with cement mortar (1:4) matching with existing colour/paint of surface are deemed to be included in the quoted rate.
All as per item No. 65 above but wiring with cables of size 2.5 sqmm & cables of size 2.5 sqmm as continuous earth wire for one 3 pin socket outlet, 5/15 Amps on Independent board complete all as specified and as directed.
S&F for switch piano, 5 Amp single pole, flush type one way 230 volts bearing ISI marked complete all as specified and as directed.
S&F for switch socket combination, 2 in 1, 5/16 Amps, 240 volts, bearing ISI marked flush type complete all as specified and as directed.
S&F for ceiling rose, 3 phase/PVC/polycarbonate, isolated body bearing ISI marked and including PVC box complete all as specified and as directed.
S&F in repair lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
S&F in repair LED bulb of 9 Watt complete all as specified and as directed. Make : Havells /Philips/Bajaj.
S&F for 20 watt, surface and wall mounting type LED batten with polycarbonate housing & integrated complete all as specified and as directed. Make : Havells/Philips/Bajaj/Crompton/Century.
S&F for 09 watt, surface and wall mounting type LED batten with polycarbonate housing & integrated complete all as specified and as directed. Make : Havells/Philips/Bajaj/Crompton/Century.
S&F in repair factory made board distribution (DB) double door in sheet steel enclosure with common bus bar at incoming end, SPN, 8 way, 240 Volts suitable for housing MCBs including complete all as specified and as directed.
S&F for MCB, SPN, 240 Volts, 6 to 32 Amps, 'C' Series, breaking capacity 10KA complete all as specified and as directed.
S&F for MCB, 'C' Series, single pole, 240 Volts, 6 to 32 Amps, 'C' Series, breaking capacity 10KA capacity complete all as specified and as directed.
Taking down sub main wiring/service connections of any size with conduit/casing caping complete including removal from site and making good disturbed surface of walls/floors etc complete all as specified and directed.
M&L for concealed sub main wiring with two run of 6 Sqmm (nominal area) single core cable PVC insulated, multistranded, unsheathed, copper conductor cables (FRLSH), 1100 Volts grade drawn through PVC conduit of suitable size, fixed to wall/ceiling etc including one run of 6 Sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor (FRLSH) as earth wire and duly connected to common earth point complete all as specified and as directed. Note : (a) PVC Casing-caping/conduit, two run wiring cables and one run of earth wire will be measured as one length. (b) All incoming and outgoing cable shall be connected by using proper lugs & sockets.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to 4mm GI wire by means of bolts and nuts checknuts and washers protected by 20mm bore galvanised iron light grade pipe, funnel with 40mm bore GI medium grade pipe for watering, wire mesh including concrete pit PCC 1:3:6 type C1, precast RCC 1:2:4 type B1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @ 150 mm centre to centre in both direction and 10mm dia MS handle of suitable size, charchole or coke and salt in alternative layers, including necessary excavation and earth work in any type of soil, all as specified and shown in electrical plate no 3 of SSR part-1 complete all as specified and directed and tested on completion.
M&L for test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm, drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw including taking down old unserviceable complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm, 3.5 core complete all as specified and as directed.
M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the UG cable laid in trenches) of 23cm spread thick ness and consolidated (punned) upto 18cm thickness, complete all as specified and as directed. Note : For the purpose of payment, punned thick-ness of sand cushioning only shall be measured and paid for.
S&F Sub-class B brick, well burnt, laid breadth-wise along the axis of cable laid in trenches over sand cushion laid for UG Cable protection, complete all as specified and as directed.
S&F for 25 Watt LED building security light new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING separate driver compartment with IP65 protection and impact resistance of IK07 complete all as specified and as directed. Make : Havells/Philips/Bajaj.
Taking down exhaust fan any size and capacity in safe custody and refixing it after minor repair complete all as specified and as directed.
Taking down main switch /MCB /defective/unserviceable switch fuse unit/ DBs of any capacity by disconnecting the electric supply incl MCB/MCCB/ Cut out etc any type any size complete all as specified and as directed.
G S Enterprises & Co
M/S CHANDAN ENTERPRISE
M/S SINGH TRADERS
M/S BORAH BROTHERS
M/S CHAKRA GOHAIN
M/S A K BROTHERS
jitendra narayan goswami
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .