Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 LAccepted-AOC NAGLA UDHA NEAR PRIMARY SCHOOL POST DHANOLI AGRA UP AGRA 282010 | AGRA | AGRA | UP | 282010 | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹15.4 L+₹4.5 L (41.6%)Rejected-Finance 15 15 KHERIYA BHAN PURANI CHAWANI GWALIOR GWALIOR GWALIOR MADHYA PRADESH 474010 | GWALIOR | MADHYA PRADESH | 474010 | L2 | Rejected-Finance Other then lowest tenderer | |
| 3 | L3₹16.5 L+₹5.6 L (51.6%)Rejected-Finance | L3 | Rejected-Finance Other then lowest tenderer | |
| 4 | L4₹16.6 L+₹5.7 L (52.6%)Rejected-Finance | L4 | Rejected-Finance Other then lowest tenderer | |
| 5 | L5₹16.6 L+₹5.7 L (52.7%)Rejected-Finance 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | L5 | Rejected-Finance Other then lowest tenderer |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
22 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Adm Area Agra
GE (AF) Adm Area Agra 282008
REPAIR AND MAINT TO STREET LIGHTS BUS BAR BOXES AND OTHER CONNECTED WORK IN 4 AREA AND MAP PHASE II UNDER GE AF ADM AREA AGRA
2021_MES_447149_1
8000-1870/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF Station Agra
Class E
cat b i
8 documents required · 8 mandatory
₹500
GE AF Adm Area Kheria Agra
₹40,000
Yes
14 Jul 2021
31 May 2021
24 Jun 2021
31 May 2021
22 Jun 2021
10 Jun 2021
31 May 2021 - 8 Jun 2021
60 days
Amount
Taking down street light fitting any type any wattage from street tubular/PCC Poles/High mast poles of any height incl disconnection of electrical connections repair the same complete in all respect, refixing and reconnection at existing/new position all as spd and directed.(all UNSV accessories shall be replaced under respective items).
Supply and fixing of driver suitable for LED light fitting 15 to 30 Watt complete all as directed.
Supply and fixing of driver suitable for LED light fitting 45/60 Watt. complete all as directed.
Supply and fixing of driver suitable for LED light fitting 90/120 Watt. complete all as directed.
Supply and fixing of PCB card suitable for LED light fitting 15 to 30 Watt. complete all as directed.
Supply and fixing of PCB card suitable for LED light fitting 45/60 Watt. complete all as directed.
Supply and fixing of PCB card suitable for LED light fitting 90/120 Watt. complete all as directed.
Material and labour for replacement of existing unsv street light fittings with LED street light fitting 45 Watts, IP 66, having pressure die cast alumnium alloy housing with heat resistant toughned glass with individual LED lenses and Driver shall be IP-67 for water protection, including surge protection device 5 KV including making connections with PVC insulated and sheathed three core multi stranded aluminium conductor cable of size 2.5 Sqmm complete all as specified and directed. Make: Havells Cat Ref ENDURAPEARLNEOSL45WLED757PASYTOPC/ Philips Cat Ref BRP409 LED 040 CW HO MR FG S1 PSU GR/ Wipro Cat No: LR02-501-XXX-57-XX
Material and labour for replacement of existing unsv street light fittings with LED street light fitting 60 Watts, IP 66, having pressure die cast aluminium alloy housing with heat resistant toughned glass with individual LED lenses and Driver shall be IP-67 for water protection, including surge protection device 5 KV including making connections with PVC insulated and sheathed three core multi stranded aluminium conductor cable of size 2.5 Sqmm complete all as specified and directed. Make: Havells Cat Ref ENDURAPEARLNEOSL60WLED757PASYTOPC/ Philips Cat Ref BRP409 LED 060 CW HE NR PC S1 PSU GR/ Wipro Cat No :LR02-671-XXX-57 G2.
M&L for replacement of existing unsv street light fittings with LED street light fitting 90 Watts, IP 66, having pressure die cast aluminium alloy housing with heat resistant toughned glass with individual LED lenses and Driver shall be IP-67 for water protection, having surge protection device 10 KV, including making connections with PVC insulated and sheathed three core multi stranded aluminium conductor cable of size 2.5 Sqmm complete all as specified and directed. Make: Havells Cat Ref ENDURAPEARLPLUSSL90WLED757PASYTOPCAS THO/ Philips Cat Ref BRP410 LED 091 CW HE MR PC S2 PSU GR/ Wipro Cat No:LR02-102-XXX-57-G2
M&L for replacement of UNSV GI bracket made out of GI pipe 40 mm bore medium grade bent to required shape of 0.90 mtr long and fixing to pole/wall with suitable size of nut, bolts and clamps all as spd and directed. Note :- Taking down and re-fixing of Street light shall be the part of this item.
S & F in replacement post top lantern 35 Watts, 230 volts, 50 Hz with IP65 protection, mushroom or oval shaped in opal/ prismatic finish made out of polycarbonate, suitable all accessories and prewired complete all as spd and directed. Make:- Havells Cat Ref RUBYPT35WLED830PSYMTOPC/ Wipro Cat Ref LP07-431-XXX-57-CL or equivalent to Phillips.
S & F in replacement LED bollard of 9/10 watts, 230 volts, 50 Hz with IP 65 protection with robust design and efficient light distribution complete all as spd and directed. Make:- Havells Cat Ref MOUNTBL 10WLED857PSYMTOPMMA(0.6M)/ Wipro Cat Ref LB14-131-XXX-65-05/ Phillips Cat Ref BCP400 LED09 D CW PSU GR S1
M&L for replacement of existing unsv street light fittings with LED flood light fitting 120 Watts, IP 66, having pressure die cast alumn alloy housing with heat resistant toughned glass with individual LED lenses, having surge protection device 10 Kv and Driver shall be IP-67 for water protection, including making connections with PVC insulated and sheathed three core multi stranded alumn conductor cable of size 2.5 Sqmm complete all as specified and directed. Make: Havells Cat Ref JETAIRISFLS120WLED757APNBLTG/ Phillips Cat Ref BVP192 LED110 CW HO NB FG GR PSU/ Wipro Cat Ref LF20-132-060-57-G2
M&L for replacement of existing unsv street light fittings with LED flood light fitting 150 Watts, IP 66, having pressure die cast alumn alloy housing with heat resistant toughned glass with individual LED lenses, having surge protection device 10 Kv and Driver shall be IP-67 for water protection, including making connections with PVC insulated and sheathed three core multi stranded alumn conductor cable of size 2.5 Sqmm complete all as specified and directed. Make: Havells Cat Ref JETAIRISFLS150WLED757PSYMLTG/ Phillips Cat Ref BVP122 LED150 CW HE NB FG XTFCL S4/ Wipro Cat Ref LF20-192-060-57-G2
Excavating in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation etc or for laying for cables etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any type of soil including removal of sand, bricks/PCC covers laid for cable proection complete all as specified and directed.
Returning, filling in, trenches including spreading, levelling, watering and well ramming in layers not exc. 25cm in any type of soil complete all as specified and directed.
Removing surplus excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
M&L for local sand cushioning with dry and clean over and under the cable for protection of cable, 80 mm sand laid before laying the cable 150 mm sand after laying the cable and punned down complete all as directed
Material and labour for old size sub class 'B' bricks well burnt, laid flat as in cable protection complete all as specified and directed.
Re-laying of old serviceable bricks item retreived from Sl No.16 here-in before for cable protection cover laid flat and dry in trenches over the cable prependicular to the direction of cable all as directed.
Taking out old unserviceable LT UG cables of size 10 to 70 Sq mm 2/3.5/4 Core from trenches, poles/walls and floor for removing of fault or re-laying (Necessary earth work shall be measured and paid under respective item of sch.) complete all as directed.
Re-Laying XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of 10 to 70 Sqmm 3.5/4 Core (Item retreived from item 05 here-in-before) laid in trenches or fixed on wall/floor/poles after removing fault complete all as specified and directed.
S&L XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 50 Sq mm 3.5 core laid in trenches or fixed on wall/floor/poles complete all as specified and directed.
All as per Srl Item No 24 here-in-before but size of cable 35 Sqmm 3.5 Core complete all as spd and directed.
All as per Srl Item No 24 here-in-before but size of cable 25 Sqmm 3.5 Core complete all as spd and directed.
All as per Srl Item No 24 here-in-before but size of cable 16 Sqmm, 4 Core complete all as spd and directed.
All as per item No 24 here in before but size 10 Sqmm 4 core complete all as spd and directed.
S&L/ fixing to wall/hanger in replacement of unsv 1100 volts grade heavy duty PVC insulated aluminium conductor, served with inner sheathing of PVC in service connections suspended by insulating hangers not more than 1 mtr apart including 4mm suspension wire one twin core cable of size 16 Sqmm multi -strand complete all as specified and directed .
Material and labour for replacement of GI tubing light grade 40 mm bore for passing through cables laid under the floor, along the wall or along the pole complete all as specified and directed .
Material and labour for replacement of GI tubing light grade 50 mm bore for passing through cables laid under the floor, along the wall or along the pole complete all as specified and directed .
Supply, erecting and fixing in true vertical position, steel tubular swaged pole (410 SP – 31), 09 meter long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be painted with two coats of aluminum paint from 1.5 mtr above ground level to top of pole and a height of 1.5 mtr from the ground level synethetic enamel paint in alternate strips / layer (30 cm wide) with white and blue colour including writing the pole number in white letters on black background including taking out old unsv pole complete all as specified and directed.
Material & Labour PCC 1:4:8 type D2 ( using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
Material & Labour PCC1:3:6 Type C2 (using 40mm graded stone aggregate) as in coping of poles etc. complete all as specified and directed.
Trimming up of tree branches upto 3 mtr all around LT overhead lines, removing cut branches from site as directed. Note :- (i) The overhead lines will be kept clear from all trees by trimming of tree branches with 3 mtr all around the line. (ii) Necessary permission will be obtained from department by contractor one day prior to trimming in particular area and shut down of that area will be arranged by department.
M&L for prepration of old painted surface of steel tubular poles of 9 mtr long including cross arms, cable protection pipe, bus bar box and painting of complete area with one coat of aluminum paint from 1.5 mtr above ground level to top of pole and a height of 1.5 mtr from the ground level synethetic enamel paint in alternate strips / layer (30 cm wide) with white and blue colour including writing the pole number in white letters on black background and cleaning /cutting the grass/bushes at a radius of 2 mtr surrounding the pole all as directed.
M&L in replacement of existing unsv MCCB 160 Amps current carrying capacity 36 KA , AC 415 Volts four pole with magnetic/ thermal fixed setting complete all as specified and directed.
M&L in replacement of existing unsv MCCB 125 Amps current carrying capacity 36 KA , AC 415 Volts four pole with magnetic/ thermal fixed setting complete all as specified and directed.
M&L in replacement of existing old un-serviceable fixed type MCCB with MCCB 63 amps, 4 pole, 415 volts, 16 KA complete all as specified and directed.
Supply and fixing in replacment of nature switch complete with timer, contactor, relays and suitable rating MCBs for incoming and out going in built in suitable IP 66 enclosure (Hensel) of three phase integrated models of capacity 8 KW complete all as specified and directed.
All as per item No. 40 above but of single phase integrated models of capacity 8 KW
Supply and fixing thermoplastic polystyrene /polycarbonate enclosure bus bar chamber, shock proof, vermin proof and dust proof complete with 04 Nos aluminium strip of capacity 100 amps including non metalic clamps and GI nut bolts and washers of suitable size and fixed on pole / wall complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth pit not less than 3.25 mtr deep below the normal ground level) with top edge of plate not less than 2.5 mtr below the normal ground level connected to galvanized earth strip 32X6mm thick by means of nuts, bolts, washers and check nuts of galvanised iron or steel and welding full length of strip with earth plate, 40 mm bore GI pipe light grade proection pipe up to test point, 20mm dia light grade GI pipe for watering, meshed funnel, alternate layer of charcoal and common salt complete all as per SSR with PCC chamber, 50mm thick RCC cover in 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 8mm dia TMT bar @ 80mm c/c both way in lieu of CI pit cover and protection including necessary excavation and earth work complete all as specified and directed.
M & L for making service connection from MCB DB to LED flood light fitting of high mast with PVC sheathed 2.5 sqmm twin core multi-stranded aluminium conductor cable of required length complete all as specified and directed.
M&L for drilling suitable dia horizontal bore holes for insertion / laying of up to 50 mm bore GI tubing of any description below/under road surface/floors etc. with using mechanical or manual devices as required at site including making good disturbed surface to match with the existing streta after laying pipes complete all as specified and directed.
S&F in repair MCB single pole 240 volts, 'C' curve of rating from 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
S&F in repair MCB SPN 240 volts, 'C' curve of rating from 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
AUTOMATION AND SWITCHGEAR PANELS
Balaji Associate
SHOURYA ENGINEERING ENTERPRISES
Unnati Engineers
G S SANDHU & CO.
M/s S.M. Construction
CHAHAR CONTRACTOR AND SUPPLIERS
C P Singh and Co
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .