Loading…
Loading…
Tender Value
₹2.3 Cr
EMD Value
₹4.6 L
Closing Date
5 Oct 2026, 1:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
NIT
15 conditions · 4 needing a document upload
As per PREAMBLE CLAUSE No. 11.2 of Tender Document:- The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V=Advertised value of the tender in crores of Rupees, N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
ELECTRICAL CONTRACTORS LICENSE:- The contractor shall fulfill valid Electrical Contractor License requirement as per IE Rule 1956 clause no- 45. Electrical Contractors license shall be submitted along with the offer, failing which the offer will summarily be rejected.
Technical Eligibility Criteria: As per clause 11.1 of Preamble and Scope of Work of uploaded tender document Page no. 4 & 6.
SIMILAR NATURE OF WORK: The contractor should have executed: "Repair/Rehabilitation/Overhauling/ AMC/ Supply, erection, testing and commissioning of Central AC unit/ Window AC /Package AC units / Air conditioning duct / Split type AC units / Water coolers etc."
23 conditions · 9 needing a document upload
All the supporting DOCUMENT(S)/CERTIFICATE(S) of as a proof Technical and Financial credentials as detailed in this tender Document, has/have been attached.
Supporting DOCUMENTS/CERTIFICATES as detailed in this Tender Document has been attached.
The Bid Security shall be deposited either in cash through e payment gateway or submitted as Bank Guarantee bond from a scheduled commercial bank of India or as mentioned in tender documents. The Bank Guarantee bond shall be as per Annexure- VIA and shall be valid for a period of 90 days beyond the bid validity period. The original Bank Guarantee should be delivered in person to the official nominated as indicated in the tender document before closing date for submission of bids. (i.e. excluding the last date of submission of bids.) (See clause 1.10 of Chapter-I of Tender Document)
All the bidders / tenders should ensure that they are GST compliant and their quoted tax structure / rates are as per GST Law. (Copy of GST registration certificate)
Copy of PAN CARD
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Replacement of over aged Industrial ACs, Window AC, Split AC with Energy Efficient VRF AC Plant, 16 nos 2 TR split AC units with VRF AC plant and Refrigerators in RRI, ORH, UTS, PRS office Cuffe Parade, Colaba.
BB-LG-W-CSMT-2026-09~CR
BB-LG-W-CSMT-2026-09
Open
Works - General
12 Months
Mumbai, Maharashtra
₹0
₹4.6 L
11 Sept 2026
11 Sept 2026
21 Sept 2026
113 items across 3 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 81,48,765.69 | ||
| — | Breakup | for details. | — | ||
| (1) Supply, Lifting, Shifting, Erection, Installation, Testing and Commissioning of Outdoor Units of VRF system with Air-cooled condenser suitable for operation at ambient temp upto 56°C, high pressure Scroll Compressors with hermetic motor, assembled and wired in a single package complete, starting controls, safety controls, operating controls and with full feature microcomputer based controller with programming/diagnosis facility. One/All Compressors shall be invertor type based on manufacturer's technology. The system should deliver rated capacity at ambient upto 43°C DB. (a) 5 HP Outdoor Unit(b) 10 HP Outdoor Unit | — | — | — | 28,84,142.52 | |
| — | Breakup | for details. | — | ||
| (2) Supply, Lifting Shifting, Installation, Testing and Commissioning of Indoor Units suitable for VRF System with Necessary Control Instrument.(a) 2.0 TR hi-wall indoor units | — | — | — | 9,06,299.6 | |
| — | Breakup | for details. | — | ||
| (3) Supply, erection, testing and commissioning of Ref joints for Indoor Units | — | — | — | 2,56,040.4 | |
| — | Breakup | for details. | — | ||
| (4) Supply, erection, testing and commissioning of Hard Copper refrigerant piping of suitable sizes for pair of gas (suction) & liquid, with 19/13mm Closed Cell Insulation for Wrapping the copper pipe lines. The Piping system must be supported at specific distance. | — | — | — | 9,96,012 | |
| — | Breakup | for details. | — | ||
| (5) Drain piping in hard PVC with all fittings, supports and clamps. The piping shall be suitably insulated with 9mm thick closed cell foam Class O (Nitrile Rubber) stuck with approved adhesive compound. (25/50mm dia as per site requirement) | — | — | — | 1,44,032 | |
| — | Breakup | for details. | — | ||
| (6) Supply and laying of communication cable 2 core 1 sq.mm shielded copper armoured | — | — | — | 42,522 | |
| — | Breakup | for details. | — | ||
| (7) Wiring of concealed 15 Amps 6 pin wall socket point complete on separate switch board with 20 Amp DP RCBO & all accessories and running earthing copper conductor as per standard practice. The switches shall be of modular type. | — | — | — | 77,792.8 | |
| — | Breakup | for details. | — | ||
| — | Breakup | for details. | — | ||
| (9) Supply of cordless remote controllers | — | — | — | 34,416.8 | |
| — | Breakup | for details. | — | ||
| (10) Supply and laying of GI perforated cable tray of size 300 mm x 50 mm x 2 mm Thick. | — | — | — | 2,82,004 | |
| — | Breakup | for details. | — | ||
| — | — | — | 4,17,063.63 | ||
| — | — | — | 7,90,679.2 | ||
| — | Breakup | for details. | — | ||
| (15) Supply, erection, testing and commissioning of maintenance free earthing | — | — | — | 2,12,568.16 | |
| (16) Supply & erection of earthing G.I. pipe with cement concrete earth chamber, charcoal, salt, etc. | — | — | — | 50,566.08 | |
| — | Breakup | for details. | — | ||
| (17) Supply, erection, testing and commissioning of GI strip of 25 mm x 5mm | — | — | — | 1,12,320 | |
| — | — | — | 1,05,01,202.68 | ||
| — | Breakup | for details. | — | ||
| (1) Supply, erection, testing and commissioning of Industrial type 3 pin 230 V socket with 20 A DP MCB with metal enclosure as per site requirement | — | — | — | 37,283.04 | |
| — | Breakup | for details. | — | ||
| (2) SETC of Wall mounted Air Conditioner of capacity 4.0 TR (2.0 TRx2 nos) (Twin type) indoor and outdoor suitable for Ambient temperature 43°C and 24x7 working of S&T installation as per detailed specification | — | — | — | 60,46,805.7 | |
| — | Breakup | for details. | — | ||
| (3) Supply, erection, testing and commissioning of refrigerant piping of size 5/8" or 1/2" copper and 1/4" or 3/8" copper made with insulation and 4 core 2.5 sq.mm copper wire and covered with PVC trunking of suitable size. | — | — | — | 8,04,928 | |
| — | Breakup | for details. | — | ||
| (4) Supply, erection, testing and commissioning of PVC pipe of 25/50 mm for drainage of condensate water. | — | — | — | 12,852 | |
| — | Breakup | for details. | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderBookofACs.pdf
ATTACHMENT
GCCApril2022.pdf
ATTACHMENT
GCCACS1to12.pdf
ATTACHMENT
CheckListac.pdf
ATTACHMENT
SpecificationEarthingRDSOSPN197Ver1.pdf Maintenance Free Earthing
ATTACHMENT
SpecificationEarthingRDSOSPN197Ver1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .