Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.3 LAdmitted-Finance | ₹12.3 L | L1 | Admitted-Finance |
| 2 | L2₹12.5 L+₹16,090.48 (1.30%)Admitted-Finance | ₹12.5 L+₹16,090.48 (1.30%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S CHAITANYA CONSTRUCTION CO. L1 | CHANDERA BUILDERS L2 |
|---|---|---|---|---|---|
| 1.01 | Dismantling of electric connection from panel and motor, pump and motor from coupling, motor and pump removed from base frame. Removing suction and delivery lines, sluice valves, NRV, old damaged MS base frame from foundation etc by electric cutter, gas cutter, tools and tackles, manual labour and shifting the same to JE store. | 2 | Jobs | 23,100 ₹27,258 Lowest | 23,300 ₹27,494 |
| 1.02 | Breaking of existing RCC foundation by manual means including manual tools or electric demolition hammer as per site requirement including digging upto 50 cm for laying the new foundation and disposing off malba as per instructions from engineer – in – charge within 1 km of radius from site. | 2 | Job. | 10,900 ₹12,862 Lowest | 11,000 ₹12,980 |
| 1.03 | Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump including form work and finishing etc as required as per site requirement. | 2 | Job. | 54,800 ₹64,664 Lowest | 57,700 ₹68,086 |
| 1.04 | Providing and fixing of MS base frame as per site sample and directions of engineer in charge for 60 HP motor and pump set. | 2 | Job. | 32,300 ₹38,114 Lowest | 33,700 ₹39,766 |
| 1.05 | S/o Horizontal split casing Centrifugal pump with impeller (CI), neckring (Bronze) and casing (CI) shaft and sleeve (SS-410) in fitted condition with suitable bearings with head 42 m and discharge 346 m3/ hr, RPM- 1480, suction/ delivery size: 200 mm / 150 mm, rated input: 60 HP equivalent to SCP 150/390 HA of M&P make. Make: Wilo Matter and Platt, KBL, DJB approved make | 2 | Nos | 7,09,300 ₹8,36,974 Lowest | 7,09,400 ₹8,37,092 |
| 1.06 | Supply of M.S. Pipe 200 mm, 6 mm thick make Jindal / tata / DJB approved make | 7 | mtr. | 9,450 ₹11,151 Lowest | 9,506 ₹11,217.08 |
| 1.07 | Supply of M.s. pipe 150 mm, 6 mm thick. Make: Jindal / Tata / DJB approved make | 2 | mtr. | 4,200 ₹4,956 Lowest | 4,500 ₹5,310 |
| 1.08 | Supply of M.S. Flange 200 mm dia heavy duty holes as per site requirement. Make: ISI/ Jindal/ DJB approved make | 8 | Nos. | 9,600 ₹11,328 Lowest | 9,840 ₹11,611.2 |
| 1.09 | Fabrication and supply of suitable reducer as per site requirement for 150 mm to 200 mm | 1 | Nos | 3,850 ₹4,543 Lowest | 3,950 ₹4,661 |
| 1.10 | Supply of 200 mm bend of 6mm thickness | 4 | nos | 11,600 ₹13,688 Lowest | 11,800 ₹13,924 |
Tender Value
Refer Docs
EMD Value
₹24,800
Closing Date
18 Aug 2026, 11:15 amClosed
Executive Engineer (EnM) M-8
Office of the Executive Engineer (EnM) M-8 Nangloi Phase-III, Near Maharaja Surajmal Stadium Metro Station New Delhi-110041.
Augmentation of water supply from Nizampur BPS by replacement of old and worn out faulty pumpset of set no 1 and 2 at Nizampur BPS.
2026_DJB_296736_1
NIT No.09 /EE(EnM)M-8/2026-27 Item 05
Open Tender
Civil Works
Works
45 days
Nangloi
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Account No SB 50448339804
₹24,800
Yes
24 Aug 2026
10 Aug 2026
18 Aug 2026
10 Aug 2026
18 Aug 2026
10 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Dismantling of electric connection from panel and motor, pump and motor from coupling, motor and pump removed from base frame. Removing suction and delivery lines, sluice valves, NRV, old damaged MS base frame from foundation etc by electric cutter, gas cutter, tools and tackles, manual labour and shifting the same to JE store. | 2 | Jobs | 80 | ₹160 |
| 1.02 | Breaking of existing RCC foundation by manual means including manual tools or electric demolition hammer as per site requirement including digging upto 50 cm for laying the new foundation and disposing off malba as per instructions from engineer – in – charge within 1 km of radius from site. | 2 | Job. | 80 | ₹160 |
| 1.03 | Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump including form work and finishing etc as required as per site requirement. | 2 | Job. | - | - |
| 1.04 | Providing and fixing of MS base frame as per site sample and directions of engineer in charge for 60 HP motor and pump set. | 2 | Job. | - | - |
| 1.05 | S/o Horizontal split casing Centrifugal pump with impeller (CI), neckring (Bronze) and casing (CI) shaft and sleeve (SS-410) in fitted condition with suitable bearings with head 42 m and discharge 346 m3/ hr, RPM- 1480, suction/ delivery size: 200 mm / 150 mm, rated input: 60 HP equivalent to SCP 150/390 HA of M&P make. Make: Wilo Matter and Platt, KBL, DJB approved make | 2 | Nos | - | - |
| 1.06 | Supply of M.S. Pipe 200 mm, 6 mm thick make Jindal / tata / DJB approved make | 7 | mtr. | - | - |
| 1.07 | Supply of M.s. pipe 150 mm, 6 mm thick. Make: Jindal / Tata / DJB approved make | 2 | mtr. | - | - |
| 1.08 | Supply of M.S. Flange 200 mm dia heavy duty holes as per site requirement. Make: ISI/ Jindal/ DJB approved make | 8 | Nos. | - | - |
| 1.09 | Fabrication and supply of suitable reducer as per site requirement for 150 mm to 200 mm | 1 | Nos | - | - |
| 1.1 | Supply of 200 mm bend of 6mm thickness | 4 | nos | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.04 MB
BOQ_395115.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .