Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.0 LAccepted-AOC | ₹32.0 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹33.6 L+₹1.6 L (5.04%)Rejected-Finance 32 FATEH ENCLAVE OFFICERS ENCLAVE PHASE II PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | ₹33.6 L+₹1.6 L (5.04%) | L2 | Rejected-Finance Other than lowest |
| 3 | Rejected-Technical | - | - | Rejected-Technical NOT ENLISTED IN REQUISITE CATEGORY |
Tender Value
₹49.3 L
EMD Value
₹98,560
Closing Date
25 Mar 2024, 6:00 pmClosed
GE AF AMBALA
GE AF AMBALA
SPECIAL REPAIR TO BLDG NO. T-77, T-78, T-109, T-110 AND SPECIAL REPAIR/RENEWAL/REPLACEMENT OF CONVENTIONAL PERIMETER LIGHTS WITH SENSOR BASED LED LIGHTS AND MISC E/M WORKS AT AF STN PATIALA UNDER GE (AF) AMBALA
2024_MES_643808_1
GE AF/AMB-T-77/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE AF AMBALA
ALL AS PER NIT AND TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE AF AMBALA
₹98,560
Yes
10 Jun 2024
23 Feb 2024
27 Mar 2024
23 Feb 2024
25 Mar 2024
11 Mar 2024
Amount
Supply and fixing LED street light fitting 60 Watt 230 V AC worm white outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including dismantling and taking down fluoroscent tube light single/double of any wattage or size street light fittings complete all as specified and directed.
Supply and fixing three phase timer switch infrared sensor with pre-drawn switching off timer, MCB power contactor, panel of maximum load capacity of 5-8 KWs, 230 volts, 50 Hz, degree of protection conforms to IP-66 complete all as specified and as directed.
S&F Street light bracket made out of 40mm dia GI medium grade pipe 1.2 mtr long bend to shape 120 degree and fixing with 2 No's of MS clamps of 25x4 mm thick flat iron including Nuts, Washers and bolts complete fittings arrangements suitable for any type of poles complete all as specified and directed.
S&F PVC insulated copper conductor, three core cable size of 1.5 sq mm drawn in PVC conduit and fixed on pole to connect flood/ security light on the top of the pole complete all as specified and directed.
Dismantling pre stressed cement concrete poles 9 mtr long complete all as specified and directed.
Supply, erecting and fixing, in true vertical position/as strut, 6 Mtrs. GI Octagonal Pole as per Dimension: Top Dia. - 70 mm, Bottom Dia. - 135 mm, Thick- 3 mm. Base Plate-200 X 200 X 12 mm. PCD-200mm. and including RCC Foundation and Foundation Bolts of size M20 x 750 x 4Nos. complete all as specified and directed.
S&F Street light bracket made out of Hot Dip GI: 1000mm Long 40mm dia light class Single arm bracket with 300mm long cap. and complete fittings arrangements suitable for Octagonal poles all as specified and directed..
M&L for cable junction box of size 205x255x112 with connectors and hinged cover weather proof with locking arrangement suitable for three pahse 415 V, 50 Hz electric supply mounted on insulators and fixed to pole by means of SS clamps, nuts and bolts and washers including cables connection, one MCB SP 10 Amps for ON/OFF complete all as specified and directed.
Taking up/ down LT UG Cables from trenches, poles, walls, under roads etc., complete all as specified and directed
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core, complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core, complete all as specified and directed.
Excavation in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth for foundation etc for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out including forming of bottom for laying cable complete all as specified and directed by Engineer-in-Charge
Returning filling in soft & loose/hard & dense soil including spreading levelling, watering and well ramming in layers not exceeding 25 cms complete all as specified and directed by Engineer-in-Charge..
Removal of excavated material not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 mtrs above the starting point all as specified and directed by Engineer-in-Charge..
M&L filling approved river sand in trenches for sand cushioning of laying of cables to the full width of excavated trench 08 cm thick before laying the cable and 15 cm above the cable, gently punned down, stretching and testing of cable on transformer yard etc complete all as specified and directed. Note :- Thickness of sand cushioning after punning down i.e 18cm shall be measured for payment.
Supply and laying well burnt fire Bricks of size 230x115x75 mm, locally available best quality (sub class "B" bricks) laid in trenches with 230mm side perpendicular to U/G cable for cable protection complete all as specified and directed.
M&L for boring/auguring suitable hole & insertion of GI pipe upto 80 mm including supply and inserting pipe not less than 600 mm below existing PCC/road/hard standing complete all as specified and directed. Note:- Cost of equipment, exacavation, earth work, tools & plants & material required for boring shall be deemed to be included in the rates quoted.
M&L for chemical earthing with copper earth plate electrode 900 x 600 x 05 mm thick buried directly in ground earth pit not less than 3.75 m below normal GL with the top edge of the plate not less then 2.50 m below the normal GL connected to copper strip 32x6mm protected by 40mm GI pipe (light grade) and watering pipe 20mm bore GI pipe (light grade) and chamber with PCC (1:4:8) type D2 (using 40mm graded mechanically crushed stone aggregate), coping with (1:3:6) type CI (using 20mm graded mechanically crushed stone aggregate) and with RCC pit cover (50 mm thick) in 1:2:4 type B1 using 20mm graded mechanically crushed stone aggregate, reinforced with 8mm for MS bar at 80mm c/c both way in lieu of CI pit cover with angle iron frame including excavation and earth work and removal of surplus soil of earth complete all as shown in electrical plate No 3 of SSR Part I and including charcoal dust, common salt and magnesium sulphate in layer 150mm thick in all sides of the plate and earth lead connected to earthing test point testing of earthing including taking down/up existing unserviceable earthing with accessories and dispose off from site complete all as specified and directed. Notes: (i) Cost of Earth strip/wire and GI pipe for protection of earth wire/strip upto 7.50 metre shall be deemed to be included in the quoted rate. (ii) On testing if the desired earth resistance is not obtained, entire earthing shall be re-done by contractor/ till desired earth resistance is not obtained without accruing any extra cost to department. (iii) The chamber shall be constructed atleast 1.5 mtr away from the earth electrode.
M&L for Copper strip 32 x 6 mm with saddles and fixing screws etc. for ground/wall/roof conductors including taking down conductors above ground all as specified and as directed.
S&F test point terminal block made out of gun metal or phosphorous bronze size 150x150x75 mm depth , drilled , cutting upper & lower portion for incoming & outgoing including double insulators two coat of synthetic enamel paint complete all as specified and directed
Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
S&F PVC insulated copper conductor, three core cable size of 2.5 sq mm drawn in PVC conduit in earth and fixed on pole to connect flood/ security light on the top of the pole complete all as specified and directed.
S&F GI pipe light grade 50mm dia with all fittings & fixed complete on pole/walls/in road etc for cable protection complete all as specified and directed.
M&L for plain cement concrete, (1:2:4) type B1, (using 20 mm graded mechanically crushed stone aggregates) as in coping of pole or foundation including necessary form work complete all as specified and directed.
M&L for plain cement concrete, (1:3:6) type C2, (using 40 mm graded mechanically crushed stone aggregate) as in coping of pole or foundation including necessary form work complete all as specified and directed.
Supply and fixing LED Bldg security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply and fixing Universal mounting passive infrared sensor with good sensitivity detector, integrated circuit, power source 220V-240V AC, 50 Hz/ 60Hz, Ambient light <3 lx to 2000 lx (adjustable) time delay Min. 10 s ± 3 s Rated load 1200 W detection distance Upto 8 m radius (Adjustable) etc, complete all as specified and directed by Engr-in-charge.
M&L for sub main wiring with 2 runs of single core PVC insulated FRLS unsheathed multi-stranded copper conductor cables of size 2.5 sqmm drawn through and including non - metallic rigid PVC conduits/ casing and capping of suitable size with all necessary fittings and provision of one run of 2.5 sqmm PVC insulated unsheathed multistranded copper conductor single core for earth continuity and connected to common earth dolly, complete all as specified and directed. Note: Two runs of 2.5 sqmm cable, one run of 2.5 sqmm earth conductor cable and one run of PVC conduit / casing and caping shall be measured and paid together as one unit length.
M & L for modular Metal flush box 4 module, complete all as specified and directed.
M & L for Modular White cover plate with frame, 4 module, complete all as specified and directed.
M & L for modular switch 2 way 10A 1 module, complete all as specified and directed.
S&F MCB DB TPN 4 way with, 415 V, double door type and including flush in wall to fix the MCB DB, complete all as specified and as directed.
Supply and fixing TPN 40 AMP 415V 10KA 'C' curve miniature circuit breaker (MCB) in the DB complete with connection testing and commissioning complete all as specified and directed.
S&F MCB DB SPN 8 Way with 200 Amps rated bus bars double door type and including provision of 2nd class hard wood board with sunmica top of suitable size fixed to wall and fixing of the MCB DB on board complete all as specified and directed.
Supply and fixing SPN 32 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed
Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed
Starter panel have non draw out type indoor installation with dust and vermin proof compartmentalized design single front construction ,weld rivet,hinges threads shall be apparent from outside, powder coated panel with tricationic Phosphating Epoxy based with10 tank spray based system ,tested for 500 hours salt spray with 60-100 microns Powder Thickness .Gasket Have (Joint less Polyurethane gasket ensuring sustained IP Protection,Temp withstand capacity –40 to +80ºC ,Resistance to mild acids & solvent) 2mm CRCA IP-54 Protection Paint RAL-7032/7035 with copper busbar of 300 amp having Electrolytic grade copper with 98% purity three phase 4 wire SCADA compatible complete all as specified and directed.
Supply, Installation, Testing & Commissioning of Ultrasonic Level Transmeter at O/H Reservoir (for measurement of water level) Range: 0-5 mtrs, Accuracy: 0.5%, Supply Voltage: 24 V DC, Output: 4-20mA Note : Display unit of Ultrasonic level transmitter shall be installed in PH
S&F for pressure switch Universal type, complete all as specified and directed.
M&L for earthing with galvanized iron earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25 m below normal GL with the top edge of the plate not less then 1.5 m below the normal GL connected to GI earth strip 32x6 mm protected by 40mm bore GI pipe (light grade) and watering pipe 20mm bore GI pipe (light grade) and chamber with PCC (1:4:8) type D2 using 40mm graded mechanically crushed stone aggregate, coping with (1:3:6) type CI using 20mm graded mechanically crushed stone aggregate and with RCC pit cover (50 mm thick) in 1:2:4 type B1 using 20mm graded mechanically crushed stone aggregate, reinforced with 8mm for MS bar at 80mm c/c both way in lieu of CI pit cover with angle iron frame including excavation and earth work and removal of surplus soil of earth complete all as shown in electrical plate No 3 of SSR Part I and including charcoal dust, common salt and earth lead connected to earthing test point testing of earthing including taking down/up existing unserviceable earthing with accessories and dispose off from site complete all as specified and directed. Notes: (i) Cost of Earth strip/wire and GI pipe for protection of earth wire/strip upto 7.50 metre shall be deemed to be included in the quoted rate. (ii) On testing if the desired earth resistance is not obtained, entire earthing shall be re-done by contractor/ till desired earth resistance is not obtained without accruing any extra cost to department. (iii) The chamber shall be constructed atleast 1.5 mtr away from the earth electrode.
M&L for galvanised iron strip 32×6mm as earthing lead with saddles and fixing screws etc. for ground/wall/roof conductors including taking down conductors above ground complete all as specified and directed.
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed.
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed.
M&L for earthing with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25 m below normal GL with the top edge of the plate not less then 1.5 m below the normal GL connected to GI wire 4mm dia protected by 15mm GI pipe (light grade) and watering pipe 20mm bore GI pipe (light grade) and chamber with PCC (1:4:8) type D2 using 40mm graded mechanically crushed stone aggregate, coping with (1:3:6) type CI using 20mm graded mechanically crushed stone aggregate and with RCC pit cover (50 mm thick) in 1:2:4 type B1 using 20mm graded mechanically crushed stone aggregate, reinforced with 8mm for MS bar at 80mm c/c both way in lieu of CI pit cover with angle iron frame including excavation and earth work and removal of surplus soil of earth complete all as shown in electrical plate No 3 of SSR Part I and including charcoal dust, common salt and earth lead connected to earthing test point testing of earthing including taking down/up existing unserviceable earthing with accessories and dispose off from site complete all as specified and directed. Notes: (i) Cost of Earth strip/wire and GI pipe for protection of earth wire/strip upto 7.50 metre shall be deemed to be included in the quoted rate. (ii) On testing if the desired earth resistance is not obtained, entire earthing shall be re-done by contractor/ till desired earth resistance is not obtained without accruing any extra cost to department. (iii) The chamber shall be constructed atleast 1.5 mtr away from the earth electrode.
M&L for galvanised iron strip 4mm dia galvanised iron or steel wire as earthing lead with saddles and fixing screws etc. for ground/wall/roof conductors including taking down conductors above ground all as specified and directed.
M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
Supply and laying in trenches/on ground steel water tubing galvanised 80 mm bore light grade ISI marked with all fittings and including taking down existing rusted pipe complete all as specified and directed.
Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing) removing serviceable tiles to store andd rubbish off the premises complete all as specified and directed.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. complete all as specified and directed.
Taking down cement or cement lime plaster, any description on stone walls etc incl raking out joints hacking for key, scrubbing down with water, etc. complete all as specified and directed.
Supply only water proofing compound. complete all as specified and directed.
M&L for 18 - 20 mm thick size 550X550 machine cut kota stone slab flooring over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and mirror polishing for thread in stair case and including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for 20 - 25 mm thick kota stone slab as in riser/skirting/dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing andincluding 10 mm thick backing coat in CM 1:4 complete all as specified and directed.
M&L for Vitrified coloured ceramic tiles 10 to 12 mm thick (square/rectangular), area of each tiles exceeding 0.18 sqm but not exceeding 0.38sqm, in floors etc. set & jointed in net cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for Vitrified coloured ceramic tiles 10 to 12 mm thick (square/rectangular), area of each tiles exceeding 0.18 sqm but not exceeding 0.38sqm, as in skirting etc. set & jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick backing coat in CM 1:4 complete all as specified and directed.
M&L for Non-skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular), area of each tiles exceeding 0.11 sqm but not exceeding 0.18sqm, in floors etc. set & jointed in net cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for coloured glazed ceramic tiles of size350x250x7mm/450 x 350 x 7mm thick on vertical surface such as skirting/dado, set and jointed in net cement slurry and pointed in colour cement to match ver 10 mm thick backing coat in CM 1:4 complete all as specified and directed.
M&L 18- 20mm thick pre-polished green marble(Udaipur green) (of any type) (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar(1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. complete all as specified and directed.
M&L for rounding to edges of stone slabs two edge full round,such as in steps,cooking platform and other similar situation complete all as specified and directed.
M&L for 75mm thick cement concrete 1:3:6 type C1, using 20mm graded mechanically crushed stone aggregate as in plinth protection, finishing cement concrete surfaces even and smooth without using extra cement, Joints of plinth protection shall be filled with bitumen mastic (1:3) complete all as specified and as directed.
M&L for rendering 15mm thick cement plaster 1:6 on brick masonry surface or surface other than fair face of brickwork surface finished even and smooth without using extra cement. complete all as specified and directed.
M&L for rendering cement plaster 15mm thick and surface of brick work in two layer i.e(10+5)10mm thick 1st layer and 2nd layer is 5mm cement mortar (1:4) on fair faces of brick work or concrete surfaces using water proofing compound @ 3% by weight of cement or as per manufacturer instructions, finished even and smooth without using extra cement complete all as specified and directed. Note:- Supply only water proofing compound shall be measured and paid separately.
M&L for rough cast plaster including 15mm thick rendering in CM 1:3 on brick wall or concrete surfaces complete all as specified in SSR Part - I clause 14.22 complete all as specified and directed. Note : Rough cast finish to be as below :- After applying the under coat of cement mortar 1:3 and while it is still in plasic state the rough cast mixture consisting of crushed stone or fine gravel agg (which is generally of size between 6 to 12mm depending on the texture required ) mixed with course sand and cement in the ratio of 1 : 1 : 1 shall be applied and finished even. The mix of cement and sand shall be made slightly wetter than normal for rendering to ensure that larger agg are thoroughly covered.
M&L for preparing of new plastered or un-plastered surfaces and applying two coats of oil bound distemper including priming plastered and other surfaces with alkali resistant priming paint over 3mm thick wall care putty complete all as specified and directed.
M&L for complete removal of existing treatment and preparation of old plastered or un-plastered surfaces and applying two coats of oil bound distemper including 3mm thick JK birla wall care putty , complete all as specified and directed.
M&L preparation for new plastered / concrete wall surfaces, etc. and for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over (camouflage pattern) and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces incl providing over a coat of wall care putty over plastered surface to prepare the surface even and smooth, complete all as specified and as directed
M&L complete removal of existing treatment of wall and preparation of old plastered or Un plastered surfaces of wall and for applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over (camouflage pattern) and including providing over a coat of wall care putty over plastered surface to prepare the surface even and smooth, complete all as specified and as directed
Material and labour anodised aluminium door and chowkhats made out of hollow extruded aluminium section as mentioned below. Each door shall be provided with 02 Nos disc or D type aluminium handles, 02 Nos aluminium tower bolts 200mm long, one brass mortice lock of six levers with key in duplicate and shall be regulated by provided double action hydraulic floor door spring/hydraulic door closer (Make sandhu/RITZ). Shutter to be partly glazed with and including 5mm thick tinted glass and partly panelled with and including 12mm thick prelaminated particle board with decorative laminations on both sides, rubber beading/gasket, anodised aluminium beading, screws complete in all respect all as directed by the Engineer-in-charge. Chowkhat/frame : 101.6x44.45x1.5mm thick Shutter top and bottom rail : 114.3x44.45x1.5mm thick Shutter middle rail : 83.5x44.45x1.5mm thick Shutter vertical/style : 83.5x44.45x1.5mm thick MAKE : (i) Anodised aluminium section : JINDAL, HINDALCO, INDALCO (ii) PARTICLE BOARD : NOVAPAN, KITPLY, BHUTAN BOARD (iii) Glass : saint gobain, modi guard, TATA.
Supply and fixing anodised aluminium window / ventilator including aluminium grill made out of hollow extruded section as mentioned below and glazed with tinted glass 5mm thick fixed with glazing clips rubber beading/gasket anodised aluminium beading screw and lock type handles of size 75mm, 2 Nos aluminium tower bolts 150mm long etc complete all as specified and directed with the following sizes:- Chowkat/Frame Size : 101.6x44.45x1.5mm thick Mullion: Not less than 0.55Kg/RM Shutter : Not less than 0.55 Kg/RM
Taking down chowkats or frame (doors/windows) of any description n exc 1.5 Sqm each (without taking off shutters from the frames) complete all as specified and directed.
Taking down chowkats or frame (doors /windows) of any description exc 1.5 Sqm each and n.exc 4 Sqm (without taking off shutters from the frames) complete all as specified and directed.
S&F, MS angle iron framed work as in doors or gates of angle or other section conforming to Fe 290(Gde E-165) with gusset plates, rails, braces, etc complete including hanging also fastening and fixing and making the surface good, complete all as specified and directed.
S&F, 35mm thick, second class HW in glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc.(without sash bars) edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass, etc. size of members of shutters as specified in SSR Part-I, section 8, clause 8.24 (a) supplied and fitted to chowkats complete all as specified and directed by Eng-in-Charge.
S&F 35 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides. complete all as specified and directed.
M&L for preparation of new wooden surface of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed.
M&L for Preparation of old painted wood and wood base surfaces of any description, not otherwise described over 10 cm width or girth and painting with a coat of sythetic enamel paint complete all as specified and directed.
S&F, 150mm size, aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S&F, aluminium, anodised barrel tower bolt of extruded section and fixed 200 mm of size complete all as specified and directed.
S&F, 150mm long floor door stopper of aluminium alloy body and tongue with hard drawn steel springcomplete all as specified and directed.
S&F butt hinges, medium weight, cold rolled, mild steel of size 100 mm complete all as specified and directed.
S&F, SS 25mm dia , powder coated, fancy type, aluminium decorative tubular curtain rod with decorative ball type side brackets, stops ,rollers etc, complete all as specified and directed.
Supply and fixing 300mm long, Aluminium alloy, anodised sliding door bolt with hasp, staple ( bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts of extruded sections or cast aluminium alloy, complete all as specified and directed.
Supply and fixing Solid PVC Door frame of size 50 mm x 47mm made out of 5mm plain PVC sheet reinforced with 19mm x 19mm M.S. Square tube profiles are mitred cut at corners and joined by inserting 2 Nos 150 mm long brackets of 15mm x 15 mm MS square tube shall 19 mm x 19 mm in square tubes and suitably scruwed suppling & fixing in opening, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing factory made solid panel PVC door shutter, 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded /sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement and fixed in the frame at site complete as per specification and drawing complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Butt hinges 125 mm size, medium weight, cold rolled mild steel complete all as specified and directed..
Supply and fixing 150mm long Aluminium, anodised, barrel tower bolt of extruded section complete all as specified and directed.
Supply and fixing aluminium handles, cast type, anodised 150 mm size complete all as specified and directed.
S&F, in repairs, 18/19mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice laminations and other side balancing white lamination, fixed with screws to timber frame work in cup boards, rebated or flat edged complete all as specified and directed.
M&L for 6mm thick external teak wood lipping fixed to18/19mm thick block or Veneered particle boards with nails complete all as specified and directed.
S&F continuous (piano) hinges, mild steel bright finish or electrogalvanised, width of flap 40 mm complete all as specified and directed.
S&F hasp & staples 125mm in size, safety type aluminium anodised fixed with screws complete all as specified and directed.
S&F Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed complete all as specified and directed.
S&F, in repair, 1mm thick, stainless steel plate rack of size 1200mm x 900mm x 180mm complete all as specified and directed.
S&F in repair sinks with drainage board made of stainless steel 1mm thick for kitchen with plugs, washers and waste coupling; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160m including 32 mm PVC waste pipe, complete all as specified and directed.
S & F white glazed earthen ware vitreous china wash hand basin of size 550x400mm with and including CI brackets, 32mm bore brass CP waste coupling Inlet/ outlet, 32mm PVC waste pipe and PVC connection/ flexible pipe 600mm size for 15 mm bore pipe with brass nut and washers etc complete all as specified and directed.
S&F, one piece vitreous china wash down water closet pan (Pedestal pattern), white with 'p' or 's' trap (including flushing cistern and flush pipe), including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe etc. including its plastic seat cover white closed pattern with flat bottom and mild steel chromium plated or aluminium hinging device and SS brass chromium plated jet spay fixed with seat cover, complete all as specified and directed.
S&F, in repairs, 15mm brass chromium plated fancy type bib cock with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F, in repairs, 15mm stop valves /Angle valves/conceal stop cock, fancy type brass chromium plated for iron pipe or for unions and fixed to 15mm bore pipe, complete all as specified and directed.
S & F 15mm pillar taps, brass chromium plated fancy type with capstan heads, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts screwed for iron pipe or for union and fixed to 15mm bore pipe, complete all as specified and directed.
S&F in repair PVC connections 15 mm size with PTMT nuts of length 450 mm IN REPAIR, complete all as specified.
S&F Towel ring 200 mm dia chromium plated fancy type conforming to the sample kept in the office of Engineer-in-Charge.
S&F brass chromium plated bathroom wall (wall mounted model) mixture with hand shower incl 1 meter long flexible hose etc. complete all as specified and directed.
S&F Mixer pillar tap, cast copper alloy with capstan head, chromium plated, fancy type, screwed down, high pressure, for hot and cold water, 15 mm bore complete all as specified and directed.
S&F brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges for wash hand basin area with brackets complete all as specified and directed.
Supply and fixing in repairs 8mm dia Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect complete all as specified and directed.
S&F Toilet paper holder of brass chromium plated conforming to the samples kept in the office of Engineer-in-Charge.
Supply and fixing in repairs corner Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long , complete all as specified and directed.
S&F SS grating doom 100/125mm (with or without hole) including jointing to waste pipe fixed in cement concrete type B1 (1:2:4). complete all as specified and directed.
S&F gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe, 20mm bore complete all as specified and directed.
S&F brass chromium plated soap dish complete all as specified and directed complete all as specified and directed.
Taking up or down steel tubing and connections for 15mm bore of pipe complete all as specified and directed.
Taking up or down steel tubing and connections for 20mm bore of pipe complete all as specified and directed.
S&F steel water tubes, medium grade, galvanized, with all fittings and fixed to walls and ceilings or laid in floors for 15mm bore of pipe complete all as specified and directed.
S&F steel water tubes, medium grade, galvanized, with all fittings and fixed to walls and ceilings or laid in floors for 20mm bore of pipe complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks of capacity 1000ltrs (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR-Part-I including disconnecting and removal of old U/S PVC tank.
S&F in repairs 20mm dia ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 15mm-142 gms/ 20mm-210 gms/25mm-455gms/ 40mm- 690 gms) all as specified and directed
Dismantling of PVC pipes jointed in neat cement mortar and taking out of trenches if required. complete all as specified and directed.
Supply and fixing in repairs PVC bend any radius, conforming to IS:14735, suitable for uPVC soil waste discharge pipes 110 mm size, with oval and access door, complete all as specified and directed. MAKE: SUPREME, FINOLEX, PRINCE, DIPLAST.
Supply and fixing in repairs PVC bend any radius, conforming to IS:14735, suitable for uPVC soil waste discharge pipes 75 mm size, complete all as specified and directed. MAKE: SUPREME, FINOLEX, PRINCE, DIPLAST.
Supply and fixing in repairs PVC cowl any radius, conforming to IS:14735 suitable for 110 mm bore,complete all as specified and directed. MAKE: SUPREME, FINOLEX, PRINCE, DIPLAST.
Supply and fixing in repairs UPVC floor/ Nahani trap with PVC grating suitable for 75 mm external dia, type-B pipes, ISI marked including jointing to waste pipe fixed in cement concrete type B1 (1:2:4), complete all as specified and directed. MAKE: SUPREME, FINOLEX, PRINCE, DIPLAST.
Supply and fixing in repairs PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement for 110 mm external dia, type-B pipes, ISI marked complete all as specified and directed. MAKE: SUPREME, FINOLEX, PRINCE, DIPLAST.
S&F PVC(SWR) pipes 110mm bore single socketed, in any length with rubber ring joints, fixed to walls complete including faixing clamps, complete all as specified and directed.
S&F 75mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints laid in trenches or in floors/walls complete all as specified and directed.
S&F 110mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints laid in trenches or in floors/walls, complete all as specified and directed.
M&L for cement concrete (1:4:8) type D-2 using 40mm graded mechanically crushed stone aggregates as in Foundations filling and mass concrete all as specified and directed.
Demolition cement concrete (unreinforced) in ground floor and pavings n exc 15cm thickness (below or above ground level) complete all as specified and directed.
M&L for brickwork with sub class 'B' Bricks (old size), straight or curved on plan exc 6m mean radius, built in CM 1:4 complete all as specified and directed.
Demolition of brick work or stone boulder masonary built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed by Engineer - in - Charge.
Dismantling asbestos cement /Galvalume auminum(corrugated, semi corrugated) sheets including ridges as in roof covering.complete all as specified and directed.
M&L pre painted galvalume aluminium zinc coating GI based corrugated Steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mps as in roof covering/cladding to wall fixed with self tapping screwes complete all as specified.
M&L for MS work as in tubular/angle roof trusses (framed), trusses, purlins crane gantries, rails and fastening and heavy brackets framing (beam, tee, angle, channel or flat sections) including distance pieces cleats etc conforming to Fe 410 W (Gde E 250) quality B complete all as specified and directed.
Material and labour for preparing surfaces of new or previously untreated surfaces of steel or metal works and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer over 10cm in width or girth complete all as specified and directed.
Material and labour for preparing old surfaces of steel or metal works and applying two coats of synthetic enamel paint over 10cm in width or girth complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre,pulp, insulation, etc or insulation boards/slabs/blankets,any thickness including cover fillets complete all as specified and directed.
M&L for 12mm thick Perforated particle board /tiles for insulation and accoustic purpose, 60x60 cm in size, fixed with nails to timber frame work wth staples on ta a snap grid complete all as specified and directed.
S& F Size of grid 605 x 605mm Anodised aluminium snap grid for work for false ceiling complete all as specified and directed.
S&F Hanger of GI (upto 1200mm length ) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size 60mm long expension hold fastener 12.5mm dia. 40 mm long complete all as specified. made out of GI flat 40x3mm size 60 mm long complete all as specified and directed.
S&F solid PVC wall lining consisting of 5mm thick plain colour PVC Sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawings complete all as specified and directed.
S&F 5 mm thick PVC Sheet fillet of width 35 mm for wall paneling inclusive of fixing on to wall to make PVC frame as per specification and drawing complete all as specified and directed.
M & L for plain cement concrete M-10 Nominal Mix (1:2:4) Type B-0 (using 12.50 mm graded mechanically crushed stone aggregate), as in lintels upto 1.5 m clear span, cills, steps,seismic and other similar bands, plinth course, string courses, lacinng courses, parapets and railings, copings, kneelers, apex stones, bed plates, hold fast, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
Material and labour for 25mm thick PCC 1:2:4 type B1 (20mm graded mechanically crushed stone aggregates) in sub base complete all as specified and directed.
S&F, Chromium over head shower rose 100mm dia round shape single flow (ABS Body chrome plated with Gray face plate) with rubit cleaning system, with or without swivel joints, any size, including fixing to steel pipe or union, complete all as specified and directed
Supply and fixing in repairs 32 mm bore dia wastepipe for WHBs/urinals/sinks, including all joints and necessary fitting ,complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.complete all as specified and directed
M&L for Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and directed.
M&L for point wiring (concealed type) 1.5 Sqmm single core PVC insulated FRLS unsheathed 1100 volts grade copper conductor multi-stranded cables drawn through non - metallic rigid PVC conduits and conduit accessories and provision of one run of PVC insulated FRLS unsheathed 1100 volts grade copper conductor multi-stranded single core cable of size 1.5 sqmm for earth continuity conductor and connected to common earth dolly including provision of suitable size of modular metal box flush in wall with and including white colour cover plates for mounting modular type switches, sockets, fan regulators, bell pushes etc. for one light point, ceiling fan, exhaust fan controlled by one switch 1 way complete all as specified and as directed.
All as per BOQ srl item No.148.00 here-in-above but for One call bell point controlled by one switch complete all as specified and as directed.
All as per BOQ srl item No.148.00 here-in-above but for One 05 Amps socket outlet on independent board. complete all as specified and as directed.
All as per BOQ srl item No.148.00 here-in-above but for One 05 Amps socket outlet on the same board with other switches. complete all as specified and as directed.
All as per BOQ srl item No. 148.00 here-in-above but wiring with 2.5 Sqmm single core PVC insulated FRLS unsheathed 1100 volt grade copper conductor and with one run of copper conductor PVC insulated multi-stranded cable 2.5 Sqmm for earth continuity conductor and connecting to common earth dolly, complete for one 15 Amps power socket point on independent board complete all as specified and as directed.
Taking down carefully existing unserviceable sub main wiring of aluminium conductor cable of any size and capcity complete all as specified and directed.
M&L for sub main wiring with 2 runs of single core PVC insulated FRLS unsheathed multi-stranded copper conductor cables of size 06 sqmm drawn through and including non - metallic rigid PVC conduits of suitable size with all necessary fittings and provision of one run of 06 sqmm PVC insulated unsheathed multistranded copper conductor single core for earth continuity and connected to common earth dolly, complete all as specified and directed. Note: Two runs of 06sqmm cable, one run of 06 sqmm earth conductor cable and one run of PVC casing and caping shall be measured and paid together as one unit length.
M&L for sub main wiring with 2 runs of single core PVC insulated FRLS unsheathed multi-stranded copper conductor cables of size 04 sqmm drawn through and including non - metallic rigid PVC conduits of suitable size with all necessary fittings and provision of one run of 04 sqmm PVC insulated unsheathed multistranded copper conductor single core for earth continuity and connected to common earth dolly, complete all as specified and directed. Note: Two runs of 04 sqmm cable, one run of 04 sqmm earth conductor cable and one run of PVC casing and caping shall be measured and paid together as one unit length.
M & L for modular switch 1 way 6A, 230 Volts, 1 module. complete all as specified and as directed.
M & L for Modular socket, 6A-2/3 pin, 2 module . complete all as specified and as directed.
M & L for modular switch 1 Way 16A, 230 volts, 1 module.complete all as specified and as directed.
M & L for modular socket 6/16A, 2/3 pin. 2 module.complete all as specified and as directed.
M & L for modular Bell push 6A 1 module.complete all as specified and as directed.
M & L for bell Buzzer, Ding Dong AC, 230 volts, single pole complete all as specified and directed.
S&F ceiling rose, PVC body, 3 terminal suitable for 230 volts AC supply, complete all as specified and directed.
M & L for modular fan regulator electronic step type, 02 module. 230 Volts, suitable for 1200 mm sweep ceiling fan, complete all as specified and directed.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
Supply and fixing round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply and fixing LED Street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
Taking down fan, regulator, sealing cable end, dismantling blades and removing fan and blades to store and M&L for Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. and Hanging only ceiling fan (M.D.supply) and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed
Taking down fan,cable end, dismantling blades and removing fan and blades to store and M&L for Painting of exhaust fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. and Fixing only exhaust fan (M.D.supply) and connecting up including provision of cable from ceiling rose/connector to fan complete all as specified and directed
M&L for rewinding of following fans with same gauge of super enameled copper wire complete,varnishing ,baking , connecting properly with sleeves assembling the same including replacement of unserviceable shackle and clamps with nots /bolts/washer /split pin and blade screws etc testing,complete all as specified and directed. NOTE: (a) The rates shall be deemed to include Spare parts like bearing, capacitor, bushes if required and reassembling after repair /replacement of worn out parts
Ceiling fan 1200 /1400 mm sweep
Exhaust fan 300 mm sweep
Dismantling electric/water connection and taking down of storage type water heater,servicing,cleaning of inner tank etc.at site.and replacement of burnout parts etc. and refixing in situ complete all as specified and as directed. Note- (a) Detection and rectification of leakage of inner tank of geyser by brazing/ welding/ soldring and Painting of geyser shall be deemed to be included in quoted rate. (b) The rates shall be deemed to include Spare parts like Heating element 1.5 KW, Thermostat, Rubber Gasket for inner tank, Air release valve, Fusible lead nut, Indicator lamps, PVC connections etc, and reassembling after replacement of worn out parts
S&F in repairs sheet metal enclosures for MCB distribution board 230V, SPN, 4 way, double door type flushed inside wall with suitable rated bus bar and making good the disturbed surfaces complete all as specified and as directed
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm 2 core complete all as specified and as directed.
SWAMI ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .