Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹29.4 L
EMD Value
₹58,900
Closing Date
31 Jan 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Amritsar
GARRISON ENGINEER AMRITSAR CANTT PIN 143001
SPL REPAIR TO BLDG NO P 23 AND P 25 MD ACCN VIKRAM BATRA ENCLAVE AT OLD AMRITSAR CANTT
2026_MES_747031_1
GE/ASR-82/2025-26
Open Tender
Civil Works
Works
180 days
GE Amritsar
CLASS D Category a i
8 documents required · 8 mandatory
₹500
GE Amritsar
₹58,900
2 Jan 2026
2 Jan 2026
7 Feb 2026
2 Jan 2026
31 Jan 2026
17 Jan 2026
3 Jan 2026 - 10 Jan 2026
Dismantling Brick tiles or terracing tiles, single layer on roofs ; Complete all as specified and as directed.
Demolition mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) ; Complete all as specified and as directed.
Material and Labour for PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in padding concrete fair finish of required thickness on roofs, roof kerbs or mud stops, rounded or chamfered on edges and like including weathering slight rounded and throating ; Complete all as specified and as directed.
Material and Labour for applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 Kg/Sqm including priming coat, cleaning surfaces etc ; Complete all as specified and as directed.
Supply and Fixing (minimum) 3mm thick APP film based poly meric membrance minimum weighing 3Kg per Sqm reinforced with polyester non wove fabric (weight not less than 150 gms/sqm) land on primed surface by forced application over entire roof area with over lapping 100mm to either sides and sealed in after cleaning down the roof by brooms ; as per manufacturer instructions Complete all as specified and as directed.
Material and Labour for 40mm thick brick tiles, laid on and including 15 mm thick cement mortar 1:6 and joints grouted and pointed flush in cement mortar 1:3 mixed with 5% crude oil by weight of cement ; Complete all as specified and as directed.
All as per Srl Item No. 06 here-in-before but except brick tiles. Note:-Old serviceable tiles shall be reused.
Disconnecting existing tanks 500ltr capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc
Demolition of brickwork, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed.
Material & Labourfor brick work with sub class "B" bricks (old size) straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 complete all as specified and directed.
Taking down cement plaster of any description on brick walls, etc including backing & raking out joints, hacking for key scrubbing down with water etc complete all as specified and directed.
Material & Labourfor rendering 15 mm thick on brick work or concrete surfaces on walls in cement mortar 1:6 finishing even and smooth without using extra cement complete all as specified and directed.
Material & Labourfor rendering 15 mm thick on brick work or concrete surfaces on walls in cement mortar 1:4 finishing even and fair surface without using extra cement complete all as specified and directed
Material & Labourfor rendering 10 mm thick on brick work or concrete surfaces on ceiling in cement mortar 1:3 finishing even and smooth without using extra cement complete all as specified and directed.
Material & Labour for PCC 1:1.5:3 type B0 using 12.5 mm graded stone aggregate for repair of Chajja, Fascia, etc minimum thickness 25mm incliding chicken wiremesh as required upto 8 m height including necessary formwork, scaffolding and applying two coats of cement base paint over 5mm plaster cement plaster 1:3 complete all as specified and directed.
Material & Labourfor applying two coats of whitewash on ceiling including preperation of newly plastered/old decorated surfaces complete all as specified and directed.
Material and labour preparation of newly plastered surface of wall and Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work complete all as specified and directed.
Material & Labourfor preparation of New plastered surfaces and Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed.
Material & Labourfor preperation of Old decorated surfaces of walls by scraping and washing down with, removing all acales/dirts and greasy spots and applying one coat of oil bound distemper incl including preparation with wal care putty to prepare the surface even and smooth complete all as spcified and directed .
Hacking out old broken glass from wooden/ steel window cleaning the surface and removing from the site, thenafter Supply & Fixing clear glass, 3mm thick ordinary quality, in any shape, not exceeding 0.50 sqm in each pane including and glazing with oil putty/wooden beading as per site requirements complete all as specified and directed.
Supply & Fixing in repair Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples in steel window/wooden door shutter complete all as specified and directed
Supply & Fixing in repair Helical door spring 300mm, ordinary rat tail rod pattern springs, including roller and roller plate fixed to iron chowkats with weilding complete all as specified and directed.
Supply & Fixing factory made 30 mm thick flush shutters solid core construction with block board core and plywood face panels complete all as specified and directed.
Supply & Fixing factory made IInd class hard wood Glazed and skeleton shutters 35mm thick divided into square, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part I, Section 8 clause 8.24 (a) ; supplied and fitted to chowkats complete all as specified and directed
Material & Labour for two coats of synthetic enamel painting on wooden surfaces of any description over 10 cm in width or girth not otherwise described including a coat of pink primer including prepration of new surfaces complete all as specified and directed.
Material & Labour for two coats of synthetic enamel painting on steel surfaces of any description over 10 cm in width or girth not otherwise described including a coat of red oxide primer including prepration of new surfaces complete all as specified and directed.
Material & Labour for apply One coat of synthetic enamel pain on steel surfaces of any description over 10 cm in width or girth not otherwise described including prepration of old surfaces complete all as specified and directed
Material & Labour for One coat of synthetic enamel painting on wooden surfaces of any description over 10 cm in width or girth not otherwise described including prepration of Old surfaces complete all as specified and directed.
Supply & Fixing 300mm long Aluminium alloy, Anodised, sliding door bolt with hasp, staple ( bolt type) and fixing clips of sheet , cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed.
Supply & Fixing Aluminium, anodised, barrel tower bolts 150mm of extruded section and fixed complete all as specified and directed.
Supply & Fixing 150mm long Aluminium handles, cast type anodised complete all as specified and directed.
Supply & Fixing stainless steel butt Hinges, 100mm size, medium weight, cold rolled mild steel complete all as specified and directed.
Material and Labour in repair Box type steel window made of ERW tube P- section of size 60 mm x 25 mm double rebated outer frame, comprises glazed skelton & gauzed shutter of ERW tube P-Section size 50mm x 20mm with one/two Nos openable leaf for each shutter consisting of two Nos Sashbar of T-section 20 x 3 mm welded to frame with one No verticle mullion of ERW box type T Section of size 60mm x 25mm and FI 2mm thick welded/screwed to frame for fixing of glass including fittings and fixture like as Handle, Tower Bolt, Stopper, Cleat, Pintal hinges, holdfast etc as given below all as shown on drg No CEJZ/TD-1020/08 Sh 1/3 to 3/3 dt 01 May 2008 complete all as specified and directed.(a) Hold fast 150mm long of 12mm x 3mm MS flat - 4 Nos per Window.(b) Handle of Z section 20mm x 25mm, 100mm long- 01 No per leaf.(c) MS tower bolt 150mm long - 02 Nos/leaf.(d) Z Section stopper 20mm x 25mm, 100mm long - 01 No per leaf.(e) Cleat 55mm long of hollow square 15mmx12mm - 02 Nos per leaf.(f) MS pintol hinges size 75mmx12mm - 2 Nos per leaf Note :- Sheet glass, wire mesh as required and painting shall be measured and paid sperately.
Material and Labour in repair for Box type steel ventilator made of ERW tube P-section of size 60mmx25mm outer frame ( single rebated), comprises glazed shutter, frame of ERW tube and FI 2mm thick welded/screwed to frame for fixing of sheet glass including fixture and fittings like as Stopper, Cleat, Pintal hinges, holdfast etc all as shown on drg No CEJZ/TD1019/08 sheet 1/3 to 3/3 dt 01 May 2008 complete all as specified. NOTE:-Sheet glass, wire gauge as required and painting shall be measured and paid Separately.
Supply & Fixing pressed steel frames 1.25mm thick for door size of frame 125 x 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate and tarring to inner surface (surface in contact with concrete/brick surface) of chowkats and hinges incl. filling PCC type B-O complete all as specified and directed.
Material & Labourfor PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) in bed blocks for hold fast & similar work etc incl. necessary form work in repair complete all as specified and directed
Taking down chowkhat with shuttering (without taking off shutters from frame including grill & guard bars) size of shutter not exceeding 1.5 sqm each complete all as specified and directed.
All as per Srl item No 37 above but size of opening exceeding 1.5 Sqm but not exceeding 4 Sqm.
Taking down shutters of any description size of shutter exc 1 sqm but n.exc 2 sqm.
Dismantling floor, hearth or wall tiling including cement mortar bedding ( including backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Supply & Fixing non skid ceramic light coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles over and including 15mm thick screed bed in cement mortar 1:6 & complete all as specified and directed.
Supply & Fixing glazed ceramic coloured tiles 450x450mmx6mm thick, etc. on vertical surfaces such as skirting , dados and risers to steps etc. set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match over and including 10mm thick rendering plaster in cement mortar 1:4 on brick surface complete all as specified and directed.
Material & Labourfor Vitrified ceramic light shade tiles 10mm thick (Square/ rectangular) polished, area of each tiles n.exc 0.36 sqm in floors and skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of cement mortar(1:6) 15mm thick for laying floor finishes complete all as specified and directed.
Supply & Fixing in repair of One piece ceramic floor/wall mounted EWC with features like twin flush system, noisless soft close seat cover, anty-bacterial surface white with PVC(SWR) 'P' / 'S' trap 110/110mm bore complete all as specified and directed.
Supply & Fixing PVC Jet spray suitable for EWC complete all as specified and directed.
Supply and fixing Chromium plated Health faucet in repair with 1.5 metre long chain complete all as specified and directed.
Supply & Fixing in repairs centre hole wall mixer cast copper alloy chromium plated with capston head srewed down high pressure with lettered hot or cold with long screwed shanks fly nut screwed for iron pipe 15mm dia complete all as specified.
Supply & Fixing in repair WHB mixture Pillar taps 15mm bore, cast copper alloy , with capstan heads, chromium plated , screwed down high pressure , with or without l'ettered ' 'HOT' or 'COLD' with long screwed shanks and fly-nuts , screwed for iron pipe and fixed.
Supply & Fixing in repair Vanity of size 820x450mm with vitreous China wash basin white,with suitable size including CP waste coupling 32mm bore,waste PVC pipe complete all as specified and directed.
Supply & Fixing in repairs glass shelve assembly 60cm in oval shape consisting 5.5mm to 8mm thick glass including CP guard railing with double rail complete all as specified and directed.
Supply & Fixing in repair Sheet glass corner shelf assembly consisting of 5.5mm thick sheet glass corner shelf with chromium plated bracket guard and railing complete all as specified and directed.
Supply & Fixing PVC connection 15mm size with PTMT nuts of length 600mm in repair complete all as specified and directed.
Supply and fixing in repair 15mm bore type angle cock cast copper alloy CP screwed down high pressure with crutch or butterfly handle complete complete all as specified and directed.
Supply & Fixing in repair of brass cromium brass plated fancy type bib taps 15 mm bore long nose screwed down screwed for iron pipe or for brass complete all as specified and directed
Supply & Fixing in repairs 100mm dia CP grating with or without hole type complete all specified and directed.
Supply & Fixing in repairs CP brass towel rail of 20mm dia and 600mm long complete all as specified and directed.
Supply & Fixing 15mm bore tubes (medium grade) galvanised with all fittings and fixed to walls and ceiling or laid in floors complete including taking down all as specified and directed.
Supply & Fixing 20mm bore tubes (medium grade) galvanised with all fittings and fixed to walls and ceiling or laid in floors complete including taking down all as specified and directed.
Supply & Fixing in repair CP towel rail fixed to walls with chromium plated (CP) brass screws complete all as specified and directed.
Supply & Fixing in repair vitreous China Squatting pan 'Orrisa' pattren size 580x440mm white with integral foot rest and PVC(SWR) 'P' trap 110/110mm bore complete all as specified and directed.
Supply & Fixing in repair 10 Ltr capacity PVC valveless symphonic action type flushing cistern white low level with ball valve flote handle including bracket and flush pipe of polythylene of low or high density or PVC,32mm dia complete all as specified and directed.
Supply & Fixing in repair 15mm bore Concealed type stop cock cast copper alloy CP screwed down high pressure with crutch or butterfly handle complete all as specified and directed.
Supply & Fixing in repairs 125mm CP shower rose fancy type with CP arm complete all as specified and directed.
Supply & Fixing in repair PVC (SWR) pipe 75mm dia fixed in wall/floor complete all as specified and directed.
PVC (SWR) pipes single110mm socketed, in any length with rubber ring joints, laid in trenches or in floors/wall complete all as specified and directed.
Supply & Fixing in repair 75mm PVC (SWR) bends any radius complete all as specified and directed.
Supply & Fixing in repair 110mm PVC (SWR) bends any radius complete all as specified and directed.
Supply & Fixing in repair 75mm PVC floor trap complete all as specified and directed.
PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed.
Supply & Fixing factory made Solid PVC Door Frame of Size 50mm x 47mm made out of 5mm plain colour PVC Sheet reinforced with MS Square tube in opening as per specification and frawing per site complete all as specified and directed..
Supply & Fixing factory made 28 to 30 mm thick solid PVC moulded Door shutter with 2,3 or 6 raised psnel design with 2mm thick moulded PVC Sheet on the front face and 2mm plain colour PVC Sheet on back face, fixing in frame at site as per specification and drawing as per site complete all as specified and directed..
Supply & Fixing in repair rotational moulded polythene water storage tanks of 1000 litre capacity (cylindrical vertical with closed top) triple layered hoisted and fixed in position all as specified in SSR Part-1 including Ball valves high pressure PTMT with epoxy coated Aluminium rod & High density plastic ball screwed for iron pipe and fixed to GI pipe of 20mm bore complete all as specified and directed.
Dismantling boarding , any description , fixed in any position with screws complete all as specified and directed.
Material and Labour 18/19mm thick Prelaminated HDHMR board, interior grade, with decorative choice lamination, fixed with screws as in shelves/Shutters ; Complete all as specified and directed.
Supply and Fixing cupboard shutter 1.00 mm thick fitted in frame of 35x35x6mm thick including necessary fitting such as handle, lugs, locking arrangement and including shop coat of primer and n. exc 2.00 sqm area of cupboard complete all as specified and directed.
Demolition of cement concrete in ground floors and paving not exceeding 15 cm thickness ( below or above ground level) and disposing the rubbish to a distance exceeding 50 Mtr but not exceeding 100 Mtr away to low lying areas complete all as specified and directed.
Material & Labourfor 75mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) in sub base of floor complete all as specified and directed.
Material & Labour Chequered cement concrete tiles 30cm x 30cm x 25mm thick over and including 15mm thick bedding layer in cement mortar 1:6,set and jointed in neat cement slurry and pointed in grey cement and pigment to match the colour of tiles complete all as specified and directed.
Taking down carefully existing point wiring of any type (i.e on wooden batten, surface conduit, casing capping or concealed conduit) complete for light, fan, socket or power point etc. with fittings & fixtures such as ceiling rose, holders, switches, sockets, regulator, wooden batten or conduit etc. including accessories such as wooden gutties/ rawal plug, screw etc including removing materials from site for taking credit of unserviceable items and re-fixing the serviceable items, including necessary cuttings, chases and making good disturbed surface of walls, floors etc, in cement mortar 1:3 as required complete all as specified and directed. NOTE: The old serviceable material as required to be refixed shall be kept in safe custody.
Material & Labourfor point wiring complete with 1.5 sqmm single core PVC insulated sheathed multi-stranded, copper conductor FRLS grade cable of 1100 volts grade conforming to IS:694 drawn through and including non metalic rigid PVC conduit, medium grade, ISI marked, not less than 20mm bore with conduit accessories concealed on wall and ceiling/roof etc, with provn for fixing modular metal flush boxes not less than 1.0 mm thick of suitable modules, concealed in walls with modular white plated cover as top cover fixed with screws for housing switches, socket outlets, fan regulators etc, including provn of 1.5 sqmm nominal cross sectional area, PVC insulated, FRLS, sheathed, 1100 volt grade,multistranded single core green colour copper conductor for earth continuity connected to earth dolly complete all as directed for following point :- NOTE: (i) Modular metal flush boxes concealed in wall with suitable cover plate for mounting switch, sockets, regulator etc. incl. cuttings and making to disturbed surface with cement mortar, if required, shall be deemed to included in the quoted rates. (ii) Modular fittings/fixtures such as switch, socket, regulator, ceiling rose, lamp holder, bell shall be measured and paid separately.
(a) One light point controlled by one switch
(b) One fan point / Exhaust Fan controlled by one switch
(c) One bell point controlled by one bell push
(d) One 5 Amps outlet point on same board with other switches/sockets
(e) One 3 pin 5 Amps socket outlet on independent board.
All as per ser item No.81 here in above but point wiring with 2.5 Sqmm FRLS cable and 2.5 sqmm cable earth continuity wire for one 3 pin socket outlet,15 Amps on independent board.
Supply & Fixing modular switch 1 way 6A, 240 volts, 1 module complete all as specified and directed
Supply & Fixing modular switch 1 way 16A, 240 volts, 1 module complete all as specified and directed
Supply and Fixing Modular bell switch 6 Amp 1 module size complete all as specified and as directed
Supply & Fixing modular socket, 6A, 240 volts, 2/3 pin combined 2 module, flush type all as specified and directed
Supply & Fixing modular socket, 6A/16A, 240 volts, 2/3 pin combined 2 module flush type all as specified and directed
Supply & Fixing ceiling rose surface PVC/Polycarbonate, isolated body with face Bakelite 65x50 mm three terminal complete all as specified and directed.
Supply & Fixing modular fan step regulator, 2 module, 240 Volts, 50 Hz, suitable for ceiling fan 1200 mm sweep all as directed
Supply & Fixing lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
Supply & Fixing buzzer, Ding Dong, AC, 240 Volts, single pole, fixed over & including pressed steel sunk box of size 175 x 100 mm duly covered with 3mm thick bakelite sheet complete all as directed
Supply & Fixing in repair LED lights fitting 1x 20W, 220V, AC, 5700K, decorative box type with driver, double sided connection, CRI> 80, PF>95%, THD<10%, Lumen>2100 lm including LED tube light of make: Havells or equivalent in Philips/Crompton, connecting up with 3 core flexible copper conductor cable (1.0 mm² size/core) from ceiling rose complete all as specified and directed.
Supply & Fixing in repair Dusk & dawn roadway luminaries 30 Watt, 230 V AC, 5700K outdoor type with epoxy black powder coated sheet of make: Havells or equivalent make of Philips/Crompton, high pressure die-cast aluminum hosing and heat resistant complete with impact and corrosion resistant including thermal management in multiple optics, PF>95%, THD<10%, Lumen>4500 lm with IP 65/66 protection complete incl connecting wire with flexible PVC insulated copper cables from ceiling rose to fitting including driver, lamp bracket made of 32mm bore galvanised iron light grade pipe made to shape having overall length not exceeding 1.5 mtr, through mild steel clamp of 25mm width and four Nos. nuts, bolts & washers of 12mm dia, 100mm long fixed to wall with all other fittings complete and testing all as specified and directed.
Fixing only ceiling fan 1200/1400 mm size in repair including necessary wiring and making electrical connection from ceiling rose to ceiling fan, testing the same for smooth operation complete all as specified and directed. NOTE: Cost of minor petty items if required such as nuts, bolts, clamp, bush etc., shall be included in quoted rate.
Supply & Fixing in repair ceiling fan 1200mm sweep complete with blades, down rod, electronic regulator, accessories (i.e. PVC canopy, rubber bush, split pin, hanging clamp, fan hook, holdfasteners etc.) 230 Volts, white colour, with min air delivery 210 CFM, BEE 5 star rated with brushless direct current motor (BLDC) technology and connecting up with & including 3 core flexible copper conductor cable from ceiling rose to ceiling fan complete all as specified and directed. Old fan shall be deposited in MES store yard.
Supply & Fixing in repair exhaust fan, heavy duty, steel body AC single Phase, 230V of size 300mm sweep, with blades and frame and louvers complete of make Havells/Crompton/Orient, fixed/grouted to wall with suitable bolts, nuts etc., and connecting up with & including 3 core flexible copper conductor cable from ceiling rose to exhaust fan including cutting hole suitable for fixing exhaust fan complete all as specified and directed. Old fan shall be deposited in MES store yard
Supply & fixing in repair exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, single phase, 1200 RPM, Copper winding of sweep 250mm complete of make Havells/Crompton/Orient, fixed/grouted to wall with suitable bolts, nuts etc., and connecting up with & including 3 core flexible copper conductor cable from ceiling rose to exhaust fan including cutting hole suitable for fixing exhaust fan complete all as specified and directed. Old fan shall be deposited in MES store yard
Fixing only of geyser (Electric Water heater storage type) of capacity 25 Lts, keep in safe custody after B/R repairs & wiring, with provn of new suitable MS bolts, PVC steel braided inlet/outlet connection pipe 15mm dia, 450mm long, 02 Nos. union, NRV, grouted to wall and making electrical connection to geyser, including cleaning of element, flanges, tank etc. and testing the same for smooth operation complete all as specified and directed. NOTE: Cost of minor petty items if required such as MS bolts, PVC steel braided inlet/outlet connection pipe 15mm dia, 450mm long with two numbers brass union, NRV, etc., including cleaning of element, flanges, tank etc., are included in quoted rate.
Supply and Fix in repair Storage water heater (Geyser) of 25 litre capacity 230V AC, 50HZ having element of 2 KW of COPPER/INCOLOY alloy , Rust proof outer body,high density PUF insulation, BEE 5 Star Rated and above ,Inner tank of SS 304 which can sustain pressure of minimum 8 Bar working pressure and having multifunction safety valve, making electric and water connection complete all as specified. Make AO Smith Model No HSE-VAS-X25 or equivalent in Racold/Havells or specified in PS..Old geyser shall be deposited in MES store yard
Material & Labour in repair for loadline distribution board, vertical, made out of sheet metal enclosure (CRCA sheet) dust and vermin proof, double door, VTPN 6 way, 415 volts grade with insulated rated bus bar assembly with isolated neutral bar,door earthing, earth bar IP- 43 protection with poly urithene (PU) gasketing, IK-08 Mechanical impact resistance, door earthing flush to wall, including testing suitable for fixing MCCB, MCB TPN/TP/SPN/SP etc, complete incl taking down old unsv one from site complete all as directed NOTE: (i) MCB DB & MCBs should be of same make as DB.. (ii) Necessary blank plates if required any to cover the blank MCB's place in DB and the rate shall be deemed to included in the quoted rate.
Supply & Fixing MCCB triple pole and neutral (four pole) 100 Amps, 415 volts, 50 Hz, having thermal setting range 70% to 100% and adjustable magnetic setting and breaking capacity 16 KA including making incoming and outgoing connections complete incl taking down old unsv one from site complete all as directed
Material & Labour in repair for distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof, double door, SPN 8 way, 240 volts grade with 200 Amps insulated rated bus bar with nickel plated brass, isolated neutral bar and door earthing, earth bar IP- 43 protection with poly urithene (PU) gasketing, IK-08 Mechanical impact resistance, flush to wall, including testing suitable for fixing MCB SPN, SP etc, complete all as directed NOTE: Necessary blank plates if required any to cover the blank MCB's place in DB and the rate shall be deemed to included in the quoted rates.
Supply & Fixing MCB of SP 5 to 32 Amps current carrying capacity, 240V, 10KA 'C' curve, ISI marked, fixed in the MCB DB complete conforming to IS/IEC-60898-1 2002 with connection testing and commissioning including taking down old unsv one from the site complete all as directed
All as per ser item No. 108 above but for MCB SPN 32 Amps
Supply and fixing sub main wiring with 2 runs of 6.0 sqmm single core, multi-stranded PVC insulated, FRLS unsheathed cable 1100 Volts grade with copper conductor drawn through and including concealed non metalic PVC conduit, medium grade, ISI marked, suitable size with conduit fittings and accessories concealed in wall/ceiling/floor including 1 run of 6.0 Sqmm multistranded PVC insulated FRLS, copper conductor cable as earth continuity conductor and connecting to common earth dolly incl taking down old unsv one from site complete all as directed NOTE: Two runs of 6.0 sqmm copper cable and one run of 6.0 sqmm copper cable alongwith non metallic PVC conduit/conduit accessories will be measured as one unit length
Material & Labourin repair for Earthing complete in replacement with galvanised iron mild steel earth plate electrode 60 cm x 60 cm x 6.3mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of earth plate at a depth of not less than 1.5 m below normal ground level, connected to glavanised earth lead of GI wire of size 4mm dia by means of GI Bolts, Nuts, check nuts & washers and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 25mm dia from earth plate to Panel/DBs and water pipe 20mm dia GI medium grade from top of the earth electrode raised upto a level of 50cm above ground level, MS funnel with wire mesh embeded in earthing pit of size 30x30x30cm in PCC (1:3:6) type C-1 incl exposed surfaces smoth finished with 15mm thick cement mortar (1:6), RCC pre-cast (1:2:4 type B-1) cover slab of 40mm thick with 2 Nos. MS handles of 12mm dia suitable for carrying of pit cover, Angle iron frame made out of 40x40x4mm angle iron for 30x30mm PCC pit for holding the pit cover including providing charcoal or coke and salt in alternative layers of 15 cm including necessary earth work in soft/loose soil, returning, refilling and removing of surplus soil to a distance n. exc. 50 mtr testing complete all as shown in electrical plate No-3 of MES Schedule Part-I of SSR-2009 complete all as specified and directed. NOTE: (a) Cost of excavation & earth work, watering pipe, test point, MS Funnel with wire mesh and PCC pit with cover shall be deemed to be included in the quoted rate. No extra cost shall be paid to the contractor against these items. (b) On testing after completion of job, if desired earth resistance is not obtained, the earthing shall be redone by the contractor & no extra cost will be given to the contractor.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
BOQ_836529.xls
BOQ • 0.36 MB
TENDER82.pdf
Tender Documents • 3.13 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .