Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.1 LAccepted-AOC H NO 309 REHARI COLONY JAMMU DISTT JAMMU J K 180005 | JAMMU | JAMMU AND KASHMIR | 180005 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹18.6 L+₹1.5 L (8.49%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹19.0 L+₹1.8 L (10.8%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹19.4 L+₹2.2 L (13.1%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹22.7 L+₹5.6 L (32.6%)Rejected-Finance C O OPPOSITE MH MANDA POONCH ROAD AKHNOOR 181201 J K | JAMMU | JAMMU AND KASHMIR | 181201 | L5 | Rejected-Finance Being other than L1 |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
7 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 862 EWS
GE 862 EWS PIN-913862 C/O 56 APO
Repair/Replacement of LT distribution system lightening protection security lights and misc repairs at Naushera Garrison
2020_MES_402515_1
GER-69/2020-21
Open Tender
Civil Works
Item Rate
270 days
GE 862 EWS
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹60,000
Yes
19 Jan 2021
10 Dec 2020
9 Jan 2021
10 Dec 2020
7 Jan 2021
24 Dec 2020
60 days
Amount
Dismantling of overhead ACSR conductor of any size including removing of PG Clamps jumpering etc and kept in safe custody for reuse serviceable ACSR in the work & removing unserviceable conductor from site complete all as specified and directed.
Dismantling of old unserviceable stay assembly including stay wire complete with necessary demolition of concrete excavation and earth work as reqd. and removing the same from site complete all as specified and directed.
Dismantling of old, unserviceable LT (PCC) concrete pole of any size with necessary demolition of concrete foundation including excavation, earth work as reqd complete all as specified and directed.
Dismantling of cross arms of MS channel or angle section etc complete fixed on RCC/steel tubular poles carefully including separating and stacking aside serviceable cross-arms for reuse in the work and removing unserviceable cross arms complete all as specified and directed.
Dismantling of insulators of any type & size from poles including separating & stacking aside serviceable insulators for reuse in the work & removing unserviceable insulator from site complete all as specified and directed.
Takig down old unserviceable LT cable any size from any position complete all as specified and directed.
Taking down old unserviceable GI pipe any size complete all as specified and directed.
Taking down old unserviceable Street / security light fitting any type and make complete all as specified and directed.
Taking down old unseviceable street / security light bracket any type complete all as specified and directed.
Taking down old unserviceable security light junction box any type/ size complete all as specified and directed.
Street light fitting LED 45 watt made up of grey powder coated pressure die cast aluminium housing having IP65 control gear and lens compartment. Fixture should have isolation in lense compartment and driver compartment and fitting must be top openable for easy maintenance and remain intact its IP protection forever after once it is open for repair. IP protection should be intacted for enhancing the overall efficiency of light. Fixture and driver should be of same make. Driver of the fixture must have enclosure and having vent from ends to prevent the driver from condensation effect and it should be BIS approved and R number should be mentioned on the top of the LED driver having voltage band of 110-300 Volts AC, THD <10% KV and also having surge protection inbuilt on driver is min 5KV and external SPD of 10KV outside the driver inside the fixture to prevent the fixture from non requirerd SUGRG. Driver should be equipped with over voltage short circuit and reverse polarity protections, driver must be constant current and constant voltage based (CVCT) fitting should having system efficiency of more than 100 lumens/watt. Fixture should be equipped with secondary lenses for better distribution of light. OEM must have its own manufacturing facility in regards to this OEM must produce the necessary documents of its own manufacturing along with the details of testing equipment and the respective Make : Crompton Cat Part No LSTP-45-CDLor techincally and commercially equivalent model of Havells/Wipro/Bajaj/C&S as approved by GE. Note :-1. Contractor shall obtain LM 79 and LM 80 test report (Electrical, photometry and chromaticity) (from third party NABL Lab only and inhouse NABL lab test will not be considered) for the light fitting from the manufacturer before supply of material and submit to the department. 2. A certificate of Guarantee shall be submitted by the contractor for period of 3 (three) years from the certified date of completion of work as a whole for repair/replacement of lamp and light fittings to GE. Performance guarantee amount @5% of quoted amount of LED lamp and light fittings shall be kept reserved for a period of three years. Accordingly ,performance guarantee amount shall be released after gaurantee period. 3. The manufacture LOGO shall be embossed into housing of luminaire. 4. Luminarie shall be provided with all parameters mentioned above. 5. Make of LED chip should be Cree, Nichia, Lumiled, Osram.
Street light fitting LED 60 watt made up of grey powder coated pressure die cast aluminium housing having IP65 control gear and lens compartment. Fixture should have isolation in lense compartment and driver compartment and fitting must be top openable for easy maintenance and remain intact its IP protection forever after once it is open for repair. IP protection should be intacted for enhancing the overall efficiency of light. Fixture and driver should be of same make. Driver of the fixture must have enclosure and having vent from ends to prevent the driver from condensation effect and it should be BIS approved and R number should be mentioned on the top of the LED driver having voltage band of 110-300 Volts AC, THD <10% KV and also having surge protection inbuilt on driver is min 5KV and external SPD of 10KV outside the driver inside the fixture to prevent the fixture from non required SURGE. Driver should be equipped with over voltage short circuit and reverse polarity protections, driver must be constant current and constant voltage based (CVCT) fitting should having system efficiency of more than 100 lumens/watt. Fixture should be equipped with secondary lenses for better distribution of light. OEM must have its own manufacturing facility in regards to this OEM must produce the necessary documents of its own manufacturing along with the details of testing equipment and the respective Make : Crompton Cat Part No LSTP-60-CDLor techincally and commercially equivalent model of Havells/Wipro/Bajaj/C&S as approved by GE. Note :-1. Contractor shall obtain LM 79 and LM 80 test report (Electrical, photometry and chromaticity) (from third party NABL Lab only and inhouse NABL lab test will not be considered) for the light fitting from the manufacturer before supply of material and submit to the department. 2. A certificate of Guarantee shall be submitted by the contractor for period of 3 (three) years from the certified date of completion of work as a whole for repair/replacement of lamp and light fittings to GE. Performance guarantee amount @5% of quoted amount of LED lamp and light fittings shall be kept reserved for a period of three years. Accordingly ,performance guarantee amount shall be released after gaurantee period. 3. The manufacture LOGO shall be embossed into housing of luminaire. 4. Luminarie shall be provided with all parameters mentioned above. 5. Make of LED chip should be Cree, Nichia, Lumiled, Osram.
Supply,fixing, connecting, testing and commissioning LED flood light fittings 100 watt made up of grey powder coated pressure die cast aluminium housing having IP 65 control gear and lens compartment. Fixture should have isolation in lens compartment and driver compartment and fittingh must be top openable for easy maintenance and remain intact its IP protection forever after once it is open for repar. IP protection should be intacted for enchancing the overall efficiency of light. Fixture and driver should be BIS approved and R number should be mentioned on the top the LED driver having voltage band of 240 volt AC, CRI>70,life hours >50000, bracket mounted , having color temperature 5700K , THD<10% KV and also having surge protection in built on driver is min 5KV & external SPD of 10 KV outside the driver inside the fixture to prevent the fixture from non required SURGE. Driver should be equipped with over voltage short circuit & reverse polarity protections, driver must beconstant current & constant voltage based (CVCT) fitting should having system efficicency of more than 88 lumens/watt. Fixture should be equipped with secondary lenses for better distribution of light. OEM must have its own manufactureing facility in regards to this OEM must produce the necessary documents of its own manufacturing along with the details of testing equipement and the respective complete all as specified and directed. Make Crompton Cat No LFLN-100-CDL/60 or techincally and commercially equivalent model of Havells/Wipro/Bajaj/GE/Syska/Surya as approved by GE. Note : (i) Contractor shall obtain LM 79 & LM 80 test report (Electircal, Photometry& Chromaticity) (from third party NABL lab only and inhouse NABL lab trest will not be considered) for the light fitting from the manufacturer before supply of material and submit to the department. (ii) A certificate of Gurrantee shall be submitted by the contractor for period 3 (three) years from the certified date of completion of work as a whole for repair/replacement of lamp & light fittings to GE. Performance guarantee amount @ 5% of quoted amount of LED lamps & light fitting shall be kept reserved for a period of three years. Atlernatively after completion of work contractror may furnished guarantee amount in the shape of FDR/BGB pleased in favour of GE. (iii) The manufacture LOGO shall be embossed into housing of luminaire. (iv) Luminarie shall be provided with all parameters mentioned above. (v) Make of LED chip should be cree, nichia, lumiled and osram.
Street light bracket made out of 40mm bore GI medium grade pipe 1.2 mtr long bend to shape 120 degree and fixing with 2 Nos of MS clamps of 50mm x 6mm thick flat iron including nuts, washers, bolts complete fitting arrangements suitable for any type of poles complete all as specified and directed.
Aluminum conductor steel reinforced (ACSR), stretched on LT poles without any kink and bends of various sizes complete including fixing to insulator with copper binding wire and coloured sleeved jumper connection with PG clamps all as specified and directed by Engineer-in-Charge. Note: The conductor shall be squirrel/weasel/DOG/Beaver.
Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of synthetic enamel paint all ass specified and directed.
Re fixing of serviceable cross arm obtained from sl item No 04 cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of synthetic enamel paint including preparation of surfaces complete all as specified and directed.
Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 50mm height, 65mm dia for 1100 volts grade all as specified and directed.
Shackle type porcelain vitreous brown or white insulator for working pressure 1100 volts 90 mm dia x 75mm high including galvanized mild steel straps 31x3 mm and 12mm dia bolts, washers and nuts complete all as specified and directed.
Stay assembly comprising of 300 mm x 300mmx6mm thick galvanized mild steel stay plate, galvanized iron stay rod of 20mm dia 1800mm long, galvanized thimble, stay strand galvanized wire 7/3.15mm, GI nuts,bolts and washers as shown on electrical plate No 1 of SSR Part-I complete all as specified and directed by the Engineer-in-Charge. Note:- Loop type insulators, excavation, earth work and PCC will be measured & paid for separately.
Junction box of size 30X25X15cm made out of 16 gauge MS sheet weather proof including one coat of red oxide primer and two coat of synthetic enameled paint and fixing arrangement etc using suitable clamps nuts, bolts etc for fixing and comprising of following accessories:- a) Two strip aluminium bus bar of capacity 63 A, including and mounted on epoxy insulators-01 Set b) MCB SP 6 Amps-01 No
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth not exceeding 10sqm on plan for laying of cable and foundation of poles stays and getting out in soft / loose soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5 m depth not exceeding 10sqm on plan for laying of cable and foundation of poles stays and getting out in soft / loose soil complete all as specified and directed. .
Dry sand cushioning to underground cable, provided with a layer 8 cm thick before and 15 cm deep after laying and stretching jointing and testing the cable complete all as specified and as directed Note: Punned thickness of sand shall be measured and paid.
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 10 sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts including removing old unserviceable cable complete all as specified and directed.
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts including removing old unserviceable cable complete all as specified and directed.
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 25 sqmm 4core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts including removing old unserviceable cable complete all as specified and directed.
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 50 sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts including removing old unserviceable cable complete all as specified and directed.
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 95 sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts including removing old unserviceable cable complete all as specified and directed.
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 120 sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts including removing old unserviceable cable complete all as specified and directed.
Returning, filling in trenches including spreading, leveling watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.
Removing of excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and directed by Engineer-in-Charge.
Brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat, size 230mm x 115mm x 75mm, complete all as specified and as directed.
Steel tubular swaged poles errected to truly vertical or planted as strut complete with 6mm thick mild steel base plate, welded to Pole, B-118 finial taper cap, bolts, nuts and screws, poles made out of ERW MS tubing conforming to IS-2713 Part-II, type 410-SP-31 (9m long) including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bituminous paint internally and portion embedded in concrete, making five black and white bands at lower portion of pole each 300mm wide alternately and marking pole number. with black paint at suitable height complete all as specified and directed .
PCC 1:4:8 (nominal mix) type D-2 using 40mm graded crushed stone aggregates, as in foundation filling and mass concrete of poles and stay/installation paths complete all as specified and directed.
PCC 1:3:6 (nominal mix) type C-1 using 20mm graded crushed stone aggregate as in coping of poles and the like complete including weathering, slightly rounded or chamfered angles and throating all as specified and directed.
PCC 1:2:4 (nominal mix) type B-2 using 40mm graded crushed stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
GI water tubing light grade, 40 mm bore for mechnical protection of cable including sealing ends of pipe with bitumenous preformed wooden wedge complete all as specified and directed.
GI water tubing light grade, 50 mm bore for mechnical protection of cable including sealing ends of pipe with bitumenous preformed wooden wedge complete all as specified and directed.
Sub main wiring with two runs of single core PVC insulated and unsheathed multistranded (FRLS) copper conductor cable of size 1.50 Sqmm LT, 1100 volts grade, drawn through and including 25 mm dia or higher PVC non metallic conduit pipe with accessories including provision of suitable size of clamp for fixing conduit pipe with steel / PCC pole etc.and one run of 1.5 sqmm single core multistranded copper conductor cable green colour as earth continuity conductor with suitable lugs made of copper connected to earth dolly including taking out existing unservuceable sub main wiring complete all as specified and directed..
Painting to existing poles 9.00 mtr long including cross arms, angles nuts and bolts with two coats of synthetic enamelled aluminium paint of superior quality with alternative strips of black and yellow paints (strip 30cm) upto height of 1.50 mtr from concrete portion and numbering of pole using 8 cm bold letters with black and yellow painted circle including preparation of surfaces complete all as specified and directed.
Restretching of existing ACSR conductor on LT overhead line of any size and type of span of 1x5 Nos of conductor wires, length 40 to 50mtr approximate of each span including 1 run of GI earth wire 4mm dia and including making the jumpher connections and including cutting, trimming tree branches of various length to keep a clear distance 2 mtr from the pole and depositing the cut branches upto 50 mtr from the pole including taking down shut down in writing all as directed by Engr-in-Charge.
MCCB four pole adjustable thermal and magnetic setting type, 400 Amp rating, 36 KA breaking capacity, 415 volts, 50 Hz including taking down old unserviceable MCCB any make and provision of suitable size of lugs for existing cable complete all as specified and directed.
MCCB four pole adjustable thermal and magnetic setting type, 320 Amp rating, 36 KA breaking capacity, 415 volts, 50 Hz including taking down old unserviceable MCCB any make and provision of suitable size of lugs for existing cable complete all as specified and directed.
MCCB four pole adjustable thermal and magnetic setting type, 200 Amp rating, 36 KA breaking capacity, 415 volts, 50 Hz including taking down old unserviceable MCCB any make and provision of suitable size of lugs for existing cable complete all as specified and directed.
MCCB four pole adjustable thermal and magnetic setting, 160 Amp rating, 25 KA breaking capacity, 415 volts, 50 Hz including taking down old unserviceable MCCB any make and provision of suitable size of lugs for existing cable complete all as specified and directed.
MCCB four pole fixed thermal and magnetic setting type, 100 Amp rating, 25 KA breaking capacity, 415 volts, 50 Hz including taking down old unserviceable MCCB any make and provision of suitable size of lugs for existing cable complete all as specified and directed.
MCCB four pole fixed thermal and magnetic setting type, 63 Amp rating, 25 KA breaking capacity, 415 volts, 50 Hz including taking down old unserviceable MCCB any make and provision of suitable size of lugs for existing cable complete all as specified and directed.
House service bracket hook type 3.0 mtr long, GI pipe 40 mm bore medium grade , two Nos 90 degree bends MS hook and stay or guy including taking out or unserviceable bracket and making good as per existing complete all as specified and directed.
1100 Volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hangers not more than 1.0 mtr apart including 4 mm suspension wire one twin core cable flat or circular stranded aluminium conductor of 10 sq mm size including out old unserviceable service connections complete all as specified and directed.
Repairing of LED security light fittings of ratings upto 30 Watts by replacement of suitable size and model of LED driver surge protection device of suitable capacity including testing complete all as specified and directed. Note : Unserviceable LED light issued from MES store yard and same to be return to store after repairing.
Repairing of LED security light fittings of ratings upto 45 Watts by replacement of suitable size and model of LED driver surge protection device of suitable capacity including testing complete all as specified and directed. Note : Unserviceable LED light issued from MES store yard and same to be return to store after repairing.
Repairing of LED security light fittings of ratings upto 60 Watts by replacement of suitable size and model of LED driver surge protection device of suitable capacity including testing complete all as specified and directed. Note : Unserviceable LED light issued from MES store yard and same to be return to store after repairing.
Supply and fixing in replacement LT line separator for 3 line wire system complete all as specified and directed.
Supply and fixing in replacement LT line separator for 4 line wire system complete all as specified and directed.
Supply and fixing in replacement LT line separator for 5 line wire system complete all as specified and directed.
Synthetic Insulating Mat , ISI Marked , one side plain and other side chequered, of of size 2.00mtr x1.00mtr x 12mm thickness complete all as specified and directed.
Synthetic Insulating Mat , ISI Marked , one side plain and other side chequered, of of size 2.00mtr x1.00mtr x 19mm thickness complete all as specified and directed.
Cutting/trimming of tree branches under OH HT/LT electric line including cleaning upto 1.00 mtr horizontal distance on both sides of OH electric line from ground level of the poles including removing all creepers small bushes etc of under OH line upto 60 mtr each span complete all as specified and directed. Note :- Materials/T&P like Axes, rope and the like will be provided by the contractor without any extra cost to the Govt
Air terminal single pointed aluminium rod 12mm dia 300 mm long complete all as specified and directed.
Test terminal block made of gun metal or phosphorus bronze size 75 x 75x 25 mm drilled and scrwed including 3 Nos 8mm dia 25mm long hex, head screw complete all as specified and directed.
Aluminium strip 25x3.15mm with saddles and fixing screws etc for roof conductors and down conductors above ground levle complete all as specified and directed.
GI pipe 40mm dia light grade for fixing of air termination complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m deep below normal ground level connected to and including 32X6mm thick galvanised iron strip by means of bolts, nuts, checknuts and washers of galvanised iron or steel all as specified in electrical plate No 3 of SSR (2009) part-I including 40mm bore GI pipe light grade for protection of earth strip and PCC 1:2:4 type B-1 as in pit, Precast RCC earth pit cover 8 cm thick reinforced with 8mm dia TMT bars @150mmc/c and two handles, excavation and earth work in any type of soil and alternate layers of charcoal, common salt and 20mm bore galvanised medium grade steel tubing for watering with one end fixed with cast iron funnel and wire mesh and testing on completion complete all as specified and directed. Note:-Earth strip and protection pipe upto board is included in the rate quoted.
Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m deep below normal ground level connected to and including 4mm dia galvanised iron earth wire by means of bolts, nuts, checknuts and washers of galvanised iron or steel all as specified in electrical plate No 3 of SSR (2009) part-I including 15mm bore GI pipe light grade for protection of earth wire and PCC 1:2:4 type B-1 as in pit, Precast RCC earth pit cover 8 cm thick reinforced with 8mm dia TMT bars @150mmc/c and two handles, excavation and earth work in any type of soil and alternate layers of charcoal, common salt and 20mm bore galvanised medium grade steel tubing for watering with one end fixed with cast iron funnel and wire mesh and testing on completion complete all as specified and directed. Note:-Earth wire and protection pipe upto board is included in the rate quoted.
Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents.
M/S Darshan Kumar
Jiwan Singh
M/S PARSHOTAM KUMAR GUPTA
Usha Engineering Co.
Kay Bee Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .