| 1 | L1₹33.2 LAccepted-AOC 1723 GUPTA AND SONS SECTOR 39 B CHANDIGARH CHANDIGARH CHANDIGARH 160036 UDYAM CH 01 0042756 | CHANDIGARH | CHANDIGARH | 160036 | ₹33.2 L Quoted ₹34.8 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹39.4 L+₹4.7 L (13.4%)Rejected-AOC 411 STREET NO 4 PANCHVATI NAGAR BATHINDA 151001 | BATHINDA | PUNJAB | 151001 | ₹39.4 L+₹4.7 L (13.4%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹44.9 L+₹10.1 L (29.0%)Rejected-AOC HOUSE NO 3363 SECTOR 27 D CHANDIGARH | NA | NA | 160001 | ₹44.9 L+₹10.1 L (29.0%) | L3 | Rejected-AOC Rejected |
| Sl No | Description | Qty | Unit | M/S Gupta and Sons L1 | M/s Super Trading Corporation L2 | His Construction Company L3 |
|---|---|---|---|---|---|---|
| 1.00 | Excavating in post holes (or similar holes) each not exceeding 0.5 cum, getting out, returning, filling in and ramming earth, in layers not exceeding 25cm, watering, and removing surplus spoil to a distance not exceeding 50m and making good surface all as specified and directed by Engineer - in - Charge. | 16 | Each | 50 ₹800 Lowest | 150 ₹2,400 | 100 ₹1,600 |
| 2.00 | M&L Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete and sub base all as specified and directed by Engineer - in - Charge | 15 | Cum | 2,500 ₹37,500 | 1,800 ₹27,000 | 1,500 ₹22,500 Lowest |
| 3.00 | M & L for 75mm thick cement concrete type C-2 (1:3:6) using 40mm graded stone aggregate as in plinth protection etc all as specified and directed by Engineer - in - Charge. | 70 | Sqm | 200 ₹14,000 Lowest | 250 ₹17,500 | 250 ₹17,500 |
| 4.00 | M & L 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 15mm thick cement mortar 1:4 all as specified and directed by Engineer - in - Charge . | 15 | Sqm | 1,800 ₹27,000 Lowest | 2,200 ₹33,000 | 2,500 ₹37,500 |
| 5.00 | Extra over Granite or marble slabs as in rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations etc complete all as directed. all as specified and directed by Engineer - in - Charge. | 12 | RM | 60 ₹720 | 100 ₹1,200 | 50 ₹600 Lowest |
| 6.00 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete.all as specified and directed by Engineer - in - Charge. | 150 | Sqm | 600 ₹90,000 | 550 ₹82,500 Lowest | 650 ₹97,500 |
| 7.00 | Demolition of brick work built in cement mortar all as specified and directed by Engineer - in - Charge. | 10 | Cum | 150 ₹1,500 Lowest | 450 ₹4,500 | 250 ₹2,500 |
| 8.00 | M&L Brick work with sub class 'B' old size burnt bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 all as specified and directed by Engineer - in - Charge . | 10 | Cum | 3,500 ₹35,000 Lowest | 4,000 ₹40,000 | 4,200 ₹42,000 |
| 9.00 | Providing and fixing factory made uPVC white colour casement (Openable) Door made of extruded profile wilh wall thickness of 2.3mm ( + -0.2mm). Window profile with hollow section with mitlti chamber, frame (60mm x 58mm), sash (60mm x 78mm). T profile (One vertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling ol holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 + -0.2mm thick galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27mm), T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall wilh 8mm x 100mm long fasteners. Hardware: [casement door handle made of zinc alloyed (white powder coated).Corner striker. Secondary Strikers. Cylinder. Door transmission gear made of mild sleel with multi point locking system with strikes. 3D Hinges of zinc alloyed (white powder coated) [and 5mm thick glazing with selected quality glass. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose.) | 15 | Sqm | 6,000 ₹90,000 Lowest | 9,500 ₹1,42,500 | 8,000 ₹1,20,000 |
| 10.00 | Providing and fixing factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware.EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured for payment purpose.) (A) Area not exceeding 2.00 sqm each . | 35 | Sqm | 6,000 ₹2,10,000 Lowest | 9,500 ₹3,32,500 | 9,500 ₹3,32,500 |
Tender Value
₹49.1 L
EMD Value
₹98,300
Closing Date
5 Jul 2025, 6:00 pmClosed
Garrison Engineer
GE (U) Chandimandir Pin-134107
CA NO GE(U)/CHM-10/2025-26 SPL REPAIR TO BLDG NO CH 103 MRI CENTRE AT COMMAND HOSPITAL (WC) CHANDIMANDIR
2025_MES_709617_1
GE(U)/CHM-10/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE (U) Chandimandir
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE (U) Chandimandir
₹98,300
Yes
29 Aug 2025
22 May 2025
9 Jul 2025
22 May 2025
5 Jul 2025
21 Jun 2025
Amount
Excavating in post holes (or similar holes) each not exceeding 0.5 cum, getting out, returning, filling in and ramming earth, in layers not exceeding 25cm, watering, and removing surplus spoil to a distance not exceeding 50m and making good surface all as specified and directed by Engineer - in - Charge.
M&L Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete and sub base all as specified and directed by Engineer - in - Charge
M & L for 75mm thick cement concrete type C-2 (1:3:6) using 40mm graded stone aggregate as in plinth protection etc all as specified and directed by Engineer - in - Charge.
M & L 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 15mm thick cement mortar 1:4 all as specified and directed by Engineer - in - Charge .
Extra over Granite or marble slabs as in rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations etc complete all as directed. all as specified and directed by Engineer - in - Charge.
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete.all as specified and directed by Engineer - in - Charge.
Demolition of brick work built in cement mortar all as specified and directed by Engineer - in - Charge.
M&L Brick work with sub class 'B' old size burnt bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 all as specified and directed by Engineer - in - Charge .
Providing and fixing factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware.EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured for payment purpose.) (A) Area not exceeding 2.00 sqm each .
S & F steel work in tubular trusses etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS-1161-1979 (grade st-240) all as specified and directed by Engineer - in - Charge.
M&L rolled mild steel plates (Plain or chequered) Fe 410-W (Gde E- 250 ), quality-B, channels, square cut or notched (ordinary and counter sunk) forming holes without any attachment complete all as specified and as directed by Engineer-in-Charge.
M & L providing two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces including preparation of surface of any description over 10 cm width or girth all as specified and directed by Engineer - in - Charge .
S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet of mangalore pattern 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws all as specified and directed by Engineer - in - Charge.
S & F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws all as specified and directed by Engineer - in - Charge.
Supplying and fixing metal false ceiling of approved materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams/sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 15X32 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 15X32 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 15X32 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm.
And fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm dia GI wire spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Anakon Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.
S&F PVC wall panelling, solid cored, 5mm thick, decorative designs with smooths surfaces, fire resistant, water and heat proof, tongue and groove edge for easy assembly with all accessories such as U cap, end cap, tee, plugs, fillets and screws etc as per manufactures instructions and fixing complete all as specified & directed by Engineer - in - Charge.
S&F door closer hydraulically regulated, aluminium (extruded section) body, designation No. 3, universal type suitable for door shutter upto 1000mm in width and of weight 61 to 80 kg complete all as specified and as directed by Engineer-in-Charge.
S & F double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed by Engineer - in - Charge .
M & L two coats of distemper oil emulsion over a coat of primer and wall putty (Asian / JK / Birla), preparatory to distempering, on newly plastered surfaces of walls including preparation of surfaces all as specified and directed by Engineer - in - Charge.
M & L two coats of white wash including preparing new plastered or unplastered surfaces of walls complete all as specified and directed by Engineer - in - Charge.
M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over plastered or unplastered or concrete surfaces including preparation of new surfaces complete all as specified and as directed by Engineer-in-Charge.
M & L one coat of white wash on old decorated plastered or unplastered surfaces of ceiling including preparation of surfaces complete all as specified and directed by Engineer - in - Charge .
M & L two coats of distemper oil emulsion over a coat of wall putty (Asian / JK / Birla), preparatory to distempering on old surfaces after complete removal of existing treatment all as specified and directed by Engineer - in - Charge.
M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over plastered or unplastered or concrete surfaces including preparation of surfaces by removal of existing treatment complete all as specified and as directed by Engineer-in-Charge.
M & L for 4mm thick ACP sheet of approved color as in doors, windows and partitions fixing with uPVC beading or as per manufacturer's instruction including joint filling and tapping with necessary arrangement complete all as specified and directed by Engineer - in - Charge.
M & L rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even & fair without using extra cement all as specified and directed by Engineer - in - Charge . Note:- The rates do not include for the supply of integral water proofing compound, which shall be paid for in addition at “supplied only rates separately, as applicable.
Supply only liquid integral water proofing compound, complete all as specified.
M & L rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finished even & fair without using extra cement all as specified and directed by Engineer - in - Charge .
M & L rendering 5mm thick on fair faces of brick work or concrete surfaces on ceiling in CM 1:3 finished even & fair without using extra cement all as specified and directed by Engineer - in - Charge .
S & F framed work such as grills, grating, etc., with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work for water tanks and similar work conforming to Fe-290 Gde E-165 all as specified and directed by Engineer - in - Charge.
M & L for non skid ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white cement paste pigmented to tile shade over and including 15mm thick cement and sand screed (1:4) complete all as specified and directed by Engineer - in - Charge.
M & L for glazed ceramic coloured tiles 7mm thick 300 x 450mm size in vertical surface set and jointed in neat cement slurry and pointed in white cement paste pigmented to the shade over and including 10mm thick cement sand plaster (1:3) complete all as specified and directed by Engineer - in - Charge.
M& L dark shade/Double Charged/ultracharged Vitrified Ceramic coloured tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick Screed bed or bedding layer of mortar for laying floor finishes in CM 1:4 complete all as specified and directed by Engineer - in - Charge.
All as per Srl item No. 35 here-in-before but on vertical surface such as skirting, dado over and including 10mm thick cement sand plaster (1:4) etc complete all as specified and directed by Engineer - in - Charge.
M & L 25 mm thick Cement Conrete 1:2:4 type B–0 using 12.5mm graded stone aggregates flooring finished even and rough to receive topping layer all as specified and directed by Engineer - in – Charge .
Taking down steel tubing 15mm bore and connections including cleaning for refixing/ removal complete all as specified and directed by Engineer - in – Charge.
S & F 15mm bore medium grade steel tubes galvanised with all fittings and fixed complete to walls & ceiling or laid in floor all as specified and directed by Engineer - in – Charge .
Taking down steel tubing 20mm bore and connections including cleaning for refixing/ removal complete all as specified and directed by Engineer - in – Charge.
S & F 20mm bore medium grade steel tubes galvanised with all fittings and fixed complete to walls & ceiling or laid in floor all as specified and directed by Engineer - in – Charge .
S & F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified
S&F as in repairs WC squatting pan “Orissa Pattern” of size 580 x 440mm white with integral foot rest (excluding flushing cistern & flush pipe) including connection to trap and to flush pipes etc and lime concrete bedding complete all as specified in SSR and including trap set complete all as specified and directed.
S&F as in repairs PVC flushing cistern 10 ltr capacity valve less syphonic action type low level with and incl ball valve float & handle, waste pipe & brackets complete set complete all as specified and directed.
S & F as in repair vitreous china wash basin, white, flat back, size 550x400mm including waste fitting brass chromium plated, PVC connection and PVC waste pipe and fixing with new brackets including cutting and pinning in ends of brackets complete all as specified and directed by Engineer - in – Charge .
S&F as in repairs PVC (SWR), soil waste and vent pipes, single socketed, 110mm dia bore in any length with rubber ring joints, fixed to walls, laid in trenches or in floors'complete all as specified and directed
S&F as in repairs PVC (SWR), soil waste and vent pipes, single socketed, 75mm dia bore in any length with rubber ring joints, fixed to walls, laid in trenches or in floors'complete all as specified and directed
S&F PVC (SWR) bends any radius bore of 75 mm with access door all as specified and directed by Engineer - in - Charge
S&F PVC (SWR) bends any radius bore of 110 mm with access door all as specified and directed by Engineer - in - Charge
S & F as in repairs stack clamps for 100 mm bore pipe out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof all as specified and directed by Engineer - in - Charge.
S & F as in repairs stack clamps for 75 mm bore pipe out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof all as specified and directed by Engineer - in - Charge.
S & F as in repairs vitreous china wash down water closet pan (Pedestal Pattern), white including plastic water closet seat cover, black, closed pattern with flat bottom with mild steel chromium plated or aluminised hinging device and fixing with all joints to WC pan all as specified and directed by Engineer - in - Charge .
S&F as in repairs Pillar taps 15mm bore dia, fancy type, cast copper alloy with capstan heads chromium plated screwed down hidh pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts screwed for iron pipe and fixed all as specified and directed by Engineer – in – Charge .
S & F as in repairs soap dish brass chromium plated, fixed to plugs with brass chromium plated screws complete all as specified and directed by Engineer - in - Charge.
S & F as in repairs PVC flexible waste pipe of standard length 25mm dia. with PVC cap suitable for waste coupling all as specified and directed by Engineer - in - Charge .
S&F in repairs 1000 litres capacity rotational moulded polye-thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I with and including 20mm bore dia Ball brass valves, high pressure, with polythene float and flynut complete,screwed for iron pipe or brass ferrule and fixed etc complete all as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets all as specified and directed by Engineer - in - Charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc 1.50 Sqm each complete all as specified and as directed by the Engineer-in-Charge
Taking down chowkhats or frames with shutters without taking off shutters from the frame exceeding 1.5 Sqm but not exceeding 4 Sqm each and all as specified and directed by Engineer - in - Charge.
Dismantling floor or wall tiles including cement mortar bedding, removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer - in – Charge.
Taking down cement plaster/ terrazo finish on brick wall including racking out joints, hacking for keys scrubbing down with water all as specified and directed by Engineer - in - Charge.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons Laid, bedded and pointed in any mortar etc.all as specified and directed by Engineer - in - Charge .
Demolition of cement concrete (un-reinforced) in floors / pavings, (below or above ground level) and of any description and in any position not otherwise specifically provided for all as specified and directed by Engineer - in - Charge .
Dismantling wrought iron or mild steel work of any description all as specified and directed by Engineer - in - Charge .
Dismantling PVC fibre sheeting, any gauge, thickness, all as specified and directed by Engineer - in - Charge.
Taking down carefully old and unserviceable aluminium/ copper point wiring for light/fan/socket or power point complete including fittings such as switches, ceiling rose, pendents, regulators, sockets, bell, distribution boards and MCB's etc and making good disturbed surface of walls, floors etc to match with the existing surface complete all as specified and directed.
Point wiring complete with 1.5 sq.mm PVC insulated unsheathed multi-stranded FRLSH grade copper conductor 1100 V grade drawn through and including non-metallic rigid 25 mm dia PVC conduit, medium grade, including conduit accessories, concealed in walls and terminated to and including provision of modular metal flush boxes (made out of 1.6 mm thick MS sheet), modular metal frame plate and white cover for switches, sockets / regulators etc., including 1.5 Sq.mm PVC insulated unsheathed multi-stranded FRLSH grade copper conductor cable as earth continuity conductor and connecting to common earth dolly with brass screws, washers etc., complete all as specified and directed for one light point controlled by modular switch 6 Amp, single pole, one way, 240V, complete all as specified. Note:- (i) The quoted rate shall deemed to include the cutting chases and making good to match with the existing surfaces. (ii) Modular metal boxes and modular white cover with frame etc is included in quoted rates. (iii) Provn of blank plates as per site requirement.
All as per Srl item No. 67 here-in-before but one ceiling fan/ exhaust fan point controlled by modular switch 6 Amp, single pole, one way, 240V, complete all as specified.
All as per Srl item No. 67 here-in-before but one 05 Amp socket outlet point on independent board controlled by modular switch, 6 Amp, single pole, one way, 240V, complete all as specified and directed.
All as per Srl item No. 67 here-in-before but one bell point controlled by modular bell push switch 6 Amp, single pole, one way, 240V, complete all as specified.
All as per Srl item No. 67 here-in-before but one 05 Amp socket outlet point on same board controlled by modular switch 06 Amp, single pole, one way, 240V, complete all as specified and directed.
All as per Srl item No. 67 here-in-before but one light point controlled by modular switch, 6 Amp, single pole, two way, 240V, complete all as specified and directed.
All as per Srl item No. 67 here-in-before but with 2.5 Sqmm single core multi stranded copper conductor of 1100 volts grade PVC FRLS insulated and sheathed cable for socket outlet 15 Amps including 2.5 Sqmm single core solid copper conductor 1100 volts grade PVC insulated and sheathed cable as earth continuity conductor to common earth and connecting to earth dolly.
All as per Srl item No. 67 here-in-before but with 4 Sqmm single core multi stranded copper conductor of 1100 volts grade PVC FRLS insulated and sheathed cable for AC/ geyser point including 4 Sqmm single core solid copper conductor 1100 volts grade PVC insulated and sheathed cable as earth continuity conductor to common earth and connecting to earth dolly.
S&F Modular switch 1 way 6A, 1 module, one way all as specified and directed by Engineer - in – Charge.
S&F Modular switch 1 way 16A, 1 module, one way all as specified and directed by Engineer - in – Charge.
S&F Modular Bell push 6A, 1 module, single pole one way, all as specified and directed by Engineer - in – Charge .
S&F switch modular two way 6A, 1 module all as specified and directed by Engineer - in – Charge.
S&F electric call bell/ buzzer, AC, 230 volts, single pole, complete all as specified and as directed by Engineer-in-Charge.
S&F modular socket, 6A - 2/3 pin combined 2 module all as specified and directed by Engineer-in –Charge.
S&F modular socket 6A/16A - 2/3 pin combined 2 module all as specified and directed by Engineer-in –Charge.
S&F modular fan step type regulator, 120W - 2 module all as specified and directed by Engineer-in –Charge.
M & L ceiling rose 65 x 50mm three terminals PVC/ polycorbonate, isolated body all as specified and directed by Engineer - in - Charge .
Supply and fixing as in replacement LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.
Supply and fixing as in replacement LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
Supply and fixing as in replacement LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing as in replacement LED street light fitting 30 Watt, 230 V AC outdoor type with high pressure die, cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
S&F as in repairs sheet metal enclosure distribution board triple pole and neutral (TPN) 8 way, double door, 415 volt all as specified and directed by Engineer-in- Charge.
S&F as in repairs sheet metal enclosure distribution board single pole and neutral (SPN) 12 way, double door with 200 Amp rated busbar 240 Volt all as specified and directed by Engineer-in- Charge.
S&F as in repairs VTPN DB 8 way with MCCB as incomer ,metal door, ready to use DBs provided with Neutral Bar, Mechanical Impact Strength IK 08 , Insulated busbar assembly, cement spill protector, color-coded interconnecting wire set, cable ties blanking plates and circuits identification labels suitable for 3 pole and 4 pole MCCB's upto 125 Amp as Incommer and MCBs (TP/SP) as outgoing, IP 43 protection, conforming to IS 8623-1 & 3, IEC 61439-1 & 3 including complete all as specified and directed. Note:- (i) MCB's and MCCB's shall be measured and paid separately.
S&F as in repairs MCCB 125 Amp, 415 Volt, 4 Pole, Ics=100% of Icu with spreader & rom,16 KA complete all as specified and directed.
S&F as in repairs MCB Three Pole and Neutral (TPN) 63-100 Amps, 415 Volt, 'C' Curve with rupturing capacity not less than 10 KA all as specified and directed by Engineer– in– Charge.
S&F as in repairs MCB Single Pole and Neutral (SPN) 40-100 Amps, 240 Volt, 'C' Curve with rupturing capacity not less than 10 KA all as specified and directed by Engineer– in– Charge.
S&F as in repairs MCB Single Pole 06-32 Amps, 240 Volt, 'C' Curve with rupturing capacity not less than 10 KA all as specified and directed by Engineer– in– Charge.
Supply and fixing RCBO single pole and neutral (SPN), 32-63 Amps, 240 Volts, electromechanical DP RCBOs used as SPN/ DP RCBOs with rupturing capacity not less than 10 KA and IS 12640-2 & IEC 61009-1 all as specified and directed.
Supply and fixing as in replacement single pole and neutral enclosures with two pin and earth plug and socket complete with double pole MCB 240 V 20 Amps all as specified and directed by Engineer - in - Charge.
Taking down ceiling fans/ wall fans of any size for servicing by cleaning dust, filling cavities with filler and oiling/greasing and re-fixing the same in position, connecting and testing all as specified and directed.
Taking down exhaust/ ventillation fans of any size for servicing by cleaning dust, filling cavities with filler and oiling/greasing and re-fixing the same in position, connecting and testing all as specified and as directed.
Taking down existing Split/Window/Tower AC of 1.0/1.5/2.0/5.0 TR capacity for servicing by water cleaning dust, filling cavities with filler complete and re-fixing the same position after completion of civil work, connecting and testing complete carefully, all as speciied and directed.
S & F in repairs submain wiring with four single core cables PVC FRLS insulated unsheathed 16 Sqmm stranded copper conductor drawn in and including PVC conduit with and including PVC FRLS insulated one single core cables 16 Sqmm stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer - in - Charge. Note : PVC cables four single core and one single core of sizes as mentioned will considered as one unit.
S & F in repairs submain wiring with four single core cables PVC FRLS insulated unsheathed 10 Sqmm stranded copper conductor drawn in and including PVC conduit with and including PVC FRLS insulated one single core cables 10 Sqmm stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer - in - Charge. Note : PVC cables four single core and one single core of sizes as mentioned will considered as one unit.
S & F in repairs submain wiring with four single core cables PVC FRLS insulated unsheathed 6 Sqmm stranded copper conductor drawn in and including PVC conduit with and including PVC FRLS insulated one single core cables 6 Sqmm stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer - in - Charge. Note : PVC cables four single core and one single core of sizes as mentioned will considered as one unit.
M & L as in repairs submain wiring with two single core cables PVC FRLS insulated unsheathed 4 Sqmm stranded copper conductor drawn in and including PVC conduit with and including PVC FRLS insulated 4 Sqmm stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer - in – Charge. Note : PVC cables two single core and one single core of sizes as mentioned will considered as one unit.
Earthing complete with GI earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth strip of size 25 mm x 4 mm by means of bolts, nuts, washers of galvanised iron or steel, GI earth strip shall be protected by 40mm dia GI pipe 'medium grade', watering pipe 20mm dia GI pipe 'light grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL, and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 50mm thick RCC cover (1:2:4) type B1 mix with 8mm dia nominal reinforcement @ 100mm c/c both ways etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciified and as directed.
NOTE:- (a) Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. (b) Rate quoted shall deemed to include GI earth strip and GI protection pipe light grade. (c) Rate quoted shall deemed to include taking down old items. (d) Minimum 100 Kg salt and 100 Kg charcoal granual type to be used for each earth pit. The bed to be done in 3 x 15 cm depth of salt and 3 x 15 cm depth of charcoal in aternate. (e) PVC type DC insulators with screws, nuts, bolts etc to be used in suface/wall/floor for mounting of strip and distance between two insulator shall not be less than 1.0 mtr.
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, burried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5mtr below normal ground level, connected to and including galvanized earth lead wire 4mm dia by means of GI bolts, nuts, check nuts and washers and connected other end to main board duly protected by GI pipe 15mm bore, medium grade, earth plate surrounded by packed layer of coal dust and common salt 15cm thick all around bottom and top watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plate No. 3 of SSR Part – I and connecting to earthing test point, main switch board and testing on completion including CI cover, frame and PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in earthing pit with CI cover and frame including necessary earth works etc, all as specified and directed by Engineer - in – Charge. Note:- 1. PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode of the earth pit and pipe for watering shall be provided in slanting manner.
Supply and fixing for galvanised iron strip 25 x 4 mm buried in ground with saddles amd fixing screws etc for roof conductors and down conductors including removing and replacement of deteriorated SS bolts, nuts and washers as required at site in the existing GI strip of any size from the starting point to upto the end connected points all as specified and directed. Note:- (i) PVC type DC insulators with screw, nuts, bolts etc to be used in surface/ wall/ floor for mounting of strip and distance between two insulator shall not be less than 1.0 metre. Rate qouted shall be deemed to be included the PVC DC insulators. (ii) The strip will be measured and paid separately beyond 7.50 metre for each bldg.
M&L street light brackets parabolic type made out of GI tubes medium grade 40mm bore (1.50m long) including bending to shape or welding, drilling, clamps, nuts and bolts etc to match with existing pattern including painting two coats aluminium paint over a coat of red oxide zinc chromate primer complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing of Single Loop Analogue Addressable Fire Alarm Control Panel, with a single loop driver card, loop current 500mA maximum per loop, dual flash based microprocessor, supports to connect 240 addressable devices one each loop via fully digital communication protocol, equipped with a white backlit display (240x64 pixel resolution) graphical LCD Display with atleast 6 lines of information, 200 fire zones (soft zones), fully programmable via alphanumeric keypad or configuration software, dedicated USB and RS-232 serial port for direct or PC connection. 5500 events storage, loop current 500 mA, panel shall be equipped with in-built multi-meter for live monitoring of loop current, earth voltage, loop voltage etc., installer's logo application, can be networked to compatible addressable panels and repeater panels by adding a network card, features battery charger status and temperature, supports programmable cause / effect on outputs, panel housing meets IP30 ingress protection classific all as specied and directed.
Supply & fixing of intelligent Sounder Interface Module allow to connect conventional Sounder and beacon to addressable loop, Witj in built short circuit isolator, allows for two stage alarm capability,addressed through auto and manual options. Approved by LPCB for EN 54-17 & EN 54-18 Standard complete all as specified and directed
Supply & fixing of Intelligent Analogue Multi-Criteria (combination of smoke and heat) Detector with special algorithms to utilise information from both smoke and heat sensing elements to ensure high level of immunity to false alarms without compromising genuine alarm sensing performance, programmable multiple smoke senstivity level and 9 modes of operation, bi-directional in-built short circuit isolator to protect against cable faults, dual bi-colour LED's with 360o view of status, auto- addressable/ electronically addressed, utilises fully digital communication addressable protocol with high noise rejection. Approved by LPCB for EN 54-5, EN 54-7, & EN 54-17 standard complete all as specified and directed.
Supply & fixing of Standard Detector Base for mounting the compatible addressable detectors complete all as specified and directed.
Supply & fixing of Intelligent Analogue Manual Call Point with resettable operating element, with in-built bi-directional short circuit isolator. Bi-Colour LED for local indication of device status, single action operation, reset to normal condition using special reset key, clearly visible alarm flag in the activated state. Approved by LCPB for EN 54-11 standard complete all as specified and directed.
Supply & fixing as in repairs of 2 core x 1.5 Sq.mm PVC insulated copper conductor armoured cable complete all as specified and directed.
Supply & fixing of Mounting Accessories like back box for detectors, devices & cable glands, etc complete all as specified and directed.
M & L Commissioning, installation and Testing of entire fire alarm and smoke & heat detector system as specified in Ser Ite No 01 to 11 all as specified and directed by Engineer-in-Charge. (Individual items shall be measured and paid under respective items of the schedule complete all as specified and directed.
M/s Super Trading Corporation (BID ID -3348142)
His Construction Company (BID ID -3348445)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .