Loading…
Loading…
Tender Value
₹78.0 L
EMD Value
₹1.6 L
Closing Date
6 Oct 2026, 1:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
TECHNICAL
14 conditions · 3 needing a document upload
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. Annual Contractual Turnover Data for the Previous 3/4 Years should be submitted as per Annexure-IX.(AnnexureVIB of Tender Documents)
Technical Eligibility Criteria: (a)The tenderer must have successfully completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender. (b) (i)In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed any of the following during last 07 seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(i): Separate completed works of minimum required values for each component shall also be considered for fulfillment of technical eligibility criteria. ( c) Similar nature of Work is defined as "Similar nature of Work is defined as "Supply, installation, testing and commissioning of any LT/HT Electrical Work. ." Note: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of opening of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
Similar nature of Work is defined as "Supply, installation, testing and commissioning of any LT/HT Electrical Work".
39 conditions · 9 needing a document upload
Check List: The tenderer(s) would fill up the check list, as per Annexure-XXIII to ensure that they are submitting the complete tender offer.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Electrical work for (A) Augmentation of Capacity of Running Room/Rest Room at LEDO,NTSK,DBRG &NLP including facilities improvement at NTSK,LEDO,NLP,DBRG & MZS at TSK Division. (B) Augmentation of Capacity of Running Room/ Rest Rooms at MXN &JTTN
LV-T-14-TSK-961~NFR
LV-T-14-TSK-961
Open
Works - General
12 Months
Tinsukia, Assam
₹0
₹1.6 L
15 Sept 2026
15 Sept 2026
22 Sept 2026
114 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 46,79,111 | ||
| — | 204.00 | — | — | ||
| Supply, fitting, fixing, testing & commissioning of wiring materials for concealed type wiring of light point from main/sub-main board to the points by 1.5 mm.sq.single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch 6 A, ceiling rose, GI box with suitable modules for fixing switches. | — | — | — | 1,33,416 | |
| — | 94.00 | — | — | ||
| Supply, fitting, fixing, testing & commissioning of wiring materials for concealed type wiring of Fan Point/Exhaust fan point from main/sub-main board to the points by 1.5 mm.sq.single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch 6 A, ceiling rose, Modular GI metal box with suitable modules for fixing switches and 1.0 sq mm multistrand FRLS copper Cable in green for earth contuinity wire. | — | — | — | 88,830 | |
| — | 84.00 | — | — | ||
| Supply, fitting, fixing of 5 Step Modular Fan Regulator 2 Module 100W | — | — | — | 33,768 | |
| — | 124.00 | — | — | ||
| Supply, fitting, fixing, testing & commisioning of wiring materials for concealed type wiring 5 A plug point from main/sub-main board to the points by 1.5 mm. sq. single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch & socket 5 A,GI metal box with Suitable modules for fixing switch/socket with 1.0 mm² unsheathed FRLS copper cable in green colour for earth continuity wire. | — | — | — | 53,072 | |
| — | 66.00 | — | — | ||
| Supply, fitting, fixing, testing & commisioning of wiring materials for concealed type wiring 15 A plug point from main/sub-main board to the points by 4 mm. sq. single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch & socket 15 A , GI metal box with Suitable modules for fixing switch/socket with 1.0 mm² unsheathed FRLS copper cable in green colour for earth continuity wire. | — | — | — | 81,180 | |
| — | 31.00 | — | — | ||
| Supply, fitting, fixing, testing & commissioning of wiring materials for concealed type wiring for AC point from main/sub-main board to the points by 6 mm sq single core multi-strand FRLS copper cable through heavy duty PVC conduit pipe including 16 Amps, AC MCB protected Power point having starter, socket with top & MCB and 1.0 mm.sq. unsheathed copper cable in green colour for earth continuity wire. | — | — | — | 56,110 | |
| — | 204.00 | — | — | ||
| Supply, fitting , fixing of Batten Intergated type LED fitting 20W, 4 Ft, ultra slim co- extruded polycarbonate channel with integrated electronic driver should be as per IEC: 62384/IS:16104( SMPS based constant current output, THD<20%), IP20 protection, color temperature=6500K, rated input voltage=230V AC, 50 Hz, power factor=0.9, view angle=120°, lumens output not less than 100 lm/Watt, operating voltage range: 140-270 V AC. LED Should be as per LM-80/IS:16105. Fixture Size:(LXWxH=1156x25x35 mm +/-1) | — | — | — | 51,204 | |
| — | 180.00 | — | — | ||
| Supply and fitting , fixing of 18 Watt LED ,Slim, compact, auminum die cast edge lit panel light , recess mounted square fixture with opal diffuser and separate electronic driver. Ceiling Cut Out (210x210 mm). | — | — | — | 2,37,960 | |
| — | 80.00 | — | — | ||
| Supply, installation, testing and commissioning of 7 Watt LED Reading Light/Track Light, swivel type, suitable for 230 V AC, 50 Hz supply, complete with high-quality LED module, integrated/separate LED driver as required, adjustable swivel arrangement for directional illumination, suitable mounting arrangement, connectors, terminals, fixing accessories and all other necessary accessories required for complete installation and proper functioning, as required at site. | — | — | — | 1,68,000 | |
| — | 16.00 | — | — | ||
| Supply, fitting, fixing of exhaust fan 300 mm sweep , 230V AC ,50Hz metallic louver type. | — | — | — | 23,568 | |
| — | 10.00 | — | — | ||
| Supply, fitting, fixing of Wiring materials for Concealed type Geyser point wiring from DB/ sub main board to the points by 4 mm. sq. single core multi-strand FRLS copper cable through heavy duty PVC pipe complete with modular type switch & socket 16 A , 3 Module Plate, GI metal flush box with Suitable modules for fixing switch/socket with 1.0 mm² unsheathed FRLS copper cable with 16 A DP MCB C series with DP enclosure in green colour for earth continuity wire. | — | — | — | 12,910 | |
| — | 10.00 | — | — | ||
| Supply , Fixing and testing of vertical type wall mounted storage Geyser of Capacity 25 Ltrs BEE 5 Star rated , 240V, 50Hz with Maximum power consumption of 2KW , dry powder fero glass line coating technology for inner tank with incoloy heating element with minimum 2 years warranty , ABS outer body , 2 units of PVC connector pipe with length of 450mm length for hot and cold water supply with complete accessories including external knob for temp control and Earth Leakage Circuit Breaker(ELCB). | — | — | — | 1,20,630 | |
| — | 810.00 | — | — | ||
| Supply, drawing and connection of single core 6 sq. mm PVC insulated & unsheathed multistrand FRLHS copper cable conforming to IS: 694 for voltage grade upto 1100 Volts , as per direction of supervisor incharge at site through walls/surface as required. | — | — | — | 68,850 | |
| — | 980.00 | — | — | ||
| Supply, drawing and connection of single core 4 sq. mm PVC insulated & unsheathed multistrand FRLHS copper cable conforming to IS: 694 for voltage grade upto 1100 Volts , as per direction of supervisor incharge at site through walls/surface as required. | — | — | — | 55,860 | |
| — | 1380.00 | — | — | ||
| Supply, drawing and connection of single core 2.5 sq. mm PVC insulated & unsheathed multistrand FRLHS copper cable conforming to IS: 694 for voltage grade upto 1100 Volts , as per direction of supervisor incharge at site through walls/surface as required. | — | — | — | 53,820 | |
| — | 14.00 | — | — | ||
| Supply, fitting, fixing, testing and commissioning of 6 way Double Door SPN MCB DB with IP-43 protection, Door earthing,Neutral Bar,earth bar and bus bar provided with the following MCBS:- (i)MCB SP 32 Amps C series 10KA BC= 2 Nos, (ii)MCB SP 16 Amps C series 10KA BC=2 Nos (iii)MCB SP 10 Amps C series 10KA BC=2 Nos | — | — | — | 52,500 | |
| — | 6.00 | — | — | ||
| Supply, fitting, fixing of wall mounted VTPN DB, Horizontal TP MCCB as incomer 4 way double door , IP: 43 Protection, Shrounded Neutral Bar and pan assembly with flexible connecting link., cement spill protector, door earthing with the following:(i) MCCB 100 Amps, TPN ,25KA BC= 1 No.(ii) MCB SP 63 Amps, C series, Icn =10KA BC= 4 Nos. (iii) MCB SP 32 Amps, C series, Icn =10KA BC= 3 Nos | — | — | — | 1,86,000 | |
| — | 14.00 | — | — | ||
| Erection of earth by 50 mm dia 3 Mtrs. long (3.6 mm thickness) GI pipe , 8 SWG GI wire,GI nuts, bolts including masonry materials for earthing pit, salt, charcoal etc. and construction of earth pit covered with RCC cover slab 12.7 mm thickness and watering pipe per Drawing No PCEE/ELG/DRG/2024/1 Dtd 30.09.2024 | — | — | — | 58,002 | |
| — | 3.00 | — | — | ||
| Supply, installation testing and commissioning of Acrylic LED signage f , Size: 10x4Ft( 40 SQ FT) with 4 mm ACP sheet background. The Frame of the Signage board to be fabricated using 1.5 x1 inch , MS square pipe 16 gauge. The Letters to be engraved with be 40mm Acrylic letters. The Power Supply unit will be separate Replaceable Electronic Driver 230VAC/12VDC , 5 Amps to be suitable fixed outside the LED Signage Board.The Signage Board Should have IP65 Degree of Protection . The caption of the LED Signage Board will be trilingual: English, Hindi , Assamese with and caption will be provided by Railways as per requirement . | — | — | — | 2,40,720 | |
| — | 372.00 | — | — | ||
| Supply, laying, connection, testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable Size 120 SQ MM 4 Core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988. For cable laying Excavation of earth depth 0.75 Mtrs. into breadth 0.58 Mtrs. below the ground level and a layer of course sand of 7.5 CM thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of course sand of 7.5 CM thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. Above the Layer of Course Sand 3 inch Size Brick is to be provided for protection of cable. Cable route markers to be provided at an interval not less than 50 Mtrs. All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024 | — | — | — | 3,47,820 | |
| — | 120.00 | — | — | ||
| Supply, laying, connection, testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable Size 70 SQ MM 4 Core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988. For cable laying Excavation of earth depth 0.75 Mtrs. into breadth 0.58 Mtrs. below the ground level and a layer of course sand of 7.5 CM thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of course sand of 7.5 CM thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. Above the Layer of Course Sand 3 inch Size Brick is to be provided for protection of cable. Cable route markers to be provided at an interval not less than 50 Mtrs. All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024 | — | — | — | 81,000 | |
| — | 160.00 | — | — | ||
| Supply, laying, connection, testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable Size 35 SQ MM 4 Core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988. For cable laying Excavation of earth depth 0.75 Mtrs. into breadth 0.58 Mtrs. below the ground level and a layer of course sand of 7.5 CM thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of course sand of 7.5 CM thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. Above the Layer of Course Sand 3 inch Size Brick is to be provided for protection of cable. Cable route markers to be provided at an interval not less than 50 Mtrs. All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024 | — | — | — | 72,320 | |
| — | 600.00 | — | — | ||
| Supply, laying, connection, testing and commissioning of LT XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured stranded aluminum conductor cable Size 16 SQ MM 4 Core having Galvanized steel Strip, Extruded PVC Type ST2 Sheathed, 650/1100V Grade As Per IS 7098(Part 1) 1988. For cable laying Excavation of earth depth 0.75 Mtrs. into breadth 0.58 Mtrs. below the ground level and a layer of course sand of 7.5 CM thickness shall be spread over the ground before laying the cable and the cable shall be covered with a layer of course sand of 7.5 CM thickness. The bottom of cable trench shall be leveled and got rid of any sharp material. Above the Layer of Course Sand 3 inch Size Brick is to be provided for protection of cable. Cable route markers to be provided at an interval not less than 50 Mtrs. All conditions to be fulfilled as per DRG No : PCEE/ELG/DRG/2024/2 Dtd 04.10.2024 | — | — | — | 2,25,000 | |
| — | 6.00 | — | — | ||
| Supply, fitting, fixing of 400 Amps outdoor type cable junction box, angle frame mounted, dust & vermin proof, complete with rain cap, aluminium basbar of suitable size for TPN, 400Amps, 415 V made out of 16 SWG CRCA sheet duly painted, Cable Junction Box Size: (lxbxh=450x 450x600 mm). The base of the fedder pillar junction box to be provided with CC foundation of propotion 1:1.5:3( cement, sang,Chips) after connection of Ug cables. | — | — | — | 55,032 | |
| — | 16.00 | — | — | ||
| a) Supply and erection of Single Arm type Hot Dip Galvanized in single deep to average 65 micron DFT 6 mtr. long octagonal pole with sectional dia 130x70 mm, overall sectional thickness 3 mm complete with base plate size 220x220x12 mm, 4 Nos. 600 mm long foundation bolt of 20 mm dia with all other accessories as per direction of Engineer in charge at site. b) Supply and erection of PCC/RCC/shallow foundation 1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) M15 Grade of size and depth as per recommendation and drawing of the manufacturer (approx. 1.6 mtr.x 0.6 mtr.x0.6 mtr.) with excavation of earth for foundation of all depth and all places, nature and condition of soil including de-watering, shoring, shuttering, batching, mixing, placing, leveling, carrying etc and re-filling the pit after completion of foundation work from excavated earth or borrowed pit by contractor's own arrangement for octagonal poles. | — | — | — | 3,27,376 | |
| — | 16.00 | — | — | ||
| — | — | — | 75,520 | ||
| — | 31.00 | — | — | ||
| — | — | — | 13,72,711 | ||
| — | 1.00 | — | — | ||
| Supply, fitting, fixing, testing and commissioning of Floor Mounted Outdoor Type LT panel board for The panel shall be metal-enclosed, free-standing compartmentalized, modular type suitable for outdoor installation. The panel shall be dust and vermin proof and the enclosure shall provide a degree of protection of not less than IP-65. The Panel shall be fabricated out of 16 SWG cold rolled steel plates & properly supported using angles & channels. The whole panel shall be mounted on a base frame made out of suitable structural, preferably ISMC Channels. Joints of any kind in sheet shall be seam welded, all welding slag grounded off and welding pitwiped smooth with plumber metal. All panels and covers shall be properly fitted and square with the frames and holes in the panel correctly positioned. The Panel shall be fully compartmentalised with front and back opening doors. When compartment door is opened, busbar and cable alley shall be shrouded by barrier plates. All panels shall be provided with suitable cable alley and vertical bus bar alley.Each cable chamber shall have cable entry from bottom and suitable removable gland plates shall be provided for this purpose. The cable chamber shall be provided with suitable supporting arrangement between the gland plate and terminals, in the middle. The cable chamber shall have a minimum width of 300 mm depending upon the outgoing cables. Each chamber shall be provided with a hinged type door opening away from the cable alley and shall be provided with black flowertype thumb screw which shall ensure tight closing. The edges of the door shall be provided with a neoprene rubber gasket to make the compartment dust proof. The panel shall consists of the following Switchgears: Incoming: ( BUS BAR=400 Amps TPN Aluminium) (i)MCCB 4 pole 400 Amps, 25 KA BC Ics=100%Icu , AdjustableThermal Magnetic OL & SC Protection=1 NO Outgoing: (ii) MCCB 4 Pole 125 Amps, 25KA BC Ics=100%Icu , AdjustableThermal Magnetic OL & SC Protection- 3 Nos (iii)Three Phase LED Ammeter with selectror switch inbuilt for main feeder= 1Nos (iv)Three Phase LED Voltmeter with selectror switch inbuilt for main Volt measurement range= 50-550 VAC= 1Nos (v) LED RYB indicator pilot lamp for indication of incoming = 3 Nos | — | — | — | 90,740 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderDocumentTSK961.pdf
ATTACHMENT
AnnexuresSectionVII.pdf
ATTACHMENT
GCCAPRIL2022WITHALLACS.pdf GCC 2022 with ACS
ATTACHMENT
GCCAPRIL2022WITHALLACS.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .