Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.6 LAccepted-AOC 10 2 NARAYAN BAG INDORE M P | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹46.2 L+₹29,467.25 (0.64%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹48.8 L+₹2.9 L (6.39%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹51.9 L+₹6.1 L (13.2%)Rejected-Finance | L4 | Rejected-Finance Being L4 |
Tender Value
₹49.9 L
EMD Value
₹99,900
Closing Date
21 Oct 2024, 6:00 pmClosed
GARRISON ENGINEER (MIS) MHOW
Garrison Engineer (Maint) Infantry School , Mhow -453441
SPECIAL REPAIR FOR IMPROVEMENT OF OLD UNSV LT PANELS AT VARIOUS AREAS OF AGE EM NO 01 AND PROVN AND INSTL OF SPLIT AC UNITS FOR COMPUTER IT EQPT ROOMS OF INF SCHOOL ICTW AND TRIVENI HALL WITH CONNECTED ITEMS AT INF SCHOOL UNDER GE MIS MHOW
2024_MES_676124_1
8718/GE (MIS)/Mhow
Open Tender
Civil Works - Others
Item Rate
150 days
GARRISON ENGINEER (MIS)
All as per Tender document
7 documents required · 7 mandatory
₹500
GE (MIS) Mhow
₹99,900
Yes
28 Nov 2024
23 Sept 2024
23 Oct 2024
23 Sept 2024
21 Oct 2024
7 Oct 2024
Amount
Taking out unserviceable LT connection cable of size up to 35 sqmm 3.5 core complete all as specified & directed.
Taking out old unserviceable LT cable of size 50 sqmm up to 95 sqmm 3.5 core complete all as specified & directed.
Supply, laying and testing cable XLPE insulated, galvanized steel strip or wire armoured electric power cables heavy duty 1100 volts grade, with stranded aluminium conductor with all fixing & connecting accessories such as aluminium cable lugs, cable gland, nut, bolts, washer etc in trenches/through pipes/ducts or on poles/walls jointing to O/H conductor, LT panels, main switch with suitable size aluminum lugs complete all as specified & directed for the following sizes:- Make:- Havells/ Finolex/ Policab/ Make as specified in Particular Spesifications Note : Excavation shall be measured and paid seperately.
(a) 95 Sqmm 3.5 core
(b) 50 Sqmm 3.5 core
(c) 35 Sqmm 3.5 core
(d) 16 Sqmm 4.0 core
Excavation in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete all as specified & directed.
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as specified & directed.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified & directed.
M&L for dry river sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying and stretching of cable and gently punning complete all as specified and directed. Note:-Punned thickness shall be measured and paid.
Sypply and laying fly ash bricks, laid in trenches as cable covers complete all as specified & directed.
Supply and laying Galvanised iron pipe in repairs "light grade" 80mm bore in trenches, under floors, roads, along poles for protection of cable with all necessary fittings, including sealing ends complete all as specified and directed.
Supply and laying Galvanised iron pipe in repairs "light grade" 40mm bore in trenches, under floors, roads, along poles for protection of cable with all necessary fittings, including sealing ends complete all as specified and directed.
Supply and errecting LT Panel outdoor type mounted and fixed with PCC foundation , made out of MS sheet factory assembled and factory fabricated out of 3.15 mm thick sheet steel with suitable size MS angle duly spray painted with two coat of gray synthetic enamel paint over one coat og red oxide zinc chrome primer after preparation of surface , with required civil work &wiring with copper cable of suitable size, connecting including indication lamp LED type foe each phase , incl inbuilt industrial type locking arrangments , front openable incl necessary arrangments for fixing with suitable, clamps,nuts, bolts wahers etc, & including Danger notice board , feeder marked,testing and commissioning , size 600 x600x 300 mm, complete including taking down old panel complete all as specified and directed by Engr-in-Charge.
Supply and fixing cable path indicator made of MS sheet of size 200 mm x 150 mm x 3 mm thick and spot welding with angle iron of size 40 x 40 x 5 mm thick, 750 mm long embedded in PCC (1:2:4) type B-1( using 12.5 mm graded granite stone aggregate) including providing one coat of synthetic enamlled black paint over one coat of red oxide primer and sign writing with white paint showing size of cable HT /LT complete all as specified & directed .
Supply, installation, testing and commissioning out door type LT panel board ,made out of 3.15mm thick CRCA sheet , factory made, cubical type,with slanting top at leaset 10 cm projection all around, fedder pillar type,fabricated with 50x50x6mm angle iron frame work with independent door for each feeder,busbar chamber cable tray on both side fully compartmentlized design, double door type & commen openable hinged door from rear side, floor mounting type, busbars made of aluminium duly insulated with heat retardent fire proof (HRFR) heat shrinkable sleeves of relevant colours.Bus bar shell be properly supported/mounted on epoxy insulators.All live parts and joints shall be insulated with (HRFR) shrouds, conforming to IS, including provn for connecting suitable earth strips,painting with one coat of anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032), Confirming to IP 54 protection and confirming relavent IS, comprising the adequate arrangement to supply & fix the following accessories,including connecting cable glands and cable lugs,fixing of earth lead to earth terminal of panel including necessary excavation & PCC foundation ncluding taking down old panel complete all as specified and directed by Engr-in-Charge. Note:- Cost of all accessories are deemed to be included in the rate quoted). (LT Panel No.1,2 &3)
Incoming (a) Aluminium bus bar - 400 Amps rating - 03 Nos. for phases and 150 Amp rating - 01 No. for neutral
(b) MCCB 4 pole 250 Amps, 415 volt, 36 KA - 01 No ( incoming) Make - Legrand / L&T / ABB / Schneider / Havells
(e) ON/OFF LED type indication lamp with toggle switch - Set of 03
Out going:- (a) MCCB 3 pole 160 Amp, 415 volt, 25 KA - 01 Nos Make - Legrand / L&T / ABB / Schneider / Havells
(b) MCCB 3 pole 100 Amp, 415 volt, 25 KA - 02 Nos Make - Legrand / L&T / ABB / Schneider / Havells
(c) MCCB 3 pole 63 Amp, 415 volt, 16 KA - 02 Nos Make - Legrand / L&T / ABB / Schneider / Havells
(d) MCB TPN 40 Amp, 415 volt, - 2 Nos Make - Legrand / L&T / ABB / Schneider / Havells
All as per item No 13.00 above but consisting the following items :- (LT Panel No 3,4, & 5)
Incoming (a) Aluminium bus bar - 250 Amps rating - 03 Nos. for phases and 100 Amp rating - 01 No. for neutral
(b) MCCB 4 pole 200 Amps, 415 volt, 36 KA Make - Legrand / L&T / ABB / Schneider / Havells
(e) ON/OFF LED type indication lamp with toggle switch - Set of 03
Out going:- (a) MCCB 4 pole 100 Amp, 415 volt, 16 KA - 02 Nos Make - Legrand / L&T / ABB / Schneider / Havells
(b)MCCB 4 pole 63 Amp, 415 volt, 16 KA - 02 Nos Make - Legrand / L&T / ABB / Schneider / Havells
(c) MCB TPN 40 Amp, 415 volt, - 2 Nos Make - Legrand / L&T / ABB / Schneider / Havells
All as per item No 13.00 above but consisting the following items :-( LT Panel No 06 & 07)
Incoming (a) Aluminium bus bar - 250 Amps rating - 03 Nos. for phases and 150 Amp rating - 01 No. for neutral
(b) MCCB 3 pole 160 Amps, 415 volt, 25 KA - 01 No ( incoming) Make - Legrand / L&T / ABB / Schneider / Havells
(e) ON/OFF LED type indication lamp with toggle switch - Set of 03
Out going:- (a) MCCB 3 pole 100 Amp, 415 volt, 16 KA - 02 Nos Make - Legrand / L&T / ABB / Schneider / Havells
(b) MCCB 3 pole 63 Amp, 415 volt, 16 KA - 01 Nos Make - Legrand / L&T / ABB / Schneider / Havells
(c) MCB TPN 40 Amp, 415 volt, - 01 Nos Make - Legrand / L&T / ABB / Schneider / Havells
M&L for Earthing complete (in replacement) with GI earth plate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using GI strip 32x6mm by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 50mm dia GI pipe connected to main switch board or main control board and GI pipe, light grade, 20mm bore, for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1:2:4 type B1 (including excavation and earth work, disposal of surplus soil to a distance not exceeding 50 metre) including excavation and earth works in any type of soil, including test point, testing & commissioning, complete all as specified and directed.Note:- (i) The unit rate shall include for protection pipe, GI water pipe, wire mesh, funnel, excavation, RCC pit cover, test point, 32mm x 6mm GI strip from top of earth plate upto 5 metre above ground level and if GI protection pipe is less than 5 metre, no price adjustment shall be made. (ii) RCC pit cover shall be precast of RCC 1:2:4, type B-1, 80mm thick reinforced with XPM weighing not less than 4 Kg/sqm in lieu of cast iron cover.
Supply and fix hi wall split units indor, outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 3 Star rating and EER 3.2 of capacity 2.0 TR , 3 star rated invertor split AC along with steel wall bracket and necessry copper tube and electric wiring with making good surface for disturb area as same and testing complete Make: Hitachi / Voltas / Carrier
Supply and fix hi wall split units indor, outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 3 Star rating and EER 3.2 of capacity 1.5 TR , 3 star rated invertor split AC along with steel wall bracket and necessry copper tube and electric wiring with making good surface for disturb area as same and testing complete. Make: Hitachi / Voltas / Carrier
S&F Copper tubing of following size complete:-
(a) 3/8” size
(b) 5/8 ” size
(c) 1” size
(d) 1/4 ” size
(e) 1/2” size
S&F Single pole and neutral Sheet Metal enclosure with a two pin and earth plug and socket complete with one single pole MCB,20 Amps incl cutting of wall and fixing of AC box in concealed system and making good of disturbed surfaces complete all specified and as directed. Make: ABB/L&T/Schneider/Havells/ Make as specified in Particular specifications
M&L for Sub main wiring with two runs of single core FR LS PVC insulated unsheathed cable 1100 volts grade, 4 Sqmm size with multistranded copper conductor, drawn in and including non metallic rigid PVC conduit of not less than 25 mm dia concealed in wall by cutting chases of wall and making good the disturbed surface, including FR LS PVC insulated unsheathed 4.0 Sqmm cable with multistranded copper conductor green PVC insulated as continuous earth conductor cable connected to earth dolly from main distribution board complete all as specified and directed by Engr-in-Charge. Make of PVC conduit/Casing Caping:- Plaza/Finolex/Polycab/ Kalinga/Jindal /Asian Make of wire - HPL/L&T/Polycab/Havells/ Make as specified in Particular specifications
S&F flush mounting factory made Vertical TPN DB, IP-43 Protection -IK 08, with metal double door with 200 Amps rated copper busbar with 2 neutral bar, earth bar and cables ties for cable management fully insulated bus bar with set of wires and door earthing with provision of sapce for TP/FP 100-125 amps G Frame MCCB as incomer and SP/TP MCBs as out going 8 way complete all as specified and directed by Engr-in-Charge. Make- HPL/L&T/Polycab/Havells/ Make as specified in Particular specifications
S&F MCB Four pole rated capacity 100 Amps, 240 volts breaking capacity 10 KA complete all as specified and as directed. Make: ABB/L&T/Schneider/Havells/ Make as specified in Particular specifications
S&F MCB SP 6 to 32 amps 16 KA ,C-series including connection with suitable size aluminium / copper lugs complete all as specified and directed by Engr-in-Charge. Make: ABB/L&T/Schneider/Havells/ Make as specified in Particular specifications
S&F MCB SPN 40 amps 10 KA ,C-series including connection with suitable size aluminium / copper lugs complete all as specified and directed by Engr-in-Charge. Make: ABB/L&T/Schneider/Havells/ Make as specified in Particular specifications
M&L for Earthing complete with galvanized steel earth plate electrode 60cm x 60cmx 6.3 mm thick buried directly in ground ( earth pit not less than 2.25 meter deep below ground level) with the top edge of the earth plate not less than 1.5 meter below normal ground level connected to galvanized earth lead wire 4mm dia by means of bolts, nuts, check nuts and washer of galvanized iron or of steel all as shown in electrical plate No.3 of MES SSR parts-I and including excavation & earth work in any type of soil , disposal of soil , providing alternate layers of charcoal and common salt, construction of PCC earth chamber in mix 1:3:6 type c-1 with 40 mm thick RCC 1:2:4 type B-J cover reinforced with 8mm dia MS bars both ways with lift hook made out of 8 mm dia TMT bar, watering arrangement with funnel and wiremesh and watering pipe of 20mm dia GI light grade and 15mm dia light grade pipe for earth lead protection and testing on completion, complete all as specified and directed.
Mighty Steel Sales Crop (BID ID -3145776)
M/S UnitedConstruction (BID ID -3145780)
MODI CORPORATION (BID ID -3142490)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .