Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹61.1 LAccepted-Finance | L1 | Accepted-Finance Quoting Lowest Rate | |
| 2 | L2₹66.8 L+₹5.7 L (9.41%)Rejected-Finance | L2 | Rejected-Finance Quoting Higher Rate | |
| 3 | L3₹69.6 L+₹8.5 L (14.0%)Rejected-Finance | L3 | Rejected-Finance Quoting Higher Rate |
Tender Value
Refer Docs
EMD Value
₹1.4 L
Closing Date
19 Jul 2023, 3:00 pmClosed
Superintending Engineer
Office of the Superintending Engineer, Western Electrical Circle , PWD, Purta Bhavan, 1st floor, Burdwan-713103
Electrical Installation work, arrangement of Air-conditioning, modification/addition/alteration of the existing Fire Detection system and SITC of 62.5 KVA DG Set in respect of preparation of proposed Blood bank with Component Separation unit at Sera
2023_WBPWD_544675_1
WBPWD/SEWEC /HED /NIQ-36 /2023-24
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Serampore
Please refer Tender documents.
5 documents required · 5 mandatory
₹1.4 L
Office of the Superintending Engineer, Western Ele
16 Aug 2023
28 Jun 2023
21 Jul 2023
28 Jun 2023
19 Jul 2023
1 Jul 2023
28 Jun 2023 - 30 Jun 2023
30 Jun 2023
Amount
Sub-Head 1-Distribution Wiring
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed]
8 Mtr [4(c)/ E-25 ]
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish. 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC
On Board [ 3 (i) / E- 20 ]
Sub-Head 2- PVC Rigid Conduit,Polythene pipe & Wire
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] of following sizes on wall, ceiling with saddles and other accessories as required and mending good damages to building works
20 mm size [ 7(a)/ E- 16 ]
25 mm size [ 7(b)/ E- 16 ]
Cutting Channel of required size on masonry wall by Electric operated cutting machine incl. supplying & fixing of heavy gauge Polythene pipe of following diameter as per GS.
19 mm dia 3 mm thick [ 6 (a)/ E- 3 ]
25mm dia 3 mm thick [ 7 (a)/ E- 3 ]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire(Brand approved by E.I.C) of the following sizes in the 19mm/25mm prelaid polythene pipe/PVC rigid conduit as per GS.
3 x (1.5 sqmm) [1(b) / E- 9 ] For Plug point having 02 nos 6A Plug Sockets.
2x(2.5 sqmm) + 1x(1.5 sqmm) [ 1(s) / E-9 ] For Plug point having 04 nos 6A Plug sockets ang plug point having 01 no 6 A Plug sockets and 01 no,16 A Plug sockets.
2x(4 sqmm) + 1x (2.5 sqmm) [ 1(v) / E- 9 ] For Split RAC machines.
2x (6 sqmm) + 1x (4 sqmm) [1(y) / E- 9 ] For SPNDBs
4x(4 sqmm) + 2x (2.5 sqmm) [ 1(x) / E- 9 ] For industrial Sockets.
S & F solderless Copper socket by crimping of Copper wires.
2.5 sq mm [9(i) / F-5]
4 sq mm [9(ii) / F-5]
6 sq mm [9(iii) / F-5]
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes(in mm ) flushed in wall & 3 mm thick bakellite cover as per GS
175 x 100 x 65 [11(c)/E-4 ,13(c)/E-5]
Sub-Head 3- Cables & laying
Supply of 4/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Gloster/RR/Polycab]
4 Core 10 Sq. mm For 5.5 Ton AC machines
4 Core 16 Sq. mm For 11 Ton AC machines
4 Core 25 Sq. mm For HTPNDBs
4 Core 70 Sqmm For VTPNDBs
Laying of cable after cutting floor/pavement/wall as per GS for the following Sizes.
2.5 to 35 Sq. mm [ 5(i)/ F- 3 ]
Laying of 3/3½/4 core cable of following sizes on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting as GS.
upto 3/4 core 25 Sq. mm [ 2(b)/ F- 2 ]
Laying of cable above 3½ core 50 sqmm and upto 3½ core 90 sqmm [ 2(b)/ F- 2 ]
Supplying and fixing compression type gland and finishing the end for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS.
4Core 10 Sq. mm [7(c)/F4 & 8(b- xi) /F5]
4Core 16 Sq. mm [7(c)/F4 & 8(b- xii) /F5]
4Core 25 Sq. mm [7(c)/F4 & 8(b- xiii) /F5]
4 Core 70 Sq. mm [7(c)/F4 & 8(b) /F5]
Sub-Head 4-VTPN, SPNDB,PDB, etc.
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall as per GS as per direction of EIC.
8 Way ( Up to 160 A ) Make - Legrand/Siemens/L&T/Siemens/Crabtree [15 / D- 11 ]
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS.
6 Way Make - Legrand/Schneider/Crabtree LT/Siemens [ 14 / D- 10 ]
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS.
2+12 Way [Siemens/ Schneider / Legrand/Crabtree [ 13 / D- 9 & D-10 ]
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment
Supplying and fixing of digital time switch (Mk- L&T, AUTS02DIG00) in existing 2 way SS encloser as per direction of EIC. [NS]
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA in existing Vertical DBs including necessary connection as per GS [ Make - Legrand / Schneider/L&T/Siemens as per direction of EIC.].
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as per GS [Make-Legrand/ Schneider/Siemens/ Crabtree/ L&T) as per direction of EIC. ]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [Make-Legrand/ Schneider/Siemens/Crabtree/L&T) as per direction of EIC. ]
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 as per GS
6 Way (Horizontal) [16/D-12]
4 Way / 8 Way (Vertical) [16/D-12]
Sub-Head 5- Plugs & Sockets etc.
Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works
6 module 1(b)/E-17]
Supplying & Fixing GI Modular Switch Board of the following sizes complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works
2 module 2(a)/E-17]
Supplying & Fixing modular type socket /socket (Legrand-Model Arteor/Myrius/Crabtree. in exsisting Modular board incl. connections.
6 A 5-pin modular type three pin socket [4(a)/E-17]
6 A modular type switch [3(a)/E-17]
16 A 5-pin modular type three pin socket [4(b)/E-17]
16 A modular type switch [3(b)/E-17]
Supply & Fixing 240 V, 25 A, Modular type AC starter (Brand approved by EIC) with 25A Modular switch type DP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [17 / E-19]
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. [ 5(a) / E-17]
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.[ 5(b) / E-17]
S/F Stainless Steel water proof looping cable box of size 200x150x100mm having hinged top Cover with rubber gasket lining, railway type mechanical locking anangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 16 A SPMCB unit, one NL on porcelain insulator etc. and housing the same on pole above 5ft from ground level by necessary pole clamp . (For Ductable AC outdoor unit and compound light).
Supplying & Fixing Industrial Plug & Socket board with 415 V, 30A, TPN & Earth Metal Industrial Plug socket & 30A Industrial top incl. S&F 32 A TPN/FP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and cecessary conection. (18/D-12]
Supplying & Fixing Industrial Plug & Socket board with 240 V, 32A, SPN & Earth Metal Industrial Plug socket (L&T cat no.-MPS332S or equivalent) & 32A Industrial top(L&T cat no.-MPS332p or equivalent) in SS enclosure fixed on wall and nececessary interconection incl. S&F 175x100x65mm Sheet metal Inspection Box[11(c )/E-4] and 3mm thick Bakelite top cover(13(c )/E-5] .
Sub-Head 6- Timer DBs & Industrial Sockets etc.
S&F of 250V timer DB (equivalent to 12 way SPNDB in size) with double door sheet steel enclosure, neutral bar, din rail, with lP43 protection comprises with 25/32 A DPMCB(C-curve 10ka) and 1 no 24 hr analog time switch and 1 no 25/32 A power contactor complete with internal wiring with suitable size of copper wire including 1 no toggle switch and LED indicator and earthing attachment as per direction of EIC. (For 2 Tr Split AC at Control Room ) [NS]
S & F 3 phase dual timer box Made of 14 SWG MS sheet (size approx– 400 X 350 X 175mm) with powder coated synthetic paint incl. hinged type MS door , inter locking system or equivalent to 4 way TPNDB in size consisting the following materials : 1) S & F 24 Hr. timer (L & T , J648B1/Legrand) – 1 no. 2) S & F 440 Volt 40A 3P contactor (L & T, ML – 3 , SS90721) – 2 no. 3) 6 amp auto mannual toggle switch – 1 no. (L &T) 4) Indicating lamp B & G (L&T) – 2 nos. 5) 440V, 40A, 10KA, Cseries FP MCB (legrand)on din rail for incoming-1no 6) 100A capacity 4W Brass stud type connector on FRP chair for I/C & O/G- 2nos All control circuit wiring would be made by 1x1.5 sqmm stranded Cu wire(FRLS) and the I/G & O/G circuit with 1x6sqmm copper wire maintaining colour code incl taping, socketing to complete the work. The box should be fixed on wall with suitable size of flush nut and necy. Connection. (For 5.5 Ton/ 11 Ton Ductable Split AC) [NS]
Sub-Head 7- Supply and Fixing of Light fittings etc.
Supply and delivery of single/twin Industrial LED Batten luminaries incl. Supply of 1 no./2nos. 18W LED Tube
Single fittings [Philips make Cat No. TMC-501 P1xT-LED 22W P3241/ Bajaj / Wipro/CG incl. 1 no. 18W Master LED Tube With 3 years warrenty.
S & F of 36W recessed mounted LED light fittings(warm-white or cool day light as per application) Incl. necessary connections as per direction of EIC. (Make-CG, cat no.- LCTLRNE-36-FO- WW(2x2)/LCTLRNE-36-FO-CDL(2x2),Phillips / Bajaj / Wipro. With 3 years warrenty.
S & F of 18W recessed mounted LED light fittings(warm-white or cool day light as per application) Incl. necessary connections as per direction of EIC. (Make-CG, cat no.- LSCRM-18W-WW/LSCRM-18W-CDL /Phillips / Bajaj / Wipro. With 3 years warrenty.
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. [16/C-2]
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVCround block / round bakelite on wall/ceiling as per GS [ 22/D-13 ]
Supply and fixing 14 W LED bulb(Bajaj/CG/Philips/wipro) on existing batten holder
Fixing only single/twin fluorescent/LED light fitting in the ceiling fixed with “L” type MS clamp for RC ceiling / MS pipe as per GS direction of EIC [ 17/C-2 ]
Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling as per GS. [ 14d/C-2 ]
Sub-Head 8- Supply and Fixing of Fans etc.
Supply of ceiling fans with burst-proof P2/S3 Capacitor complete with all accessories without regulator. ( Make - Orient Electric Laurel/ Crompton high speed Diego/ Bajaj Fdge HS Deco) With 3 years warrenty.
a. 1200 mm Sweep
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS [ 21 (a) / C-3 ]
Supplying & Fixing MS fan clamp of two piece type for RCC as per approved specification as per GS. [ 29/D-14 ]
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) ([Legrand-Model Arteror/Myrius or equivalent model of Crabtree/Equivalent make as per direction of E.I.) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. [10/E18]
Supply & fixing 450mm sweep wall bracket fan(high speed) with metal body & blades(Orient - Wall-II Tornado or equivalent cat of CG/EPC/Cinni) with necessary wooden board on wall with nuts, bolts, washer etc.
Supply of heavy duty Exhaust fan(Make-EPC] of followinng sizes after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust incl. s&f louver shutter as per G.S. )
9"( 230mm ) Speed 1370 RPM
12"( 300mm ) Speed 920 RPM
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:
Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) [32(a)/D-14]
Sub-Head 9- Compound light ,
Supply of 240V, 120 W LED 120-130 lum/watt Street light luminarie complete with all accessories and equipped with IP66 Protection (Crompton Geaves-Cat no.LSTP-120-CDL-Bajaj//wipro) on existing MS Pipe/Mini Pole as per direction of E.I.C With 5 years warrenty.
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required as following size as per GS.
50 mm dia [11(d)/F-6]
S & D 1 phase 230V,MF-1 Starter with over load relay for compound light(Make: L & T , MF-1 cat No :SS97227OOCO or equivalent as approved by EIC) [NS]
Fixing only starters (for motor control) on flat iron frame for Direct on Line starter for motor (upto 5 HP) [7(a)/C-1]
S & F mini pole on roof top by 80 mm dia., 2 Mtr. Long GI(M) pipe medium quality (Bansal/Jindal make) incl. Providing CC (6:3:1) muffing 600x600x760 mm in size or equivalent size of cylindrical muffing above ground level around the pole base complete with 3 mm thick neatly finished cement plaster all round after dismantling the unserviceable muffing if necessary. With 250x250x100mm 16 SWG GI Loop Box incl. S&F 50 mm. dia 1.5 mtr. long detachable type G.I. Single arm bracket, suitable for pole head. The arm bracket shall be properly welded with 15 mm. thick stifner plate of pole sleeve for strengthening incl. properly fixing arrangement with the pole by bolts, nuts and washer as per direction of EIC. [Schedole+NS]
Painting of any steel/ iron surface with 2 nos. of aluminium coats of paint over 1 coat of RO priming with ready mixed paint/primer of approved make and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint for single/double/triple arm bracket. [ 7B (a & b) / H-2 ]
Supply of LED Tube illuminated sign board fabricated by 6'(L)x4'(H)x10"(W) ACP box supported with 40 x 40 x 6 mm M.S. Angle structure all around with 40mm x40mmx 1.62 mm Al. edge angle for front portion only.The back side of the cover will be fabricated with hinges and arrangement in such a way so that it can be opened for maintenance purpose, including mechanical locking arrangement .The 3 mm ACP facial (Blue colour) should be provided with laser cutting of 5 mm laser cut Acrylic letters out of which 4 mm rising and back portion of the ACP board should be pasted with 2mm thick Clear Acrylic Sheet of same size as ACP facial as per the direction of EIC.The sign board should be illuminated by 18W LED Tube lamps (8 nos.) (Type- MAS LED Tube lamp 18 W 2100 lm) with Tube fittings (Phillips make) to be fixed by hooking arrangement with iron stucture fabricated for fixing purpose. Distribution wiring for power supply to LED fittings to be done by PVC rigid conduit, necessary clamps, cable tie etc. Back side of the of the board should be covered with 20 SWG G.I. sheet to protect rain water. The matter to be displayed will be finalised by authority and to be given later.This fabricated display structure is to be fixed on the top of prefabricated iron structure as per direction of EIC.
Fabrication charge of the iron structure incl. hiring of welding machine incl. making connection as required for making M.S. structural work in column beam etc. with simple rolled structural members(e.g. joist, angle chanel,section).including Supplying of M.S. angle (40 x 40 x 6 mm) 3.8 kg/mtr, MS base plate (8mmx305mmx508mm), MS Channel (150x75x6mm) 16.79 kg/ mtr and.M.S. flat (50 x 6 mm) (10 mtr.) 1.2 kg/mtr.Cutting and drilling holes on MS plate with grinding the plate. This plate is to be welded with the precutting roof with 4"x0.5" size fastner for installation of LED Glow Sign Board as per direction of EIC.
SUB-HEAD 10 --MISCELLANEOUS
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board as per GS [ 20( a )/D-13 ]
Dismantling the existing damaged defective unuseable electrical Installation materials.
Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991)– 4 bars, 415 V, 200 A, [Dimension of Al. bars: 85mm long, 4x50x6 mm) (Dimension of Sheet Metal Box: 500x150 mm)] [19(a) / D- 12 ]
SUB-HEAD 11 --LIGHTING CONDUCTOR
S & F Lightning Conductor Air Terminal made of 20 mm dia 1000 mm long GI pipe (ISI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) wire at top duly soldered with 7/16 stranded GI (Hot Dip) wire and 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. complete duly grouted on the parapet etc. in CC mortar ( 4:2:1). (P-J-2/Item-14)
Supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the Parapet/Roof/ Wall with GI Saddles 1100 mm apart incl. mending good the damages to building works. (P-J1/Item-9)
Supply & fixing of GI (Hot Dip) strips 20 mm x 3 mm thick for vertical run on wall with GI saddles spaced not exceeding 1000 mm apart incl. mending good damages to building work,. (P-J1/Item-11a)
Cutting cornices/ steps etc. including cutting recess in buildings etc. & supply & fixing 15 mm bore (ISI-Medium) GI pipe protection as below and mending good damages to the building works:
i) Length upto 0.5 Mtr (P-J1/Item-4a)
ii) Length above 0.5 Mtr (P-J1/Item-4b)
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run. (P-J1/Item-7)
Supply & Fixing of Testing Joints by 20 mm x 3 mm thick GI (Hot Dip) strip 125 mm long grouted on wall having clearance of 6 mm from wall for making connection with thimbles at the end of 7/10 SWG GI (Hot Dip) stranded Wire and 4 SWG GI (Hot Dip) wire of vertical conductor and conductor from earth electrode complete with S & F thimbles, GI bolts, nuts, check-nuts, spring washers etc. as required. (P-J2/Item-13)
Earthing with 65 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 No. 50 mm x 6 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts.(P-G1/Item-2d)
Excavation of soil for installation of Earth Electrode and filling & ramming as to GS (For soft soil). (P-G1/Item-1a)
Connecting the equipments body to earth busbar incl. S & F 50 mm x 6 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc.(P-G3/Item-5e)
SUB-HEAD 12 -- EARTHING
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level [ By TATA-Medium GI pipe] [2(a)/G-1].
Excavation of soil for installation of Earth Electrode and filling & ramming. (For Soft Soil) [1(a)/G-1]
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement mortar (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [3(a)/G-2]
Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS
No.-4 SWG [5(a)(i)/G-2]
No.-8 SWG [5(a)(ii)/G-2]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required [4(a)/G-2]
Supply,Installation, testing & Commissioning Charges for Microprocessor based air cooled 11.0TR ceiling suspended ductable type Split Air Conditioner having nominal cooling capacity of 132000 BTU/hr. at ISI condition suitable for operation on 415V, + 5% - 50 Hz. - 3Ph AC supply. Each unit consist of Twin Rotary compressor with R-410A/R407C Refrigerant .(one running Condition & One Stand By Condition.) (Make: Hitachi/Daikin/O-General/Carrier/Voltas as approved by E.I.C)
Supply,Installation, testing & Commissioning Charges for Microprocessor based air cooled 5.5TR ceiling suspended ductable type Split Air Conditioner having nominal cooling capacity of 66000 BTU/hr. at ISI condition suitable for operation on 415V, + 5% - 50 Hz. - 3Ph AC supply. Each unit consist of Twin Rotary compressor with R-410A/R407C Refrigerant .(one running Condition & One Stand By Condition.) (Make: Hitachi/Daikin/O-General/Carrier/Voltas as approved by E.I.C)
Supply,Installation & Commissioning Charges of 3.0TR capacity concealed type Split Air Conditioner of rated cooling capacity of 36000 BTU/hr. with 2Nos.Rotary compressor, 2nos. IDU of rated power supply-230V-1ph-50Hz. , 1no. ODU of rated power supply-230V-1ph-50Hz, R410A Refigerant. Air-flow/per IDU:- 600CFM. ( Make: O-General/Hitachi /Carrier)
Supply,Installation & Commissioning Charges of 2.0TR capacity concealed type Split Air Conditioner of rated cooling capacity of 24000 BTU/hr. with 1Nos.Rotary compressor, 1nos. IDU of rated power supply-230V-1ph-50Hz. , 1no. ODU of rated power supply-230V-1ph-50Hz, R410A Refigerant. Air-flow/per IDU:- 800CFM. ( Make:O-General/ Hitachi/ Carrier)
Supply & Laying Extra Add-on items- 7/8"(for liquid line) & 1/2"(for suction line) copper refrigerant pipe with 9mm thick nitrile rubber insulation, 7 core x 2.5 sq.mm. copper cable incl. fixing arrangement and wrapping insulation of aerotape complete in all respect for For 11.0 & 5.5 Tr Ductable split AC Machine. and Supply & laying PVC Drain Pipe 40mm dia by shaddling on wall incl. PVC "T", elbow, bend etc as per direction of E.I.C
Supply & Laying Extra Add-on items- 5/8"(for liquid line) & 1/4"(for suction line) copper refrigerant pipe with 9mm thick nitrile rubber insulation, 4 core x 2.5 sq.mm. copper cable incl. fixing arrangement and wrapping insulation of aerotape complete in all respect for 3.0 & 2 Tr Concealed split AC Machine. and Supply & laying PVC Drain Pipe 25mm dia by shaddling on wall incl. PVC "T", elbow, bend etc as per direction of E.I.C
Supplying, fabrication & fixing of M.S. structure with U- channel of 6mm thick of size (75mm x 40mm x 40mm) for making Bae frame/platform for the installation of outdoor unit of 11.0 & 5.5TR Ductable type AC incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc fabricated with horizontal angle of 25mm x 25mm x6mm including supporting angle 50mm x 50mm x 6mm in outer edge for transmitting the load centrally through 2 nos (50mm x 50mm x6mm) Angle inserted into the existing wall incl. S&F of safety cage made of angle (25X25X5mm) and flat (25X5mm) iron with necessary painting. as per direction of E.I.C.
Supplying, fabrication & fixing 2 Nos. M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) of 1m length for making Base frame for installation of AC ODU incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with 2 Nos. horizontal angle of 50 mm x 50 mm x 6 mm of 1.5m length as per direction of E.I.C incl. Platforn.
Supply, fabrication and installation of sheet metal duct in accordance with the approve ducting, laying, drawing, including accessories like anchor fastners, MS angle / rod for support, dampers, turning vanes etc. (Make- TATA/SAIL/JINDAL)
24 gauge galvanized sheet
22 gauge galvanized sheet
Supply & Fixing Aluminium powder coated Continuous Grill. (Mk. System Air/ Premire /Air Master as approved by E.I.C)
Supply & Fixing of 22 G GI aerofoil blades type Non Return Dampers complete with linkages, levers, fittings, supports, all accessories any other item required to make the system complete as per direction of EIC.
Acoustic lining of duct work with 9mm thick Open shel Nitrile Rubber. (K-Flex / Amracell / Supreme)
Supply & fixing of 10 mm thick Opec Cell Nitrile rubber thermal insulation under duct complete with all accessory as required.(Make- Supreme,K-flex.) as per direction EIC..
Supply & fixing of fire retardant nonporous double layer flexible connection (CANVAS) between each unit and duct as per direction of E.I.C.
Supplying, fitting & fixing in position suspended boxing for return air arrangement & indoor units of concealed split airconditioner with frame work of aluminium hollow section of size 50mm x25mm (3.0mm thickness) combined with aluminium corners of size 38mm x 25mm, suspended by aluminium hollow tube section of size 38mm x 25mm ,25mm x 25mm powder coated wall angle with aluminium composit panel of thickness 3.0mm comprising of protective film, polyester coating, primer, aluminium coil, adhesive film, polyethylene core again with one layer adhesive film, aluminium bottom coating and finally service coating as per manufacturer's specification finished with aluminium screw and silicon sealent including suitable arrangement for grill fixing complete in all respect as per direction of EIC.
Arrangement of Trap Door with Aluminium Channel & Fire Retardant ACP Board of 3mm thick for maintenance of IDU units as per direction of EIC.
Charges for scaffolding arrangement incl. lifting, shifting for outdoor & indoor units of 11 Tr./5.5 Tr. Ductable Split Air Conditioner machine
Supply & charging Refrigerant-R410A
SITC of aluminium Power coated supply air Diffuser with VCD(Make: Air Kolkata/Primier)
SITC of aluminium Power coated return air Diffuser without VCD(Make: Air Kolkata/Primier)
Supply, Installation,Testing & Commisioning of Micropresssor controlled IP Addressable multisensor detector IP 54 ( VDS / UL /ERTL/ LPCB / FM approved ) with inbuilt optical smoke sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. The detector should have 360 degree optical view with single / multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors. (Approved Make : Cerberus Pro / Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST )
Supply, Installation,Testing & Commisioning of IP Addressable Manual Call Point ( VDS / UL /ERTL/ LPCB / FM approved ) with in built short circuit fault isolator as per NFPA style 7 wiring complete as required. (Approved Make: Cerberus Pro/ Johnson Controls/ Edward /Secutron/ Securiton/ Apollo / Morley / Eaton/ GST )
Supply, Installation, Testing & Commissioning of IP Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd) complete with inbuilt short circuit fault isolator. Degree of protection IP65 ( VDS / UL /ERTL/ LPCB / FM approved) approved. (Approved Make: Cerberus Pro/ Johnson Controls / Edward /Secutron/ Securiton/ Apollo / Morley / Eaton/ GST )
Supplying, installation, testing and commissioning of LED type Response Indicator ( VDS / UL /ERTL/ LPCB / FM approved) having 2 Nos. red coloured LED lamps including connections etc. (Approved Make : Cerberus Pro/ Honeywell/ Johnson Controls / Edward /Secutron/ Securiton/ Apollo / Morley / Eaton/ GST/ System Sensor/Agni Suraksha / Ravel/Notofire)
Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex/RR Kable/Polycab ) through 19 mm dia PVC 'FR' type Rigid Conduit pipe with necessary arrangement as per G.S. (Make : Precision/ AKG/ Universal/ Polycab) on the surface of the wall.
Cleaning and checking of existing Addressable Smoke cum Heat type multi-Sensor Detector.
Supply and fixing of glass on existing manual call point as replacement of old damaged one.
Charges for checking, testing & re-commissioning of existing Smoke cum Heat type Multi-Sensor Detectors, manual call point, monitor devices etc installed at Ground Floor of OPD building including different controll devices of existing main fire control panel after proper checking and functioning of existing loops.
Supply, installation,testing and commissioning of 62.5-KVA, 415V, 50Hz, 3Ø silent new DG Set, comprising of Engine, alternator, separate AMF panel, Base frame, Fuel tank, Battery, CPCB-II approved Engin & Acoustic Enclosure having following specifications :-
ENGINE
Make : Greaves/Kirloskar/Volvo/ Cummins /Mahindra
Engine Type : 4 Stroke Diesel Engine
Rated Output : 79 BHP or Higher
Duty : PRIME
Cooling : Water cooled with radiator
Cylinder : 3/4
Aspiration : Turbo Charged
Type of Governer : Electronic
Fuel Tank Capacity : Minimum capacity 125 Ltrs.
Fuel Consumption at 75% rated Load with Radiator or Fan : 11.65 Ltr./ Hr. or Less
Fuel Consumption at 100% rated Load with Radiator or Fan : 15.13 Ltr./ Hr. or Less
Overload Capacity : 10% overload for one hour for every 12 hours continious running at full load or better
Engine instrument Panel : Consisting of starting switch with Key, Lube Oil Indicator, water temperature Indicator, RPM indicator and hour meter.
Safety Controls : Emergency Stop, Low Lube Oil Pressure warning/ Shutdown, High Engine Water Temp. warning/ Shutdown, Sensor failure Indicator, Engine overspeed indicator, Battery charging and low battery indicator
Exhaust Silencer : Residential Type
Starting system : 12V. starting system complete with starter motor, charging alternator with rectifier and Cutout as per manufacturer standard.
Battery : Lead Acid, Low Maintenance or SMF and conforming to relevant IS Specification with Low/High Battery Voltage and Weak Battery warning
ALTERNATOR
Make: Crompton Greaves /Kirloskar/ Ashok Ley Power approved by EIC
Rating : 415 V., 3Ph. 50 Hz., 62.5 kVA, 1500 rpm
Type : Brushless, self excited and self regulated
Insulation : Class H
Protection : screen-protected drip proof with Min.IP-23 degree of protection
Voltage Regulation (max) : ±1%
Winding connection : Star with Neutral
Total Distortion factor : Less than 3%
Total Harmonic distortion in output waveform : < 5%
AMF PANEL
Cubical type floor mounted AMF panel made from 16 SWG Sheet Steel, duly pretreated, powder coated painted and aesthetically finished, suitable for controlling of 62.5 KVA DG set having following specification/features.
i) 100A 36 KA MCCB with O/L, S/C, E/F protection and microprocessor based protection release , U/V release etc. - 2Sets
ii) In Built By-Pass switch for rated capacity
iii) On -delay timer for load change over
iv) On-delay timer for engine shut off
v) Engine On-Off switch (Push button type)
vii) Minimum five number indicating lamps to indicate 'mains ON', 'load on mains', Set running', 'load on set' and 'battery charger on'.
viii) Audio visual alarm for 'Low lubricating oil pressure', 'High water temperature, Start failure', and DG over load'.
x) Microprocessor based relay with composite meter for digital display of following.
Generator voltage/AC Mains voltage.
Generator Current in all phases
Frequency
Power Factor
Energy
Indication for alternator supply
Running time indications number of hours of operation and service intervals, service due indications
The AMF panel must be designed to ensure trouble free performance and ensure switching over Electrical Load to DG within 15 (fifteen) second from the instant of mains failure.
ACOUSTIC ENCLOSURE
The DG set should have integrated acoustic enclosure at the manufacturing state itself. High quality acoustict enclosure must be certified as per CPCB-II norms.
BASE FRAME
Common iron channel fabricated base frame containing the engine and alternator, mounted on AVM pads and having provision for lifting Hook.
TERMS & CONDITIONS
(i) Rate should be quoted inclusive of all applicable taxes and Duty etc.
(ii) All materials, equipments & accessories must conform to relavent IS /IEC specifications. The DG Set to be supplied must be from the authorized OEM of the respective Engine Manufacturer.
(iii) Nacessary manufacturer's test certificate for Desiel Engine, Alternator etc. Will have to submit in triplicate copy during delivery of the equipment.
(iv) Copy of "Type Approval Certificate" and Certificate of "COP" must be produced at the time of delivery issued from competant Authority (As per CPCB-II).
(v) Circuit Diagram for AMF Panel must be submited from the Manufacturer/OEM.
(vi) The entire set must be warranted atleast 15 months from the date of Delivery/12 months/ 5000 Hrs from the date of Commissioning whichever is earlier. However Engine & Alternator should be warranted of 2 years/5000 Hrs, whichever is earlier.
(vii) Necessary Control cable (12 Core 2.5 Sq.mm stranded armour copper cable) for connecting DG & AMF Panel -- 5 mtrs. to be supplied on Free of cost
S& delivery 70 sq. mm. single core multistrand PVC insulated flexible Cu cable and uPVC pipe (for neutral earthing)
Laying only Cable above 50 sqmm but not exceeding 400sqmm through existing RCC/ Hume/GI Pipe/open masonary trench for single, 2, 3, 3½ and 4 core. [3(b)/F-1].
Finishing the cable ends by crimping method incl. S&F copper socket, insulating tape and jointing materials etc. as required suitable for single core 70 sq. mm. copper wire.
Extending the exhaust pipe with 100 mm. dia MS black pipe (Thickness 4 mm) including connection with the existing silencer attached with the flexible coupler and S&F flange, nuts, bolts & washers etc. & necessary fixing materials etc. as required from DG set upto 2.5 Mts high of the near higher installation with Asbestos rope / 2'' glass wool insulation and chicken net and Aluminium fol covering, with end cap with suitable high temperature painting.
S&F special type MS angle iron bracket support made of 40x40x6 mm. MS angle with flat iron clamp with nuts, bolts & washers etc. for 100 mm. dia MS black pipe. (Vertical Run).
Filling of HSD oil for initial refill with transportation.
Supply and delivery of best quality oil hand pump with 1" dia PVC flexible pipe (10 mtr. approx.)
Supply and delivery of 200 ltr. Capacity heavy gauge MS sheet barrel
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS . [ 2(a)/G-1]
Connecting the equipment with 25mmx6mm galvanised MS hot dip flat on wall/floor as to GS. [5d/G-3]
Earth work in excavation of foundation trenches of drains, in all sorts of soil including removing, spreading or stacking the spoils within a lead of 75m as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.( Depth of Excavation not exceeding 1500 mm ) [ Page- 1, Item no.- 2(a) of PWD Schedule of Rates, Volume-I of Building Works, 2017 ]
Earth work in filling in foundation trench or plinth with good earth in layers Board a) With earth obtained from excavation of foundation 1/5th of excavated earth [ Page 1, Item no.3(a) of PWD Schedule of Rates, Volume-I of Building Works, 2017 ]
Filling in foundation or plinth by silver sand in layer a) With earth obtained from excavation of foundation 1/5th of excavated earth [ Page- 2, Item no.- 4(A) of PWD Schedule of Rates, Volume-I of Building Works, 2017 ]
Single Brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand [ Page- 14, Item no.1 of PWD Schedule of Rates, Volume-I of Building Works, 2017]
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.. A)For works in foundation and top of ground floor / upto 4 m i) Tor steel/ Mild steel SAIL/ TATA/RINL. [ Page- 43, Item no.40(a)(i)(I) of PWD Schedule of Rates, Volume-I of Building Works, 2017 ]
Ordinary cement concrete (mix 1:1.5:3) with graded stone chips (20 mm size) including shuttering and reinforcement, if any, in ground floor as per relevant IS codes ( Pakur variety ) [ Page 26, item no.10 of PWD Schedule for Building works with latest ammendmen ]
Brick work with 1st class bricks in cement mortar (1:4) In foundation and plinth. [ Page- 16, item no.-13(a)-(i) of PWD Schedule of Rates, Volume-I of Building Works, 2017 ]
Plaster (to wall, floor, ceiling etc.) of 10 mm thick with sand and cement with 1:4 cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] [ Page- 189, item no.-1(ii)-(c) of PWD Schedule of Rates, Volume-I of Building Works, 2017 ]
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE: Cement 0.152 cu.m per 100 sq.m. [ Page- 192, item no.-15 of PWD Schedule of Rates, Volume-I of Building Works, 2017 ]
JANA AND COMPANY
UNION ENGINEERING COMPANY
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .